Ruben Hemelings
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ruben Hemelings has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
Bart Elen
Flemish Institute for Technological Research (VITO), Mol, Belgium
8 shared publicationsIngeborg Stalmans
Research Group Ophthalmology, Department of Neurosciences, KU Leuven, Leuven, Belgium
8 shared publicationsMatthew B. Blaschko
ESAT-PSI, KU Leuven, Leuven, Belgium
6 shared publicationsPatrick De Boever
Hasselt University, Diepenbeek, Belgium
5 shared publicationsJoão Barbosa-Breda
Research Group Ophthalmology, Department of Neurosciences, KU Leuven, Leuven, Belgium
4 shared publications- Patrick De Boever
Centre for Environmental Sciences, Hasselt University, Agoralaan, 3590 Diepenbeek, Belgium
3 shared publications
Latest Publications
- 15 April 2026
- Published by BMJ in British Journal of Ophthalmology
Deep learning in population-based screening for glaucoma
Background/aims: Deep learning algorithms have shown promise for glaucoma detection using retinal imaging. The Northern Finland Birth Cohort Eye Study is a randomised prospective cohort designed to evaluate the efficacy and cost-effectiveness of glaucoma screening in a middle-aged population. This study assessed the performance and generalisability of G-RISK, a deep learning model for glaucoma screening from fundus images, in individuals aged 45–49 years with low glaucoma prevalence (1.1%). Methods: Four screening scenarios were evaluated: detection of (1) glaucoma eyes, (2) glaucoma patients, (3) glaucoma and glaucoma suspect eyes and (4) glaucoma and glaucoma suspect patients. Performance across four photographic modalities was assessed using the area under the receiver operating characteristic curve (AUC), the precision–recall AUC (PR-AUC), and sensitivity at 95% specificity. Results: G-RISK achieved its highest performance when screening for glaucoma eyes using colour fundus photographs, with an AUC of 0.83 (95% CI 0.75 to 0.90), PR-AUC of 0.16 (95% CI 0.05 to 0.28) and sensitivity at 95% specificity of 0.43 (95% CI 0.28 to 0.59). Furthermore, discrimination remained consistent across other modalities (AUC 0.75–0.78). Performance was higher for confirmed glaucoma than combined glaucoma and glaucoma suspect cases (AUC 0.83 vs 0.67). Conclusions: G-RISK achieved the best results on colour fundus images, while maintaining discrimination across other imaging modalities. Screening metrics were constrained by the relatively young age and low glaucoma prevalence of the cohort. The reduced performance observed when including glaucoma suspects may relate to variability and uncertainty in their clinical definition.
- 15 April 2026
- Published by BMJ in British Journal of Ophthalmology
Deep learning in population-based screening for glaucoma
Background/aims: Deep learning algorithms have shown promise for glaucoma detection using retinal imaging. The Northern Finland Birth Cohort Eye Study is a randomised prospective cohort designed to evaluate the efficacy and cost-effectiveness of glaucoma screening in a middle-aged population. This study assessed the performance and generalisability of G-RISK, a deep learning model for glaucoma screening from fundus images, in individuals aged 45–49 years with low glaucoma prevalence (1.1%). Methods: Four screening scenarios were evaluated: detection of (1) glaucoma eyes, (2) glaucoma patients, (3) glaucoma and glaucoma suspect eyes and (4) glaucoma and glaucoma suspect patients. Performance across four photographic modalities was assessed using the area under the receiver operating characteristic curve (AUC), the precision–recall AUC (PR-AUC), and sensitivity at 95% specificity. Results: G-RISK achieved its highest performance when screening for glaucoma eyes using colour fundus photographs, with an AUC of 0.83 (95% CI 0.75 to 0.90), PR-AUC of 0.16 (95% CI 0.05 to 0.28) and sensitivity at 95% specificity of 0.43 (95% CI 0.28 to 0.59). Furthermore, discrimination remained consistent across other modalities (AUC 0.75–0.78). Performance was higher for confirmed glaucoma than combined glaucoma and glaucoma suspect cases (AUC 0.83 vs 0.67). Conclusions: G-RISK achieved the best results on colour fundus images, while maintaining discrimination across other imaging modalities. Screening metrics were constrained by the relatively young age and low glaucoma prevalence of the cohort. The reduced performance observed when including glaucoma suspects may relate to variability and uncertainty in their clinical definition.
