Grzegorz Nawalany
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Grzegorz Nawalany has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Paweł Sokołowski
Department of Rural Building, Faculty of Environmental Engineering, University of Agriculture in Krakow, al. Mickiewicza 24/28, 30-059 Krakow, Poland
16 shared publications - Małgorzata Michalik
Department of Rural Building, Faculty of Environmental Engineering, University of Agriculture in Krakow, al. Mickiewicza 24/28, 30-059 Krakow, Poland
6 shared publications - Atilgan Atilgan
Department of Biosystems Engineering, Faculty of Engineering, Alanya Alaaddin Keykubat University, 07425 Alanya, Türkiye
3 shared publications - Miroslav Žitňák
Faculty of Engineering, Institute of Agricultural Engineering, Transport and Bioenergetics, Slovak University of Agriculture in Nitra, Trieda Andreja Hlinku 2, 94976 Nitra, Slovakia
3 shared publications - Tomasz Jakubowski
Department of Machine Operation, Ergonomics and Production Processes, Faculty of Production and Power Engineering, University of Agriculture in Krakow, 30-059 Krakow, Poland
3 shared publications - Ernest Popardowski
Department of Machinery Exploitation, Ergonomics and Production Processes, University of Agriculture in Krakow, Balicka 116B, 30-149 Krakow, Poland
2 shared publications
Latest Publications
- Open Access
- 22 July 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (14) , 7468
Long-Term Empirical Study of Broiler House Microclimate Under Different Heating Systems: Implications for Sustainable Poultry Production
One of the most important factors affecting broiler production efficiency is providing appropriate indoor microclimatic conditions, which are significantly influenced by the heating system used. This study presents the results of long-term experimental investigations conducted in two buildings equipped with different heating systems. One of the buildings was equipped with a wall heating system supported by air heaters, while the other was equipped with an underfloor heating system During the winter production cycle, the indoor air temperature in the initial period ranged from 27.2 to 33.2 °C with the underfloor heating system and from 31.9 to 40.0 °C with the conventional radiator-based system. Even greater differences were observed in floor surface temperature, which ranged from 28.0 to 31.4 °C and from 11.0 to 22.0 °C, respectively. In the building with the underfloor heating system, the relative air humidity fluctuated from 43.1% to 66.8%, while in the building without an underfloor heating system, it ranged from 20.3% to 58.6%. During the first week of the winter production cycle, the use of underfloor heating reduced broiler mortality by 77.3%. These findings provide a basis for further research on heat and moisture transfer processes and can support the development and modernization of energy-efficient heating systems in livestock buildings. The results contribute to current efforts toward the sustainable development of poultry production by improving environmental control and enhancing energy efficiency.
- 22 July 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (14) , 7468
Open AccessLong-Term Empirical Study of Broiler House Microclimate Under Different Heating Systems: Implications for Sustainable Poultry Production
One of the most important factors affecting broiler production efficiency is providing appropriate indoor microclimatic conditions, which are significantly influenced by the heating system used. This study presents the results of long-term experimental investigations conducted in two buildings equipped with different heating systems. One of the buildings was equipped with a wall heating system supported by air heaters, while the other was equipped with an underfloor heating system During the winter production cycle, the indoor air temperature in the initial period ranged from 27.2 to 33.2 °C with the underfloor heating system and from 31.9 to 40.0 °C with the conventional radiator-based system. Even greater differences were observed in floor surface temperature, which ranged from 28.0 to 31.4 °C and from 11.0 to 22.0 °C, respectively. In the building with the underfloor heating system, the relative air humidity fluctuated from 43.1% to 66.8%, while in the building without an underfloor heating system, it ranged from 20.3% to 58.6%. During the first week of the winter production cycle, the use of underfloor heating reduced broiler mortality by 77.3%. These findings provide a basis for further research on heat and moisture transfer processes and can support the development and modernization of energy-efficient heating systems in livestock buildings. The results contribute to current efforts toward the sustainable development of poultry production by improving environmental control and enhancing energy efficiency.
