Ji Young Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ji Young Kim has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Jae-Ho Lee
Department of Information Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
5 shared publications - Yu Rang Park
Department of Biomedical Systems Informatics, Yonsei University College of Medicine, Seoul, Republic of Korea
5 shared publications - Yura Lee
Department of Information Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
5 shared publications - Hae Reong Kim
Department of Biomedical Systems Informatics, Yonsei University College of Medicine, Seoul, Republic of Korea
3 shared publications - Jeong Hoon Kim
Medical Information Office, Asan Medical Center, Seoul, Republic of Korea
3 shared publications - Woo Sung Kim
Department of Biomedical Informatics, Asan Medical Center, Seoul, Republic of Korea
3 shared publications
Latest Publications
- Open Access
- 2 June 2020
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 22 (6) , e15372
The Use of Mobile Personal Health Records for Hemoglobin A1c Regulation in Patients With Diabetes: Retrospective Observational Study
Background: The effectiveness of personal health records (PHRs) in diabetes management has already been verified in several clinical trials; however, evidence of their effectiveness in real-world scenarios is also necessary. To provide solid real-world evidence, an analysis that is more accurate than the analyses solely based on patient-generated health data should be conducted. Objective: This study aimed to conduct a more accurate analysis of the effectiveness of using PHRs within electronic medical records (EMRs). The results of this study will provide precise real-world evidence of PHRs as a feasible diabetes management tool. Methods: We collected log data of the sugar function in the My Chart in My Hand version 2.0 (MCMH 2.0) app from Asan Medical Center (AMC), Seoul, Republic of Korea, between December 2015 and April 2018. The EMR data of MCMH 2.0 users from AMC were collected and integrated with the PHR data. We classified users according to whether they were continuous app users. We analyzed and compared their characteristics, patterns of hemoglobin A1c (HbA1c) levels, and the proportion of successful HbA1c control. The following confounders were adjusted for HbA1c pattern analysis and HbA1c regulation proportion comparison: age, sex, first HbA1c measurement, diabetes complications severity index score, sugar function data generation weeks, HbA1c measurement weeks before MCMH 2.0 start, and generated sugar function data count. Results: The total number of MCMH 2.0 users was 64,932, with 7453 users having appropriate PHRs and diabetes criteria. The number of continuous and noncontinuous users was 133 and 7320, respectively. Compared with noncontinuous users, continuous users were younger (P<.001) and had a higher male proportion (P<.001). Furthermore, continuous users had more frequent HbA1c measurements (P=.007), shorter HbA1c measurement days (P=.04), and a shorter period between the first HbA1c measurement and MCMH 2.0 start (P<.001). Diabetes severity–related factors were not statistically significantly different between the two groups. Continuous users had a higher decrease in HbA1c (P=.02) and a higher proportion of regulation of HbA1c levels to the target level (P=.01). After adjusting the confounders, continuous users had more decline in HbA1c levels than noncontinuous users (P=.047). Of the users who had a first HbA1c measurement higher than 6.5% (111 continuous users and 5716 noncontinuous users), continuous users had better regulation of HbA1c levels with regard to the target level, 6.5%, which was statistically significant (P=.04). Conclusions: By integrating and analyzing patient- and clinically generated data, we demonstrated that the continuous use of PHRs improved diabetes management outcomes. In addition, the HbA1c reduction pattern was prominent in the PHR continuous user group. Although the continued use of PHRs has proven to be effective in managing diabetes, further evaluation of its effectiveness for various diseases and a study on PHR adherence are also required.
