Jesús Marín
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jesús Marín has a total of 142 co-authors. Here are the top co-authors by number of shared publications:
- Cecilia Pizzolotto
Sezione INFN di Trieste, Via A. Valerio 2, Trieste, Italy
3 shared publications - Eugenio Berti
INFN Firenze, Via Sansone 1, 50019 Sesto Fiorentino, FI, Italy
3 shared publications - Gustavo Martinez
CIEMAT
3 shared publications - Jorge Casaus
Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (CIEMAT), E-28040 Madrid, Spain
3 shared publications - Lorenzo Pacini
Università di Firenze, Dipartimento di Fisica e Astronomia, via Sansone 1, Sesto Fiorentino, 50019 Italy
3 shared publications - Miguel Angel Velasco
Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (CIEMAT), Avda. Complutense 40, Madrid, Spain
3 shared publications
Latest Publications
- Open Access
- 22 January 2024
- Published by MDPI AG in Instruments
- Vol. 8 (1) , 5
Double Photodiode Readout System for the Calorimeter of the HERD Experiment: Challenges and New Horizons in Technology for the Direct Detection of High-Energy Cosmic Rays
The HERD experiment is a future experiment for the direct detection of high-energy cosmic rays and is to be installed on the Chinese space station in 2027. The main objectives of HERD are the first direct measurement of the knee of the cosmic ray spectrum, the extension of electron+positron flux measurement up to tens of TeV, gamma ray astronomy, and the search for indirect signals of dark matter. The main component of the HERD detector is an innovative calorimeter composed of about 7500 LYSO scintillating crystals assembled in a spherical shape. Two independent readout systems of the LYSO scintillation light will be installed on each crystal: the wavelength-shifting fibers system developed by IHEP and the double photodiode readout system developed by INFN and CIEMAT. In order to measure protons in the cosmic ray knee region, we must be able to measure energy release of about 250 TeV in a single crystal. In addition, in order to calibrate the system, we need to measure typical releases of minimum ionizing particles that are about 30 MeV. Thus, the readout systems should have a dynamic range of about . In this article, we analyze the development and the performance of the double photodiode readout system. In particular, we show the performance of a prototype readout by the double photodiode system for electromagnetic showers as measured during a beam test carried out at the CERN SPS in October 2021 with high-energy electron beams.- 22 January 2024
- Published by MDPI AG in Instruments
- Vol. 8 (1) , 5
Open AccessDouble Photodiode Readout System for the Calorimeter of the HERD Experiment: Challenges and New Horizons in Technology for the Direct Detection of High-Energy Cosmic Rays
The HERD experiment is a future experiment for the direct detection of high-energy cosmic rays and is to be installed on the Chinese space station in 2027. The main objectives of HERD are the first direct measurement of the knee of the cosmic ray spectrum, the extension of electron+positron flux measurement up to tens of TeV, gamma ray astronomy, and the search for indirect signals of dark matter. The main component of the HERD detector is an innovative calorimeter composed of about 7500 LYSO scintillating crystals assembled in a spherical shape. Two independent readout systems of the LYSO scintillation light will be installed on each crystal: the wavelength-shifting fibers system developed by IHEP and the double photodiode readout system developed by INFN and CIEMAT. In order to measure protons in the cosmic ray knee region, we must be able to measure energy release of about 250 TeV in a single crystal. In addition, in order to calibrate the system, we need to measure typical releases of minimum ionizing particles that are about 30 MeV. Thus, the readout systems should have a dynamic range of about . In this article, we analyze the development and the performance of the double photodiode readout system. In particular, we show the performance of a prototype readout by the double photodiode system for electromagnetic showers as measured during a beam test carried out at the CERN SPS in October 2021 with high-energy electron beams. - Open Access
- 2 September 2022
- Published by MDPI AG in Instruments
- Vol. 6 (3) , 33
Photodiode Read-Out System for the Calorimeter of the Herd Experiment
HERD is a future experiment for the direct detection of high energy cosmic rays. The instrument is based on a calorimeter optimized not only for a good energy resolution but also for a large acceptance. Each crystal composing the calorimeter is equipped with two read-out systems: one based on wavelength-shifting fibers and the other based on two photodiodes with different active areas assembled in a monolithic package. In this paper, we describe the photodiode read-out system, focusing on experimental requirements, design and estimated performances. Finally, we show how these features lead to the flight model project of the photodiode read-out system.
