Donghyun Seo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Donghyun Seo has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Moncef Krarti
Civil, Environmental, and Architectural Engineering Department, University of Colorado, Boulder, CO 80309, USA
10 shared publications Adnan Al-Anzi
University of Kuwait, Kuwait City, Kuwait
2 shared publications- Hye-Jin Kim
Department of Architectural Engineering, Chungbuk National University, Cheongju 28644, Republic of Korea
2 shared publications Lyool Park
University of Colorado Boulder
2 shared publicationsPyeongchan Ihm
Dong A University
2 shared publications- Seok-Ho Kim
BECUBE. Inc., Cheongju 28644, Republic of Korea
2 shared publications
Latest Publications
- Open Access
Detailed Building Energy Impact Analysis of XPS Insulation Degradation Using Existing Long-Term Experimental Data
This study investigates the long-term impact of insulation degradation on building heating energy consumption, with a focus on extruded polystyrene (XPS) insulation. Year-by-year degradation in thermal transmittance was derived from long-term experimental data and applied to prototypical energy models of multifamily apartment buildings and office buildings. Simulations were performed using both Actual Meteorological Year (AMY) and Typical Meteorological Year (TMY) data for six cities representing Korea’s major climate zones. The results showed that insulation degradation led to a significant increase in heating energy consumption from 23.2% to 34.9% in AMY simulations and 23.5% to 36.2% in TMY simulations for multifamily apartment buildings over 15 years. The difference between the AMY and TMY estimates was within 4%, demonstrating the reliability of TMY for long-term performance assessments. Notably, the southern and Jeju zones exhibited higher sensitivity to degradation due to their relaxed insulation standards and lower initial thermal performance. Office buildings were less affected, with increases below 8%, attributed to smaller envelope areas and higher internal heat gains. These findings highlight the need for zone-specific insulation standards and differentiated energy-saving design strategies by building type to ensure long-term energy efficiency.
Open AccessDetailed Building Energy Impact Analysis of XPS Insulation Degradation Using Existing Long-Term Experimental Data
This study investigates the long-term impact of insulation degradation on building heating energy consumption, with a focus on extruded polystyrene (XPS) insulation. Year-by-year degradation in thermal transmittance was derived from long-term experimental data and applied to prototypical energy models of multifamily apartment buildings and office buildings. Simulations were performed using both Actual Meteorological Year (AMY) and Typical Meteorological Year (TMY) data for six cities representing Korea’s major climate zones. The results showed that insulation degradation led to a significant increase in heating energy consumption from 23.2% to 34.9% in AMY simulations and 23.5% to 36.2% in TMY simulations for multifamily apartment buildings over 15 years. The difference between the AMY and TMY estimates was within 4%, demonstrating the reliability of TMY for long-term performance assessments. Notably, the southern and Jeju zones exhibited higher sensitivity to degradation due to their relaxed insulation standards and lower initial thermal performance. Office buildings were less affected, with increases below 8%, attributed to smaller envelope areas and higher internal heat gains. These findings highlight the need for zone-specific insulation standards and differentiated energy-saving design strategies by building type to ensure long-term energy efficiency.
- Open Access
- 16 July 2021
- Published by ASME International
Development of Typical Residential Buildings and Their Energy Consumption Features From Nationwide Household Energy Survey in S. Korea
Division / Sponsor: Advanced Energy Systems Division (AESD) & Solar Energy Division (SED)
- 16 July 2021
- Published by ASME International
Open AccessDevelopment of Typical Residential Buildings and Their Energy Consumption Features From Nationwide Household Energy Survey in S. Korea
Division / Sponsor: Advanced Energy Systems Division (AESD) & Solar Energy Division (SED)
- Open Access
Development of a Consecutive Occupancy Estimation Framework for Improving the Energy Demand Prediction Performance of Building Energy Modeling Tools
To improve the energy prediction performance of a building energy model, the occupancy status information is very important. This is more important in real buildings, rather than under construction buildings, because actual building occupancy can significantly influence its energy consumption. In this study, a machine learning based framework for a consecutive occupancy estimation is proposed by utilizing internet of things data, such as indoor temperature and luminance, CO2 density, electricity consumption of lighting, HVAC (heating, ventilation, and air conditioning), electric appliances, etc. Three machine learning based occupancy estimation algorithms (decision tree, support vector machine, artificial neural networks) are selected and evaluated in terms of the performance of estimating the occupancy status for each season. The selection process of the input variables that have crucial impact on the algorithms’ performance are described in detail. Finally, an occupancy estimation framework that can repeat model training and estimation consecutively in a situation when time-series data are continuously provided over the entire measurement period is suggested. In addition, the performance of the framework is evaluated to identify how it improves the energy prediction performance of the building energy model compared to conventional energy modeling practices. The suggested framework is distinguished from similar previous studies in two ways: (1) The proposed framework reveals that input variables for the occupancy estimation model can be occasionally changed by an occupant response to certain times and seasons, and (2) the framework incorporates time-series indirect occupancy sensing data and classification algorithms to consecutively provide occupancy information for the energy modeling effort.