- 2 June 2020
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 22 (6) , e15372
Open AccessThe Use of Mobile Personal Health Records for Hemoglobin A1c Regulation in Patients With Diabetes: Retrospective Observational Study
Background: The effectiveness of personal health records (PHRs) in diabetes management has already been verified in several clinical trials; however, evidence of their effectiveness in real-world scenarios is also necessary. To provide solid real-world evidence, an analysis that is more accurate than the analyses solely based on patient-generated health data should be conducted. Objective: This study aimed to conduct a more accurate analysis of the effectiveness of using PHRs within electronic medical records (EMRs). The results of this study will provide precise real-world evidence of PHRs as a feasible diabetes management tool. Methods: We collected log data of the sugar function in the My Chart in My Hand version 2.0 (MCMH 2.0) app from Asan Medical Center (AMC), Seoul, Republic of Korea, between December 2015 and April 2018. The EMR data of MCMH 2.0 users from AMC were collected and integrated with the PHR data. We classified users according to whether they were continuous app users. We analyzed and compared their characteristics, patterns of hemoglobin A1c (HbA1c) levels, and the proportion of successful HbA1c control. The following confounders were adjusted for HbA1c pattern analysis and HbA1c regulation proportion comparison: age, sex, first HbA1c measurement, diabetes complications severity index score, sugar function data generation weeks, HbA1c measurement weeks before MCMH 2.0 start, and generated sugar function data count. Results: The total number of MCMH 2.0 users was 64,932, with 7453 users having appropriate PHRs and diabetes criteria. The number of continuous and noncontinuous users was 133 and 7320, respectively. Compared with noncontinuous users, continuous users were younger (P<.001) and had a higher male proportion (P<.001). Furthermore, continuous users had more frequent HbA1c measurements (P=.007), shorter HbA1c measurement days (P=.04), and a shorter period between the first HbA1c measurement and MCMH 2.0 start (P<.001). Diabetes severity–related factors were not statistically significantly different between the two groups. Continuous users had a higher decrease in HbA1c (P=.02) and a higher proportion of regulation of HbA1c levels to the target level (P=.01). After adjusting the confounders, continuous users had more decline in HbA1c levels than noncontinuous users (P=.047). Of the users who had a first HbA1c measurement higher than 6.5% (111 continuous users and 5716 noncontinuous users), continuous users had better regulation of HbA1c levels with regard to the target level, 6.5%, which was statistically significant (P=.04). Conclusions: By integrating and analyzing patient- and clinically generated data, we demonstrated that the continuous use of PHRs improved diabetes management outcomes. In addition, the HbA1c reduction pattern was prominent in the PHR continuous user group. Although the continued use of PHRs has proven to be effective in managing diabetes, further evaluation of its effectiveness for various diseases and a study on PHR adherence are also required.
- Open Access
- 5 July 2019
- Published by JMIR Publications Inc. in JMIR Preprints
The Use of Mobile Personal Health Records for Hemoglobin A1c Regulation in Patients With Diabetes: Retrospective Observational Study (Preprint)
BACKGROUND The effectiveness of personal health records (PHRs) in diabetes management has already been verified in several clinical trials; however, evidence of their effectiveness in real-world scenarios is also necessary. To provide solid real-world evidence, an analysis that is more accurate than the analyses solely based on patient-generated health data should be conducted. OBJECTIVE This study aimed to conduct a more accurate analysis of the effectiveness of using PHRs within electronic medical records (EMRs). The results of this study will provide precise real-world evidence of PHRs as a feasible diabetes management tool. METHODS We collected log data of the sugar function in the My Chart in My Hand version 2.0 (MCMH 2.0) app from Asan Medical Center (AMC), Seoul, Republic of Korea, between December 2015 and April 2018. The EMR data of MCMH 2.0 users from AMC were collected and integrated with the PHR data. We classified users according to whether they were continuous app users. We analyzed and compared their characteristics, patterns of hemoglobin A1c (HbA1c) levels, and the proportion of successful HbA1c control. The following confounders were adjusted for HbA1c pattern analysis and HbA1c regulation proportion comparison: age, sex, first HbA1c measurement, diabetes complications severity index score, sugar function data generation weeks, HbA1c measurement weeks before