Min Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Min Wang has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Guoxing Wang
Department of Micro/Nano Electronics, Shanghai Jiao Tong University, Shanghai 200240, China
3 shared publications - Cheng Chen
School of Integrated Circuits (School of Information Science and Electronic Engineering), Shanghai Jiao Tong University, Shanghai 200240, China
2 shared publications - Jianyu Zhang
School of Integrated Circuits (School of Information Science and Electronic Engineering), Shanghai Jiao Tong University, Shanghai 200240, China
2 shared publications - Jiangang Lu
National Engineering Lab for TFT-LCD Materials and Technologies, Department of Electronic Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
1 shared publication - Jiarong Chen
National Key Laboratory of Advanced Micro and Nano Manufacture Technology Shanghai Jiao Tong University Shanghai China
1 shared publication Jingyuan Gu
Department of Electronic Engineering Shanghai Jiao Tong University Shanghai China
1 shared publication
Latest Publications
- Open Access
Photoacoustic Noninvasive Blood Glucose Monitoring: A Review of Systems and Strategies for Robust Glucose Concentration Estimation, with Perspectives on Miniaturization and Wearability
Noninvasive blood glucose monitoring has long been a critical research focus in diabetes management. Among emerging technologies, photoacoustic sensing, combining the molecular specificity with deep penetration, has garnered significant attention. It offers rapid response and pain-free operation, making it a strong candidate for next-generation portable blood glucose monitoring devices. This review systematically traces the development and current state of photoacoustic glucose sensing, with a particular focus on the selection and optimization of core system components. It also summarizes common interference in glucose detection and outlines strategies for their mitigation, along with signal processing and signal-to-noise ratio enhancement techniques suitable for real-world applications. Addressing the growing demand for wearable continuous glucose monitors, this work analyzes the key challenges in system integration and outlines recent advances in enabling technologies. It proposes multi-technology integration approaches to bridge the gap between photoacoustic sensing and microsystem design, offering theoretical foundations and practical guidance for future research on wearable photoacoustic systems.
Open AccessPhotoacoustic Noninvasive Blood Glucose Monitoring: A Review of Systems and Strategies for Robust Glucose Concentration Estimation, with Perspectives on Miniaturization and Wearability
Noninvasive blood glucose monitoring has long been a critical research focus in diabetes management. Among emerging technologies, photoacoustic sensing, combining the molecular specificity with deep penetration, has garnered significant attention. It offers rapid response and pain-free operation, making it a strong candidate for next-generation portable blood glucose monitoring devices. This review systematically traces the development and current state of photoacoustic glucose sensing, with a particular focus on the selection and optimization of core system components. It also summarizes common interference in glucose detection and outlines strategies for their mitigation, along with signal processing and signal-to-noise ratio enhancement techniques suitable for real-world applications. Addressing the growing demand for wearable continuous glucose monitors, this work analyzes the key challenges in system integration and outlines recent advances in enabling technologies. It proposes multi-technology integration approaches to bridge the gap between photoacoustic sensing and microsystem design, offering theoretical foundations and practical guidance for future research on wearable photoacoustic systems.
- Open Access
Development of a Rotation-Robust PPG Sensor for a Smart Ring
Cardiovascular disease (CVD) remains the leading cause of global mortality, highlighting the need for continuous vital sign monitoring. Photoplethysmography (PPG) is well suited for wearable devices. Smart rings, benefiting from dense capillary distribution and minimal tissue interference, can capture high-quality PPG signals with comfort, making them a promising next-generation wearable. However, ring rotation relative to the finger alters the optical path, especially for multi-wavelength light, thus reducing accuracy. This paper proposes a rotation-robust PPG sensor for smart rings. Monte Carlo simulations analyze photon transmission under different LED–photodiode (PD) angles, showing that at ±60°, green, red, and infrared light achieve optimal penetration into the microcirculation layer. Considering non-ideal conditions, the green-light angle is adjusted to ±30°, and a symmetrical sensor design is adopted. A prototype smart ring is developed, capable of recording 4-channel PPG, 3-axis acceleration, and 4-channel temperature signals at 100, 25, and 0.2 Hz, respectively. The system achieves reliable PPG acquisition with only 0.59 mA average current consumption. In continuous testing, heart rate estimation reached mean absolute errors of 0.82, 0.79, and 0.78 bpm for green, red, and IR light. The results provide a reference for future smart ring development.
