Alexandra Delvallée

Alexandra Delvallée

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Alexandra Delvallée has a total of 321 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A FAIR road to a bioAFM databank

    by Jean-Luc Pellequer, Sebastian Aguayo, Andrea Alessandrini, David Alsteens, Toshio Ando, Audrey Beaussart, Michael Betton, Timo Betz, Kerstin G. Blank, Simone Bovio, et al.


  • Open Access

    Toward a Correlative Metrology Approach on the Same 2D Flake: Graphene Oxide Case Study—Sample Preparation and Stability Issues

    by Lydia Chibane, Alexandra Delvallée, Nolwenn Fleurence, Sarah Douri, José Morán-Meza, Christian Ulysse, François Piquemal, Nicolas Feltin, Emmanuel Flahaut

    Although graphene promises a wide range of applications, large-scale production of this material remains complex. One very common way of obtaining graphene is through a reduction in graphene oxide (GO). In order to fully control this production process, it is necessary to obtain data from different techniques, but a comprehensive characterization methodology and associated metrology are currently lacking. Here, we propose tools for substrate selection (in this study, the most appropriate were silicon and silicon dioxide on silicon) and precautions to be taken when setting up a correlative metrology method integrating atomic force microscopy (AFM), scanning electron microscopy (SEM), Raman microscopy/spectroscopy, scanning microwave microscopy (SMM) and scanning thermal microscopy (SThM). Indeed, in order to obtain reliable data for each of these techniques applied to a unique graphene oxide flake, a strategy must be developed and could be implemented to monitor the reduction in GO. Emphasis was placed on the choice of the substrate and on the possible degradations generated by each of the techniques employed, and a running sequence was determined.


  • Open Access

    Measurement of wettability and surface roughness for metrology and quality control in microfluidics

    by Thomas Schrøder Daugbjerg, Loïc Crouzier, Alexandra Delvallée, Florestan Ogheard, Christina Pecnik, Kevin Romieu, Fernanda Saraiva, Elsa Batista

    Microfluidics is a rapidly growing technology with applications in biochemistry and life sciences. To support the ongoing growth there is a need for common metrology, quality control, and standardisation. Here measurements of wettability and surface roughness can contribute, and these quantities affect flow characteristics of devices, bonding processes in manufacturing, and special microfluidic mechanisms such as droplet formation and spreading of fluids on surfaces. To quantify wettability, an optical laboratory setup was used to measure liquid drop contact angles of three liquids on a microfluidic surface. To further quantify wettability, the Owens, Wendt, Rabel, and Kaelble model was applied to contact angle measurements to determine the total surface free energy. To quantify surface roughness, atomic force microscopy and stylus profilometry measured area roughness parameter and profile roughness parameter for four samples of microfluidic surfaces. The wettability methods successfully demonstrated measurements of contact angles, and these methods were applied to determine a value for the total surface free energy. AFM and stylus profilometry successfully determined surface roughness parameters, and the determined values agreed with the expected for the material. In conclusion, the demonstrated methods can contribute to metrology, quality control and standardisation in microfluidics.


  • Open Access

    AFM interlaboratory comparison for nanodimensional metrology on silicon nanowires

    by Luigi Ribotta, Alexandra Delvallée, Eleonora Cara, Roberto Bellotti, Andrea Giura, Ivan De Carlo, Matteo Fretto, Walter Knulst, Richard Koops, Bruno Torre, et al.

    Silicon nanowires (NWs) with a cylindrical form are fabricated by means of nanosphere lithography and metal-assisted chemical etching to obtain high aspect ratio nanostructures (diameter of about 100 nm and length of more than 15 µm) on an approximately 1 cm2 area. The nanodimensional characterization of individual NWs is performed by using several techniques, because dimensions at the nanoscale strictly relate to functional performance. In this study, we report the results of an interlaboratory comparison between measurements from a metrological atomic force microscope (AFM) and research AFMs located in different national metrology institutes (NMIs) across Europe and in a university. The purpose of this study is to characterize two measurands: (i) sidewall roughness ( R a , R q , R z , R sk , R ku parameters) extracted from the top profile measured along the nanowire length, and (ii) diameter of the nanowires measured as top-height. To this goal, the nanowires are spread horizontally on a silicon substrate, which has several areas labelled with a pattern of crosses and letters facilitating the measurement of the same NW, in order to study the reproducibility due to different instruments. Measurements show a good agreement between the different NMIs, with a combined standard uncertainty of top-height diameter less than 3%, and with a combined standard uncertainty of roughness parameters well within 5% for R a and R q values.