MCMH 2.0 start, and generated sugar function data count. RESULTS The total number of MCMH 2.0 users was 64,932, with 7453 users having appropriate PHRs and diabetes criteria. The number of continuous and noncontinuous users was 133 and 7320, respectively. Compared with noncontinuous users, continuous users were younger (P<.001) and had a higher male proportion (P<.001). Furthermore, continuous users had more frequent HbA1c measurements (P=.007), shorter HbA1c measurement days (P=.04), and a shorter period between the first HbA1c measurement and MCMH 2.0 start (P<.001). Diabetes severity–related factors were not statistically significantly different between the two groups. Continuous users had a higher decrease in HbA1c (P=.02) and a higher proportion of regulation of HbA1c levels to the target level (P=.01). After adjusting the confounders, continuous users had more decline in HbA1c levels than noncontinuous users (P=.047). Of the users who had a first HbA1c measurement higher than 6.5% (111 continuous users and 5716 noncontinuous users), continuous users had better regulation of HbA1c levels with regard to the target level, 6.5%, which was statistically significant (P=.04). CONCLUSIONS By integrating and analyzing patient- and clinically generated data, we demonstrated that the continuous use of PHRs improved diabetes management outcomes. In addition, the HbA1c reduction pattern was prominent in the PHR continuous user group. Although the continued use of PHRs has proven to be effective in managing diabetes, further evaluation of its effectiveness for various diseases and a study on PHR adherence are also required.
- 5 July 2019
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessThe Use of Mobile Personal Health Records for Hemoglobin A1c Regulation in Patients With Diabetes: Retrospective Observational Study (Preprint)
BACKGROUND The effectiveness of personal health records (PHRs) in diabetes management has already been verified in several clinical trials; however, evidence of their effectiveness in real-world scenarios is also necessary. To provide solid real-world evidence, an analysis that is more accurate than the analyses solely based on patient-generated health data should be conducted. OBJECTIVE This study aimed to conduct a more accurate analysis of the effectiveness of using PHRs within electronic medical records (EMRs). The results of this study will provide precise real-world evidence of PHRs as a feasible diabetes management tool. METHODS We collected log data of the sugar function in the My Chart in My Hand version 2.0 (MCMH 2.0) app from Asan Medical Center (AMC), Seoul, Republic of Korea, between December 2015 and April 2018. The EMR data of MCMH 2.0 users from AMC were collected and integrated with the PHR data. We classified users according to whether they were continuous app users. We analyzed and compared their characteristics, patterns of hemoglobin A1c (HbA1c) levels, and the proportion of successful HbA1c control. The following confounders were adjusted for HbA1c pattern analysis and HbA1c regulation proportion comparison: age, sex, first HbA1c measurement, diabetes complications severity index score, sugar function data generation weeks, HbA1c measurement weeks before MCMH 2.0 start, and generated sugar function data count. RESULTS The total number of MCMH 2.0 users was 64,932, with 7453 users having appropriate PHRs and diabetes criteria. The number of continuous and noncontinuous users was 133 and 7320, respectively. Compared with noncontinuous users, continuous users were younger (P<.001) and had a higher male proportion (P<.001). Furthermore, continuous users had more frequent HbA1c measurements (P=.007), shorter HbA1c measurement days (P=.04), and a shorter period between the first HbA1c measurement and MCMH 2.0 start (P<.001). Diabetes severity–related factors were not statistically significantly different between the two groups. Continuous users had a higher decrease in HbA1c (P=.02) and a higher proportion of regulation of HbA1c levels to the target level (P=.01). After adjusting the confounders, continuous users had more decline in HbA1c levels than noncontinuous users (P=.047). Of the users who had a first HbA1c measurement higher than 6.5% (111 continuous users and 5716 noncontinuous users), continuous users had better regulation of HbA1c levels with regard to the target level, 6.5%, which was statistically significant (P=.04). CONCLUSIONS By integrating and analyzing patient- and clinically generated data, we demonstrated that the continuous use of PHRs improved diabetes management outcomes. In addition, the HbA1c reduction pattern was prominent in the PHR continuous user group. Although the continued use of PHRs has proven to be effective in managing diabetes, further evaluation of its effectiveness for various diseases and a study on PHR adherence are also required.