- Open Access
Analysis of Useful Energy Demand for Heating Purposes in a Building with a Self-Supporting Polystyrene Structure in a Temperate Climate
This article presents an analysis of the useful energy demand for heating purposes in a single-family, single-storey building with a self-supporting polystyrene structure, which is a relatively niche solution, in relation to a traditional masonry structure with similar partition thickness. The structures considered met the requirements for passive buildings. The analysis was performed on three locations in Europe with a temperate climate, i.e., Kołobrzeg in Poland, Vienna in Austria, and Essen in Germany. The research showed significant savings in the energy demand of the polystyrene structure compared to the masonry structure for each location, ranging from 38% to 52%. Similarly, the heating period was 21% to 38% shorter in individual locations. This shows that polystyrene construction allows for a significant reduction in building energy demand, leading to lower operating costs.
Open AccessAnalysis of Useful Energy Demand for Heating Purposes in a Building with a Self-Supporting Polystyrene Structure in a Temperate Climate
This article presents an analysis of the useful energy demand for heating purposes in a single-family, single-storey building with a self-supporting polystyrene structure, which is a relatively niche solution, in relation to a traditional masonry structure with similar partition thickness. The structures considered met the requirements for passive buildings. The analysis was performed on three locations in Europe with a temperate climate, i.e., Kołobrzeg in Poland, Vienna in Austria, and Essen in Germany. The research showed significant savings in the energy demand of the polystyrene structure compared to the masonry structure for each location, ranging from 38% to 52%. Similarly, the heating period was 21% to 38% shorter in individual locations. This shows that polystyrene construction allows for a significant reduction in building energy demand, leading to lower operating costs.
- Open Access
- 26 March 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (7) , 2941
The Threat of Moisture in the Partitions of Unheated and Heated Wooden Historic Churches in Poland
This paper presents experimental studies of the formation of thermal and humidity conditions in two wooden historic churches in southern Poland. The environmental and cultural changes taking shape are creating the need to modernize existing buildings to sustainable standards. The modernization of historic religious buildings is complicated by restrictions on the intrusion of vertical partitions, which are often covered with valuable wall paintings. The paper focuses on the important aspect of preserving historically valuable buildings in good condition and assessing the threat posed by vapor condensation on the surface of the partitions. The studied buildings differ in terms of their uses and heating systems. Building A is unheated, while building B is equipped with a heating system. The scope of the study includes continuous measurements of the temperature and relative humidity of the indoor air inside and outside the studied churches. The work presents a detailed analysis and comparison of the formation of thermal and humidity conditions inside the churches. A computational model of the buildings was created, and then a computational simulation of the risk of water vapor condensation on the surface of the external walls was carried out. The analysis presents the influence of the external climate on the formation of the thermo-humidity conditions inside the buildings, especially in the unheated church. Also shown is the effect of the temporary heating of the church on ensuring the optimal heat and moisture conditions for historic wooden buildings. The analysis shows that turning on the heating only during the use of the church slightly improves the thermal and humidity conditions compared to the unheated church. Additionally, the analysis shows that the occasional use of the unheated church contributes to significant cooling of the church (even to −8.4 °C in the winter half year). Another conclusion that the computational analysis reveals is that water vapor condensation on the surface of the external walls is impossible. However, the difference between the air temperature in the church and the dew point temperature, specifically in the unheated church, is 1.6 °C. Therefore, at lower outside air temperatures, there may be a risk of water vapor condensation.
- 26 March 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (7) , 2941
Open AccessThe Threat of Moisture in the Partitions of Unheated and Heated Wooden Historic Churches in Poland
This paper presents experimental studies of the formation of thermal and humidity conditions in two wooden historic churches in southern Poland. The environmental and cultural changes taking shape are creating the need to modernize existing buildings to sustainable standards. The modernization of historic religious buildings is complicated by restrictions on the intrusion of vertical partitions, which are often covered with valuable wall paintings. The paper focuses on the important aspect of preserving historically valuable buildings in good condition and assessing the threat posed by vapor condensation on the surface of the partitions. The studied buildings differ in terms of their uses and heating systems. Building A is unheated, while building B is equipped with a heating system. The scope of the study includes continuous measurements of the temperature and relative humidity of the indoor air inside and outside the studied churches. The work presents a detailed analysis and comparison of the formation of thermal and humidity conditions inside the churches. A computational model of the buildings was created, and then a computational simulation of the risk of water vapor condensation on the surface of the external walls was carried out. The analysis presents the influence of the external climate on the formation of the thermo-humidity conditions inside the buildings, especially in the unheated church. Also shown is the effect of the temporary heating of the church on ensuring the optimal heat and moisture conditions for historic wooden buildings. The analysis shows that turning on the heating only during the use of the church slightly improves the thermal and humidity conditions compared to the unheated church. Additionally, the analysis shows that the occasional use of the unheated church contributes to significant cooling of the church (even to −8.4 °C in the winter half year). Another conclusion that the computational analysis reveals is that water vapor condensation on the surface of the external walls is impossible. However, the difference between the air temperature in the church and the dew point temperature, specifically in the unheated church, is 1.6 °C. Therefore, at lower outside air temperatures, there may be a risk of water vapor condensation.
