Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Carmen García-López has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Methodology for Calculating the Damaged Surface and Its Relationship with Power Loss in Photovoltaic Modules by Electroluminescence Inspection for Corrective Maintenance

    by Nieves Saborido-Barba, Carmen García-López, José Antonio Clavijo-Blanco, Rafael Jiménez-Castañeda, Germán Álvarez-Tey

    Photovoltaic panels are exposed to various external factors that can cause damage, with the formation of cracks in the photovoltaic cells being one of the most recurrent issues affecting their production capacity. Electroluminescence (EL) tests are employed to detect these cracks. In this study, a methodology developed according to the IEC TS 60904-13 standard is presented, allowing for the calculation of the percentage of type C cracks in a PV panel and subsequently estimating the associated power loss. To validate the methodology, it was applied to a polycrystalline silicon module subjected to incremental damage through multiple impacts on its rear surface. After each impact, electroluminescence images and I-V curves were obtained and used to verify power loss estimates. More accurate estimates were achieved by assessing cracks at the PV cell level rather than by substring or considering the entire module. In this context, cell-level analysis becomes indispensable, as the most damaged cell significantly influences the performance of the photovoltaic model. Subsequently, the developed methodology was applied to evaluate the conditions of four photovoltaic panels that had been in operation, exemplifying its application in maintenance tasks. The results assisted in decision making regarding whether to replace or continue using the panels.


  • Open Access

    Uncertainty Assessment in Temperature Uniformity Survey of Thermal Processing Equipment According to AMS2750 Aerospace Specification

    by Carmen García-López, Germán Álvarez-Tey

    Thermal processing equipment used in the aerospace industry must meet the requirements of the processes for which they are intended. The periodic tests performed by calibration laboratories, according to the AMS2750 specification, are intended to ensure compliance with these equipment requirements. While this specification does not explicitly state the need for uncertainty calculation, it does specify that pyrometry laboratories must have an ISO/IEC 17025 Quality System accredited by a recognized regional body which is a member of the International Laboratory Accreditation Cooperation (ILAC). Therefore, the calculation of uncertainties is necessary. This work presents a methodology for conducting temperature uniformity surveys and uncertainty assessment in these tests. This methodology has been applied to four different types of equipment to analyse, in each case, the contributions of uncertainties and to assess their potential for improvement. The objectives that laboratories should aim for include improving measurement accuracy and reducing uncertainty components in order to meet the criteria of both AMS2750 and ISO/IEC 17025.


  • Open Access

    Evaluation of the Uncertainty of Surface Temperature Measurements in Photovoltaic Modules in Outdoor Operation

    by Carmen García-López, Germán Álvarez-Tey

    Faults in photovoltaic modules in operation can lead to power losses. By determining the module surface temperature, hot spots that can potentially cause this power loss can be detected. Temperature measurement by radiation allows a complete, reliable, and fast qualitative determination of hot spots on PV modules in outdoor operation. However, to obtain quantitative values, it is necessary to consider multiple factors: emissivity, reflected radiation, wind speed, intensity, shading, etc. Temperature quantitative measurement evaluation by contact is more studied, although by this technique it is impossible to examine the temperature of the entire module to detect hot spots because it is a point measurement and due to shading caused by the measurement probe on the surface. In this work, a method of temperature measurement by radiation is described, evaluating the uncertainty components, and a comparison is made with temperature measurement by contact on the module rear side points where module heating has been detected, also evaluating the uncertainty components. This comparison of both methods and uncertainty determination allows establishing a methodology in quantitative temperature measurement by radiation in photovoltaic modules in outdoor operation.


  • Open Access

    Strategy Based on Two Stages for IR Thermographic Inspections of Photovoltaic Plants

    by Germán Álvarez-Tey, Carmen García-López

    Aerial infrared (IR) thermography has been implemented in recent years, proving to be a powerful and versatile technique for performing maintenance at photovoltaic (PV) plants. Its application speed and reliability using unmanned aerial vehicles (UAVs) or drones make it extremely interesting at large PV plants, due to the associated savings in time and costs. Ground-level thermographic inspection is slower and more costly to apply, although it does provide higher optical resolution, due to being conducted closer to the PV modules being inspected. Both techniques used in combination can improve the diagnosis. An IR thermography inspection strategy is proposed for PV plants based on two stages. The first stage of the inspection is aerial, enabling thermal faults to be detected and located quickly and reliably. The second stage of the inspection is done on the ground and applied only to the most relevant incidents revealed in the first stage. This inspection strategy was applied to a 100 kW PV plant, with an improved diagnosis verified via this procedure, as the ground-level inspection detects one-off thermal incidents from objects creating shade and from solar reflections. For PV modules with open circuits or open substrings, the use of one technique or another is immaterial.


  • Open Access

    Electrical and Thermal Behaviour of Crystalline Photovoltaic Solar Modules in Shading Conditions

    by Germán Álvarez-Tey, José Antonio Clavijo-Blanco, Álvaro Gil-García, Rafael Jiménez-Castañeda, Carmen García-López

    The shadow effect caused by nearby objects or the lack of cleaning significantly affects the performance of photovoltaics (PV) installations. This article analyses the bypass diode electrical behaviour and the thermal response of a PV crystalline module under shading or soiling conditions. PV cells of different substrings were covered progressively to simulate the effect of shading or soiling while a programmable electronic DC load was connected to a PV module to set an operating voltage. Three different tests were made to different PV crystalline technology. The paper characterizes in real conditions the I–V curve, bypass diode current, and front and back side PV cell temperature with contact sensor and infrared (IR) thermography, respectively. The results showed that the operation voltage established in the PV module defines the electrical bypass diode current and thermal response under normal operating conditions, shading or soiling. To show the bypass diode behaviour in such conditions, I–V curves were obtained, pointing out the value of the current that flows through bypass diodes in the whole voltage range.