Soon Young Yun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Soon Young Yun has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Shin Hyung Kim
Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul 03722, Republic of Korea
2 shared publications - Bon-Nyeo Koo
Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Korea
1 shared publication Bora Lee
Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Yonsei-ro, Seodaemun-Gu, Seoul, Republic of Korea
1 shared publicationDo Heon Kim
Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
1 shared publication- Duck Mi Yoon
Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Korea
1 shared publication - Go Eun Kim
Department of Anesthesiology and Pain Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
1 shared publication
Latest Publications
- Open Access
- 1 January 2019
- Published by XMLink in Yonsei Medical Journal
- Vol. 60 (8) , 735-741
Accuracy and Efficacy of Impedance Cardiography as a Non-Invasive Cardiac Function Monitor
The most common method of monitoring cardiac output (CO) is thermodilution using pulmonary artery catheter (PAC), but this method is associated with complications. Impedance cardiography (ICG) is a non-invasive CO monitoring technique. This study compared the accuracy and efficacy of ICG as a non-invasive cardiac function monitoring technique to those of thermodilution and arterial pressure contour. Sixteen patients undergoing liver transplantation were included. Cardiac index (CI) was measured by thermodilution using PAC, arterial waveform analysis, and ICG simultaneously in each patient. Statistical analysis was performed using intraclass correlation coefficient (ICC) and Bland-Altman analysis to assess the degree of agreement. The difference by thermodilution and ICG was 1.13 L/min/m², and the limits of agreement were -0.93 and 3.20 L/min/m². The difference by thermodilution and arterial pressure contour was 0.62 L/min/m², and the limits of agreement were -1.43 and 2.67 L/min/m². The difference by arterial pressure contour and ICG was 0.50 L/min/m², and the limits of agreement were -1.32 and 2.32 L/min/m². All three percentage errors exceeded the 30% limit of acceptance. Substantial agreement was observed between CI of thermodilution with PAC and ICG at preanhepatic and anhepatic phases, as well as between CI of thermodilution and arterial waveform analysis at preanhepatic phase. Others showed moderate agreement. Although neither method was clinically equivalent to thermodilution, ICG showed more substantial correlation with thermodilution method than with arterial waveform analysis. As a non-invasive cardiac function monitor, ICG would likely require further studies in other settings.
- 1 January 2019
- Published by XMLink in Yonsei Medical Journal
- Vol. 60 (8) , 735-741
Open AccessAccuracy and Efficacy of Impedance Cardiography as a Non-Invasive Cardiac Function Monitor
The most common method of monitoring cardiac output (CO) is thermodilution using pulmonary artery catheter (PAC), but this method is associated with complications. Impedance cardiography (ICG) is a non-invasive CO monitoring technique. This study compared the accuracy and efficacy of ICG as a non-invasive cardiac function monitoring technique to those of thermodilution and arterial pressure contour. Sixteen patients undergoing liver transplantation were included. Cardiac index (CI) was measured by thermodilution using PAC, arterial waveform analysis, and ICG simultaneously in each patient. Statistical analysis was performed using intraclass correlation coefficient (ICC) and Bland-Altman analysis to assess the degree of agreement. The difference by thermodilution and ICG was 1.13 L/min/m², and the limits of agreement were -0.93 and 3.20 L/min/m². The difference by thermodilution and arterial pressure contour was 0.62 L/min/m², and the limits of agreement were -1.43 and 2.67 L/min/m². The difference by arterial pressure contour and ICG was 0.50 L/min/m², and the limits of agreement were -1.32 and 2.32 L/min/m². All three percentage errors exceeded the 30% limit of acceptance. Substantial agreement was observed between CI of thermodilution with PAC and ICG at preanhepatic and anhepatic phases, as well as between CI of thermodilution and arterial waveform analysis at preanhepatic phase. Others showed moderate agreement. Although neither method was clinically equivalent to thermodilution, ICG showed more substantial correlation with thermodilution method than with arterial waveform analysis. As a non-invasive cardiac function monitor, ICG would likely require further studies in other settings.
