SGStefan Gaugler

Stefan Gaugler

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Stefan Gaugler has a total of 78 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Automated derivatization and sample preparation protocol for ultrashort-chain PFCAs of water samples for GC-MS/MS detection

    by Rouven Häusler, Alexander Laver, Johanna Freilinger, Hagen M. Gegner, Marco Rupprich, Daniel Häussinger, Stefan Gaugler

  • Open Access

    Predictors of Fasting Endogenous Erythritol and Erythronate Concentrations in Humans: Cross-Sectional and Post-Bariatric Surgery Analyses

    by Emilie Flad, Anita Altstädt, Jürgen Drewe, Stefan Gaugler, Christoph Beglinger, Ralph Peterli, Bettina K. Wölnerhanssen, Anne Christin Meyer-Gerspach

    The sugar alcohol erythritol occurs naturally in fruits and fermented foods, is used as a sweetener, and is also endogenously synthesized via the pentose-phosphate pathway and metabolized into erythronate. Untargeted metabolomic studies have associated elevated plasma erythritol and erythronate concentrations with metabolic disorders, while weight loss has been linked to decreased plasma erythritol concentrations. In this trial, two complementary analyses were performed to identify predictors of fasting erythritol and erythronate concentrations across different populations and to assess changes in these metabolites following bariatric surgery-induced weight loss. Fasting plasma samples from 30 lean adolescents, 50 lean adults, and 138 adults with obesity (including 15 who had undergone bariatric surgery) were analyzed to measure erythritol, erythronate, glucose, and insulin concentrations. Across all populations, age but not body mass index (BMI), glucose, or insulin, was a significant predictor of fasting erythritol concentrations. Fasting erythronate concentrations were associated with both age and BMI. Post-surgery, change in BMI but not fasting glucose or insulin was a predictor of changes in fasting erythritol concentrations, while time was the only predictor of changes in fasting erythronate concentrations. Although the metabolic processes regulating the endogenous erythritol and erythronate production remain unclear, our findings suggest that age-related physiological changes may influence fasting concentrations of both erythritol and erythronate.

  • Open Access

    Towards quantitative microplastic analysis using pyrolysis-gas chromatography coupled with mass spectrometry

    by Katharina Elisabeth Grafinger, Celandin Ochiai, Huan-Xiao Zhou, Timm Hettich, Andre Büttler, Romina Álvarez Troncoso, Armin Zenker, Stefan Gaugler


  • Open Access

    Analysing and quantifying chronic stress‐associated endogenous steroids in hair samples

    by Katharina Elisabeth Grafinger, Wassilis Kassis, Céline A. Favre, Dilan Aksoy, Stefan Gaugler

    In previous studies, various steroids have been associated with stress and have therefore been quantified to investigate stress‐related questions. Since the main stress‐related steroid cortisol follows a circadian rhythm, often hair is analysed to quantify this steroid. Further, hair analysis gives the unique possibility of long‐time monitoring by analysing a certain segment of hair, since hair grows on average 1 cm per month. Hair is a difficult matrix due to the complex sample preparation with many steps including washing and grinding, followed by various extraction steps. Additionally, steroids are endogenous and are therefore present in the hair matrix. Hence, no analyte free matrix is available, which is needed for the quantification via external calibrators. To overcome this problem, the so‐called surrogate methods can be used, for which a 13C3 labelled or deuterated reference compound of the steroid of interest is used for quantification. In the present study, a surrogate method was developed and fully validated for the quantitative analysis of seven steroids in human hair. Validation experiments showed that the method is further suitable for semi‐quantitative analysis of estradiol. However, it is not suitable for the analysis of androsterone and DHEAS. The method was successfully used to analyse steroids in a comprehensive study of 360 adolescent hair samples, enabling research into stress markers.


  • Application of Dried Urine Spots for Non-Targeted Quadrupole Time-of-Flight Drug Screening

    by Frederike Stöth, Marie Martin Fabritius, Wolfgang Weinmann, Marc Luginbühl, Stefan Gaugler, Stefan König

