Yan Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yan Liu has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Peng Deng
College of Civil Engineering and Architecture, Shandong University of Science and Technology, Qingdao 266590, China
6 shared publications - Jian Guo
College of Civil Engineering and Architecture, Shandong University of Science and Technology, Qingdao 266590, China
2 shared publications - Jianxun Guo
Ocean Univ China, Coll Engn, Qingdao 266100, Peoples R China
2 shared publications Peng Deng
Professor, Dept. Shandong Provincial Key Laboratory of Civil Engineering Disaster Prevention and Mitigation, Shandong Univ. of Science and Technology, Qingdao 266590, China
2 shared publications- Boyi Yang
College of Civil Engineering and Architecture, Shandong University of Science and Technology, Qingdao, China
1 shared publication Feng Ren
School of Civil Engineering and Architecture, University of Jinan, Jinan 250022, China
1 shared publication
Latest Publications
- Open Access
- 10 December 2024
- Published by Springer Nature
- p. 3-11
Effect of Water-Binder Ratio, Alkali Mass Fraction and Lightweight Aggregate Size on Mechanical Properties of Alkali-Activated Concrete
Alkali-Activated Ceramsite Concrete (AACC), a novel green building material, is important for the reutilization of industrial waste. Although there has been considerable progress in research on AACC, further investigation is still needed on ceramsite size, early strength, etc. In this paper, 11 groups containing 198 standard cubic specimens were fabricated to investigate the effects of water-binder ratio, alkali mass fraction and ceramsite diameter on compressive strength and splitting tensile strength at different ages. And the slump constant of the mixtures was tested for different water-binder ratios and alkali mass fractions during fabrication. The results showed that the slump and strength increased with the increase of water-binder ratio. As the alkali mass fraction increased the slump decreased and then increased but the strength increased and then decreased. Therefore the proper value of alkali mass fraction was about 6%. When the diameter of ceramsite increased, the compressive strength first increased and then decreased. Thus the 5–15 mm diameter was the optimum. Splitting tensile strength always decreased with the increase of diameter of ceramsite.
- 10 December 2024
- Published by Springer Nature
- p. 3-11
Open AccessEffect of Water-Binder Ratio, Alkali Mass Fraction and Lightweight Aggregate Size on Mechanical Properties of Alkali-Activated Concrete
Alkali-Activated Ceramsite Concrete (AACC), a novel green building material, is important for the reutilization of industrial waste. Although there has been considerable progress in research on AACC, further investigation is still needed on ceramsite size, early strength, etc. In this paper, 11 groups containing 198 standard cubic specimens were fabricated to investigate the effects of water-binder ratio, alkali mass fraction and ceramsite diameter on compressive strength and splitting tensile strength at different ages. And the slump constant of the mixtures was tested for different water-binder ratios and alkali mass fractions during fabrication. The results showed that the slump and strength increased with the increase of water-binder ratio. As the alkali mass fraction increased the slump decreased and then increased but the strength increased and then decreased. Therefore the proper value of alkali mass fraction was about 6%. When the diameter of ceramsite increased, the compressive strength first increased and then decreased. Thus the 5–15 mm diameter was the optimum. Splitting tensile strength always decreased with the increase of diameter of ceramsite.
- Open Access
Structural Behaviour of FRP-Reinforced Tubular T-Joint Subjected to Combined In-Plane Bending and Axial Load
In this study, 90 finite-element models are used to explore the behaviour of fibre-reinforced polymer (FRP) reinforced joints under combined in-plane bending (IPB) and axial load (AX). The effects of joint geometry, FRP layer count, and AX levels of the chord or brace are considered. Three typical failure modes are observed: chord plastic failure, brace plastic failure, and brace buckling failure. Increasing the number of FRP layers can ensure that failure is chord-related failure in a ductility manner rather than the unexpectedly brace-related brittle failure. Depending on the stress distribution of fibres, FRP reinforcement can restrict the deformation of joints subjected to complex loading patterns. Moreover, added FRP layers efficiently reduce the effect of brace AX on the IPB resistance. Finally, a modified strength equation is established, including the influence of FRP reinforcement, chord AX, and brace AX.