  • Characterisation of titanium dioxide (nano)particles in foodstuffs and E171 additives by single particle inductively coupled plasma-tandem mass spectrometry using a highly efficient sample introduction system

    by Isabel Bastardo-Fernández, Rachida Chekri, Johanna Noireaux, Lucas Givelet, Nora Lambeng, Alexandra Delvallée, Katrin Loeschner, Paola Fisicaro, Petru Jitaru

    This study addressed primarily the characterisation and quantification of titanium dioxide (TiO2) (nano)particles (NPs) in a large variety of commercial foodstuffs. The samples were purchased from local markets in Spain before the ban of TiO2 food additive (E171) in the EU. The analyses were carried out by single particle inductively coupled plasma-tandem mass spectrometry (spICP-MS/MS) in mass shift mode (oxidation of 48Ti to 48Ti16O (m/z = 64)) and using a highly efficient sample introduction system (APEX™ Ω). This novel analytical approach allowed accurate characterisation of a large panel of TiO2 NPs sizes ranging from ∼12 to ∼800 nm without isobaric interferences from 48Ca isotope, which is highly abundant in most of the analysed foodstuffs. TiO2 NPs were extracted from foodstuffs using sodium dodecyl sulphate (0.1%, w/v) and diluted with ultra-pure water to reach ∼ 1000 particles signals per acquisition. All the analysed samples contained TiO2 NPs with concentrations ranging from 1010 to 1014 particles kg-1, but with significant low recoveries compared to the total Ti determination. A selection of samples was also analysed using a similar spICP-MS/MS approach with a conventional sample introduction system. The comparison of results highlighted the improvement of the limit of detection in size (12 nm) by the APEX™ Ω system, providing nanoparticulate fractions ranging from ∼4% (cheddar sauce) up to ∼87% (chewing gum), which is among the highest nanoparticulate fractions reported in literature using a spICP-MS approach. In addition, two commercially available E171 additives were analysed using the previous approaches and other techniques in different European laboratories with the aim of methods inter-comparison. This study provides occurrence data related to TiO2 NPs in common commercial foodstuffs but it also demonstrates the potential of the novel analytical approach based on APEX™-ICP-MS/MS to characterise nano-size TiO2 particles in complex matrices such as foodstuffs.


  • Open Access

    Strategy for Ensuring the Metrological Traceability of Nanoparticle Size Measurements by SEM

    by Nicolas Feltin, Alexandra Delvallée, Loïc Crouzier

    The concept of measurement traceability is crucial for ensuring the data reliability and the comparability of measurement results provided by different instruments and operators. In the field of nanoparticle metrology, determining the size of nanoparticles using electron microscopy-based techniques remains a real challenge. In laboratory settings, the establishment of traceability regarding the instrument calibration procedures, the assessment of uncertainties associated with instruments/operators/samples/environments, as well as the complexities related to electron–sample interactions, are often neglected. In this article, we describe the calibration procedure set up at the LNE (Laboratoire National de métrologie et d’Essais) and propose an evaluation method for determining the uncertainties in measuring nanoparticle size by SEM (Scanning Electron Microscopy). This study investigates the impact of the energy of the primary electrons (PEs) generated by the electron beam and accelerating voltage on the reliability of size measurements. The convolution between the signals coming from a nanoparticle and the substrate on which the particle is deposited induces edge effects that can have a negative impact on the measurement results. Finally, a diagram describing the various stages involved in establishing traceability for SEM measurements of nanoparticle size is proposed to facilitate the work of future operators.


  • Open Access

    Deep-reactive ion etching of silicon nanowire arrays at cryogenic temperatures

    by Jiushuai Xu, Andam Deatama Refino, Alexandra Delvallée, Sebastian Seibert, Christian Schwalb, Poul Erik Hansen, Martin Foldyna, Lauryna Siaudinyte, Gerry Hamdana, Hutomo Suryo Wasisto, et al.

    The pursuit of sculpting materials at increasingly smaller and deeper scales remains a persistent subject in the field of micro- and nanofabrication. Anisotropic deep-reactive ion etching of silicon at cryogenic temperatures (cryo-DRIE) was investigated for fabricating arrays of vertically aligned Si nanowires (NWs) of a large range of dimensions from micrometers down to 30 nm in diameter, combined with commonly used wafer-scale lithography techniques based on optical, electron-beam, nanoimprint, and nanosphere/colloidal masking. Large selectivity of ∼100 to 120 and almost 700 was found with resists and chromium hard masks, respectively. This remarkable selectivity enables the successful transfer of patterned geometries while preserving spatial resolution to a significant extent. Depending on the requirements by applications, various shapes, profiles, and aspect ratios were achieved by varying process parameters synchronously or asynchronously. High aspect ratios of up to 100 comparable to the best result by metal-assisted wet-chemical etching and sub-μm trenches by DRIE were obtained with NW diameter of 200 nm, at an etch rate of ∼4 μm/min without being collapsed. At the same time, low surface roughness values were maintained on the NW top, sidewall, and bottom surface of ∼0.3, ∼13, and ∼2 nm, respectively, as well as high pattern fidelity and integrity, which were measured using angle-resolved Fourier microscopy, combined atomic force, and scanning electron microscopy on selected NWs. This work establishes the foundation in the controllable development of Si nanoarchitectures, especially at sub-100 nm structures, for energy-harvesting and storage, damage-free optoelectronics, quantum, photovoltaics, and biomedical devices.