- 25 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (2) , 448-462
Addressing Glaucoma Structure-Function Relationship: A Multi-Task Learning Framework With Multi-Modal and Unpaired Data
Glaucoma, an irreversible neurodegenerative disorder, can lead to vision loss and blindness. Visual field (VF) tests are crucial for quantifying functional damage in glaucoma, but the tests are time-consuming and the results have high variations, influenced by subjective behaviors and psychological states of patients. Consequently, predicting VF test results using objective, non-invasive, reproducible optical coherence tomography (OCT) data coupled with deep learning modeling is promising in improving clinical care. However, existing methods only focus on predicting single VF indicators, such as threshold sensitivities or deviation maps, and have poor performance in severe glaucoma. Since different VF indicators are correlated, developing a joint prediction model is beneficial. Furthermore, the availability of more VF test data than corresponding OCTs in most datasets poses a challenge in utilizing unpaired VF test data. This study proposes a multi-modal, multi-task learning framework based on OCT data for VF prediction. We introduce a dynamic weighted loss function to improve prediction performance for eyes with severe glaucoma. Additionally, we construct a novel PairMatcher model for augmenting unpaired VF data. Extensive experiments demonstrate that our framework outperforms existing methods, showcasing its potential for VF prediction in glaucoma.
- 25 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (2) , 448-462
Addressing Glaucoma Structure-Function Relationship: A Multi-Task Learning Framework With Multi-Modal and Unpaired Data
Glaucoma, an irreversible neurodegenerative disorder, can lead to vision loss and blindness. Visual field (VF) tests are crucial for quantifying functional damage in glaucoma, but the tests are time-consuming and the results have high variations, influenced by subjective behaviors and psychological states of patients. Consequently, predicting VF test results using objective, non-invasive, reproducible optical coherence tomography (OCT) data coupled with deep learning modeling is promising in improving clinical care. However, existing methods only focus on predicting single VF indicators, such as threshold sensitivities or deviation maps, and have poor performance in severe glaucoma. Since different VF indicators are correlated, developing a joint prediction model is beneficial. Furthermore, the availability of more VF test data than corresponding OCTs in most datasets poses a challenge in utilizing unpaired VF test data. This study proposes a multi-modal, multi-task learning framework based on OCT data for VF prediction. We introduce a dynamic weighted loss function to improve prediction performance for eyes with severe glaucoma. Additionally, we construct a novel PairMatcher model for augmenting unpaired VF data. Extensive experiments demonstrate that our framework outperforms existing methods, showcasing its potential for VF prediction in glaucoma.
- Open Access
- 5 December 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-2
Author Correction: Deep learning on fundus images detects glaucoma beyond the optic disc
- 5 December 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-2
Open AccessAuthor Correction: Deep learning on fundus images detects glaucoma beyond the optic disc
- Open Access
- 27 September 2023
- Published by Wiley in Acta Ophthalmologica
- Vol. 102 (2) , 216-227
A prototype protocol for evaluating the real‐world data set using a structured electronic health record in glaucoma
PurposeAs the first step in monitoring and evaluating day-to-day glaucoma care, this study reports all real-world data recorded during the first full year after the implementation of a prototype for glaucoma-specific structured electronic healthcare record (EHR).MethodsIn 2019, 4618 patients visited Tays Medical Glaucoma Clinic at Tays Eye Centre, Tampere University Hospital, Finland, that serves a population of 0.53 M. Patient data were entered into a glaucoma-specific EHR by trained nurses to be checked by glaucoma specialists. Tays Eye Centre follows the Finnish Current Care Guideline for glaucoma in which glaucoma is defined using a '2 out of 3' rule, that is, & GE;2 findings evaluated as glaucomatous in optic nerve head (ONH), retinal nerve fibre layer (RNFL) and visual field (VF).ResultsThe clinical evaluations of ONH, RNFL and VF were recorded in 95%-100% of all eyes. ONH was evaluated as glaucomatous more often (44%) than RNFL (33%) and VF tests (30%). Progressive changes in any of the three tests were recorded in 35% of the '& GE;2/3 glaucoma group' compared to 2%-9% in the other groups. The mean IOP at visit was 15 mmHg. The mean target IOP was 17 mmHg, and it was recorded in 94% of eyes.ConclusionThe developed structured data presentation enables comparisons between different population-based real-world glaucoma data sets and glaucoma clinics. Compared to a data set from the UK, the proportion of glaucoma suspicion-related visits was smaller in Tays Eye Centre and test intervals were longer.