- Open Access
- 9 April 2018
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 6 (4) , e89
Managing Patient-Generated Health Data Through Mobile Personal Health Records: Analysis of Usage Data
Mobile and tablet apps, ubiquitous and pervasive computing, wearable computing and domotics for health.
- 9 April 2018
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 6 (4) , e89
Open AccessManaging Patient-Generated Health Data Through Mobile Personal Health Records: Analysis of Usage Data
Mobile and tablet apps, ubiquitous and pervasive computing, wearable computing and domotics for health.
- Open Access
- 11 December 2017
- Published by JMIR Publications Inc. in JMIR Preprints
Managing Patient-Generated Health Data Through Mobile Personal Health Records: Analysis of Usage Data
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Personal health records (PHRs) and mHealth apps are considered essential tools for patient engagement. Mobile PHRs (mPHRs) can be a platform to integrate patient-generated health data (PGHD) and patients’ medical information. However, in previous studies, actual usage data and PGHD from mPHRs have not been able to adequately represent patient engagement. Objective: By analyzing 5 years’ PGHD from an mPHR system developed by a tertiary hospital in South Korea, we aimed to evaluate how PGHD were managed and identify issues in PGHD management based on actual usage data. Additionally, we analyzed how to improve patient engagement with mPHRs by analyzing the actively used services and long-term usage patterns. Methods: We gathered 5 years (December 2010 to December 2015) of log data from both hospital patients and general users of the app. We gathered data from users who entered PGHD on body weight, blood pressure (BP), blood glucose levels, 10-year cardiovascular disease (CVD) risk, metabolic syndrome risk, medication schedule, insulin, and allergy. We classified users according to whether they were patients or general users based on factors related to continuous use (≥28 days for weight, BP, and blood glucose, and ≥180 days for CVD and metabolic syndrome), and analyzed the patients’ characteristics. We compared PGHD entry counts and the proportion of continuous users for each PGHD by user type. Results: The total number of mPHR users was 18,265 (patients: n=16,729, 91.59%) with 3620 users having entered weight, followed by BP (n=1625), blood glucose (n=1374), CVD (n=764), metabolic syndrome (n=685), medication (n=252), insulin (n=72), and allergy (n=61). Of those 18,256 users, 3812 users had at least one PGHD measurement, of whom 175 used the PGHD functions continuously (patients: n=142, 81.14%); less than 1% of the users had used it for more than 4 years. Except for weight, BP, blood glucose, CVD, and metabolic syndrome, the number of PGHD records declined. General users’ continuous use of PGHD was significantly higher than that of patients in the blood glucose (P<.001) and BP (P=.03) functions. Continuous use of PGHD in health management (BP, blood glucose, and weight) was significantly greater among older users (P<.001) and men (P<.001). In health management (BP, weight, and blood glucose), overall chronic disease and continuous use of PGHD were not statistically related (P=.08), but diabetes (P<.001) and cerebrovascular diseases (P=.03) were significant. Conclusions: Although a small portion of users managed PGHD continuously, PGHD has the potential to be useful in monitoring patient health. To realize the potential, specific groups of continuous users must be identified, and the PGHD service must target them. Further evaluations for the clinical application of PGHD, feedback regarding user interfaces, and connections with wearable devices are needed.