Open AccessDevelopment of a Consecutive Occupancy Estimation Framework for Improving the Energy Demand Prediction Performance of Building Energy Modeling Tools
To improve the energy prediction performance of a building energy model, the occupancy status information is very important. This is more important in real buildings, rather than under construction buildings, because actual building occupancy can significantly influence its energy consumption. In this study, a machine learning based framework for a consecutive occupancy estimation is proposed by utilizing internet of things data, such as indoor temperature and luminance, CO2 density, electricity consumption of lighting, HVAC (heating, ventilation, and air conditioning), electric appliances, etc. Three machine learning based occupancy estimation algorithms (decision tree, support vector machine, artificial neural networks) are selected and evaluated in terms of the performance of estimating the occupancy status for each season. The selection process of the input variables that have crucial impact on the algorithms’ performance are described in detail. Finally, an occupancy estimation framework that can repeat model training and estimation consecutively in a situation when time-series data are continuously provided over the entire measurement period is suggested. In addition, the performance of the framework is evaluated to identify how it improves the energy prediction performance of the building energy model compared to conventional energy modeling practices. The suggested framework is distinguished from similar previous studies in two ways: (1) The proposed framework reveals that input variables for the occupancy estimation model can be occasionally changed by an occupant response to certain times and seasons, and (2) the framework incorporates time-series indirect occupancy sensing data and classification algorithms to consecutively provide occupancy information for the energy modeling effort.
- 1 August 2018
- Published by Elsevier in Energy and Buildings
- Vol. 172, 152-158
Analysis of the variable heat exchange efficiency of heat recovery ventilators and the associated heating energy demand
- 1 August 2018
- Published by Elsevier in Energy and Buildings
- Vol. 172, 152-158
Analysis of the variable heat exchange efficiency of heat recovery ventilators and the associated heating energy demand
- Open Access
- 11 July 2018
- Published by Wiley in International Journal of Photoenergy
- Vol. 2018, 1-9
Comparative Analysis of All-Sky Luminous Efficacy Models Based on Calculated and Measured Solar Radiation Data of Four Worldwide Cities
Luminous efficacy model uses solar radiation data to generate illuminance data, and its performance also depends on the quality of solar radiation data. Various luminous efficacy models are reviewed and evaluated to select a universal luminous efficacy model. Since most luminous efficacy models are fitted with specific local climate characteristics, the model that has the least locality as well as accuracy is a mandatory requirement. Three representative luminous efficacy models are selected and evaluated with measured solar radiation and illuminance data from four worldwide cities. It was found that all the evaluated models provide good predictions (over 0.96 value) for both global and diffuse illuminance. Among them, the Perez luminous efficacy model shows the highest performance in terms of accuracy and bias. However, illuminance data prediction based on estimated solar radiation data is more common practice rather than those from measured solar data. The performance of the selected luminous efficacy models is evaluated when recently proposed universal solar radiation model supplies predicted solar radiation data. The result indicates that the quality of estimated solar radiation data has a much deeper impact on the performance of the luminous efficacy model. Within the current limited technology and measured data resource, the consecutive processing of the modified Zhang and Huang solar model and Perez luminous efficacy model could provide the best option to predict both global and diffuse solar radiation and illuminance. But, users of the model-based illuminance data should interpret their simulation results with the error (30%~40% in RMSE and ±6% in MBE) in predicting global and diffuse illuminance.- 11 July 2018
- Published by Wiley in International Journal of Photoenergy
- Vol. 2018, 1-9
Open AccessComparative Analysis of All-Sky Luminous Efficacy Models Based on Calculated and Measured Solar Radiation Data of Four Worldwide Cities
Luminous efficacy model uses solar radiation data to generate illuminance data, and its performance also depends on the quality of solar radiation data. Various luminous efficacy models are reviewed and evaluated to select a universal luminous efficacy model. Since most luminous efficacy models are fitted with specific local climate characteristics, the model that has the least locality as well as accuracy is a mandatory requirement. Three representative luminous efficacy models are selected and evaluated with measured solar radiation and illuminance data from four worldwide cities. It was found that all the evaluated models provide good predictions (over 0.96 value) for both global and diffuse illuminance. Among them, the Perez luminous efficacy model shows the highest performance in terms of accuracy and bias. However, illuminance data prediction based on estimated solar radiation data is more common practice rather than those from measured solar data. The performance of the selected luminous efficacy models is evaluated when recently proposed universal solar radiation model supplies predicted solar radiation data. The result indicates that the quality of estimated solar radiation data has a much deeper impact on the performance of the luminous efficacy model. Within the current limited technology and measured data resource, the consecutive processing of the modified Zhang and Huang solar model and Perez luminous efficacy model could provide the best option to predict both global and diffuse solar radiation and illuminance. But, users of the model-based illuminance data should interpret their simulation results with the error (30%~40% in RMSE and ±6% in MBE) in predicting global and diffuse illuminance. - Open Access