    The use of dried urine spots (DUS) can simplify sample handling, shipment, and storage when compared to liquid urine samples. To prepare DUS, a small amount of urine is pipetted on a filter paper card. The subsequent drying of the specimen can prevent the post-sampling formation or degradation of substances (e.g. caused by bacteria). To evaluate the potential of DUS screening, 17 authentic urine samples, containing a broad range of substances, were extracted and analyzed on a Sciex 5600 TOF instrument using a non-targeted screening and library searching approach. The screening results were compared to the analysis of the same urine sample in liquid form, using the same high resolution liquid chromatography quadrupole time-of-flight mass spectrometry method. More than 65 different legal and illegal drugs were successfully identified within the investigated 17 urine samples using the DUS screening approach. When compared to the analysis of liquid urine, the following compounds could not be identified: 1x ecgonine methyl ester, 1x nicotine, 1x promazine, 1x 11-Nor-9-carboxy-Δ9-tetrahydrocannabinol. Overall, 95.2% of the target substances that have been detected in liquid urine were identified correctly using the DUS approach. In conclusion, DUS screening offers a simple, cost-effective, and easier sample handling alternative to the traditional use of liquid urine and provides detection of the most important substances for forensic requirements. Furthermore, the DUS sample preparation can be fully automated (sample documentation, internal standard application, and extraction).


  • Open Access

    Comparison of automated determination of phosphatidylethanol (PEth) in dried blood spots (DBS) with previous manual processing and testing

    by Robin Fatch, Marc Luginbühl, Debbie M. Cheng, Stefan Gaugler, Nneka I. Emenyonu, Christine Ngabirano, Julian Adong, Winnie R. Muyindike, Jeffrey H. Samet, Kendall Bryant, et al.


  • Quantitative determination of phosphatidylethanol in dried blood spots for monitoring alcohol abstinence

    by Marc Luginbühl, Frederike Stöth, Alexandra Schröck, Stefan Gaugler, Wolfgang Weinmann

    Phosphatidylethanol (PEth), which is formed by enzymatic reaction between ethanol and phosphatidylcholine, is a direct marker for alcohol usage. PEth has a long elimination half-life (~5–10 d) and specimens can be sampled using minimally invasive microsampling strategies. In combination with rapid analysis procedures PEth has proved to be advantageous for the detection of abstinence over other direct (e.g., ethyl glucuronide in blood, urine or hair) and indirect (e.g., carbohydrate-deficient transferrin in serum) alcohol markers. Although PEth determination is widely applied around the world, laboratory protocols are not standardized. Here we provide general guidelines for the analysis of PEth in dried blood spots (DBSs), including reference material evaluation, synthesis of a deuterated internal standard, preparation of calibration samples (reference material in teetotaller blood), and analyte separation and detection. The protocol contains information to extract the DBSs either manually or with a fully automated autosampler. Extraction of the analytes from DBS filter paper cards is performed using an organic extraction, followed by liquid chromatography coupled to tandem mass spectrometry (LC–MS/MS). For accurate and reliable measurement of PEth, the two most abundant analogs, PEth 16:0/18:1 and PEth 16:0/18:2, are quantified. We show data that provide guidelines on how to interpret the results for both demographic studies and forensic applications. The described protocol can be applied by experienced laboratory staff with basic LC–MS/MS knowledge and takes 2 d to perform.


  • Fully Automated Optical Hematocrit Measurement from Dried Blood Spots

    by Marc Luginbühl, Yannick Fischer, Stefan Gaugler

    The impact of the hematocrit (HCT) on the dried blood spot (DBS)’s spreading area is one of the most important hurdles, which prevents the full acceptance of quantitative microsampling strategies. Several destructive and non-destructive strategies to assess the HCT from a DBS post-sampling have been presented. Unfortunately, the current methods are either labor-intensive, require a complicated algorithm or are not automatable. Here, we present a novel setup that permits the fully automated reflectance analysis to measure the HCT from a DBS. The underlying principle is based on the concept of the non-destructive single-wavelength HCT measurement. The novel module was embedded within the DBS-MS 500 platform to enable high-throughput analysis of HCT values in combination with automated DBS extraction. The novel setup was assessed and optimized for the probe to card distance, stability, anti-coagulant, spotting volume, scan number, calibration variability, accuracy and precision. It showed excellent inter-day (≤3.7%) and intra-day (≤1.16%) precision as well as high accuracy when analyzing authentic samples (101% ± 7% [range: 87–127%]). Besides, the simple and straightforward application of an HCT correction for DBS was demonstrated during a pharmacokinetic study with diclofenac involving three subjects. Thereby, the sample’s HCT and the HCT impact on the analyte were assessed and compensated. In conclusion, the novel setup enables quantitative analysis of non-volumetric samples in an automated fashion without compromising the concept of cost-effective, minimally invasive sampling.