Open AccessStructural Behaviour of FRP-Reinforced Tubular T-Joint Subjected to Combined In-Plane Bending and Axial Load
In this study, 90 finite-element models are used to explore the behaviour of fibre-reinforced polymer (FRP) reinforced joints under combined in-plane bending (IPB) and axial load (AX). The effects of joint geometry, FRP layer count, and AX levels of the chord or brace are considered. Three typical failure modes are observed: chord plastic failure, brace plastic failure, and brace buckling failure. Increasing the number of FRP layers can ensure that failure is chord-related failure in a ductility manner rather than the unexpectedly brace-related brittle failure. Depending on the stress distribution of fibres, FRP reinforcement can restrict the deformation of joints subjected to complex loading patterns. Moreover, added FRP layers efficiently reduce the effect of brace AX on the IPB resistance. Finally, a modified strength equation is established, including the influence of FRP reinforcement, chord AX, and brace AX.
- Open Access
- 29 December 2023
- Published by Hindawi Limited in Advances in Civil Engineering
- Vol. 2023, 1-16
Finite Element Analysis of Corrosion Tubular T-Joint Repaired with Grouted Clamp
A finite element (FE) analysis of corroded circular hollow section T-joints repaired using grouted clamps is presented in this study. To ensure an accurate simulation, experiments on a T-joint with uniform corrosion and an intact T-joint with grouted clamp are reproduced separately using an FE model. The experimental and FE modeling results correlate closely, displaying similar failure behaviors and loaddisplacement responses. Subsequently, a total of 56 FE T-joint models with varying degrees of corrosion on the chord, repaired by grouted clamp, were then analyzed numerically. The corrosion was artificially applied to the chords outer surface at depths of 10, 20, and 30 of the chords thickness. The models also account for variations in joint geometry, dictated by parameters β and γ, which range from 0.565 to 0.678 and from 21 to 28, respectively. Furthermore, grouted clamps properties were examined, including sleeve length, thickness, strength, as well as the thickness and strength of the grout, in relation to the complexity of the repair. The grouted clamp demonstrated significant repair capability, increasing the ultimate strength of the corroded joint by up to 2.23 times. Reinforcements that are both thicker and longer substantially enhance the joints ultimate strength. However, inappropriate repair construction results in an abrupt termination of the loaddisplacement curve and a brittle failure phenomenon outside reinforced chord region. Additional weight from the grouted clamp requires reasonable control, and sleeve overlapping ratio should be guaranteed to be greater than 0.7. The joint bearing capacity can be efficiently increased by thicker grouts and sleeves only in ductile failure cases. The confinement effect and mechanism of the grouted clamp in joint deformation were visually analyzed as stress distribution from FE analysis results. Finally, a prediction equation is proposed to estimate the static strength of the repaired joint through regression analysis.
- 29 December 2023
- Published by Hindawi Limited in Advances in Civil Engineering
- Vol. 2023, 1-16
Open AccessFinite Element Analysis of Corrosion Tubular T-Joint Repaired with Grouted Clamp
A finite element (FE) analysis of corroded circular hollow section T-joints repaired using grouted clamps is presented in this study. To ensure an accurate simulation, experiments on a T-joint with uniform corrosion and an intact T-joint with grouted clamp are reproduced separately using an FE model. The experimental and FE modeling results correlate closely, displaying similar failure behaviors and loaddisplacement responses. Subsequently, a total of 56 FE T-joint models with varying degrees of corrosion on the chord, repaired by grouted clamp, were then analyzed numerically. The corrosion was artificially applied to the chords outer surface at depths of 10, 20, and 30 of the chords thickness. The models also account for variations in joint geometry, dictated by parameters β and γ, which range from 0.565 to 0.678 and from 21 to 28, respectively. Furthermore, grouted clamps properties were examined, including sleeve length, thickness, strength, as well as the thickness and strength of the grout, in relation to the complexity of the repair. The grouted clamp demonstrated significant repair capability, increasing the ultimate strength of the corroded joint by up to 2.23 times. Reinforcements that are both thicker and longer substantially enhance the joints ultimate strength. However, inappropriate repair construction results in an abrupt termination of the loaddisplacement curve and a brittle failure phenomenon outside reinforced chord region. Additional weight from the grouted clamp requires reasonable control, and sleeve overlapping ratio should be guaranteed to be greater than 0.7. The joint bearing capacity can be efficiently increased by thicker grouts and sleeves only in ductile failure cases. The confinement effect and mechanism of the grouted clamp in joint deformation were visually analyzed as stress distribution from FE analysis results. Finally, a prediction equation is proposed to estimate the static strength of the repaired joint through regression analysis.