- 27 September 2023
- Published by Wiley in Acta Ophthalmologica
- Vol. 102 (2) , 216-227
Open AccessA prototype protocol for evaluating the real‐world data set using a structured electronic health record in glaucoma
PurposeAs the first step in monitoring and evaluating day-to-day glaucoma care, this study reports all real-world data recorded during the first full year after the implementation of a prototype for glaucoma-specific structured electronic healthcare record (EHR).MethodsIn 2019, 4618 patients visited Tays Medical Glaucoma Clinic at Tays Eye Centre, Tampere University Hospital, Finland, that serves a population of 0.53 M. Patient data were entered into a glaucoma-specific EHR by trained nurses to be checked by glaucoma specialists. Tays Eye Centre follows the Finnish Current Care Guideline for glaucoma in which glaucoma is defined using a '2 out of 3' rule, that is, & GE;2 findings evaluated as glaucomatous in optic nerve head (ONH), retinal nerve fibre layer (RNFL) and visual field (VF).ResultsThe clinical evaluations of ONH, RNFL and VF were recorded in 95%-100% of all eyes. ONH was evaluated as glaucomatous more often (44%) than RNFL (33%) and VF tests (30%). Progressive changes in any of the three tests were recorded in 35% of the '& GE;2/3 glaucoma group' compared to 2%-9% in the other groups. The mean IOP at visit was 15 mmHg. The mean target IOP was 17 mmHg, and it was recorded in 94% of eyes.ConclusionThe developed structured data presentation enables comparisons between different population-based real-world glaucoma data sets and glaucoma clinics. Compared to a data set from the UK, the proportion of glaucoma suspicion-related visits was smaller in Tays Eye Centre and test intervals were longer.
- Top Cited PapersOpen Access
- 13 June 2023
- Published by Springer Nature in npj Digital Medicine
- Vol. 6 (1) , 1-15
A generalizable deep learning regression model for automated glaucoma screening from fundus images
A plethora of classification models for the detection of glaucoma from fundus images have been proposed in recent years. Often trained with data from a single glaucoma clinic, they report impressive performance on internal test sets, but tend to struggle in generalizing to external sets. This performance drop can be attributed to data shifts in glaucoma prevalence, fundus camera, and the definition of glaucoma ground truth. In this study, we confirm that a previously described regression network for glaucoma referral (G-RISK) obtains excellent results in a variety of challenging settings. Thirteen different data sources of labeled fundus images were utilized. The data sources include two large population cohorts (Australian Blue Mountains Eye Study, BMES and German Gutenberg Health Study, GHS) and 11 publicly available datasets (AIROGS, ORIGA, REFUGE1, LAG, ODIR, REFUGE2, GAMMA, RIM-ONEr3, RIM-ONE DL, ACRIMA, PAPILA). To minimize data shifts in input data, a standardized image processing strategy was developed to obtain 30° disc-centered images from the original data. A total of 149,455 images were included for model testing. Area under the receiver operating characteristic curve (AUC) for BMES and GHS population cohorts were at 0.976 [95% CI: 0.967–0.986] and 0.984 [95% CI: 0.980–0.991] on participant level, respectively. At a fixed specificity of 95%, sensitivities were at 87.3% and 90.3%, respectively, surpassing the minimum criteria of 85% sensitivity recommended by Prevent Blindness America. AUC values on the eleven publicly available data sets ranged from 0.854 to 0.988. These results confirm the excellent generalizability of a glaucoma risk regression model trained with homogeneous data from a single tertiary referral center. Further validation using prospective cohort studies is warranted.