- Open Access
Analysis of Greenhouse Gas Emissions and Energy Consumption Depending on the Material and Construction Solutions and the Energy Carrier Used—A Case Study
The article presents the results of research on the impact of material and construction solutions on energy demand and greenhouse gas emissions. Field research was conducted in an existing free-standing greenhouse located in southern Poland. The research period covered the entire calendar year. The measurement data were used in the next step to validate the computational model using the numerical method of elementary balances. The data distribution was also analyzed in terms of basic statistics. The validated and verified model was used in the further part of the analysis to conduct computer simulations for three variants, differing in terms of material and construction solutions. The variants included: no foundation insulation, extruded polystyrene (XPS) insulation and the use of single-chamber polycarbonate panels with thermal insulation of the foundations. The obtained results showed a high agreement between theoretical and real data (85–89% for the coefficient of determination (R2) and 84–88% for the GOF method). In the case of variant 1, which in terms of material and construction solutions corresponded to the actual construction of the greenhouse, it was found that the annual energy demand for heating purposes amounted to 153,234 kWh/year. In variant 2, in which additional thermal insulation relative to the zero state was used, the energy demand for heating purposes was lower and amounted to 147,704 kWh/year. The lowest heat load was characteristic of variant 3, in which 116,294 kWh/year was required to cover heating needs. The variant with polycarbonate and foundation insulation brought energy savings of 24% and a reduction of CO2 emissions by 24%. In addition, replacing fuel from hard coal with natural gas brought significant benefits, reducing pollutant emissions by 51%. The paper is a new approach to the use of the mentioned numerical method for the assessment of gaseous pollutant emissions in this type of building based on numerical simulations of energy consumption.
Open AccessAnalysis of Greenhouse Gas Emissions and Energy Consumption Depending on the Material and Construction Solutions and the Energy Carrier Used—A Case Study
The article presents the results of research on the impact of material and construction solutions on energy demand and greenhouse gas emissions. Field research was conducted in an existing free-standing greenhouse located in southern Poland. The research period covered the entire calendar year. The measurement data were used in the next step to validate the computational model using the numerical method of elementary balances. The data distribution was also analyzed in terms of basic statistics. The validated and verified model was used in the further part of the analysis to conduct computer simulations for three variants, differing in terms of material and construction solutions. The variants included: no foundation insulation, extruded polystyrene (XPS) insulation and the use of single-chamber polycarbonate panels with thermal insulation of the foundations. The obtained results showed a high agreement between theoretical and real data (85–89% for the coefficient of determination (R2) and 84–88% for the GOF method). In the case of variant 1, which in terms of material and construction solutions corresponded to the actual construction of the greenhouse, it was found that the annual energy demand for heating purposes amounted to 153,234 kWh/year. In variant 2, in which additional thermal insulation relative to the zero state was used, the energy demand for heating purposes was lower and amounted to 147,704 kWh/year. The lowest heat load was characteristic of variant 3, in which 116,294 kWh/year was required to cover heating needs. The variant with polycarbonate and foundation insulation brought energy savings of 24% and a reduction of CO2 emissions by 24%. In addition, replacing fuel from hard coal with natural gas brought significant benefits, reducing pollutant emissions by 51%. The paper is a new approach to the use of the mentioned numerical method for the assessment of gaseous pollutant emissions in this type of building based on numerical simulations of energy consumption.
