Michael Bunn
Michael Bunn has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Boon-Chong Seet
Department of Electrical and Electronic Engineering, Auckland University of Technology, Auckland 1010, New Zealand
2 shared publications - Craig Baguley
Department of Engineering, Computer and Mathematical Sciences, Auckland University of Technology, Auckland, New Zealand
2 shared publications Zack Campbell
CO, US
2 shared publications- Ben Leshchinsky
Oregon State University, Corvallis, Oregon, U.S.A.
1 shared publication - Bhaba Priyo Das
University of Canterbury
1 shared publication - Daniel Martin
Power and Energy Systems, University of Queensland, St. Lucia, QLD 4072, Australia
1 shared publication
Latest Publications
- 28 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (6) , 5124-5132
A Thermally-Based Dynamic Approach to the Load Management of Distribution Transformers
The future demand for electric vehicle (EV) charging power is expected to increase the peak loading of existing distribution transformers. In the absence of appropriate solutions, this may lead to the replacement of transformers with higher-rated types, incurring significant expense. Therefore, a novel approach is proposed to improve the management of transformer EV charging loads, avoiding or postponing the need for a transformer upgrade. It allows for the determination of whether loads that exceed transformer nameplate ratings are acceptable in terms of power level, time and duration. This is achieved with knowledge of the maximum charging duration, transformer thermal time constants, current loading levels, voltage regulation limits, oil pressure and temperature limits, and desired transformer lifetime requirements. The results of a case study are presented based on a future EV car park scenario for which an EV charging load is added to the existing base load on a 300 kVA transformer. The results show the proposed approach has advantages over the traditional approach of limiting loading to nameplate levels. These include reduced waiting time and increased levels of charging power, which are achieved without compromising the desired transformer lifetime target.
- 28 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (6) , 5124-5132
A Thermally-Based Dynamic Approach to the Load Management of Distribution Transformers
The future demand for electric vehicle (EV) charging power is expected to increase the peak loading of existing distribution transformers. In the absence of appropriate solutions, this may lead to the replacement of transformers with higher-rated types, incurring significant expense. Therefore, a novel approach is proposed to improve the management of transformer EV charging loads, avoiding or postponing the need for a transformer upgrade. It allows for the determination of whether loads that exceed transformer nameplate ratings are acceptable in terms of power level, time and duration. This is achieved with knowledge of the maximum charging duration, transformer thermal time constants, current loading levels, voltage regulation limits, oil pressure and temperature limits, and desired transformer lifetime requirements. The results of a case study are presented based on a future EV car park scenario for which an EV charging load is added to the existing base load on a 300 kVA transformer. The results show the proposed approach has advantages over the traditional approach of limiting loading to nameplate levels. These include reduced waiting time and increased levels of charging power, which are achieved without compromising the desired transformer lifetime target.
- 2 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 34 (4) , 1803-1813
Empirical Design Method for Distribution Transformer Utilization Optimization
The increasing penetration of electric vehicles and distributed generation into distribution networks is giving rise to higher, more volatile and bi-directional energy flows through distribution transformers (DTs). To minimise future capital expenditure, improved DT design approaches are required. Therefore, a novel DT design approach “design for maximum utilisation” is proposed. It incorporates manufacturer and customer-sourced empirical data to achieve a desired DT retirement age and utilisation rate, and allows for transient operation beyond DT nameplate rating through accurately accounting for thermal inertia. Novelty derives not only from a design approach based on maximising DT utilisation, but also allowing for the fact that winding insulation may not be the most critical factor affecting a DT's lifetime. Using the proposed approach DT capital expenditure and utilisation constraints can be optimised at a planning stage. The algorithm is applied and validated.
- 2 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 34 (4) , 1803-1813
Empirical Design Method for Distribution Transformer Utilization Optimization
The increasing penetration of electric vehicles and distributed generation into distribution networks is giving rise to higher, more volatile and bi-directional energy flows through distribution transformers (DTs). To minimise future capital expenditure, improved DT design approaches are required. Therefore, a novel DT design approach “design for maximum utilisation” is proposed. It incorporates manufacturer and customer-sourced empirical data to achieve a desired DT retirement age and utilisation rate, and allows for transient operation beyond DT nameplate rating through accurately accounting for thermal inertia. Novelty derives not only from a design approach based on maximising DT utilisation, but also allowing for the fact that winding insulation may not be the most critical factor affecting a DT's lifetime. Using the proposed approach DT capital expenditure and utilisation constraints can be optimised at a planning stage. The algorithm is applied and validated.
- 16 November 2014
- Published by Springer Nature
- p. 53-55
Academia
- 15 November 2014
- Published by Springer Nature
- p. 41-45
Outsourcing Investment Decision Making