ADArmand van Deursen

Armand van Deursen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Armand van Deursen has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Thermal Distortion of Signal Propagation Modes Due to Dynamic Loading in Medium-Voltage Cables

    by Peter Wouters, Armand van Deursen

    Temperature variation from dynamic cable loading affects the propagation characteristics of transient signals. The distortion of modal signal components as a function of temperature in a three-phase medium-voltage cable is investigated. The temperature influence arises mainly through the complex insulation permittivity, which has a non-linear relationship with temperature. Near the maximum operating temperature of the cross-linked polyethylene insulation, the propagation velocity increases by 0.56% per degree centigrade but is an order of magnitude less sensitive at ambient temperature. The paper presents modeling results based on cable impedance and admittance matrices obtained from electromagnetic field simulation, taking into account the time-varying temperature distribution in the cable cross-section. The results are verified by applying Rayleigh–Schrödinger perturbation analysis. In the time domain, signal patterns shift when the modal propagation velocities change upon cable loading. Moreover, separation of degenerate modes is observed when the cable phase conductors carry an unbalanced current. The perspectives for exploiting the temperature dependency of signal propagation for pinpointing cable defects and for dynamic rating of underground power cables are discussed.


  • Open Access

    Methodology and accuracy for non‐invasive detection of switching transient overvoltages from compensation coils connected to power transformers

    by Peter Wouters, Armand van Deursen, Mischa Vermeer

    Transient voltages from (dis)connecting compensation coils near high voltage transformers are studied. Non‐invasive sensors are needed in order to exclude any influence by the measurement equipment on the overvoltage magnitude. This study describes results from open‐air capacitive sensors as part of a differentiating/integrating measurement system. Its bandwidth (up to 10MHz) allows to record large detail in the switching events. However, the coupling strengths and the cross‐couplings inherent to the use of air capacitive sensors need to be determined. Calibration based on symmetric phase voltages during normal operation supplies part of the information. Three methods are compared to supplement this knowledge for establishing the complete coupling matrix between phase conductors and sensors. One method employs estimates from the system configuration, in particular, its symmetry. The other techniques extract information from fast transient events within the responses for both switching on and off. The decoupled waveforms from different methodologies align within their confidence bounds and predict the maximum overvoltage magnitudes within an accuracy of 5% when employing information from the fast transients. Based on measurements performed on two compensation coils, both tested three times, larger overvoltages occurred during energisation compared to de‐energisation with maximum amplitude exceeding three per unit.


  • Open Access

    Corrosion in Low-Voltage Distribution Networks and Perspectives for Online Condition Monitoring

    by Armand van Deursen, Peter Wouters, Fred Steennis

    The low-voltage distribution grid is an essential link for the integration of distributed renewable sources. It is expected to experience stronger loading and load variation in the near future. At the same time, part of the low-voltage network is an aging infrastructure. Distribution system operators are therefore becoming increasingly interested in being able to diagnose their low-voltage assets. This paper describes corrosion phenomena that are observed in aluminum conductors after a damage is inflicted to a cable section. Such a damage is suspected to initiate long-term degradation. Short-duration intermittent current peaks are observed in laboratory experiments and similar peaks are now also recorded in the field. The perspectives for online monitoring, by registering these events, are investigated by having a large number of measurement devices installed on connections in service. The research is directed to gain a better understanding of the relation between the current peaks and cable circuit failures as well as the underlying degradation mechanisms.


  • Impact of corrosion on the reliability of low voltage cables with aluminium conductors

    by A. van Deursen, B. Kruizinga, P.A.A.F. Wouters, E.F. Steennis

    Aluminium is widely used as conductor material for power cables, but corrosion taking place under specific circumstances can have impact on its reliability. Aluminium corrosion under the influence of an alternating current was studied experimentally. Submerged cable segments with inflicted damage exposing the conductors resulted in a continuous corrosion of the conductor material. Effects of temperature and applied voltage were studied by observing corrosion of an aluminium wire. These parameters strongly affect the corrosion rate. Comparison with copper showed that aluminium is far more susceptible to corrosion. The impact of corrosion on the reliability of the cables is discussed.