- 2 September 2022
- Published by MDPI AG in Instruments
- Vol. 6 (3) , 33
Open AccessPhotodiode Read-Out System for the Calorimeter of the Herd Experiment
HERD is a future experiment for the direct detection of high energy cosmic rays. The instrument is based on a calorimeter optimized not only for a good energy resolution but also for a large acceptance. Each crystal composing the calorimeter is equipped with two read-out systems: one based on wavelength-shifting fibers and the other based on two photodiodes with different active areas assembled in a monolithic package. In this paper, we describe the photodiode read-out system, focusing on experimental requirements, design and estimated performances. Finally, we show how these features lead to the flight model project of the photodiode read-out system.
- Open Access
- 11 May 2022
- Published by MDPI AG in Instruments
- Vol. 6 (2) , 19
Design of an Antimatter Large Acceptance Detector In Orbit (ALADInO)
A new generation magnetic spectrometer in space will open the opportunity to investigate the frontiers in direct high-energy cosmic ray measurements and to precisely measure the amount of the rare antimatter component in cosmic rays beyond the reach of current missions. We propose the concept for an Antimatter Large Acceptance Detector In Orbit (ALADInO), designed to take over the legacy of direct measurements of cosmic rays in space performed by PAMELA and AMS-02. ALADInO features technological solutions conceived to overcome the current limitations of magnetic spectrometers in space with a layout that provides an acceptance larger than 10 m sr. A superconducting magnet coupled to precision tracking and time-of-flight systems can provide the required matter–antimatter separation capabilities and rigidity measurement resolution with a Maximum Detectable Rigidity better than 20 TV. The inner 3D-imaging deep calorimeter, designed to maximize the isotropic acceptance of particles, allows for the measurement of cosmic rays up to PeV energies with accurate energy resolution to precisely measure features in the cosmic ray spectra. The operations of ALADInO in the Sun–Earth L2 Lagrangian point for at least 5 years would enable unique revolutionary observations with groundbreaking discovery potentials in the field of astroparticle physics by precision measurements of electrons, positrons, and antiprotons up to 10 TeV and of nuclear cosmic rays up to PeV energies, and by the possible unambiguous detection and measurement of low-energy antideuteron and antihelium components in cosmic rays.- 11 May 2022
- Published by MDPI AG in Instruments
- Vol. 6 (2) , 19
Open AccessDesign of an Antimatter Large Acceptance Detector In Orbit (ALADInO)
A new generation magnetic spectrometer in space will open the opportunity to investigate the frontiers in direct high-energy cosmic ray measurements and to precisely measure the amount of the rare antimatter component in cosmic rays beyond the reach of current missions. We propose the concept for an Antimatter Large Acceptance Detector In Orbit (ALADInO), designed to take over the legacy of direct measurements of cosmic rays in space performed by PAMELA and AMS-02. ALADInO features technological solutions conceived to overcome the current limitations of magnetic spectrometers in space with a layout that provides an acceptance larger than 10 m sr. A superconducting magnet coupled to precision tracking and time-of-flight systems can provide the required matter–antimatter separation capabilities and rigidity measurement resolution with a Maximum Detectable Rigidity better than 20 TV. The inner 3D-imaging deep calorimeter, designed to maximize the isotropic acceptance of particles, allows for the measurement of cosmic rays up to PeV energies with accurate energy resolution to precisely measure features in the cosmic ray spectra. The operations of ALADInO in the Sun–Earth L2 Lagrangian point for at least 5 years would enable unique revolutionary observations with groundbreaking discovery potentials in the field of astroparticle physics by precision measurements of electrons, positrons, and antiprotons up to 10 TeV and of nuclear cosmic rays up to PeV energies, and by the possible unambiguous detection and measurement of low-energy antideuteron and antihelium components in cosmic rays. - Open Access