- Open Access
Bond Performance of Anti-Corrosion Bar Embedded in Ceramsite Concrete in Freeze–Thaw Cycles and Corrosive Environments
At present, basalt fiber-reinforced polymer (BFRP) bars and epoxy-coated steel reinforcing bars (ECRs) are very promising in ocean engineering. In this study, the bond strength degradation characteristics of BFRP bars, ECR, and ordinary steel bars (OSBs) embedded in ceramsite concrete (CC) were compared in a single-corrosive environment (acid, salt, and alkaline salt, respectively) coupled with freeze–thaw (FT) cycles (0, 15, or 30); a total of 111 specimens were designed. In the three corrosive environments, the BFRP-bar-CC specimens and OSB-CC specimens all failed to pull out, while the ECR-CC specimens showed splitting failure. When corrosive and FT cycles acted together, the failure modes of BFRP-bar-CC specimens and ECR-CC specimens did not change. However, when the FT cycles increased from 15 to 30, the type of failure for the OSB-CC specimens changed from pullout failure to splitting failure. In addition, the bonding strength of the three kinds of bars decayed most rapidly in an acid environment. When 30 FT cycles were applied, the bond strength of ECR-CC specimens and OSB-CC specimens decreased most rapidly in the acid environment, by 9.12% and 18.62%, respectively. However, the bond strength of BFRP-bar-CC decreased most rapidly, by 17.2%, in an alkaline salt environment.
Open AccessBond Performance of Anti-Corrosion Bar Embedded in Ceramsite Concrete in Freeze–Thaw Cycles and Corrosive Environments
At present, basalt fiber-reinforced polymer (BFRP) bars and epoxy-coated steel reinforcing bars (ECRs) are very promising in ocean engineering. In this study, the bond strength degradation characteristics of BFRP bars, ECR, and ordinary steel bars (OSBs) embedded in ceramsite concrete (CC) were compared in a single-corrosive environment (acid, salt, and alkaline salt, respectively) coupled with freeze–thaw (FT) cycles (0, 15, or 30); a total of 111 specimens were designed. In the three corrosive environments, the BFRP-bar-CC specimens and OSB-CC specimens all failed to pull out, while the ECR-CC specimens showed splitting failure. When corrosive and FT cycles acted together, the failure modes of BFRP-bar-CC specimens and ECR-CC specimens did not change. However, when the FT cycles increased from 15 to 30, the type of failure for the OSB-CC specimens changed from pullout failure to splitting failure. In addition, the bonding strength of the three kinds of bars decayed most rapidly in an acid environment. When 30 FT cycles were applied, the bond strength of ECR-CC specimens and OSB-CC specimens decreased most rapidly in the acid environment, by 9.12% and 18.62%, respectively. However, the bond strength of BFRP-bar-CC decreased most rapidly, by 17.2%, in an alkaline salt environment.
- 1 July 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Materials in Civil Engineering
- Vol. 34 (7) , 04022125
Effect of Dry-Wet Cycles on BFRP Bars and Modified Ceramsite Concrete in Marine Environments
This study investigates the bonding behavior of modified ceramsite concrete (MLC) and basalt fiber-reinforced polymer (BFRP) bars exposed to dry-wet (D-W) cycles of simulated seawater using pull-out tests. Two types of concrete strengths—MLC25 and MLC35—were examined under different environmental exposure periods (0, 10, 30, and 50 cycles) using a total of 54 specimens. Compared with the specimens that were only immersed in artificial seawater (ASW, without D-W cycles), the D-W cycles had no significant effect on the failure mode, which remained as pull-out and splitting failures. However, the ultimate bond strength and slippage varied significantly, and the ultimate bond strength decayed between 5% and 35%, while the slippage increased from approximately 4% to 60%. The bond strength of LC35 decreased by 33.65%, and the slippage increased significantly (by 55%) after 50 D-W cycles (using one-time concentrated ASW). Moreover, the mechanical properties under this unconditional environment showed that the splitting tensile strength decreased by 3.67% and the compressive strength decreased by 5.47%.
