Liisa Porra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Liisa Porra has a total of 184 co-authors. Here are the top co-authors by number of shared publications:
- Heikki Suhonen
Department of Physics, University of Helsinki, Helsinki, Finland
10 shared publications Pekka Suortti
Department of Physics University of Helsinki, Finland
10 shared publicationsSam Bayat
University of Grenoble Alpes & Inserm UA7 STROBE Laboratory, Grenoble, France
7 shared publicationsWalid Habre
Anesthesiological Investigations Unit, University Hospitals of Geneva, Geneva, Switzerland
6 shared publicationsAlberto Bravin
ID17 Biomedical Beamline, European Synchrotron Radiation Facility (ESRF), Grenoble, France
5 shared publicationsGergely Albu
Anesthesiological Investigations Unit, University Hospitals of Geneva, Geneva, Switzerland
5 shared publications
Latest Publications
- Open Access
- 28 September 2025
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 64, 1326-1333
Properties of paraffin wax as a bolus material in accelerator-based boron neutron capture therapy
Background and purpose: Boron neutron capture therapy (BNCT) is targeted radiation therapy enabling cellular-level cancer treatment. With epithermal neutrons, the dose maximum typically occurs ~2 cm deep in tissue, challenging superficial tumor control. As in external beam radiation therapy, surface dose can be increased using a bolus. However, in BNCT, tissue equivalency is complex and strongly dependent on elemental composition. This study examined a paraffin wax bolus’s effect on the epithermal neutron beam in accelerator-based BNCT (AB-BNCT) and evaluated agreement between treatment planning system (TPS) calculations and measurements. Materials and methods: Beam characterization used the neutron activation method with gold and manganese foils. Due to its high cross-section for thermal neutrons, manganese activation serves as a surrogate for boron dose estimation. Irradiations were conducted in a 3D water tank and in a head-shaped phantom with 5 and 10 mm boluses. Dose calculation utilized the newly commissioned RayStation TPS with a Monte Carlo-based engine built on the GEANT4 toolkit. Results: Calculated and measured results agree within 5% accuracy in significant dose region (>50% dose). Near the surface and at greater depths, agreement remains within 10%. The bolus shifts the activation depth curve toward the surface by 4–13 mm depending on its thickness. Manganese surface activation increases from 30% without a bolus to ~70% and ~ 90% with 5 and 10 mm boluses, respectively. Interpretation: Paraffin wax effectively moderates neutron energy, making it a suitable bolus material for AB-BNCT treatments requiring increased surface dose.
- 28 September 2025
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 64, 1326-1333
Open AccessProperties of paraffin wax as a bolus material in accelerator-based boron neutron capture therapy
Background and purpose: Boron neutron capture therapy (BNCT) is targeted radiation therapy enabling cellular-level cancer treatment. With epithermal neutrons, the dose maximum typically occurs ~2 cm deep in tissue, challenging superficial tumor control. As in external beam radiation therapy, surface dose can be increased using a bolus. However, in BNCT, tissue equivalency is complex and strongly dependent on elemental composition. This study examined a paraffin wax bolus’s effect on the epithermal neutron beam in accelerator-based BNCT (AB-BNCT) and evaluated agreement between treatment planning system (TPS) calculations and measurements. Materials and methods: Beam characterization used the neutron activation method with gold and manganese foils. Due to its high cross-section for thermal neutrons, manganese activation serves as a surrogate for boron dose estimation. Irradiations were conducted in a 3D water tank and in a head-shaped phantom with 5 and 10 mm boluses. Dose calculation utilized the newly commissioned RayStation TPS with a Monte Carlo-based engine built on the GEANT4 toolkit. Results: Calculated and measured results agree within 5% accuracy in significant dose region (>50% dose). Near the surface and at greater depths, agreement remains within 10%. The bolus shifts the activation depth curve toward the surface by 4–13 mm depending on its thickness. Manganese surface activation increases from 30% without a bolus to ~70% and ~ 90% with 5 and 10 mm boluses, respectively. Interpretation: Paraffin wax effectively moderates neutron energy, making it a suitable bolus material for AB-BNCT treatments requiring increased surface dose.