- Open Access
Impact of the Location and Energy Carriers Used on Greenhouse Gas Emissions from a Building
The growth in population increases greenhouse gas (GHG) emissions into the environment. High GHG emissions are attributed to meat production, due to its high energy demand. The largest carbon footprint in the production of poultry meat is generated by combustion. This paper deals with the problem of greenhouse gas emissions (total dust, CO, CO2, NOx, SOx and benzo(a)pyrene) resulting from the generation of energy for heating broiler houses located in different locations in Europe. The study includes continuous measurements of selected microclimate parameters: temperature and relative humidity inside and outside the building, floor temperature, wind speed and direction, and solar radiation intensity. Validation and calibration of the model, emission calculations, and analysis of the obtained results were conducted. Eighteen design variants were assumed, differentiated by the heating fuel used (hard coal, fuel oil, gaseous fuels), material and construction solutions for the floor and the location of the facility. The analysis showed that CO2 emissions for a facility located in northern Europe are 123,153 kg higher compared to the same building located in southern Europe. In addition, increasing the floor’s thermal resistance by 3.69 m2·K·W−1 reduced harmful gas emissions by an average of 5.7% for each of the locations analysed.
Open AccessImpact of the Location and Energy Carriers Used on Greenhouse Gas Emissions from a Building
The growth in population increases greenhouse gas (GHG) emissions into the environment. High GHG emissions are attributed to meat production, due to its high energy demand. The largest carbon footprint in the production of poultry meat is generated by combustion. This paper deals with the problem of greenhouse gas emissions (total dust, CO, CO2, NOx, SOx and benzo(a)pyrene) resulting from the generation of energy for heating broiler houses located in different locations in Europe. The study includes continuous measurements of selected microclimate parameters: temperature and relative humidity inside and outside the building, floor temperature, wind speed and direction, and solar radiation intensity. Validation and calibration of the model, emission calculations, and analysis of the obtained results were conducted. Eighteen design variants were assumed, differentiated by the heating fuel used (hard coal, fuel oil, gaseous fuels), material and construction solutions for the floor and the location of the facility. The analysis showed that CO2 emissions for a facility located in northern Europe are 123,153 kg higher compared to the same building located in southern Europe. In addition, increasing the floor’s thermal resistance by 3.69 m2·K·W−1 reduced harmful gas emissions by an average of 5.7% for each of the locations analysed.
- Open Access
Numerical Analysis of the Effect of Floor Depression on the Extent of Thermal Interaction with the Ground and Energy Management Using a Vegetable Cold Store as an Example
The thermal interaction between cooling facilities and the ground is most often discussed in terms of the appropriate insulation of building partitions. Unfortunately, there is little information about the potential of using ground thermal accumulation to support the shaping of the microclimate in cooling facilities by embedding them in the ground. This problem is particularly important in the context of striving to reduce the energy demand of buildings. The article discusses a new scientific problem related to the effect of vegetable cold storage floors being recessed into the ground on the surrounding land’s impact range and on its energy management. Validation of the numerical model was performed based on actual year-round field surveys. These surveys were conducted in a free-standing vegetable cold storage facility located in southern Poland. The results of the study allowed us to determine the contribution of the land to the energy balance of the cold storage. A floor recessed into the ground doubled the ground’s contribution to the energy balance. The most important research results showed that the range of thermal impact on the surrounding ground also increased by 2.0 m more than that of a building with the floor located at ground level. An evaluation of the heat flow between the cold storage and the ground in the cases analyzed was also carried out. The analysis of the ground heat exchange balance on an annual basis showed high energy gains of 2055 kWh. The total energy demand for cooling was 1723 kWh, while it was 1204 kWh for heating. The results of the analysis of the heat exchange intensity between the indoor air and the ground showed that the ground contribution accounted for 16.6% of the total energy balance of the cold storage. The highest energy gains from the ground were found in October and amounted to 478 kWh. Due to the summer shutdown, there was an intense heat flow to the ground in July, which amounted to 588 kWh.