  • Open Access

    Thickness measurements of graphene oxide flakes using atomic force microscopy: results of an international interlaboratory comparison

    by Tianjia Bu, Huifang Gao, Yaxuan Yao, Jianfeng Wang, Andrew J Pollard, Elizabeth J Legge, Charles A Clifford, Alexandra Delvallée, Sébastien Ducourtieux, Malcolm A Lawn, et al.

    Flake thickness is one of the defining properties of graphene-related 2D materials (GR2Ms), and therefore requires reliable, accurate, and reproducible measurements with well-understood uncertainties. This is needed regardless of the production method or manufacturer because it is important for all GR2M products to be globally comparable. An international interlaboratory comparison on thickness measurements of graphene oxide flakes using atomic force microscopy has been completed in technical working area 41 of versailles project on advanced materials and standards. Twelve laboratories participated in the comparison project, led by NIM, China, to improve the equivalence of thickness measurement for two-dimensional flakes. The measurement methods, uncertainty evaluation and a comparison of the results and analysis are reported in this manuscript. The data and results of this project will be directly used to support the development of an ISO standard.


  • Open Access

    Metrological Protocols for Reaching Reliable and SI-Traceable Size Results for Multi-Modal and Complexly Shaped Reference Nanoparticles

    by Nicolas Feltin, Loïc Crouzier, Alexandra Delvallée, Francesco Pellegrino, Valter Maurino, Dorota Bartczak, Heidi Goenaga-Infante, Olivier Taché, Sylvie Marguet, Fabienne Testard, et al.

    The study described in this paper was conducted in the framework of the European nPSize project (EMPIR program) with the main objective of proposing new reference certified nanomaterials for the market in order to improve the reliability and traceability of nanoparticle size measurements. For this purpose, bimodal populations as well as complexly shaped nanoparticles (bipyramids, cubes, and rods) were synthesized. An inter-laboratory comparison was organized for comparing the size measurements of the selected nanoparticle samples performed with electron microscopy (TEM, SEM, and TSEM), scanning probe microscopy (AFM), or small-angle X-ray scattering (SAXS). The results demonstrate good consistency of the measured size by the different techniques in cases where special care was taken for sample preparation, instrument calibration, and the clear definition of the measurand. For each characterization method, the calibration process is described and a semi-quantitative table grouping the main error sources is proposed for estimating the uncertainties associated with the measurements. Regarding microscopy-based techniques applied to complexly shaped nanoparticles, data dispersion can be observed when the size measurements are affected by the orientation of the nanoparticles on the substrate. For the most complex materials, hybrid approaches combining several complementary techniques were tested, with the outcome being that the reliability of the size results was improved.


  • Open Access

    Correlative Analysis of the Dimensional Properties of Bipyramidal Titania Nanoparticles by Complementing Electron Microscopy with Other Methods

    by Loïc Crouzier, Nicolas Feltin, Alexandra Delvallée, Francesco Pellegrino, Valter Maurino, Grzegorz Cios, Tomasz Tokarski, Christoph Salzmann, Jérôme Deumer, Christian Gollwitzer, et al.

    In this paper, the accurate determination of the size and size distribution of bipyramidal anatase nanoparticles (NPs) after deposition as single particles on a silicon substrate by correlative Scanning Electron Microscopy (SEM) with Atomic Force Microscopy (AFM) analysis is described as a new measurement procedure for metrological purposes. The knowledge of the exact orientation of the NPs is a crucial step in extracting the real 3D dimensions of the particles. Two approaches are proposed to determine the geometrical orientation of individual nano-bipyramides: (i) AFM profiling along the long bipyramid axis and (ii) stage tilting followed by SEM imaging. Furthermore, a recently developed method, Transmission Kikuchi Diffraction (TKD), which needs preparation of the crystalline NPs on electron-transparent substrates such as TEM grids, has been tested with respect to its capability of identifying the geometrical orientation of the individual NPs. With the NPs prepared homogeneously on a TEM grid, the transmission mode in a SEM, i.e., STEM-in-SEM (or T-SEM), can be also applied to extract accurate projection dimensions of the nanoparticles from the same sample area as that analysed by SEM, TKD and possibly AFM. Finally, Small Angle X-ray Scattering (SAXS) can be used as an ensemble technique able to measure the NPs in liquid suspension and, with ab-initio knowledge of the NP shape from the descriptive imaging techniques, to provide traceable NP size distribution and particle concentration.