Yahya Danayiyen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yahya Danayiyen has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Aleyna Begüm Taşdemir
Department of Civil Engineering, Karadeniz Technical University Faculty of Engineering, Trabzon, Türkiye
3 shared publications - Chivon Choeung
Faculty of Electricity, National Polytechnic Institute of Cambodia, Phnom Penh 12409, Cambodia
3 shared publications - Emirhan Yeter
Department of Electrical and Electronics Engineering, Karadeniz Technical University, Trabzon 61080, Türkiye
3 shared publications - Furkan Heybetli
Department of Electrical and Electronics Engineering, Karadeniz Technical University Faculty of Engineering, Trabzon, Türkiye
3 shared publications - Şule Şenyiğit
Department of Electrical and Electronics Engineering, Karadeniz Technical University Faculty of Engineering, Trabzon, Türkiye
3 shared publications - Young Il Lee
Department of Electrical and Information Engineering, Seoul National University of Science and Technology (SeoulTech), Seoul, South Korea
2 shared publications
Latest Publications
- Open Access
- 19 October 2026
- Published by MDPI AG in Electronics
- Vol. 15 (20) , 4819
Adaptive Variable-Set Model Predictive Control with Error-Dynamics and Current-Stress Awareness for Dual-Active-Bridge Converters
Dual-Active-Bridge (DAB) DC-DC converters are widely used in modern power electronics applications due to their bidirectional power flow, high efficiency, and electrical isolation. However, traditional linear controllers are highly sensitive to parameter variations, which can degrade control performance under changing operating conditions. In addition, conventional Finite Control Set Model Predictive Control (FCS-MPC) methods may result in relatively high current and voltage ripple under steady-state conditions. Furthermore, existing Moving Discrete Control Set (MDCS-MPC) strategies can only partially address these issues because they have a fixed or limited control set. To address these problems, this paper proposes an Error-Dynamics and Current-Stress-Aware Adaptive Variable-Size Moving Control Set MPC (ED-AVCS-MPC) for DAB converters. In this article, using the example of a single-phase shift-operated dual-active-bridge converter, the proposed control design is explained in detail and analyzed thoroughly. The proposed strategy employs a composite activation index that continuously evaluates both the magnitude and the rate of change in the voltage error. Thus, the control set size (3, 5, or 7 elements) is dynamically adjusted via a hysteresis-based switching mechanism. A five-term dynamically weighted cost function is formulated to simultaneously penalize tracking deviation, voltage variation, excessive control effort, current stress, and boundary violations. Through comprehensive simulation studies, the superiority of the ED-AVCS-MPC over traditional PI and fixed-set MDCS-MPC approaches has been confirmed.
- 19 October 2026
- Published by MDPI AG in Electronics
- Vol. 15 (20) , 4819
Open AccessAdaptive Variable-Set Model Predictive Control with Error-Dynamics and Current-Stress Awareness for Dual-Active-Bridge Converters
Dual-Active-Bridge (DAB) DC-DC converters are widely used in modern power electronics applications due to their bidirectional power flow, high efficiency, and electrical isolation. However, traditional linear controllers are highly sensitive to parameter variations, which can degrade control performance under changing operating conditions. In addition, conventional Finite Control Set Model Predictive Control (FCS-MPC) methods may result in relatively high current and voltage ripple under steady-state conditions. Furthermore, existing Moving Discrete Control Set (MDCS-MPC) strategies can only partially address these issues because they have a fixed or limited control set. To address these problems, this paper proposes an Error-Dynamics and Current-Stress-Aware Adaptive Variable-Size Moving Control Set MPC (ED-AVCS-MPC) for DAB converters. In this article, using the example of a single-phase shift-operated dual-active-bridge converter, the proposed control design is explained in detail and analyzed thoroughly. The proposed strategy employs a composite activation index that continuously evaluates both the magnitude and the rate of change in the voltage error. Thus, the control set size (3, 5, or 7 elements) is dynamically adjusted via a hysteresis-based switching mechanism. A five-term dynamically weighted cost function is formulated to simultaneously penalize tracking deviation, voltage variation, excessive control effort, current stress, and boundary violations. Through comprehensive simulation studies, the superiority of the ED-AVCS-MPC over traditional PI and fixed-set MDCS-MPC approaches has been confirmed.