Open AccessNumerical Analysis of the Effect of Floor Depression on the Extent of Thermal Interaction with the Ground and Energy Management Using a Vegetable Cold Store as an Example
The thermal interaction between cooling facilities and the ground is most often discussed in terms of the appropriate insulation of building partitions. Unfortunately, there is little information about the potential of using ground thermal accumulation to support the shaping of the microclimate in cooling facilities by embedding them in the ground. This problem is particularly important in the context of striving to reduce the energy demand of buildings. The article discusses a new scientific problem related to the effect of vegetable cold storage floors being recessed into the ground on the surrounding land’s impact range and on its energy management. Validation of the numerical model was performed based on actual year-round field surveys. These surveys were conducted in a free-standing vegetable cold storage facility located in southern Poland. The results of the study allowed us to determine the contribution of the land to the energy balance of the cold storage. A floor recessed into the ground doubled the ground’s contribution to the energy balance. The most important research results showed that the range of thermal impact on the surrounding ground also increased by 2.0 m more than that of a building with the floor located at ground level. An evaluation of the heat flow between the cold storage and the ground in the cases analyzed was also carried out. The analysis of the ground heat exchange balance on an annual basis showed high energy gains of 2055 kWh. The total energy demand for cooling was 1723 kWh, while it was 1204 kWh for heating. The results of the analysis of the heat exchange intensity between the indoor air and the ground showed that the ground contribution accounted for 16.6% of the total energy balance of the cold storage. The highest energy gains from the ground were found in October and amounted to 478 kWh. Due to the summer shutdown, there was an intense heat flow to the ground in July, which amounted to 588 kWh.
- Open Access
Possibility of Using Waste Materials as Substitutes for Gravel or Water in Concrete Mix
Analyzing the global waste management sector, we can see that some waste, due to its specificity, is a major challenge when it comes to its management. This group includes rubber waste and sewage sludge. Both items pose a major threat to the environment and human health. The remedy for this problem may be the solidification process, in which the presented wastes are used as substrates in the production of concrete. The aim of this work was to determine the effect of waste addition to cement in the form of an active additive (sewage sludge) and a passive additive (rubber granulate). An unusual approach to sewage sludge was used, which was introduced as a substitute for water, and not, as in most works, sewage sludge ash. In the case of the second waste, commonly used tire granules were replaced with rubber particles resulting from the fragmentation of conveyor belts. A wide range of the share of additives in the cement mortar was analyzed. The results for the rubber granulate were consistent with numerous publications. For the addition in the form of hydrated sewage sludge, the deterioration of the mechanical properties of concrete was demonstrated. It was found that the flexural strength of the concrete in which water was replaced with hydrated sewage sludge was lower than that of the sample without the addition of sludge. The compressive strength of concrete with the addition of rubber granules was higher than the control sample and did not significantly depend on the amount of granulate used.
Open AccessPossibility of Using Waste Materials as Substitutes for Gravel or Water in Concrete Mix
Analyzing the global waste management sector, we can see that some waste, due to its specificity, is a major challenge when it comes to its management. This group includes rubber waste and sewage sludge. Both items pose a major threat to the environment and human health. The remedy for this problem may be the solidification process, in which the presented wastes are used as substrates in the production of concrete. The aim of this work was to determine the effect of waste addition to cement in the form of an active additive (sewage sludge) and a passive additive (rubber granulate). An unusual approach to sewage sludge was used, which was introduced as a substitute for water, and not, as in most works, sewage sludge ash. In the case of the second waste, commonly used tire granules were replaced with rubber particles resulting from the fragmentation of conveyor belts. A wide range of the share of additives in the cement mortar was analyzed. The results for the rubber granulate were consistent with numerous publications. For the addition in the form of hydrated sewage sludge, the deterioration of the mechanical properties of concrete was demonstrated. It was found that the flexural strength of the concrete in which water was replaced with hydrated sewage sludge was lower than that of the sample without the addition of sludge. The compressive strength of concrete with the addition of rubber granules was higher than the control sample and did not significantly depend on the amount of granulate used.