- Open Access
- 16 December 2018
- Published by SAGE Publications in Journal of International Medical Research
- Vol. 47 (1) , 235-243
Insertion depth of nasotracheal tubes sized to fit the nostril: an observational study
Objective: Nasotracheal (NT) intubation is commonly applied during head and neck surgery. However, improper tube size and depth may cause complications. In the current study, we investigated whether NT tubes are being appropriately used in terms of size and depth in adult patients. Methods: Nares were sized in 40 patients using standard nasopharyngeal airways (6.0–8.0) before elective surgery under general anesthesia. The largest sized airway that passed easily into the nasopharynx without resistance was considered as a proper size. Using a fiberoptic scope, the distances from the nares to the vocal cords and the nares to the carina were measured. Rates of proper NT tube positioning were calculated with regard to the cuff and distal tip. Results: The most frequent sizes of properly fitted NT tubes were 6.5 and 6.0 in male and female patients, respectively. Positioning of the cuff and distal tip was only appropriate when using a properly sized tube in 26% and 47% of male and female patients, respectively. Conclusion: Care should be taken to determine the insertion depth after placing an NT tube that has been sized to fit the nostril. Moreover, NT tubes of the same diameter may be required in various lengths. Trial registration: Registered at ClinicalTrial.gov; https://clinicaltrials.gov/ct2/show/NCT02876913 ; Registration number NCT02876913
- 16 December 2018
- Published by SAGE Publications in Journal of International Medical Research
- Vol. 47 (1) , 235-243
Open AccessInsertion depth of nasotracheal tubes sized to fit the nostril: an observational study
Objective: Nasotracheal (NT) intubation is commonly applied during head and neck surgery. However, improper tube size and depth may cause complications. In the current study, we investigated whether NT tubes are being appropriately used in terms of size and depth in adult patients. Methods: Nares were sized in 40 patients using standard nasopharyngeal airways (6.0–8.0) before elective surgery under general anesthesia. The largest sized airway that passed easily into the nasopharynx without resistance was considered as a proper size. Using a fiberoptic scope, the distances from the nares to the vocal cords and the nares to the carina were measured. Rates of proper NT tube positioning were calculated with regard to the cuff and distal tip. Results: The most frequent sizes of properly fitted NT tubes were 6.5 and 6.0 in male and female patients, respectively. Positioning of the cuff and distal tip was only appropriate when using a properly sized tube in 26% and 47% of male and female patients, respectively. Conclusion: Care should be taken to determine the insertion depth after placing an NT tube that has been sized to fit the nostril. Moreover, NT tubes of the same diameter may be required in various lengths. Trial registration: Registered at ClinicalTrial.gov; https://clinicaltrials.gov/ct2/show/NCT02876913 ; Registration number NCT02876913
- 1 February 2017
- Published by Wolters Kluwer Health in American Journal of Physical Medicine & Rehabilitation
- Vol. 96 (2) , e14-e19
The Effect of Skin Pressure on Needle Entry Point Accuracy During Fluoroscopically Guided Lumbar Transforaminal Epidural Injections
The aim of this study was to investigate the effect of skin pressure on needle entry point accuracy during fluoroscopically guided lumbar transforaminal epidural injection. This study is a prospective randomized clinical trial; 64 patients with a body mass index of 25 kg/m2 or greater were enrolled. For patients in the pressing group, the operator marked the needle entry point on the patient’s back while pressing the patient’s skin with the tip of an indicator. For patients in the nonpressing group, the tip of the indicator was gently positioned on the patient’s skin. The data related to technical performance and radiation exposure during the procedure were compared. Sixty patients (nonpressing group, n = 30; pressing group, n = 30) were analyzed. There were more attempts to reposition the needle (n) and increased procedure time (in seconds) in the pressing group (median, 5 vs. 4 [P = 0.019]; 400.0 vs. 358.5 [P = 0.033]). The fluoroscopy time (in seconds) and the kerma-area product (in cGy cm2) were also significantly longer and greater in the pressing group, respectively (median, 63.5 vs. 50.5 [P = 0.038]; 416.3 vs. 318.6 [P = 0.014]). This study shows that practitioners should not press the skin with a radiopaque indicator when determining the needle entry point by fluoroscopy during lumbar transforaminal epidural injection.
- 1 February 2017
- Published by Wolters Kluwer Health in American Journal of Physical Medicine & Rehabilitation
- Vol. 96 (2) , e14-e19
The Effect of Skin Pressure on Needle Entry Point Accuracy During Fluoroscopically Guided Lumbar Transforaminal Epidural Injections
The aim of this study was to investigate the effect of skin pressure on needle entry point accuracy during fluoroscopically guided lumbar transforaminal epidural injection. This study is a prospective randomized clinical trial; 64 patients with a body mass index of 25 kg/m2 or greater were enrolled. For patients in the pressing group, the operator marked the needle entry point on the patient’s back while pressing the patient’s skin with the tip of an indicator. For patients in the nonpressing group, the tip of the indicator was gently positioned on the patient’s skin. The data related to technical performance and radiation exposure during the procedure were compared. Sixty patients (nonpressing group, n = 30; pressing group, n = 30) were analyzed. There were more attempts to reposition the needle (n) and increased procedure time (in seconds) in the pressing group (median, 5 vs. 4 [P = 0.019]; 400.0 vs. 358.5 [P = 0.033]). The fluoroscopy time (in seconds) and the kerma-area product (in cGy cm2) were also significantly longer and greater in the pressing group, respectively (median, 63.5 vs. 50.5 [P = 0.038]; 416.3 vs. 318.6 [P = 0.014]). This study shows that practitioners should not press the skin with a radiopaque indicator when determining the needle entry point by fluoroscopy during lumbar transforaminal epidural injection.