- 1 December 2013
- Published by Elsevier in Energy and Buildings
- Vol. 67, 236-244
Thermal transmittance of window systems and effects on building heating energy use and energy efficiency ratings in South Korea
- 1 December 2013
- Published by Elsevier in Energy and Buildings
- Vol. 67, 236-244
Open AccessThermal transmittance of window systems and effects on building heating energy use and energy efficiency ratings in South Korea
- 29 March 2013
- Published by Taylor & Francis in International Journal of Ventilation
- Vol. 11 (4) , 381-391
Analysis of Reduced Cooling Load for a Multistorey-Building Incorporating a Ventilated Double Skin FaÇade with a Solar Chimney Channel
A double skin façade (DSF) aims at reducing heating and cooling loads by taking advantage of daylight and utilizing heated air for space heating. To take advantage of a DSF a sophisticated design is required. In this paper a DSF building that has overheating problems was selected to verify the causes and propose remedial solutions. The problem was verified by analyzing the measured solar radiation, inside and outside temperature and air velocity. The results of the measurement analysis showed that airflow congestion caused overheating inside the building. A solar chimney channel (SCC) was proposed as a solution to enhance natural ventilation (NV) through the DSF. Simulations using EnergyPlus incorporating an airflow network were used to verify the proposed solutions. Two remedial design options were considered. The first was to extend the height of the solar chimney channel and the second was to increase penetration of solar radiation through the outer skin and the solar absorptivity of the inner wall of the SCC path. The thermal environment inside the DSF and the indoor cooling load of spaces adjacent to the DSF were investigated through simulation. The results showed that natural ventilation of the inside of the DSF would be increased by applying the two options. Especially, in the case of improving the thermal effect at the SCC path, the annual cooling load could be reduced by almost 3% (2.84%) compared with a non-SCC case.
- 29 March 2013
- Published by Taylor & Francis in International Journal of Ventilation
- Vol. 11 (4) , 381-391
Analysis of Reduced Cooling Load for a Multistorey-Building Incorporating a Ventilated Double Skin FaÇade with a Solar Chimney Channel
A double skin façade (DSF) aims at reducing heating and cooling loads by taking advantage of daylight and utilizing heated air for space heating. To take advantage of a DSF a sophisticated design is required. In this paper a DSF building that has overheating problems was selected to verify the causes and propose remedial solutions. The problem was verified by analyzing the measured solar radiation, inside and outside temperature and air velocity. The results of the measurement analysis showed that airflow congestion caused overheating inside the building. A solar chimney channel (SCC) was proposed as a solution to enhance natural ventilation (NV) through the DSF. Simulations using EnergyPlus incorporating an airflow network were used to verify the proposed solutions. Two remedial design options were considered. The first was to extend the height of the solar chimney channel and the second was to increase penetration of solar radiation through the outer skin and the solar absorptivity of the inner wall of the SCC path. The thermal environment inside the DSF and the indoor cooling load of spaces adjacent to the DSF were investigated through simulation. The results showed that natural ventilation of the inside of the DSF would be increased by applying the two options. Especially, in the case of improving the thermal effect at the SCC path, the annual cooling load could be reduced by almost 3% (2.84%) compared with a non-SCC case.
- 1 February 2013
- Published by Elsevier in Energy and Buildings
- Vol. 57, 250-260
Feasibility study on a novel methodology for short-term real-time energy demand prediction using weather forecasting data
- 1 February 2013
- Published by Elsevier in Energy and Buildings
- Vol. 57, 250-260
Feasibility study on a novel methodology for short-term real-time energy demand prediction using weather forecasting data
- 1 May 2012
- Published by Elsevier in Energy Policy
- Vol. 44, 1-9
Impact of window selection on the energy performance of residential buildings in South Korea
- 1 May 2012
- Published by Elsevier in Energy Policy
- Vol. 44, 1-9
Impact of window selection on the energy performance of residential buildings in South Korea
- 26 April 2012
- Published by Elsevier in Energy and Buildings
- Vol. 51, 122-130
Optimal electrical circuiting layout and desk location for daylighting controlled spaces
- 26 April 2012
- Published by Elsevier in Energy and Buildings
- Vol. 51, 122-130
Optimal electrical circuiting layout and desk location for daylighting controlled spaces