- Open Access
Numerical Analysis of Thermal Impact between the Cooling Facility and the Ground
The article presents the results of research on the range of the impact of a cooling facility on the surrounding ground. An analysis of the heat exchange with the ground and through the building partitions was carried out. The analysis was carried out on the basis of the results of actual field tests carried out throughout the measurement year. The object of the research was an agricultural cold store located in southern Poland. The computational analysis of the interaction between the cooling facility and the ground was based on the numerical elementary balances method. The validation of the calculation model was performed based on the adopted boundary conditions. Calculations for the analyzed variants were carried out on the basis of a geometric model of the cooling facility built in the WUFI®plus program, corresponding to the actual dimensions. The analysis of the energy balance of the studied facility showed that the share of energy flow through the floor to the ground constitutes 8.2% of all energy flows through other partitions and the ventilation system. In order to maintain the set air temperature inside the studied building, intensive cooling was required with an energy demand of 5184.5 kWh/year. The results of the research showed that the range of the thermal impact of the building changes depending on the location of the studied ground area in terms of cardinal direction. The external and internal microclimate characteristics also affect the extent of the impact of the cooling facility on the surrounding ground. Under the assumption of stable values of Θi within a range of 0.0–4.0 °C, the largest range of influence (4.0 m) occurs in the summer.
Open AccessNumerical Analysis of Thermal Impact between the Cooling Facility and the Ground
The article presents the results of research on the range of the impact of a cooling facility on the surrounding ground. An analysis of the heat exchange with the ground and through the building partitions was carried out. The analysis was carried out on the basis of the results of actual field tests carried out throughout the measurement year. The object of the research was an agricultural cold store located in southern Poland. The computational analysis of the interaction between the cooling facility and the ground was based on the numerical elementary balances method. The validation of the calculation model was performed based on the adopted boundary conditions. Calculations for the analyzed variants were carried out on the basis of a geometric model of the cooling facility built in the WUFI®plus program, corresponding to the actual dimensions. The analysis of the energy balance of the studied facility showed that the share of energy flow through the floor to the ground constitutes 8.2% of all energy flows through other partitions and the ventilation system. In order to maintain the set air temperature inside the studied building, intensive cooling was required with an energy demand of 5184.5 kWh/year. The results of the research showed that the range of the thermal impact of the building changes depending on the location of the studied ground area in terms of cardinal direction. The external and internal microclimate characteristics also affect the extent of the impact of the cooling facility on the surrounding ground. Under the assumption of stable values of Θi within a range of 0.0–4.0 °C, the largest range of influence (4.0 m) occurs in the summer.
- Open Access
Interaction between a Cyclically Heated Building and the Ground, for Selected Locations in Europe
The aim of the study was to verify the impact of the location of a cyclically heated building on its energy needs and interaction with the environment. The model building was a large-scale broiler house located in southern Poland. In the examined facility, year-round measurements of selected parameters of the internal and external microclimate were carried out. The tests also covered the temperature of the soil in three measurement columns. The obtained measurement results were used for further computer analyses. A geometric model of the building was made and a calculation model specification was introduced, supported by specialized software for the physics of WUFI®plus structures. The numerical analysis included validation. The validation results were assessed on the basis of the Coefficient of Determination method (R2) and the Goodness of Fit (GOF) method. Due to the lack of normality of the data distribution, a Rang-Spearman correlation analysis was carried out, which showed a very strong data correlation (0.94). The analysis of the R2 coefficient of determination confirmed the high reliability of the model (83%). In the case of the GOF method, a compliance value of 87% was obtained. Differentiated locations were adopted for further analysis, while maintaining the structure of the examined building in reality. Six European locations were selected: Kraków (Poland), Málaga (Spain), Brest (France), Visby (Sweden), Umea (Sweden), and Kiruna (Sweden). The analysis included three variants, in which the length of the technological break was adopted accordingly. A technological break between production cycles was assumed, the three variants of which lasted 3, 7, and 14 days. The analysis of the obtained results showed that the external microclimate significantly determines the energy interaction between the building and the ground. The length of the technological break is very important in a climate dominated by low temperatures (Northern Scandinavia). The south-western part of Europe allows the technological break to be extended without significant differences for heating purposes. The length of the technological break in the range of 3 to 14 days does not significantly affect the intensity of heat exchange with the ground on a yearly basis, regardless of the location of the building. There were differences of no more than 2% between the technological break lasting 3 days and the 14-day break.