- 13 June 2023
- Published by Springer Nature in npj Digital Medicine
- Vol. 6 (1) , 1-15
Top Cited PapersOpen AccessA generalizable deep learning regression model for automated glaucoma screening from fundus images
A plethora of classification models for the detection of glaucoma from fundus images have been proposed in recent years. Often trained with data from a single glaucoma clinic, they report impressive performance on internal test sets, but tend to struggle in generalizing to external sets. This performance drop can be attributed to data shifts in glaucoma prevalence, fundus camera, and the definition of glaucoma ground truth. In this study, we confirm that a previously described regression network for glaucoma referral (G-RISK) obtains excellent results in a variety of challenging settings. Thirteen different data sources of labeled fundus images were utilized. The data sources include two large population cohorts (Australian Blue Mountains Eye Study, BMES and German Gutenberg Health Study, GHS) and 11 publicly available datasets (AIROGS, ORIGA, REFUGE1, LAG, ODIR, REFUGE2, GAMMA, RIM-ONEr3, RIM-ONE DL, ACRIMA, PAPILA). To minimize data shifts in input data, a standardized image processing strategy was developed to obtain 30° disc-centered images from the original data. A total of 149,455 images were included for model testing. Area under the receiver operating characteristic curve (AUC) for BMES and GHS population cohorts were at 0.976 [95% CI: 0.967–0.986] and 0.984 [95% CI: 0.980–0.991] on participant level, respectively. At a fixed specificity of 95%, sensitivities were at 87.3% and 90.3%, respectively, surpassing the minimum criteria of 85% sensitivity recommended by Prevent Blindness America. AUC values on the eleven publicly available data sets ranged from 0.854 to 0.988. These results confirm the excellent generalizability of a glaucoma risk regression model trained with homogeneous data from a single tertiary referral center. Further validation using prospective cohort studies is warranted.
- Open Access
- 23 August 2022
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 11 (8) , 22
Pointwise Visual Field Estimation From Optical Coherence Tomography in Glaucoma Using Deep Learning
Purpose: Standard automated perimetry is the gold standard to monitor visual field (VF) loss in glaucoma management, but it is prone to intrasubject variability. We trained and validated a customized deep learning (DL) regression model with Xception backbone that estimates pointwise and overall VF sensitivity from unsegmented optical coherence tomography (OCT) scans. Methods: DL regression models have been trained with four imaging modalities (circumpapillary OCT at 3.5 mm, 4.1 mm, and 4.7 mm diameter) and scanning laser ophthalmoscopy en face images to estimate mean deviation (MD) and 52 threshold values. This retrospective study used data from patients who underwent a complete glaucoma examination, including a reliable Humphrey Field Analyzer (HFA) 24-2 SITA Standard (SS) VF exam and a SPECTRALIS OCT. Results: For MD estimation, weighted prediction averaging of all four individuals yielded a mean absolute error (MAE) of 2.89 dB (2.50–3.30) on 186 test images, reducing the baseline by 54% (MAEdecr%). For 52 VF threshold values’ estimation, the weighted ensemble model resulted in an MAE of 4.82 dB (4.45–5.22), representing an MAEdecr% of 38% from baseline when predicting the pointwise mean value. DL managed to explain 75% and 58% of the variance (R2) in MD and pointwise sensitivity estimation, respectively. Conclusions: Deep learning can estimate global and pointwise VF sensitivities that fall almost entirely within the 90% test–retest confidence intervals of the 24-2 SS test. Translational Relevance: Fast and consistent VF prediction from unsegmented OCT scans could become a solution for visual function estimation in patients unable to perform reliable VF exams.
- 23 August 2022
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 11 (8) , 22
Open AccessPointwise Visual Field Estimation From Optical Coherence Tomography in Glaucoma Using Deep Learning
Purpose: Standard automated perimetry is the gold standard to monitor visual field (VF) loss in glaucoma management, but it is prone to intrasubject variability. We trained and validated a customized deep learning (DL) regression model with Xception backbone that estimates pointwise and overall VF sensitivity from unsegmented optical coherence tomography (OCT) scans. Methods: DL regression models have been trained with four imaging modalities (circumpapillary OCT at 3.5 mm, 4.1 mm, and 4.7 mm diameter) and scanning laser ophthalmoscopy en face images to estimate mean deviation (MD) and 52 threshold values. This retrospective study used data from patients who underwent a complete glaucoma examination, including a reliable Humphrey Field Analyzer (HFA) 24-2 SITA Standard (SS) VF exam and a SPECTRALIS OCT. Results: For MD estimation, weighted prediction averaging of all four individuals yielded a mean absolute error (MAE) of 2.89 dB (2.50–3.30) on 186 test images, reducing the baseline by 54% (MAEdecr%). For 52 VF threshold values’ estimation, the weighted ensemble model resulted in an MAE of 4.82 dB (4.45–5.22), representing an MAEdecr% of 38% from baseline when predicting the pointwise mean value. DL managed to explain 75% and 58% of the variance (R2) in MD and pointwise sensitivity estimation, respectively. Conclusions: Deep learning can estimate global and pointwise VF sensitivities that fall almost entirely within the 90% test–retest confidence intervals of the 24-2 SS test. Translational Relevance: Fast and consistent VF prediction from unsegmented OCT scans could become a solution for visual function estimation in patients unable to perform reliable VF exams.