- 29 July 2021
- Published by MDPI AG in Electronics
- Vol. 10 (15) , 1816
MATRIX16: A 16-Channel Low-Power TDC ASIC with 8 ps Time Resolution
This paper presents a highly configurable 16-channel TDC ASIC designed in a commercial 180 nm technology with the following features: time-of-flight and time-over-threshold measurements, 8.6 ps LSB, 7.7 ps jitter, 5.6 ps linearity error, up to 5 MHz of sustained input rate per channel, 9.1 mW of power consumption per channel, and an area of 4.57 mm. The main contributions of this work are the novel design of the clock interpolation circuitry based on a resistive interpolation mesh circuit and the capability to operate at different supply voltages and operating frequencies, thus providing a compromise between TDC resolution and power consumption.- 29 July 2021
- Published by MDPI AG in Electronics
- Vol. 10 (15) , 1816
Open AccessMATRIX16: A 16-Channel Low-Power TDC ASIC with 8 ps Time Resolution
This paper presents a highly configurable 16-channel TDC ASIC designed in a commercial 180 nm technology with the following features: time-of-flight and time-over-threshold measurements, 8.6 ps LSB, 7.7 ps jitter, 5.6 ps linearity error, up to 5 MHz of sustained input rate per channel, 9.1 mW of power consumption per channel, and an area of 4.57 mm. The main contributions of this work are the novel design of the clock interpolation circuitry based on a resistive interpolation mesh circuit and the capability to operate at different supply voltages and operating frequencies, thus providing a compromise between TDC resolution and power consumption. - Open Access
- 21 May 2019
- Published by Sissa Medialab Srl
- Vol. 343, 085
A High Dynamic Range ASIC for Time of Flight PET with monolithic crystals
The HRFlexToT is a 16-channel ASIC for SiPM anode readout designed for Positron Emission Tomography (PET) applications that features high dynamic range (>8 bits), low input impedance, common cathode connection, high speed and low power (~3.5 mW/ch). The ASIC has been manufactured using XFAB 0.18 mm CMOS technology. The main characteristics of the HRFlexToT, compared to its predecessor, are a new energy measurement readout providing a linear Time Over Threshold (ToT) with an extended dynamic range, lower power consumption and better timing response. Initial measurements show a linearity error below 3%. Single Photon Time Resolution (SPTR) measurements performed using a Hamamatsu MPPC S13360-3050CS (3x3 mm2 pixel, 50 umm cell) shows 30% improvement with respect to the previous version of the ASIC, setting this specification in the order of 141 ps FWHM and reducing 3 times power consumption. It is important to highlight that an SPTR of 141 ps FWHM is, according to the best of our knowledge, the best resolution achieved so far for this sensor. Coincidence Time Resolution (CTR) measurements are expected to be performed during 2018.
- 21 May 2019
- Published by Sissa Medialab Srl
- Vol. 343, 085
Open AccessA High Dynamic Range ASIC for Time of Flight PET with monolithic crystals
The HRFlexToT is a 16-channel ASIC for SiPM anode readout designed for Positron Emission Tomography (PET) applications that features high dynamic range (>8 bits), low input impedance, common cathode connection, high speed and low power (~3.5 mW/ch). The ASIC has been manufactured using XFAB 0.18 mm CMOS technology. The main characteristics of the HRFlexToT, compared to its predecessor, are a new energy measurement readout providing a linear Time Over Threshold (ToT) with an extended dynamic range, lower power consumption and better timing response. Initial measurements show a linearity error below 3%. Single Photon Time Resolution (SPTR) measurements performed using a Hamamatsu MPPC S13360-3050CS (3x3 mm2 pixel, 50 umm cell) shows 30% improvement with respect to the previous version of the ASIC, setting this specification in the order of 141 ps FWHM and reducing 3 times power consumption. It is important to highlight that an SPTR of 141 ps FWHM is, according to the best of our knowledge, the best resolution achieved so far for this sensor. Coincidence Time Resolution (CTR) measurements are expected to be performed during 2018.