- Open Access
- 16 January 2026
- Published by Karadeniz Fen Bilimleri Dergisi in Karadeniz Fen Bilimleri Dergisi
- Vol. 16 (1) , 304-337
Determination of Control Parameters of a Bidirectional Dual Active Bridge DC-DC Converter Using Metaheuristic Algorithms
This study proposes an optimization approach based on metaheuristic algorithms to improve the control performance of a bidirectional dual active bridge (DAB) DC-DC converter. DAB converters are widely preferred in many applications due to their high efficiency, flexible control, and bidirectional power transfer capabilities. However, accurate determination of controller parameters is critical for achieving efficient energy transfer and minimizing losses. In this study, the DAB converter is controlled using proportional-integral (PI) and fractional-order proportional-integral (FOPI) controller structures. The controller parameters are optimized using Dandelion Optimization (DO), Particle Swarm Optimization (PSO), and Grey Wolf Optimization (GWO) algorithms, with the Integrated Time-Weighted Absolute Error (ITAE) employed as the objective function. In addition, the effects of circuit parameter selection on system efficiency are investigated. The results provide a comparative evaluation of the three algorithms and confirm the effectiveness of metaheuristic optimization in improving DAB converter control performance, contributing a comprehensive perspective to the existing literature.
- 16 January 2026
- Published by Karadeniz Fen Bilimleri Dergisi in Karadeniz Fen Bilimleri Dergisi
- Vol. 16 (1) , 304-337
Open AccessDetermination of Control Parameters of a Bidirectional Dual Active Bridge DC-DC Converter Using Metaheuristic Algorithms
This study proposes an optimization approach based on metaheuristic algorithms to improve the control performance of a bidirectional dual active bridge (DAB) DC-DC converter. DAB converters are widely preferred in many applications due to their high efficiency, flexible control, and bidirectional power transfer capabilities. However, accurate determination of controller parameters is critical for achieving efficient energy transfer and minimizing losses. In this study, the DAB converter is controlled using proportional-integral (PI) and fractional-order proportional-integral (FOPI) controller structures. The controller parameters are optimized using Dandelion Optimization (DO), Particle Swarm Optimization (PSO), and Grey Wolf Optimization (GWO) algorithms, with the Integrated Time-Weighted Absolute Error (ITAE) employed as the objective function. In addition, the effects of circuit parameter selection on system efficiency are investigated. The results provide a comparative evaluation of the three algorithms and confirm the effectiveness of metaheuristic optimization in improving DAB converter control performance, contributing a comprehensive perspective to the existing literature.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- p. 1
EV Charging Station Siting with Demand, Service Quality, and Charger Type Considerations
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- p. 1
Open AccessEV Charging Station Siting with Demand, Service Quality, and Charger Type Considerations
- 26 June 2025
- Published by AVES YAYINCILIK A.Ş. in Electrica
- Vol. 25 (1) , 1-16
Comparative Analysis of Metaheuristic Algorithms in PID-Based Vehicle Cruise Control Systems
This study presents a comparative analysis of five metaheuristic algorithms for optimizing Proportional Integral Derivative (PID) controller parameters in a vehicle cruise control system. The selected algorithms include the Rain Optimization Algorithm (ROA), Student Psychology-Based Optimization (SPBO), Sine Cosine Algorithm (SCA), Gradient-Based Optimization (GBO), and Grey Wolf Optimization (GWO). The PID parameters are optimized using four common performance criteria: Integral Time Absolute Error (ITAE), Integral Absolute Error (IAE), Integral SquareError (ISE), and Integral Time Square Error (ITSE). Unlike conventional