- Open Access
- 13 October 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-12
Deep learning on fundus images detects glaucoma beyond the optic disc
Although unprecedented sensitivity and specificity values are reported, recent glaucoma detection deep learning models lack in decision transparency. Here, we propose a methodology that advances explainable deep learning in the field of glaucoma detection and vertical cup-disc ratio (VCDR), an important risk factor. We trained and evaluated deep learning models using fundus images that underwent a certain cropping policy. We defined the crop radius as a percentage of image size, centered on the optic nerve head (ONH), with an equidistant spaced range from 10–60% (ONH crop policy). The inverse of the cropping mask was also applied (periphery crop policy). Trained models using original images resulted in an area under the curve (AUC) of 0.94 [95% CI 0.92–0.96] for glaucoma detection, and a coefficient of determination (R2) equal to 77% [95% CI 0.77–0.79] for VCDR estimation. Models that were trained on images with absence of the ONH are still able to obtain significant performance (0.88 [95% CI 0.85–0.90] AUC for glaucoma detection and 37% [95% CI 0.35–0.40] R2 score for VCDR estimation in the most extreme setup of 60% ONH crop). Our findings provide the first irrefutable evidence that deep learning can detect glaucoma from fundus image regions outside the ONH.
- 13 October 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-12
Open AccessDeep learning on fundus images detects glaucoma beyond the optic disc
Although unprecedented sensitivity and specificity values are reported, recent glaucoma detection deep learning models lack in decision transparency. Here, we propose a methodology that advances explainable deep learning in the field of glaucoma detection and vertical cup-disc ratio (VCDR), an important risk factor. We trained and evaluated deep learning models using fundus images that underwent a certain cropping policy. We defined the crop radius as a percentage of image size, centered on the optic nerve head (ONH), with an equidistant spaced range from 10–60% (ONH crop policy). The inverse of the cropping mask was also applied (periphery crop policy). Trained models using original images resulted in an area under the curve (AUC) of 0.94 [95% CI 0.92–0.96] for glaucoma detection, and a coefficient of determination (R2) equal to 77% [95% CI 0.77–0.79] for VCDR estimation. Models that were trained on images with absence of the ONH are still able to obtain significant performance (0.88 [95% CI 0.85–0.90] AUC for glaucoma detection and 37% [95% CI 0.35–0.40] R2 score for VCDR estimation in the most extreme setup of 60% ONH crop). Our findings provide the first irrefutable evidence that deep learning can detect glaucoma from fundus image regions outside the ONH.
- Open Access
Deep learning on fundus images detects glaucoma beyond the optic disc
Although unprecedented sensitivity and specificity values are reported, recent glaucoma detection deep learning models lack in decision transparency. Here, we propose a methodology that advances explainable deep learning in the field of glaucoma detection and vertical cup-disc ratio (VCDR), an important risk factor. We trained and evaluated deep learning models using fundus images that underwent a certain cropping policy. We defined the crop radius as a percentage of image size, centered on the optic nerve head (ONH), with an equidistant spaced range from 10%-60% (ONH crop policy). The inverse of the cropping mask was also applied (periphery crop policy). Trained models using original images resulted in an area under the curve (AUC) of 0.94 [95% CI: 0.92-0.96] for glaucoma detection, and a coefficient of determination (R^2) equal to 77% [95% CI: 0.77-0.79] for VCDR estimation. Models that were trained on images with absence of the ONH are still able to obtain significant performance (0.88 [95% CI: 0.85-0.90] AUC for glaucoma detection and 37% [95% CI: 0.35-0.40] R^2 score for VCDR estimation in the most extreme setup of 60% ONH crop). Our findings provide the first irrefutable evidence that deep learning can detect glaucoma from fundus image regions outside the ONH.
