Patrik Andreasson
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Patrik Andreasson has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Anders G. Andersson
Division of Fluid and Experimental Mechanics, Luleå University of Technology, 977 54 Luleå, Sweden
1 shared publication J. Gunnar I. Hellström
Division of Fluid and Experimental Mechanics, Luleå University of Technology, 97187 Luleå, Sweden
1 shared publication- Johan Gunnar I. Hellström
Division of Fluid and Experimental Mechanics, Department of Engineering Sciences and Mathematics, Luleå University of Technology, 971 87 Luleå, Sweden
1 shared publication - L. Robin Andersson
Division of Fluid and Experimental Mechanics, Luleå University of Technology, 977 54 Luleå, Sweden
1 shared publication - P. A. Mikael Hedberg
Division of Fluid and Experimental Mechanics, Luleå University of Technology, 977 54 Luleå, Sweden
1 shared publication T. Staffan Lundström
Division of Fluid and Experimental Mechanics, Luleå University of Technology, 97187 Luleå, Sweden
1 shared publication
Latest Publications
- Open Access
Scale Experiments of a Shallow Channels Impact on Spillway Flow Distribution and Discharge Capacity
This experimental work on discharge capacity investigates the flow distribution in a downscaled, multi-outlet experimental hydraulic rig. The water passing over each individual outlet is gathered and measured separately by collecting it into a large tank suspended on weight cells. This is repeated to ensure repeatability of the mass flow measurement method. To provide a large and robust set of data for CFD validation, six different inflows are tested, ranging from 60 l/s to 180 l/s. The findings show that for a larger inflow, and thus a higher water level, the discharge distribution over the spillway gets exacerbated by increasing the relative differences in the flow through each outlet. The differences in the measured water levels at different points in the channel leading up to the outlets also increase. ADV is used to measure velocities in the flow leading up to the channel for two of the six tested inflows. The ADV data shows persistent recirculation zones in different dimensions, as well as how the flow moving towards the outlets changes subtly as inflow is increased. Finally, comparisons are made to previous experiments on similar setups, indicating that a larger water column under the crest of a spillway reduces risk of uneven flow distribution for a spillway with multiple outlets. The data presented, along with dimensions of the model, can be used as a case study to validate how well different computational methods can predict flow distribution and spillway capacity.
Open AccessScale Experiments of a Shallow Channels Impact on Spillway Flow Distribution and Discharge Capacity
This experimental work on discharge capacity investigates the flow distribution in a downscaled, multi-outlet experimental hydraulic rig. The water passing over each individual outlet is gathered and measured separately by collecting it into a large tank suspended on weight cells. This is repeated to ensure repeatability of the mass flow measurement method. To provide a large and robust set of data for CFD validation, six different inflows are tested, ranging from 60 l/s to 180 l/s. The findings show that for a larger inflow, and thus a higher water level, the discharge distribution over the spillway gets exacerbated by increasing the relative differences in the flow through each outlet. The differences in the measured water levels at different points in the channel leading up to the outlets also increase. ADV is used to measure velocities in the flow leading up to the channel for two of the six tested inflows. The ADV data shows persistent recirculation zones in different dimensions, as well as how the flow moving towards the outlets changes subtly as inflow is increased. Finally, comparisons are made to previous experiments on similar setups, indicating that a larger water column under the crest of a spillway reduces risk of uneven flow distribution for a spillway with multiple outlets. The data presented, along with dimensions of the model, can be used as a case study to validate how well different computational methods can predict flow distribution and spillway capacity.
- Open Access
Numerical Investigation of a Hydropower Tunnel: Estimating Localised Head-Loss Using the Manning Equation
The fluid dynamics within a water tunnel is investigated numerically using a RANS approach with the k- turbulence model. The computational model is based on a laser scan of a hydropower tunnel located in Gävunda, Sweden. The tunnel has a typical height of 6.9 m and a width of 7.2 m. While the average cross-sectional shape of the tunnel is smooth the local deviations are significant, where some roughness elements may be in the size of 5 m implying a large variation of the hydraulic radius. The results indicate that the Manning equation can successfully be used to study the localised pressure variations by taking into account the varying hydraulic radius and cross-sectional area of the tunnel. This indicates a dominant effect of the tunnel roughness in connection with the flow, which has the potential to be used in the future evaluation of tunnel durability. ANSYS-CFX was used for the simulations along with ICEM-CFD for building the mesh.Open AccessNumerical Investigation of a Hydropower Tunnel: Estimating Localised Head-Loss Using the Manning Equation
The fluid dynamics within a water tunnel is investigated numerically using a RANS approach with the k- turbulence model. The computational model is based on a laser scan of a hydropower tunnel located in Gävunda, Sweden. The tunnel has a typical height of 6.9 m and a width of 7.2 m. While the average cross-sectional shape of the tunnel is smooth the local deviations are significant, where some roughness elements may be in the size of 5 m implying a large variation of the hydraulic radius. The results indicate that the Manning equation can successfully be used to study the localised pressure variations by taking into account the varying hydraulic radius and cross-sectional area of the tunnel. This indicates a dominant effect of the tunnel roughness in connection with the flow, which has the potential to be used in the future evaluation of tunnel durability. ANSYS-CFX was used for the simulations along with ICEM-CFD for building the mesh.