- Open Access
- 1 January 2017
- Published by Ivyspring International Publisher in International Journal of Medical Sciences
- Vol. 14 (6) , 536-542
Clinical insomnia and associated factors in failed back surgery syndrome: a retrospective cross-sectional study
Background Insomnia frequently occurs to patients with persistent back pain. By worsening pain, mood, and physical functioning, insomnia could lead to the negative clinical consequences of patients with failed back surgery syndrome (FBSS). This retrospective and cross-sectional study aims to identify the risk factors associated with clinical insomnia in FBSS patients.
- 1 January 2017
- Published by Ivyspring International Publisher in International Journal of Medical Sciences
- Vol. 14 (6) , 536-542
Open AccessClinical insomnia and associated factors in failed back surgery syndrome: a retrospective cross-sectional study
Background Insomnia frequently occurs to patients with persistent back pain. By worsening pain, mood, and physical functioning, insomnia could lead to the negative clinical consequences of patients with failed back surgery syndrome (FBSS). This retrospective and cross-sectional study aims to identify the risk factors associated with clinical insomnia in FBSS patients.
- Open Access
- 1 January 2013
- Published by Korean Breast Cancer Society in Journal of Breast Cancer
- Vol. 16 (1) , 127-128
Profound Hypotension after an Intradermal Injection of Indigo Carmine for Sentinel Node Mapping
Jo YY, et al. J Breast Cancer. 2013 Mar;16(1):127-128. http://dx.doi.org/10.4048/jbc.2013.16.1.127
- 1 January 2013
- Published by Korean Breast Cancer Society in Journal of Breast Cancer
- Vol. 16 (1) , 127-128
Open AccessProfound Hypotension after an Intradermal Injection of Indigo Carmine for Sentinel Node Mapping
Jo YY, et al. J Breast Cancer. 2013 Mar;16(1):127-128. http://dx.doi.org/10.4048/jbc.2013.16.1.127
- Open Access
- 1 January 2013
- Published by The Korean Society of Anesthesiologists in Korean Journal of Anesthesiology
- Vol. 65 (1) , 14-18
The effect of warmed inspired gases on body temperature during arthroscopic shoulder surgery under general anesthesia
Perioperative hypothermia can develop easily during shoulder arthroscopy, because cold irrigation can directly influence core body temperature. The authors investigated whether active warming and humidification of inspired gases reduces falls in core body temperature and allows redistribution of body heat in patients undergoing arthroscopic shoulder surgery under general anesthesia. Patients scheduled for arthroscopic shoulder surgery were randomly assigned to receive either room temperature inspired gases using a conventional respiratory circuit (the control group, n = 20) or inspired gases humidified and heated using a humidified and electrically heated circuit (HHC) (the heated group, n = 20). Core temperatures were significantly lower in both groups from 30 min after anesthesia induction, but were significantly higher in the heated group than in the control group from 75 to 120 min after anesthesia induction. In this study the use of a humidified and electrically heated circuit did not prevent core temperature falling during arthroscopic shoulder surgery, but it was found to decrease reductions in core temperature from 75 min after anesthesia induction.
- 1 January 2013
- Published by The Korean Society of Anesthesiologists in Korean Journal of Anesthesiology
- Vol. 65 (1) , 14-18
Open AccessThe effect of warmed inspired gases on body temperature during arthroscopic shoulder surgery under general anesthesia
Perioperative hypothermia can develop easily during shoulder arthroscopy, because cold irrigation can directly influence core body temperature. The authors investigated whether active warming and humidification of inspired gases reduces falls in core body temperature and allows redistribution of body heat in patients undergoing arthroscopic shoulder surgery under general anesthesia. Patients scheduled for arthroscopic shoulder surgery were randomly assigned to receive either room temperature inspired gases using a conventional respiratory circuit (the control group, n = 20) or inspired gases humidified and heated using a humidified and electrically heated circuit (HHC) (the heated group, n = 20). Core temperatures were significantly lower in both groups from 30 min after anesthesia induction, but were significantly higher in the heated group than in the control group from 75 to 120 min after anesthesia induction. In this study the use of a humidified and electrically heated circuit did not prevent core temperature falling during arthroscopic shoulder surgery, but it was found to decrease reductions in core temperature from 75 min after anesthesia induction.