Open AccessDeep learning on fundus images detects glaucoma beyond the optic disc
Although unprecedented sensitivity and specificity values are reported, recent glaucoma detection deep learning models lack in decision transparency. Here, we propose a methodology that advances explainable deep learning in the field of glaucoma detection and vertical cup-disc ratio (VCDR), an important risk factor. We trained and evaluated deep learning models using fundus images that underwent a certain cropping policy. We defined the crop radius as a percentage of image size, centered on the optic nerve head (ONH), with an equidistant spaced range from 10%-60% (ONH crop policy). The inverse of the cropping mask was also applied (periphery crop policy). Trained models using original images resulted in an area under the curve (AUC) of 0.94 [95% CI: 0.92-0.96] for glaucoma detection, and a coefficient of determination (R^2) equal to 77% [95% CI: 0.77-0.79] for VCDR estimation. Models that were trained on images with absence of the ONH are still able to obtain significant performance (0.88 [95% CI: 0.85-0.90] AUC for glaucoma detection and 37% [95% CI: 0.35-0.40] R^2 score for VCDR estimation in the most extreme setup of 60% ONH crop). Our findings provide the first irrefutable evidence that deep learning can detect glaucoma from fundus image regions outside the ONH.
- 1 February 2021
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 199, 105920
Pathological myopia classification with simultaneous lesion segmentation using deep learning
- 1 February 2021
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 199, 105920
Pathological myopia classification with simultaneous lesion segmentation using deep learning
- Open Access
Pathological myopia classification with simultaneous lesion segmentation using deep learning
This investigation reports on the results of convolutional neural networks developed for the recently introduced PathologicAL Myopia (PALM) dataset, which consists of 1200 fundus images. We propose a new Optic Nerve Head (ONH)-based prediction enhancement for the segmentation of atrophy and fovea. Models trained with 400 available training images achieved an AUC of 0.9867 for pathological myopia classification, and a Euclidean distance of 58.27 pixels on the fovea localization task, evaluated on a test set of 400 images. Dice and F1 metrics for semantic segmentation of lesions scored 0.9303 and 0.9869 on optic disc, 0.8001 and 0.9135 on retinal atrophy, and 0.8073 and 0.7059 on retinal detachment, respectively. Our work was acknowledged with an award in the context of the "PathologicAL Myopia detection from retinal images" challenge held during the IEEE International Symposium on Biomedical Imaging (April 2019). Considering that (pathological) myopia cases are often identified as false positives and negatives in classification systems for glaucoma, we envision that the current work could aid in future research to discriminate between glaucomatous and highly-myopic eyes, complemented by the localization and segmentation of landmarks such as fovea, optic disc and atrophy.
Open AccessPathological myopia classification with simultaneous lesion segmentation using deep learning
This investigation reports on the results of convolutional neural networks developed for the recently introduced PathologicAL Myopia (PALM) dataset, which consists of 1200 fundus images. We propose a new Optic Nerve Head (ONH)-based prediction enhancement for the segmentation of atrophy and fovea. Models trained with 400 available training images achieved an AUC of 0.9867 for pathological myopia classification, and a Euclidean distance of 58.27 pixels on the fovea localization task, evaluated on a test set of 400 images. Dice and F1 metrics for semantic segmentation of lesions scored 0.9303 and 0.9869 on optic disc, 0.8001 and 0.9135 on retinal atrophy, and 0.8073 and 0.7059 on retinal detachment, respectively. Our work was acknowledged with an award in the context of the "PathologicAL Myopia detection from retinal images" challenge held during the IEEE International Symposium on Biomedical Imaging (April 2019). Considering that (pathological) myopia cases are often identified as false positives and negatives in classification systems for glaucoma, we envision that the current work could aid in future research to discriminate between glaucomatous and highly-myopic eyes, complemented by the localization and segmentation of landmarks such as fovea, optic disc and atrophy.