- Open Access
- 23 September 2025
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 64, 1307-1311
Predictive factors of oral mucositis in patients with locally recurrent inoperable head and neck cancer treated with boron neutron capture therapy
Background and purpose: The prognosis of recurrent head and neck (HN) cancer is poor. High response rates have been achieved with boron neutron capture therapy (BNCT) in the treatment of locally recurrent HN cancer. Radiation-induced oral mucositis (OM) is a common adverse effect of BNCT. We evaluated the factors associated with severe OM in patients treated with BNCT. Patient/material and methods: Ninety two patients with locally recurrent inoperable HN cancer were treated with nuclear reactor-based BNCT in 1–2 fractions. The association between grade 3 OM, patient clinical parameters and maximum weighted oral mucosa dose was evaluated. Mucosal dose was calculated using the skin nitrogen concentration of 4.2%. A sigmoidal normal tissue complication probability (NTCP) model was created by dividing patients into four equal sized groups based on increasing dose levels. Results: Grade 3 OM was observed in 42% of patients after the first BNCT treatment. The prevalence of OM increased with higher maximum oral mucosa doses. From the NTCP curve, we estimated the dose corresponding to a 50% probability (D50) for grade 3 OM to be 13.5 Gy(W). Older age was the only patient-related factor significantly associated with increased grade 3 OM risk. Interpretation: Higher maximum oral mucosa doses increased the risk of grade 3 OM. Older age was the only other factor related to severe OM.
- 23 September 2025
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 64, 1307-1311
Open AccessPredictive factors of oral mucositis in patients with locally recurrent inoperable head and neck cancer treated with boron neutron capture therapy
Background and purpose: The prognosis of recurrent head and neck (HN) cancer is poor. High response rates have been achieved with boron neutron capture therapy (BNCT) in the treatment of locally recurrent HN cancer. Radiation-induced oral mucositis (OM) is a common adverse effect of BNCT. We evaluated the factors associated with severe OM in patients treated with BNCT. Patient/material and methods: Ninety two patients with locally recurrent inoperable HN cancer were treated with nuclear reactor-based BNCT in 1–2 fractions. The association between grade 3 OM, patient clinical parameters and maximum weighted oral mucosa dose was evaluated. Mucosal dose was calculated using the skin nitrogen concentration of 4.2%. A sigmoidal normal tissue complication probability (NTCP) model was created by dividing patients into four equal sized groups based on increasing dose levels. Results: Grade 3 OM was observed in 42% of patients after the first BNCT treatment. The prevalence of OM increased with higher maximum oral mucosa doses. From the NTCP curve, we estimated the dose corresponding to a 50% probability (D50) for grade 3 OM to be 13.5 Gy(W). Older age was the only patient-related factor significantly associated with increased grade 3 OM risk. Interpretation: Higher maximum oral mucosa doses increased the risk of grade 3 OM. Older age was the only other factor related to severe OM.