- 11 December 2017
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessManaging Patient-Generated Health Data Through Mobile Personal Health Records: Analysis of Usage Data
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Personal health records (PHRs) and mHealth apps are considered essential tools for patient engagement. Mobile PHRs (mPHRs) can be a platform to integrate patient-generated health data (PGHD) and patients’ medical information. However, in previous studies, actual usage data and PGHD from mPHRs have not been able to adequately represent patient engagement. Objective: By analyzing 5 years’ PGHD from an mPHR system developed by a tertiary hospital in South Korea, we aimed to evaluate how PGHD were managed and identify issues in PGHD management based on actual usage data. Additionally, we analyzed how to improve patient engagement with mPHRs by analyzing the actively used services and long-term usage patterns. Methods: We gathered 5 years (December 2010 to December 2015) of log data from both hospital patients and general users of the app. We gathered data from users who entered PGHD on body weight, blood pressure (BP), blood glucose levels, 10-year cardiovascular disease (CVD) risk, metabolic syndrome risk, medication schedule, insulin, and allergy. We classified users according to whether they were patients or general users based on factors related to continuous use (≥28 days for weight, BP, and blood glucose, and ≥180 days for CVD and metabolic syndrome), and analyzed the patients’ characteristics. We compared PGHD entry counts and the proportion of continuous users for each PGHD by user type. Results: The total number of mPHR users was 18,265 (patients: n=16,729, 91.59%) with 3620 users having entered weight, followed by BP (n=1625), blood glucose (n=1374), CVD (n=764), metabolic syndrome (n=685), medication (n=252), insulin (n=72), and allergy (n=61). Of those 18,256 users, 3812 users had at least one PGHD measurement, of whom 175 used the PGHD functions continuously (patients: n=142, 81.14%); less than 1% of the users had used it for more than 4 years. Except for weight, BP, blood glucose, CVD, and metabolic syndrome, the number of PGHD records declined. General users’ continuous use of PGHD was significantly higher than that of patients in the blood glucose (P<.001) and BP (P=.03) functions. Continuous use of PGHD in health management (BP, blood glucose, and weight) was significantly greater among older users (P<.001) and men (P<.001). In health management (BP, weight, and blood glucose), overall chronic disease and continuous use of PGHD were not statistically related (P=.08), but diabetes (P<.001) and cerebrovascular diseases (P=.03) were significant. Conclusions: Although a small portion of users managed PGHD continuously, PGHD has the potential to be useful in monitoring patient health. To realize the potential, specific groups of continuous users must be identified, and the PGHD service must target them. Further evaluations for the clinical application of PGHD, feedback regarding user interfaces, and connections with wearable devices are needed.
- Open Access
- 11 December 2017
- Published by JMIR Publications Inc. in JMIR Preprints
Managing Patient-Generated Health Data Through Mobile Personal Health Records: Analysis of Usage Data (Preprint)
BACKGROUND Personal health records (PHRs) and mHealth apps are considered essential tools for patient engagement. Mobile PHRs (mPHRs) can be a platform to integrate patient-generated health data (PGHD) and patients’ medical information. However, in previous studies, actual usage data and PGHD from mPHRs have not been able to adequately represent patient engagement. OBJECTIVE By analyzing 5 years’ PGHD from an mPHR system developed by a tertiary hospital in South Korea, we aimed to evaluate how PGHD were managed and identify issues in PGHD management based on actual usage data. Additionally, we analyzed how to improve patient engagement with mPHRs by analyzing the actively used services and long-term usage patterns. METHODS We gathered 5 years (December 2010 to December 2015) of log data from both hospital patients and general users of the app. We gathered data from users who entered PGHD on body weight, blood pressure (BP), blood glucose levels, 10-year cardiovascular disease (CVD) risk, metabolic syndrome risk, medication schedule, insulin, and allergy. We classified users according to whether they were patients or general users based on factors related to continuous use (≥28 days for weight, BP, and blood glucose, and ≥180 days for CVD and metabolic syndrome), and analyzed the patients’ characteristics. We compared