Lei Zhicheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lei Zhicheng has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Fuping Zeng
State Key Laboratory of Power Grid Environmental Protection, School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China
2 shared publications - Ju Tang
School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China
2 shared publications - Huang Xuancheng
Jiangsu Frontier Electric Technology Co., LTD
1 shared publication - Qiang Yao
Electric Power Research Institute of State Grid Chongqing Electric Power Company
1 shared publication - Qiang Yao
State Grid Chongqing Electric Power Company Electric Power Scientific Research Institute, Chongqing, China
1 shared publication - Wu Mumu
Jiangsu Frontier Electric Technology Co., LTD
1 shared publication
Latest Publications
- 22 April 2022
- Published by Springer Nature
- p. 1347-1358
Analysis of a Breakdown Accident Caused by Defects in the Terminal Stress Cone Interface of 220 kV Submarine Cable
- 22 April 2022
- Published by Springer Nature
- p. 1347-1358
Analysis of a Breakdown Accident Caused by Defects in the Terminal Stress Cone Interface of 220 kV Submarine Cable
- 31 October 2019
- Published by Springer Nature
- p. 43-51
Reaction Thermodynamics of Overthermal Decomposition of C6F12O
- 31 October 2019
- Published by Springer Nature
- p. 43-51
Reaction Thermodynamics of Overthermal Decomposition of C6F12O
- 27 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 34 (4) , 1383-1392
Evaluating DC Partial Discharge With SF6 Decomposition Characteristics
This study mainly aims to obtain the decomposition characteristics of SF6 under various degrees of negative partial discharge (PD) and establish a method for evaluating internal PD fault for gas-insulated equipment (GIE). Thus, metal protrusion, a frequent insulation defect in DC GIE, was used in the study of PD characteristics from the initial discharge to the near breakdown process. Then, seven parameters for characterizing the development stage of PD were extracted, and the fuzzy C-means clustering algorithm was used for the categorization of PD into three degrees, namely, slight, medium, and severe. We performed SF6 decomposition experiments on the PD degrees to obtain the decomposition characteristics. Results show that the SF6 decomposition characteristics (formation and content variation of five characteristic components, namely, CF4, CO2, SO2F2, SOF2, and SO2) are closely related to PD status. Fuzzy comprehensive evaluation theory was used for the establishment of a PD fault status assessment model, which was based on SF6 decomposition characteristics. Then evaluate the collected samples and the accuracy of the evaluation method is up to 87.5%. This paper lays the foundation for the future comprehensive assessment and fault diagnosis of insulation status of DC GIE on the basis of SF6 decomposition characteristics.
- 27 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 34 (4) , 1383-1392
Evaluating DC Partial Discharge With SF6 Decomposition Characteristics
This study mainly aims to obtain the decomposition characteristics of SF6 under various degrees of negative partial discharge (PD) and establish a method for evaluating internal PD fault for gas-insulated equipment (GIE). Thus, metal protrusion, a frequent insulation defect in DC GIE, was used in the study of PD characteristics from the initial discharge to the near breakdown process. Then, seven parameters for characterizing the development stage of PD were extracted, and the fuzzy C-means clustering algorithm was used for the categorization of PD into three degrees, namely, slight, medium, and severe. We performed SF6 decomposition experiments on the PD degrees to obtain the decomposition characteristics. Results show that the SF6 decomposition characteristics (formation and content variation of five characteristic components, namely, CF4, CO2, SO2F2, SOF2, and SO2) are closely related to PD status. Fuzzy comprehensive evaluation theory was used for the establishment of a PD fault status assessment model, which was based on SF6 decomposition characteristics. Then evaluate the collected samples and the accuracy of the evaluation method is up to 87.5%. This paper lays the foundation for the future comprehensive assessment and fault diagnosis of insulation status of DC GIE on the basis of SF6 decomposition characteristics.