- Open Access
- 4 July 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1066
Effects of ionization chamber orientation in photon and neutron beams
- 4 July 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1066
Open AccessEffects of ionization chamber orientation in photon and neutron beams
- 5 April 2023
- Published by SAGE Publications in Cancer Biotherapy and Radiopharmaceuticals
- Vol. 38 (3) , 184-191
From Nuclear Reactor-Based to Proton Accelerator-Based Therapy: The Finnish Boron Neutron Capture Therapy Experience
The authors review the results of 249 patients treated with boron neutron capture therapy (BNCT) at the Helsinki University Hospital, Helsinki, Finland, from May 1999 to January 2012 with neutrons obtained from a nuclear reactor source (FiR 1) and using l -boronophenylalanine-fructose ( l -BPA-F) as the boron delivery agent. They also describe a new hospital BNCT facility that hosts a proton accelerator-based neutron source for BNCT. Most of the patients treated with nuclear reactor-derived neutrons had either inoperable, locally recurrent head and neck cancer or malignant glioma. In general, l -BPA-F-mediated BNCT was relatively well tolerated with adverse events usually similar to those of conventional radiotherapy. Twenty-eight (96.6%) out of the evaluable 29 patients with head and neck cancer and treated within a clinical trial either responded to BNCT or had tumor growth stabilization for at least 5 months, suggesting efficacy of BNCT in the treatment of this patient population. The new accelerator-based BNCT facility houses a nuBeam neutron source that consists of an electrostatic Cockcroft–Walton-type proton accelerator and a lithium target that converts the proton beam to neutrons. The proton beam energy is 2.6 MeV operating with a current of 30 mA. Treatment planning is based on Monte Carlo simulation and the RayStation treatment planning system. Patient positioning is performed with a 6-axis robotic image-guided system, and in-room imaging is done with a rail-mounted computed tomography scanner. Under normal circumstances, the personnel can enter the treatment room almost immediately after shutting down the proton beam, which improves the unit capacity. ClinicalTrials.gov ID: NCT00114790.
- 5 April 2023
- Published by SAGE Publications in Cancer Biotherapy and Radiopharmaceuticals
- Vol. 38 (3) , 184-191
From Nuclear Reactor-Based to Proton Accelerator-Based Therapy: The Finnish Boron Neutron Capture Therapy Experience
The authors review the results of 249 patients treated with boron neutron capture therapy (BNCT) at the Helsinki University Hospital, Helsinki, Finland, from May 1999 to January 2012 with neutrons obtained from a nuclear reactor source (FiR 1) and using l -boronophenylalanine-fructose ( l -BPA-F) as the boron delivery agent. They also describe a new hospital BNCT facility that hosts a proton accelerator-based neutron source for BNCT. Most of the patients treated with nuclear reactor-derived neutrons had either inoperable, locally recurrent head and neck cancer or malignant glioma. In general, l -BPA-F-mediated BNCT was relatively well tolerated with adverse events usually similar to those of conventional radiotherapy. Twenty-eight (96.6%) out of the evaluable 29 patients with head and neck cancer and treated within a clinical trial either responded to BNCT or had tumor growth stabilization for at least 5 months, suggesting efficacy of BNCT in the treatment of this patient population. The new accelerator-based BNCT facility houses a nuBeam neutron source that consists of an electrostatic Cockcroft–Walton-type proton accelerator and a lithium target that converts the proton beam to neutrons. The proton beam energy is 2.6 MeV operating with a current of 30 mA. Treatment planning is based on Monte Carlo simulation and the RayStation treatment planning system. Patient positioning is performed with a 6-axis robotic image-guided system, and in-room imaging is done with a rail-mounted computed tomography scanner. Under normal circumstances, the personnel can enter the treatment room almost immediately after shutting down the proton beam, which improves the unit capacity. ClinicalTrials.gov ID: NCT00114790.
- 1 April 2023
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 134 (4) , 995-1003
Fractal dimension of pulmonary gas and blood distribution assessed by synchrotron K-edge subtraction imaging: effect of bronchoconstriction
Here, we used an energy-subtractive imaging technique to assess the fractal dimension (Df) of lung gas and blood distribution and the effect of acute bronchoconstriction. We found that Df of gas significantly decreases in bronchoconstriction. Conversely, Df of blood exhibits gravity-dependent changes only, and is not affected by acute bronchoconstriction. Our data show that the fractal dimension of lung gas detects the emergence of clustered rather than scattered loss of ventilatory units during bronchoconstriction.
