Min Wang

Min Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Min Wang has a total of 19 co-authors. Here are the top co-authors by number of shared publications:

  • Guoxing Wang

    Department of Micro/Nano Electronics, Shanghai Jiao Tong University, Shanghai 200240, China

    3 shared publications
  • Cheng Chen

    School of Integrated Circuits (School of Information Science and Electronic Engineering), Shanghai Jiao Tong University, Shanghai 200240, China

    2 shared publications
  • Jianyu Zhang

    School of Integrated Circuits (School of Information Science and Electronic Engineering), Shanghai Jiao Tong University, Shanghai 200240, China

    2 shared publications
  • Jiangang Lu

    National Engineering Lab for TFT-LCD Materials and Technologies, Department of Electronic Engineering, Shanghai Jiao Tong University, Shanghai 200240, China

    1 shared publication
  • Jiarong Chen

    National Key Laboratory of Advanced Micro and Nano Manufacture Technology Shanghai Jiao Tong University Shanghai China

    1 shared publication
  • Jingyuan Gu

    Department of Electronic Engineering Shanghai Jiao Tong University Shanghai China

    1 shared publication

Latest Publications

  • Open Access

    Photoacoustic Noninvasive Blood Glucose Monitoring: A Review of Systems and Strategies for Robust Glucose Concentration Estimation, with Perspectives on Miniaturization and Wearability

    by Jianyu Zhang, Zhizhang Li, Min Wang, Luohan Lin, Guoxing Wang, Cheng Chen

    Noninvasive blood glucose monitoring has long been a critical research focus in diabetes management. Among emerging technologies, photoacoustic sensing, combining the molecular specificity with deep penetration, has garnered significant attention. It offers rapid response and pain-free operation, making it a strong candidate for next-generation portable blood glucose monitoring devices. This review systematically traces the development and current state of photoacoustic glucose sensing, with a particular focus on the selection and optimization of core system components. It also summarizes common interference in glucose detection and outlines strategies for their mitigation, along with signal processing and signal-to-noise ratio enhancement techniques suitable for real-world applications. Addressing the growing demand for wearable continuous glucose monitors, this work analyzes the key challenges in system integration and outlines recent advances in enabling technologies. It proposes multi-technology integration approaches to bridge the gap between photoacoustic sensing and microsystem design, offering theoretical foundations and practical guidance for future research on wearable photoacoustic systems.


  • Open Access

    Development of a Rotation-Robust PPG Sensor for a Smart Ring

    by Min Wang, Wenqi Shi, Jianyu Zhang, Jiarong Chen, Qingliang Lin, Cheng Chen, Guoxing Wang

    Cardiovascular disease (CVD) remains the leading cause of global mortality, highlighting the need for continuous vital sign monitoring. Photoplethysmography (PPG) is well suited for wearable devices. Smart rings, benefiting from dense capillary distribution and minimal tissue interference, can capture high-quality PPG signals with comfort, making them a promising next-generation wearable. However, ring rotation relative to the finger alters the optical path, especially for multi-wavelength light, thus reducing accuracy. This paper proposes a rotation-robust PPG sensor for smart rings. Monte Carlo simulations analyze photon transmission under different LED–photodiode (PD) angles, showing that at ±60°, green, red, and infrared light achieve optimal penetration into the microcirculation layer. Considering non-ideal conditions, the green-light angle is adjusted to ±30°, and a symmetrical sensor design is adopted. A prototype smart ring is developed, capable of recording 4-channel PPG, 3-axis acceleration, and 4-channel temperature signals at 100, 25, and 0.2 Hz, respectively. The system achieves reliable PPG acquisition with only 0.59 mA average current consumption. In continuous testing, heart rate estimation reached mean absolute errors of 0.82, 0.79, and 0.78 bpm for green, red, and IR light. The results provide a reference for future smart ring development.


  • 33.1: Invited Paper: Multi‐plane Display Based on Cholosteric Liquid Crystal Films

    by Quanming Chen, Zenghui Peng, Yan Li, Shuxin Liu, Pengcheng Zhou, Jingyuan Gu, Jiangang Lu, Lishuang Yao, Min Wang, Yikai Su

    In this paper, we present a multi‐plane augmented reality display based on polarization multiplexing. With reflection selectivity of cholesteric liquid crystal (CLC) films, left‐handed and right‐handed circularly polarized images are imaged at different depths. Monocolor and color dual‐plane display experiments have been implemented and verified to provide correct depth cues.

  • Open Access

    Removal of Motion Artifacts in Photoplethysmograph Sensors during Intensive Exercise for Accurate Heart Rate Calculation Based on Frequency Estimation and Notch Filtering

    by Min Wang, Zhe Li, Qirui Zhang, Guoxing Wang

    With photoplethysmograph (PPG) sensors showing increasing potential in wearable health monitoring, the challenging problem of motion artifact (MA) removal during intensive exercise has become a popular research topic. In this study, a novel method that combines heart rate frequency (HRF) estimation and notch filtering is proposed. The proposed method applies a cascaded adaptive noise cancellation (ANC) based on the least mean squares (LMS)-Newton algorithm for preliminary motion artifacts reduction, and further adopts special heart rate frequency tracking and correction schemes for accurate HRF estimation. Finally, notch filters are employed to restore the PPG signal with estimated HRF based on its quasi-periodicity. On an open source data set that features intensive running exercise, the proposed method achieves a competitive mean average absolute error (AAE) result of 0.92 bpm for HR estimation. The practical experiments are carried out with the PPG evaluation platform developed by ourselves. Under three different intensive motion patterns, a 0.89 bpm average AAE result is achieved with the average correlation coefficient between recovered PPG signal and reference PPG signal reaching 0.86. The experimental results demonstrate the effectiveness of the proposed method for accurate HR estimation and robust MA removal in PPG during intensive exercise.