Open AccessDevelopment of a Rotation-Robust PPG Sensor for a Smart Ring
Cardiovascular disease (CVD) remains the leading cause of global mortality, highlighting the need for continuous vital sign monitoring. Photoplethysmography (PPG) is well suited for wearable devices. Smart rings, benefiting from dense capillary distribution and minimal tissue interference, can capture high-quality PPG signals with comfort, making them a promising next-generation wearable. However, ring rotation relative to the finger alters the optical path, especially for multi-wavelength light, thus reducing accuracy. This paper proposes a rotation-robust PPG sensor for smart rings. Monte Carlo simulations analyze photon transmission under different LED–photodiode (PD) angles, showing that at ±60°, green, red, and infrared light achieve optimal penetration into the microcirculation layer. Considering non-ideal conditions, the green-light angle is adjusted to ±30°, and a symmetrical sensor design is adopted. A prototype smart ring is developed, capable of recording 4-channel PPG, 3-axis acceleration, and 4-channel temperature signals at 100, 25, and 0.2 Hz, respectively. The system achieves reliable PPG acquisition with only 0.59 mA average current consumption. In continuous testing, heart rate estimation reached mean absolute errors of 0.82, 0.79, and 0.78 bpm for green, red, and IR light. The results provide a reference for future smart ring development.
- 1 September 2019
- Published by Wiley in SID Symposium Digest of Technical Papers
- Vol. 50 (S1) , 358-360
33.1: Invited Paper: Multi‐plane Display Based on Cholosteric Liquid Crystal Films
In this paper, we present a multi‐plane augmented reality display based on polarization multiplexing. With reflection selectivity of cholesteric liquid crystal (CLC) films, left‐handed and right‐handed circularly polarized images are imaged at different depths. Monocolor and color dual‐plane display experiments have been implemented and verified to provide correct depth cues.
- 1 September 2019
- Published by Wiley in SID Symposium Digest of Technical Papers
- Vol. 50 (S1) , 358-360
33.1: Invited Paper: Multi‐plane Display Based on Cholosteric Liquid Crystal Films
In this paper, we present a multi‐plane augmented reality display based on polarization multiplexing. With reflection selectivity of cholesteric liquid crystal (CLC) films, left‐handed and right‐handed circularly polarized images are imaged at different depths. Monocolor and color dual‐plane display experiments have been implemented and verified to provide correct depth cues.
- Open Access
Removal of Motion Artifacts in Photoplethysmograph Sensors during Intensive Exercise for Accurate Heart Rate Calculation Based on Frequency Estimation and Notch Filtering
With photoplethysmograph (PPG) sensors showing increasing potential in wearable health monitoring, the challenging problem of motion artifact (MA) removal during intensive exercise has become a popular research topic. In this study, a novel method that combines heart rate frequency (HRF) estimation and notch filtering is proposed. The proposed method applies a cascaded adaptive noise cancellation (ANC) based on the least mean squares (LMS)-Newton algorithm for preliminary motion artifacts reduction, and further adopts special heart rate frequency tracking and correction schemes for accurate HRF estimation. Finally, notch filters are employed to restore the PPG signal with estimated HRF based on its quasi-periodicity. On an open source data set that features intensive running exercise, the proposed method achieves a competitive mean average absolute error (AAE) result of 0.92 bpm for HR estimation. The practical experiments are carried out with the PPG evaluation platform developed by ourselves. Under three different intensive motion patterns, a 0.89 bpm average AAE result is achieved with the average correlation coefficient between recovered PPG signal and reference PPG signal reaching 0.86. The experimental results demonstrate the effectiveness of the proposed method for accurate HR estimation and robust MA removal in PPG during intensive exercise.
Open AccessRemoval of Motion Artifacts in Photoplethysmograph Sensors during Intensive Exercise for Accurate Heart Rate Calculation Based on Frequency Estimation and Notch Filtering
With photoplethysmograph (PPG) sensors showing increasing potential in wearable health monitoring, the challenging problem of motion artifact (MA) removal during intensive exercise has become a popular research topic. In this study, a novel method that combines heart rate frequency (HRF) estimation and notch filtering is proposed. The proposed method applies a cascaded adaptive noise cancellation (ANC) based on the least mean squares (LMS)-Newton algorithm for preliminary motion artifacts reduction, and further adopts special heart rate frequency tracking and correction schemes for accurate HRF estimation. Finally, notch filters are employed to restore the PPG signal with estimated HRF based on its quasi-periodicity. On an open source data set that features intensive running exercise, the proposed method achieves a competitive mean average absolute error (AAE) result of 0.92 bpm for HR estimation. The practical experiments are carried out with the PPG evaluation platform developed by ourselves. Under three different intensive motion patterns, a 0.89 bpm average AAE result is achieved with the average correlation coefficient between recovered PPG signal and reference PPG signal reaching 0.86. The experimental results demonstrate the effectiveness of the proposed method for accurate HR estimation and robust MA removal in PPG during intensive exercise.