- 1 April 2023
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 134 (4) , 995-1003
Fractal dimension of pulmonary gas and blood distribution assessed by synchrotron K-edge subtraction imaging: effect of bronchoconstriction
Here, we used an energy-subtractive imaging technique to assess the fractal dimension (Df) of lung gas and blood distribution and the effect of acute bronchoconstriction. We found that Df of gas significantly decreases in bronchoconstriction. Conversely, Df of blood exhibits gravity-dependent changes only, and is not affected by acute bronchoconstriction. Our data show that the fractal dimension of lung gas detects the emergence of clustered rather than scattered loss of ventilatory units during bronchoconstriction.
- 25 September 2021
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 61 (2) , 269-273
Accelerator-based boron neutron capture therapy facility at the Helsinki University Hospital
Boron neutron capture therapy (BNCT) is a unique type of radiation therapy that enables biological targeting of cancer at the cellular level. BNCT has been used to treat cancer with a two-step proc...
- 25 September 2021
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 61 (2) , 269-273
Accelerator-based boron neutron capture therapy facility at the Helsinki University Hospital
Boron neutron capture therapy (BNCT) is a unique type of radiation therapy that enables biological targeting of cancer at the cellular level. BNCT has been used to treat cancer with a two-step proc...
- 1 October 2019
- Published by SAGE Publications in Journal of Adolescent and Young Adult Oncology
- Vol. 8 (5) , 593-601
Radiation-Induced Meningiomas After Childhood Brain Tumor: A Magnetic Resonance Imaging Screening Study
Purpose: Childhood brain tumors (CBTs) and their treatment increase the risk of secondary neoplasms (SNs). We studied the incidence of secondary craniospinal tumors with magnetic resonance imaging (MRI) screening in a national cohort of survivors of CBT treated with radiotherapy, and we analyzed the Finnish Cancer Registry (FCR) data on SNs in survivors of CBT with radiotherapy registered as a part of the primary tumor treatment. Methods: A total of 73 survivors of CBT participated in the MRI study (mean follow-up of 19 ± 6.2 years). The incidence of SNs in a cohort of CBT patients (N = 569) was retrieved from the FCR (mean follow-up of 11 ± 12.9 years). Brain tumors were diagnosed at age ≤16 years between the years 1970 and 2008 in the clinical study and the years 1963 and 2010 in the FCR population. Results: Secondary brain tumors, meningiomas in all and schwannoma in one, were found in 6 of the 73 (8.2%) survivors with a mean of 23 ± 4.3 years after the diagnosis of the primary tumor. The cumulative incidence was 10.2% (95% confidence interval [CI] 3.9–25.1) in 25 years of follow-up. In the FCR data, the 25-year cumulative incidence of SNs was 2.4% (95% CI 1.3–4.1); only two brain tumors, no meningiomas, were registered. Conclusion: Survivors of CBT treated with radiotherapy have a high incidence of meningiomas, which are rarely registered in the FCR.
- 1 October 2019
- Published by SAGE Publications in Journal of Adolescent and Young Adult Oncology
- Vol. 8 (5) , 593-601
Radiation-Induced Meningiomas After Childhood Brain Tumor: A Magnetic Resonance Imaging Screening Study
Purpose: Childhood brain tumors (CBTs) and their treatment increase the risk of secondary neoplasms (SNs). We studied the incidence of secondary craniospinal tumors with magnetic resonance imaging (MRI) screening in a national cohort of survivors of CBT treated with radiotherapy, and we analyzed the Finnish Cancer Registry (FCR) data on SNs in survivors of CBT with radiotherapy registered as a part of the primary tumor treatment. Methods: A total of 73 survivors of CBT participated in the MRI study (mean follow-up of 19 ± 6.2 years). The incidence of SNs in a cohort of CBT patients (N = 569) was retrieved from the FCR (mean follow-up of 11 ± 12.9 years). Brain tumors were diagnosed at age ≤16 years between the years 1970 and 2008 in the clinical study and the years 1963 and 2010 in the FCR population. Results: Secondary brain tumors, meningiomas in all and schwannoma in one, were found in 6 of the 73 (8.2%) survivors with a mean of 23 ± 4.3 years after the diagnosis of the primary tumor. The cumulative incidence was 10.2% (95% confidence interval [CI] 3.9–25.1) in 25 years of follow-up. In the FCR data, the 25-year cumulative incidence of SNs was 2.4% (95% CI 1.3–4.1); only two brain tumors, no meningiomas, were registered. Conclusion: Survivors of CBT treated with radiotherapy have a high incidence of meningiomas, which are rarely registered in the FCR.