tuning methods, metaheuristic approaches provide more flexible and adaptive parameter selection, enhancing the control system's robustness. The study analyses the algorithms under several internal and external disturbances, including road incline, passenger mass, and measurement noise. The findings demonstrate that no singular algorithm is universally superior; instead, efficacy is contingent upon the particular system conditions and control objectives. The Sine Conine Algorithm (SCA) has superior overall performance under typical settings, while GWO attains the quickest response time for slope fluctuations. Conversely, ROA reduces overshoot, rendering it appropriate for applications that necessitate stability. Additionally, the proposed methods are compared with the classical Ziegler-Nichols tuning approach, demonstrating the advantages of metaheuristic algorithms in terms of reduced overshoot, faster settling time, and improved robustness. The findings indicate that the SCA with the ITAE criterion yields superior performance under varying disturbance conditions. However, the fastest system response under different slope conditions isachieved with the parameter values determined by the GWO employing the ITSE criterion. The system model is designed in a MATLAB environment and the detailed comparative results are provided in figures and tables.Cite this article as: F. Heybetli, Y. Danayiyen, A. Begüm Taşdemir and Ş. Şenyiğit, "Comparative analysis of metaheuristic algorithms in PID-based vehicle cruisecontrol systems," Electrica, 25, 0051, 2025. doi: 10.5152/electrica.2025.24051.
- 26 June 2025
- Published by AVES YAYINCILIK A.Ş. in Electrica
- Vol. 25 (1) , 1-16
Comparative Analysis of Metaheuristic Algorithms in PID-Based Vehicle Cruise Control Systems
This study presents a comparative analysis of five metaheuristic algorithms for optimizing Proportional Integral Derivative (PID) controller parameters in a vehicle cruise control system. The selected algorithms include the Rain Optimization Algorithm (ROA), Student Psychology-Based Optimization (SPBO), Sine Cosine Algorithm (SCA), Gradient-Based Optimization (GBO), and Grey Wolf Optimization (GWO). The PID parameters are optimized using four common performance criteria: Integral Time Absolute Error (ITAE), Integral Absolute Error (IAE), Integral SquareError (ISE), and Integral Time Square Error (ITSE). Unlike conventional tuning methods, metaheuristic approaches provide more flexible and adaptive parameter selection, enhancing the control system's robustness. The study analyses the algorithms under several internal and external disturbances, including road incline, passenger mass, and measurement noise. The findings demonstrate that no singular algorithm is universally superior; instead, efficacy is contingent upon the particular system conditions and control objectives. The Sine Conine Algorithm (SCA) has superior overall performance under typical settings, while GWO attains the quickest response time for slope fluctuations. Conversely, ROA reduces overshoot, rendering it appropriate for applications that necessitate stability. Additionally, the proposed methods are compared with the classical Ziegler-Nichols tuning approach, demonstrating the advantages of metaheuristic algorithms in terms of reduced overshoot, faster settling time, and improved robustness. The findings indicate that the SCA with the ITAE criterion yields superior performance under varying disturbance conditions. However, the fastest system response under different slope conditions isachieved with the parameter values determined by the GWO employing the ITSE criterion. The system model is designed in a MATLAB environment and the detailed comparative results are provided in figures and tables.Cite this article as: F. Heybetli, Y. Danayiyen, A. Begüm Taşdemir and Ş. Şenyiğit, "Comparative analysis of metaheuristic algorithms in PID-based vehicle cruisecontrol systems," Electrica, 25, 0051, 2025. doi: 10.5152/electrica.2025.24051.