- 1 July 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Materials in Civil Engineering
- Vol. 34 (7) , 04022125
Effect of Dry-Wet Cycles on BFRP Bars and Modified Ceramsite Concrete in Marine Environments
This study investigates the bonding behavior of modified ceramsite concrete (MLC) and basalt fiber-reinforced polymer (BFRP) bars exposed to dry-wet (D-W) cycles of simulated seawater using pull-out tests. Two types of concrete strengths—MLC25 and MLC35—were examined under different environmental exposure periods (0, 10, 30, and 50 cycles) using a total of 54 specimens. Compared with the specimens that were only immersed in artificial seawater (ASW, without D-W cycles), the D-W cycles had no significant effect on the failure mode, which remained as pull-out and splitting failures. However, the ultimate bond strength and slippage varied significantly, and the ultimate bond strength decayed between 5% and 35%, while the slippage increased from approximately 4% to 60%. The bond strength of LC35 decreased by 33.65%, and the slippage increased significantly (by 55%) after 50 D-W cycles (using one-time concentrated ASW). Moreover, the mechanical properties under this unconditional environment showed that the splitting tensile strength decreased by 3.67% and the compressive strength decreased by 5.47%.
- 10 June 2021
- Published by Wiley in Structural Concrete
- Vol. 22 (5) , 2829-2848
Bond durability of basalt‐fiber‐reinforced‐polymer bars embedded in lightweight aggregate concrete subjected to freeze–thaw cycles
In recent years, basalt‐fiber‐reinforced‐polymer (BFRP) bars have become popular to replace steels. However, little is known about the performance of BFRP bars inserted in lightweight aggregate concrete (LWAC), especially the bonding performance under freeze–thaw (FT) cycles. In this study, a bond strength test was conducted for BFRP bars embedded in LWAC after FT cycles. BFRP bars, epoxy‐coated bars, and steels were tested for comparison purposes. The test parameters are the bar type, compressive strength of the LWAC, and FT cycles; 108 specimens were subjected to 0, 15, 30, and 50 FT cycles. Moreover, the bond strength models of the three types of bars were fitted to LWAC. The test results prove that the number of FT cycles significantly affects the bonding performance of the bar embedded in LWAC. The results also show that the bond strength prediction of the fitting model considering the FT cycle effect is consistent with the experimental results.
- 10 June 2021
- Published by Wiley in Structural Concrete
- Vol. 22 (5) , 2829-2848
Bond durability of basalt‐fiber‐reinforced‐polymer bars embedded in lightweight aggregate concrete subjected to freeze–thaw cycles
In recent years, basalt‐fiber‐reinforced‐polymer (BFRP) bars have become popular to replace steels. However, little is known about the performance of BFRP bars inserted in lightweight aggregate concrete (LWAC), especially the bonding performance under freeze–thaw (FT) cycles. In this study, a bond strength test was conducted for BFRP bars embedded in LWAC after FT cycles. BFRP bars, epoxy‐coated bars, and steels were tested for comparison purposes. The test parameters are the bar type, compressive strength of the LWAC, and FT cycles; 108 specimens were subjected to 0, 15, 30, and 50 FT cycles. Moreover, the bond strength models of the three types of bars were fitted to LWAC. The test results prove that the number of FT cycles significantly affects the bonding performance of the bar embedded in LWAC. The results also show that the bond strength prediction of the fitting model considering the FT cycle effect is consistent with the experimental results.
- 2 January 2021
- Published by Springer Nature in International Journal of Steel Structures
- Vol. 21 (1) , 299-314
Damaged Tubular T-joints Retrofitted with Carbon Fiber Reinforced Polymer Subjected to Monotonic and Cyclic Loadings
- 2 January 2021
- Published by Springer Nature in International Journal of Steel Structures
- Vol. 21 (1) , 299-314
Damaged Tubular T-joints Retrofitted with Carbon Fiber Reinforced Polymer Subjected to Monotonic and Cyclic Loadings
- Open Access
- 1 September 2019
- Published by Elsevier in KSCE Journal of Civil Engineering
- Vol. 23 (9) , 4085-4101
Compressive Behavior of Damaged Tubular T-joints Retrofitted with Collar Plate
- 1 September 2019
- Published by Elsevier in KSCE Journal of Civil Engineering
- Vol. 23 (9) , 4085-4101
Open AccessCompressive Behavior of Damaged Tubular T-joints Retrofitted with Collar Plate
- Open Access
- 28 November 2017
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 94 (1) , 012203
Study on effective anchorage length of anchor cable based on Gauss's function
- 28 November 2017
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 94 (1) , 012203
Open AccessStudy on effective anchorage length of anchor cable based on Gauss's function