- 1 September 2019
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 47 (9) , e774-e781
Individual Airway Closure Characterized In Vivo by Phase-Contrast CT Imaging in Injured Rabbit Lung*
Objectives: Airway closure is involved in adverse effects of mechanical ventilation under both general anesthesia and in acute respiratory distress syndrome patients. However, direct evidence and characterization of individual airway closure is lacking. Here, we studied the same individual peripheral airways in intact lungs of anesthetized and mechanically ventilated rabbits, at baseline and following lung injury, using high-resolution synchrotron phase-contrast CT. Design: Laboratory animal investigation. Setting: European synchrotron radiation facility. Subjects: Six New-Zealand White rabbits. Interventions: The animals were anesthetized, paralyzed, and mechanically ventilated in pressure-controlled mode (tidal volume, 6 mL/kg; respiratory rate, 40; Fio 2, 0.6; inspiratory:expiratory, 1:2; and positive end-expiratory pressure, 3 cm H2O) at baseline. Imaging was performed with a 47.5 × 47.5 × 47.5 μm voxel size, at positive end-expiratory pressure 12, 9, 6, 3, and 0 cm H2O. The imaging sequence was repeated after lung injury induced by whole-lung lavage and injurious ventilation in four rabbits. Cross-sections of the same individual airways were measured. Measurements and Main Results: The airways were measured at baseline (n = 48; radius, 1.7 to 0.21 mm) and after injury (n = 32). Closure was observed at 0 cm H2O in three of 48 airways (6.3%; radius, 0.35 ± 0.08 mm at positive end-expiratory pressure 12) at baseline and five of 32 (15.6%; radius, 0.28 ± 0.09 mm) airways after injury. Cross-section was significantly reduced at 3 and 0 cm H2O, after injury, with a significant relation between the relative change in cross-section and airway radius at 12 cm H2O in injured, but not in normal lung (R = 0.60; p < 0.001). Conclusions: Airway collapsibility increases in the injured lung with a significant dependence on airway caliber. We identify “compliant collapse” as the main mechanism of airway closure in initially patent airways, which can occur at more than one site in individual airways.
- 1 September 2019
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 47 (9) , e774-e781
Individual Airway Closure Characterized In Vivo by Phase-Contrast CT Imaging in Injured Rabbit Lung*
Objectives: Airway closure is involved in adverse effects of mechanical ventilation under both general anesthesia and in acute respiratory distress syndrome patients. However, direct evidence and characterization of individual airway closure is lacking. Here, we studied the same individual peripheral airways in intact lungs of anesthetized and mechanically ventilated rabbits, at baseline and following lung injury, using high-resolution synchrotron phase-contrast CT. Design: Laboratory animal investigation. Setting: European synchrotron radiation facility. Subjects: Six New-Zealand White rabbits. Interventions: The animals were anesthetized, paralyzed, and mechanically ventilated in pressure-controlled mode (tidal volume, 6 mL/kg; respiratory rate, 40; Fio 2, 0.6; inspiratory:expiratory, 1:2; and positive end-expiratory pressure, 3 cm H2O) at baseline. Imaging was performed with a 47.5 × 47.5 × 47.5 μm voxel size, at positive end-expiratory pressure 12, 9, 6, 3, and 0 cm H2O. The imaging sequence was repeated after lung injury induced by whole-lung lavage and injurious ventilation in four rabbits. Cross-sections of the same individual airways were measured. Measurements and Main Results: The airways were measured at baseline (n = 48; radius, 1.7 to 0.21 mm) and after injury (n = 32). Closure was observed at 0 cm H2O in three of 48 airways (6.3%; radius, 0.35 ± 0.08 mm at positive end-expiratory pressure 12) at baseline and five of 32 (15.6%; radius, 0.28 ± 0.09 mm) airways after injury. Cross-section was significantly reduced at 3 and 0 cm H2O, after injury, with a significant relation between the relative change in cross-section and airway radius at 12 cm H2O in injured, but not in normal lung (R = 0.60; p < 0.001). Conclusions: Airway collapsibility increases in the injured lung with a significant dependence on airway caliber. We identify “compliant collapse” as the main mechanism of airway closure in initially patent airways, which can occur at more than one site in individual airways.