- Open Access
- 28 April 2025
- Published by AVES YAYINCILIK A.Ş. in Electrica
- Vol. 25 (1) , 1-16
Comparative Analysis of Metaheuristic Algorithms in PID-Based Vehicle Cruise Control Systems
This study presents a comparative analysis of five metaheuristic algorithms for optimizing Proportional Integral Derivative (PID) controller parameters in a vehicle cruise control system. The selected algorithms include the Rain Optimization Algorithm (ROA), Student Psychology-Based Optimization (SPBO), Sine Cosine Algorithm (SCA), Gradient-Based Optimization (GBO), and Grey Wolf Optimization (GWO). The PID parameters are optimized using four common performance criteria: Integral Time Absolute Error (ITAE), Integral Absolute Error (IAE), Integral Square Error (ISE), and Integral Time Square Error (ITSE). Unlike conventional tuning methods, metaheuristic approaches provide more flexible and adaptive parameter selection, enhancing the control system's robustness. The study analyses the algorithms under several internal and external disturbances, including road incline, passenger mass, and measurement noise. The findings demonstrate that no singular algorithm is universally superior; instead, efficacy is contingent upon the particular system conditions and control objectives. The Sine Conine Algorithm (SCA) has superior overall performance under typical settings, while GWO attains the quickest response time for slope fluctuations. Conversely, ROA reduces overshoot, rendering it appropriate for applications that necessitate stability. Additionally, the proposed methods are compared with the classical Ziegler-Nichols tuning approach, demonstrating the advantages of metaheuristic algorithms in terms of reduced overshoot, faster settling time, and improved robustness. The findings indicate that the SCA with the ITAE criterion yields superior performance under varying disturbance conditions. However, the fastest system response under different slope conditions is achieved with the parameter values determined by the GWO employing the ITSE criterion. The system model is designed in a MATLAB environment and the detailed comparative results are provided in figures and tables.Cite this article as: F. Heybetli, Y. Danayiyen, A. Begüm Taşdemir and Ş. Şenyiğit, "Comparative analysis of metaheuristic algorithms in PID-based vehicle cruise control systems," Electrica, 25, 0051, 2025. doi: 10.5152/electrica.2025.25051.
- 28 April 2025
- Published by AVES YAYINCILIK A.Ş. in Electrica
- Vol. 25 (1) , 1-16
Open AccessComparative Analysis of Metaheuristic Algorithms in PID-Based Vehicle Cruise Control Systems
This study presents a comparative analysis of five metaheuristic algorithms for optimizing Proportional Integral Derivative (PID) controller parameters in a vehicle cruise control system. The selected algorithms include the Rain Optimization Algorithm (ROA), Student Psychology-Based Optimization (SPBO), Sine Cosine Algorithm (SCA), Gradient-Based Optimization (GBO), and Grey Wolf Optimization (GWO). The PID parameters are optimized using four common performance criteria: Integral Time Absolute Error (ITAE), Integral Absolute Error (IAE), Integral Square Error (ISE), and Integral Time Square Error (ITSE). Unlike conventional tuning methods, metaheuristic approaches provide more flexible and adaptive parameter selection, enhancing the control system's robustness. The study analyses the algorithms under several internal and external disturbances, including road incline, passenger mass, and measurement noise. The findings demonstrate that no singular algorithm is universally superior; instead, efficacy is contingent upon the particular system conditions and control objectives. The Sine Conine Algorithm (SCA) has superior overall performance under typical settings, while GWO attains the quickest response time for slope fluctuations. Conversely, ROA reduces overshoot, rendering it appropriate for applications that necessitate stability. Additionally, the proposed methods are compared with the classical Ziegler-Nichols tuning approach, demonstrating the advantages of metaheuristic algorithms in terms of reduced overshoot, faster settling time, and improved robustness. The findings indicate that the SCA with the ITAE criterion yields superior performance under varying disturbance conditions. However, the fastest system response under different slope conditions is achieved with the parameter values determined by the GWO employing the ITSE criterion. The system model is designed in a MATLAB environment and the detailed comparative results are provided in figures and tables.Cite this article as: F. Heybetli, Y. Danayiyen, A. Begüm Taşdemir and Ş. Şenyiğit, "Comparative analysis of metaheuristic algorithms in PID-based vehicle cruise control systems," Electrica, 25, 0051, 2025. doi: 10.5152/electrica.2025.25051.