Open AccessInteraction between a Cyclically Heated Building and the Ground, for Selected Locations in Europe
The aim of the study was to verify the impact of the location of a cyclically heated building on its energy needs and interaction with the environment. The model building was a large-scale broiler house located in southern Poland. In the examined facility, year-round measurements of selected parameters of the internal and external microclimate were carried out. The tests also covered the temperature of the soil in three measurement columns. The obtained measurement results were used for further computer analyses. A geometric model of the building was made and a calculation model specification was introduced, supported by specialized software for the physics of WUFI®plus structures. The numerical analysis included validation. The validation results were assessed on the basis of the Coefficient of Determination method (R2) and the Goodness of Fit (GOF) method. Due to the lack of normality of the data distribution, a Rang-Spearman correlation analysis was carried out, which showed a very strong data correlation (0.94). The analysis of the R2 coefficient of determination confirmed the high reliability of the model (83%). In the case of the GOF method, a compliance value of 87% was obtained. Differentiated locations were adopted for further analysis, while maintaining the structure of the examined building in reality. Six European locations were selected: Kraków (Poland), Málaga (Spain), Brest (France), Visby (Sweden), Umea (Sweden), and Kiruna (Sweden). The analysis included three variants, in which the length of the technological break was adopted accordingly. A technological break between production cycles was assumed, the three variants of which lasted 3, 7, and 14 days. The analysis of the obtained results showed that the external microclimate significantly determines the energy interaction between the building and the ground. The length of the technological break is very important in a climate dominated by low temperatures (Northern Scandinavia). The south-western part of Europe allows the technological break to be extended without significant differences for heating purposes. The length of the technological break in the range of 3 to 14 days does not significantly affect the intensity of heat exchange with the ground on a yearly basis, regardless of the location of the building. There were differences of no more than 2% between the technological break lasting 3 days and the 14-day break.
- Open Access
Analysis of the Impact of Flooring Material and Construction Solutions on Heat Exchange with the Ground in a Historic Wooden Building
The article deals with the issue of the influence of selected material and construction solutions for a floor in a historic wooden building on heat exchange with the ground. The scope of the work included continuous measurements of selected parameters of internal and external microclimate, which were later used for numerical analysis of selected calculation variants. The research was carried out in a historic wooden church located in southern Poland. The research period covered 2019, while all measurements were performed every 1 h. For the variant analysis, a building with a wooden and stone floor was adopted. The influence of the heating system on the heat exchange with the ground for wooden and stone floors was also analysed. As a result of a detailed analysis, it was found that the material and construction solutions, as well as the heating system, have a significant impact on the formation of heat exchange with the ground. The building with a wooden floor was characterised by significantly higher values of energy losses to the ground in relation to heat gains. During the year, the total energy losses to land amounted to 1005 kWh, while the gain was 47 kWh. The energy flow from inside the building to the ground in August was 2.4 times higher in variant 2 than in variant 1. In February, heat losses to the ground were 1.6 times higher in variant 2 compared to variant 1.
Open AccessAnalysis of the Impact of Flooring Material and Construction Solutions on Heat Exchange with the Ground in a Historic Wooden Building
The article deals with the issue of the influence of selected material and construction solutions for a floor in a historic wooden building on heat exchange with the ground. The scope of the work included continuous measurements of selected parameters of internal and external microclimate, which were later used for numerical analysis of selected calculation variants. The research was carried out in a historic wooden church located in southern Poland. The research period covered 2019, while all measurements were performed every 1 h. For the variant analysis, a building with a wooden and stone floor was adopted. The influence of the heating system on the heat exchange with the ground for wooden and stone floors was also analysed. As a result of a detailed analysis, it was found that the material and construction solutions, as well as the heating system, have a significant impact on the formation of heat exchange with the ground. The building with a wooden floor was characterised by significantly higher values of energy losses to the ground in relation to heat gains. During the year, the total energy losses to land amounted to 1005 kWh, while the gain was 47 kWh. The energy flow from inside the building to the ground in August was 2.4 times higher in variant 2 than in variant 1. In February, heat losses to the ground were 1.6 times higher in variant 2 compared to variant 1.