- Open Access
- 28 July 2019
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 8 (8) , 1117
The Effect of Positive End-Expiratory Pressure on Lung Micromechanics Assessed by Synchrotron Radiation Computed Tomography in an Animal Model of ARDS
Modern ventilatory strategies are based on the assumption that lung terminal airspaces act as isotropic balloons that progressively accommodate gas. Phase contrast synchrotron radiation computed tomography (PCSRCT) has recently challenged this concept, showing that in healthy lungs, deflation mechanisms are based on the sequential de-recruitment of airspaces. Using PCSRCT scans in an animal model of acute respiratory distress syndrome (ARDS), this study examined whether the numerosity (ASnum) and dimension (ASdim) of lung airspaces change during a deflation maneuver at decreasing levels of positive end-expiratory pressure (PEEP) at 12, 9, 6, 3, and 0 cmH2O. Deflation was associated with significant reduction of ASdim both in the whole lung section (passing from from 13.1 ± 2.0 at PEEP 12 to 7.6 ± 4.2 voxels at PEEP 0) and in single concentric regions of interest (ROIs). However, the regression between applied PEEP and ASnum was significant in the whole slice (ranging from 188 ± 52 at PEEP 12 to 146.4 ± 96.7 at PEEP 0) but not in the single ROIs. This mechanism of deflation in which reduction of ASdim is predominant, differs from the one observed in healthy conditions, suggesting that the peculiar alveolar micromechanics of ARDS might play a role in the deflation process.
- 28 July 2019
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 8 (8) , 1117
Open AccessThe Effect of Positive End-Expiratory Pressure on Lung Micromechanics Assessed by Synchrotron Radiation Computed Tomography in an Animal Model of ARDS
Modern ventilatory strategies are based on the assumption that lung terminal airspaces act as isotropic balloons that progressively accommodate gas. Phase contrast synchrotron radiation computed tomography (PCSRCT) has recently challenged this concept, showing that in healthy lungs, deflation mechanisms are based on the sequential de-recruitment of airspaces. Using PCSRCT scans in an animal model of acute respiratory distress syndrome (ARDS), this study examined whether the numerosity (ASnum) and dimension (ASdim) of lung airspaces change during a deflation maneuver at decreasing levels of positive end-expiratory pressure (PEEP) at 12, 9, 6, 3, and 0 cmH2O. Deflation was associated with significant reduction of ASdim both in the whole lung section (passing from from 13.1 ± 2.0 at PEEP 12 to 7.6 ± 4.2 voxels at PEEP 0) and in single concentric regions of interest (ROIs). However, the regression between applied PEEP and ASnum was significant in the whole slice (ranging from 188 ± 52 at PEEP 12 to 146.4 ± 96.7 at PEEP 0) but not in the single ROIs. This mechanism of deflation in which reduction of ASdim is predominant, differs from the one observed in healthy conditions, suggesting that the peculiar alveolar micromechanics of ARDS might play a role in the deflation process.