- 16 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
DC Microgrid Design for Aircraft
In this study, a DC microgrid design for airplanes and other aircraft is realized. In today's aircraft, the AA voltage generated by the generator rotated by the aircraft engine is converted to DC voltage and used to supply the DC loads in the aircraft. The quality and reliability of the DC voltage is very important for the critical loads in the aircraft. In this study, the AA voltage is converted to ±270V DC voltage and then to 28V DC voltage used in Boeing 787. Two DC/DC step-down converters were used to achieve this goal. A Gray Wolf Algorithm (GWO) based fractional order PID (FO-PID) controller is used to obtain small and high-quality voltage fluctuations at the outputs of the converters. In addition, a 28V load system was designed to generate the 28V DC microgrid portion used in airplanes. In this system, two DC motors of different power were used to represent the windshield wiper motors and fans in the ventilation systems, one lamp to represent the lighting and one resistance element to represent the resistances in the air conditioning systems. In this way, a high voltage DC microgrid with a voltage of ±270V and a low voltage DC microgrid with a voltage of 28V were created.
- 16 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
DC Microgrid Design for Aircraft
In this study, a DC microgrid design for airplanes and other aircraft is realized. In today's aircraft, the AA voltage generated by the generator rotated by the aircraft engine is converted to DC voltage and used to supply the DC loads in the aircraft. The quality and reliability of the DC voltage is very important for the critical loads in the aircraft. In this study, the AA voltage is converted to ±270V DC voltage and then to 28V DC voltage used in Boeing 787. Two DC/DC step-down converters were used to achieve this goal. A Gray Wolf Algorithm (GWO) based fractional order PID (FO-PID) controller is used to obtain small and high-quality voltage fluctuations at the outputs of the converters. In addition, a 28V load system was designed to generate the 28V DC microgrid portion used in airplanes. In this system, two DC motors of different power were used to represent the windshield wiper motors and fans in the ventilation systems, one lamp to represent the lighting and one resistance element to represent the resistances in the air conditioning systems. In this way, a high voltage DC microgrid with a voltage of ±270V and a low voltage DC microgrid with a voltage of 28V were created.
- 16 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Internal Consumption Vehicle Speed Control with Rain Optimization Algorithm Based PID Controller
In this study, a proportional-integral-derivative (PID) controller is designed in MATLAB/SIMULINK to facilitate vehicle cruise control (VCC) system, specifically regulating and maintaining the vehicle's speed at a predefined value. The parameter values of the controller are determined through the utilization of five different metaheuristic algorithms: Student Psychology Based Optimization (SPBO) algorithm, Sine Cosine Optimization (SCA) algorithm, Rain Optimization Algorithm (ROA), Gradient Based Optimization (GBO) algorithm, and Gray Wolf Optimization (GWO) algorithm. A comprehensive performance analysis of the devised system is provided. Furthermore, to assess the robustness of the proposed controller, a sinusoidal noise-based disturbance effect is incorporated into the mathematical model of the vehicle.
- 16 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Internal Consumption Vehicle Speed Control with Rain Optimization Algorithm Based PID Controller
In this study, a proportional-integral-derivative (PID) controller is designed in MATLAB/SIMULINK to facilitate vehicle cruise control (VCC) system, specifically regulating and maintaining the vehicle's speed at a predefined value. The parameter values of the controller are determined through the utilization of five different metaheuristic algorithms: Student Psychology Based Optimization (SPBO) algorithm, Sine Cosine Optimization (SCA) algorithm, Rain Optimization Algorithm (ROA), Gradient Based Optimization (GBO) algorithm, and Gray Wolf Optimization (GWO) algorithm. A comprehensive performance analysis of the devised system is provided. Furthermore, to assess the robustness of the proposed controller, a sinusoidal noise-based disturbance effect is incorporated into the mathematical model of the vehicle.