PGHD entry counts and the proportion of continuous users for each PGHD by user type. RESULTS The total number of mPHR users was 18,265 (patients: n=16,729, 91.59%) with 3620 users having entered weight, followed by BP (n=1625), blood glucose (n=1374), CVD (n=764), metabolic syndrome (n=685), medication (n=252), insulin (n=72), and allergy (n=61). Of those 18,256 users, 3812 users had at least one PGHD measurement, of whom 175 used the PGHD functions continuously (patients: n=142, 81.14%); less than 1% of the users had used it for more than 4 years. Except for weight, BP, blood glucose, CVD, and metabolic syndrome, the number of PGHD records declined. General users’ continuous use of PGHD was significantly higher than that of patients in the blood glucose (P<.001) and BP (P=.03) functions. Continuous use of PGHD in health management (BP, blood glucose, and weight) was significantly greater among older users (P<.001) and men (P<.001). In health management (BP, weight, and blood glucose), overall chronic disease and continuous use of PGHD were not statistically related (P=.08), but diabetes (P<.001) and cerebrovascular diseases (P=.03) were significant. CONCLUSIONS Although a small portion of users managed PGHD continuously, PGHD has the potential to be useful in monitoring patient health. To realize the potential, specific groups of continuous users must be identified, and the PGHD service must target them. Further evaluations for the clinical application of PGHD, feedback regarding user interfaces, and connections with wearable devices are needed.
- 11 December 2017
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessManaging Patient-Generated Health Data Through Mobile Personal Health Records: Analysis of Usage Data (Preprint)
BACKGROUND Personal health records (PHRs) and mHealth apps are considered essential tools for patient engagement. Mobile PHRs (mPHRs) can be a platform to integrate patient-generated health data (PGHD) and patients’ medical information. However, in previous studies, actual usage data and PGHD from mPHRs have not been able to adequately represent patient engagement. OBJECTIVE By analyzing 5 years’ PGHD from an mPHR system developed by a tertiary hospital in South Korea, we aimed to evaluate how PGHD were managed and identify issues in PGHD management based on actual usage data. Additionally, we analyzed how to improve patient engagement with mPHRs by analyzing the actively used services and long-term usage patterns. METHODS We gathered 5 years (December 2010 to December 2015) of log data from both hospital patients and general users of the app. We gathered data from users who entered PGHD on body weight, blood pressure (BP), blood glucose levels, 10-year cardiovascular disease (CVD) risk, metabolic syndrome risk, medication schedule, insulin, and allergy. We classified users according to whether they were patients or general users based on factors related to continuous use (≥28 days for weight, BP, and blood glucose, and ≥180 days for CVD and metabolic syndrome), and analyzed the patients’ characteristics. We compared PGHD entry counts and the proportion of continuous users for each PGHD by user type. RESULTS The total number of mPHR users was 18,265 (patients: n=16,729, 91.59%) with 3620 users having entered weight, followed by BP (n=1625), blood glucose (n=1374), CVD (n=764), metabolic syndrome (n=685), medication (n=252), insulin (n=72), and allergy (n=61). Of those 18,256 users, 3812 users had at least one PGHD measurement, of whom 175 used the PGHD functions continuously (patients: n=142, 81.14%); less than 1% of the users had used it for more than 4 years. Except for weight, BP, blood glucose, CVD, and metabolic syndrome, the number of PGHD records declined. General users’ continuous use of PGHD was significantly higher than that of patients in the blood glucose (P<.001) and BP (P=.03) functions. Continuous use of PGHD in health management (BP, blood glucose, and weight) was significantly greater among older users (P<.001) and men (P<.001). In health management (BP, weight, and blood glucose), overall chronic disease and continuous use of PGHD were not statistically related (P=.08), but diabetes (P<.001) and cerebrovascular diseases (P=.03) were significant. CONCLUSIONS Although a small portion of users managed PGHD continuously, PGHD has the potential to be useful in monitoring patient health. To realize the potential, specific groups of continuous users must be identified, and the PGHD service must target them. Further evaluations for the clinical application of PGHD, feedback regarding user interfaces, and connections with wearable devices are needed.