- Open Access
- 7 June 2019
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 10, 719
Regional Behavior of Airspaces During Positive Pressure Reduction Assessed by Synchrotron Radiation Computed Tomography
Introduction: The mechanisms of lung inflation and deflation are only partially known. Ventilatory strategies to support lung function rely upon the idea that lung alveoli are isotropic balloons that progressively inflate or deflate and that lung pressure/volume curves derive only by the interplay of critical opening pressures, critical closing pressures, lung history, and position of alveoli inside the lung. This notion has been recently challenged by subpleural microscopy, magnetic resonance, and computed tomography (CT). Phase-contrast synchrotron radiation CT (PC-SRCT) can yield in vivo images at resolutions higher than conventional CT. Objectives: We aimed to assess the numerosity (ASden) and the extension of the surface of airspaces (ASext) in healthy conditions at different volumes, during stepwise lung deflation, in concentric regions of the lung. Methods: The study was conducted in seven anesthetized New Zealand rabbits. They underwent PC-SRCT scans (resolution of 47.7 μm) of the lung at five decreasing positive end expiratory pressure (PEEP) levels of 12, 9, 6, 3, and 0 cmH2O during end-expiratory holds. Three concentric regions of interest (ROIs) of the lung were studied: subpleural, mantellar, and core. The images were enhanced by phase contrast algorithms. ASden and ASext were computed by using the Image Processing Toolbox for MatLab. Statistical tests were used to assess any significant difference determined by PEEP or ROI on ASden and ASext. Results: When reducing PEEP, in each ROI the ASden significantly decreased. Conversely, ASext variation was not significant except for the core ROI. In the latter, the angular coefficient of the regression line was significantly low. Conclusion: The main mechanism behind the decrease in lung volume at PEEP reduction is derecruitment. In our study involving lung regions laying on isogravitational planes and thus equally influenced by gravitational forces, airspace numerosity and extension of surface depend on the local mechanical properties of the lung.
- 7 June 2019
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 10, 719
Open AccessRegional Behavior of Airspaces During Positive Pressure Reduction Assessed by Synchrotron Radiation Computed Tomography
Introduction: The mechanisms of lung inflation and deflation are only partially known. Ventilatory strategies to support lung function rely upon the idea that lung alveoli are isotropic balloons that progressively inflate or deflate and that lung pressure/volume curves derive only by the interplay of critical opening pressures, critical closing pressures, lung history, and position of alveoli inside the lung. This notion has been recently challenged by subpleural microscopy, magnetic resonance, and computed tomography (CT). Phase-contrast synchrotron radiation CT (PC-SRCT) can yield in vivo images at resolutions higher than conventional CT. Objectives: We aimed to assess the numerosity (ASden) and the extension of the surface of airspaces (ASext) in healthy conditions at different volumes, during stepwise lung deflation, in concentric regions of the lung. Methods: The study was conducted in seven anesthetized New Zealand rabbits. They underwent PC-SRCT scans (resolution of 47.7 μm) of the lung at five decreasing positive end expiratory pressure (PEEP) levels of 12, 9, 6, 3, and 0 cmH2O during end-expiratory holds. Three concentric regions of interest (ROIs) of the lung were studied: subpleural, mantellar, and core. The images were enhanced by phase contrast algorithms. ASden and ASext were computed by using the Image Processing Toolbox for MatLab. Statistical tests were used to assess any significant difference determined by PEEP or ROI on ASden and ASext. Results: When reducing PEEP, in each ROI the ASden significantly decreased. Conversely, ASext variation was not significant except for the core ROI. In the latter, the angular coefficient of the regression line was significantly low. Conclusion: The main mechanism behind the decrease in lung volume at PEEP reduction is derecruitment. In our study involving lung regions laying on isogravitational planes and thus equally influenced by gravitational forces, airspace numerosity and extension of surface depend on the local mechanical properties of the lung.