- Open Access
- 19 August 2024
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2024 (8)
Symmetrical components‐based robust stabilizing control of a grid‐connected inverter under unbalanced voltage sag
This study presents an approach for robust current and power control for a three‐phase grid‐connected inverter set up with an L‐filter that operates under an unbalanced AC grid‐voltage source. This control method consists of two paralleled current control for the positive and negative sequences to accomplish one of three selective control targets: a) supplying balanced three‐phase current; b) supplying non‐oscillated real power; and c) supplying non‐oscillated imaginary power to the AC grid for a given reference value utilizing the identical control gains. The real and imaginary power references, together with the measured grid voltages, are used in the computation of the reference current for each control target. In addition, the proposed dual‐current control system has a control law that comprises state feedback to offer stability and an integral effect to get rid of the offset error in the dq ‐frame. To reduce settling time under uncertain system conditions, an optimization problem based on linear matrix inequalities is solved to determine a set of robust stabilizing gains. Simulation and experimental results using a TMS320F28377D digital signal processor validate the proposed control performance under three control targets.
- 19 August 2024
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2024 (8)
Open AccessSymmetrical components‐based robust stabilizing control of a grid‐connected inverter under unbalanced voltage sag
This study presents an approach for robust current and power control for a three‐phase grid‐connected inverter set up with an L‐filter that operates under an unbalanced AC grid‐voltage source. This control method consists of two paralleled current control for the positive and negative sequences to accomplish one of three selective control targets: a) supplying balanced three‐phase current; b) supplying non‐oscillated real power; and c) supplying non‐oscillated imaginary power to the AC grid for a given reference value utilizing the identical control gains. The real and imaginary power references, together with the measured grid voltages, are used in the computation of the reference current for each control target. In addition, the proposed dual‐current control system has a control law that comprises state feedback to offer stability and an integral effect to get rid of the offset error in the dq ‐frame. To reduce settling time under uncertain system conditions, an optimization problem based on linear matrix inequalities is solved to determine a set of robust stabilizing gains. Simulation and experimental results using a TMS320F28377D digital signal processor validate the proposed control performance under three control targets.
- Open Access
Model Predictive Control of Uninterruptible Power Supply with Robust Disturbance Observer
This paper presents a robust continuous control set model predictive control (CCS-MPC) method to control the output voltage of a three-phase inverter in uninterruptible power supplies (UPS). A robust disturbance observer (DOB) is proposed to estimate the load current of the three-phase UPS without a steady-state error, taking the effect of model uncertainties into account. A CCS-MPC is designed using the DOB for reference voltage tracking purpose, and input constraints are considered in the controller design to calculate the optimal control input. Model uncertainties are defined using polytopic uncertainty class, and a linear matrix inequality (LMI) optimization method is used to compute the optimal observer gain matrix. Another robust controller (RC) is designed based on the DOB and compared with CCS-MPC. The effectiveness of the proposed method (the DOB based CCS-MPC) is evaluated for resistive, inductive, and nonlinear loads then compared with other control methods using a three-phase 5-KVA laboratory experiment UPS system.
Open AccessModel Predictive Control of Uninterruptible Power Supply with Robust Disturbance Observer
This paper presents a robust continuous control set model predictive control (CCS-MPC) method to control the output voltage of a three-phase inverter in uninterruptible power supplies (UPS). A robust disturbance observer (DOB) is proposed to estimate the load current of the three-phase UPS without a steady-state error, taking the effect of model uncertainties into account. A CCS-MPC is designed using the DOB for reference voltage tracking purpose, and input constraints are considered in the controller design to calculate the optimal control input. Model uncertainties are defined using polytopic uncertainty class, and a linear matrix inequality (LMI) optimization method is used to compute the optimal observer gain matrix. Another robust controller (RC) is designed based on the DOB and compared with CCS-MPC. The effectiveness of the proposed method (the DOB based CCS-MPC) is evaluated for resistive, inductive, and nonlinear loads then compared with other control methods using a three-phase 5-KVA laboratory experiment UPS system.