CYCheng Yang

Cheng Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Cheng Yang has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Shuxiang Guo

    Department of Electronic and Electrical Engineering, Southern University of Science and Technology, Shenzhen, China

    4 shared publications
  • Xianqiang Bao

    Physical Intelligence Department, Max Planck Institute for Intelligent Systems, Stuttgart 70569, Germany

    4 shared publications
  • Liwei Shi

    Key Laboratory of Convergence Medical Engineering System and Healthcare Technology, Ministry of Industry and Information Technology, Beijing Institute of Technology, Beijing, China

    2 shared publications
  • Yangming Guo

    Key Laboratory of Convergence Biomedical Engineering System and Healthcare Technology, the Ministry of Industry and Information Technology, School of Automation, Beijing Institute of Technology, Beijing, China

    2 shared publications
  • Youxiang Li

    Department of Interventional Neuroradiology, Beijing Engineering Technology Research Center for Interventional Neuroradiology, Beijing Tiantan Hospital, Capital Medical University, Beijing, China

    2 shared publications
  • Yuhua Jiang

    Department of Interventional Neuroradiology, Beijing Engineering Technology Research Center for Interventional Neuroradiology, Beijing Tiantan Hospital, Capital Medical University, Beijing, China

    2 shared publications

Latest Publications

  • Cloud Communication-Based Sensing Performance Evaluation of a Vascular Interventional Robot System

    by Cheng Yang, Shuxiang Guo, Yangming Guo, Xianqiang Bao

    As an essential method for diagnosing and treating cardiovascular and cerebrovascular diseases, interventional surgery has always been a research hotspot in biomedical engineering research. The vascular interventional robot can improve the surgical environment of the surgeon and improve the safety and stability of the operation when assisting the surgeon to complete the surgical operation. In today’s global pandemic phenomena, the study of operating vascular interventional robots in remote situations is of more significant value. Based on the previous animal experiments and clinical trials, this paper presents a preliminary study of the interventional robot to complete surgery operations under the condition of long-distance cloud communication. After analyzing the influence of time delay in remote operation, a control strategy for predicting time delay was proposed, and an evaluation experiment was conducted. Through the human model evaluation, the sensing performance of robotic surgery under the condition of long-distance cloud communication is analyzed and compared with the experiments in previous studies. The experimental results show that the operator can remotely control the robot to complete the intubation operation, which is valuable for further study and animal experiments.


  • Top Cited Papers

    Multilevel Operation Strategy of a Vascular Interventional Robot System for Surgical Safety in Teleoperation

    by Xianqiang Bao, Shuxiang Guo, Yangming Guo, Cheng Yang, Liwei Shi, Youxiang Li, Yuhua Jiang

    Remote-controlled vascular interventional robots have great potential for use in minimally invasive vascular surgeries in recent years due to their ability to reduce the occupational risk of surgeons and improve the stability and accuracy of surgical procedures. However, blood vessels will suffer from the damage caused by collision with medical instruments to some extent even though the surgeries are very successful. Moreover, when surgeons perform unsafe operations, the unsafe operations will not only seriously affect surgical safety (or even cause serious complications) but also restrict the continuity of operation. In this article, a multilevel concept for operating force is first introduced into surgical procedures as a reference for the choice and design of operation strategies. Based on this concept, a novel multilevel operation strategy is first proposed to reduce blood vessel damage, ensure surgical safety, and allow for continuous operation. This strategy can remind surgeons about the operative conditions in real-time, reduce collision to blood vessels, and eliminate unsafe operations online. A prototype was fabricated and calibrated through calibration experiments and the performance of the multilevel operation strategy was validated through in vitro and ex vivo experiments. Experimental results demonstrate the engineering effectiveness of the proposed method and motivate the need for further in vivo studies to evaluate improvement on surgical safety.


  • Open Access

    An Isomorphic Interactive Device for the Interventional Surgical Robot after In Vivo Study

    by Cheng Yang, Shuxiang Guo, Xianqiang Bao

    Interventional surgical robots are widely used in neurosurgery to improve surgeons’ working environment and surgical safety. Based on the actual operational needs of surgeons’ feedback during preliminary in vivo experiments, this paper proposed an isomorphic interactive master controller for the master–slave interventional surgical robot. The isomorphic design of the controller allows surgeons to utilize their surgical skills during remote interventional surgeries. The controller uses the catheter and guidewire as the operating handle, the same as during actual surgeries. The collaborative operational structure design and the working methods followed the clinical operational skills. The linear force feedback and torque feedback devices were designed to improve the safety of surgeries under remote operating conditions. An eccentric force compensation was conducted to achieve accurate force feedback. Several experiments were carried out, such as calibration experiments, master–slave control performance evaluation experiments, and operation comparison experiments on the novel and previously used controllers. The experimental results show that the proposed controller can perform complex operations in remote surgery applications and has the potential for further animal experiment evaluations.


  • A vascular interventional surgical robot based on surgeon’s operating skills

    by Cheng Yang, Shuxiang Guo, Xianqiang Bao, Nan Xiao, Liwei Shi, Youxiang Li, Yuhua Jiang

    Interventional surgery is widely used in the treatment of cardiovascular and cerebrovascular diseases, and the development of surgical robots can greatly reduce the fatigue and radiation risks brought to surgeons during surgery. In this paper, we present a novel interventional surgical robot which allows surgeons to fully use their operating skills during remote control. Fuzzy control theory is used to guarantee control precision during the master-slave operation. The safety force feedback control is designed based on the catheter and guidewire spring model, and the force-position control is designed to decrease the potential damage due to the control delay. This study first evaluates the force-position control strategy using a vascular model experiment, and then an in vivo experiment is used to evaluate the precision of the surgical robot controlling the catheter and guidewire to the designated position. The in vivo experiment results and surgeon’s feedback demonstrate that the proposed surgical robot is able to perform complex remote surgery in clinical application.