Shaheryar Ahmed Khan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shaheryar Ahmed Khan has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Chrishan Gunasekera
Ophthalmology Department, Norfolk & Norwich University Hospital, Norwich, UK
2 shared publicationsAchim Richard Nestel
North Devon District Hospital, Barnstaple, Devon, UK
1 shared publicationCaspar Gibbon
North Devon District Hospital, Barnstaple, UK
1 shared publicationCraig Goldsmith
Ophthalmology Department, James Paget University Hospital, Great Yarmouth, UK
1 shared publicationKarl Whittaker
North Devon District Hospital, Barnstaple, UK
1 shared publicationMuhammad Aslam Razzaq
North Devon District Hospital, Barnstaple, UK
1 shared publication
Latest Publications
- 21 January 2025
- Published by Springer Nature in Eye
- Vol. 39 (7) , 1301-1308
“Comparative analysis of large language models against the NHS 111 online triaging for emergency ophthalmology”
Background This study presents a comprehensive evaluation of the performance of various large language models in generating responses for ophthalmology emergencies and compares their accuracy with the established United Kingdom’s National Health Service 111 online system. Methods We included 21 ophthalmology-related emergency scenario questions from the NHS 111 triaging algorithm. These questions were based on four different ophthalmology emergency themes as laid out in the NHS 111 algorithm. Responses generated from NHS 111 online, were compared to different LLM-chatbots responses to determine the accuracy of LLM responses. We included a range of models including ChatGPT-3.5, Google Bard, Bing Chat, and ChatGPT-4.0. The accuracy of each LLM-chatbot response was compared against the NHS 111 Triage using a two-prompt strategy. Answers were graded as following: −2 graded as “Very poor”, −1 as “Poor”, O as “No response”, 1 as “Good”, 2 as “Very good” and 3 graded as “Excellent”. Results Overall LLMs’ attained a good accuracy in this study compared against the NHS 111 responses. The score of ≥1 graded as “Good” was achieved by 93% responses of all LLMs. This refers to at least part of this answer having correct information as well as absence of any wrong information. There was no marked difference and very similar results seen overall on both prompts. Conclusions The high accuracy and safety observed in LLM responses support their potential as effective tools for providing timely information and guidance to patients. LLMs hold promise in enhancing patient care and healthcare accessibility in digital age.
- 21 January 2025
- Published by Springer Nature in Eye
- Vol. 39 (7) , 1301-1308
“Comparative analysis of large language models against the NHS 111 online triaging for emergency ophthalmology”
Background This study presents a comprehensive evaluation of the performance of various large language models in generating responses for ophthalmology emergencies and compares their accuracy with the established United Kingdom’s National Health Service 111 online system. Methods We included 21 ophthalmology-related emergency scenario questions from the NHS 111 triaging algorithm. These questions were based on four different ophthalmology emergency themes as laid out in the NHS 111 algorithm. Responses generated from NHS 111 online, were compared to different LLM-chatbots responses to determine the accuracy of LLM responses. We included a range of models including ChatGPT-3.5, Google Bard, Bing Chat, and ChatGPT-4.0. The accuracy of each LLM-chatbot response was compared against the NHS 111 Triage using a two-prompt strategy. Answers were graded as following: −2 graded as “Very poor”, −1 as “Poor”, O as “No response”, 1 as “Good”, 2 as “Very good” and 3 graded as “Excellent”. Results Overall LLMs’ attained a good accuracy in this study compared against the NHS 111 responses. The score of ≥1 graded as “Good” was achieved by 93% responses of all LLMs. This refers to at least part of this answer having correct information as well as absence of any wrong information. There was no marked difference and very similar results seen overall on both prompts. Conclusions The high accuracy and safety observed in LLM responses support their potential as effective tools for providing timely information and guidance to patients. LLMs hold promise in enhancing patient care and healthcare accessibility in digital age.
- Open Access
- 11 August 2024
- Published by Springer Nature in Research Square
Comparative Analysis of Large Language Models against the NHS 111 Online Triaging for Emergency Ophthalmology
Background This study presents a comprehensive evaluation of the performance of various language models in generating responses for ophthalmology emergencies and compares their accuracy with the established NHS 111 online Triage system.Methods We included 21 ophthalmology related emergency scenario questions from the 111 triaging algorithm. These questions were based on four different ophthalmology emergency themes as laid out in the NHS 111 algorithm. The responses generated from NHS 111 online, were compared to the different LLM-chatbots responses. We included a range of models including ChatGPT-3.5, Google Bard, Bing Chat, and ChatGPT-4.0. The accuracy of each LLM-chatbot response was compared against the NHS 111 Triage using a two prompt strategy. Answers were graded separately by two different authors as following: −2 graded as “Very poor”, -1 as “Poor”, 0 as “No response”, 1 as “Good”, 2 as “Very good” and 3 graded as “Excellent”.Results Overall score of ≥ 1 graded as “Good” or better was achieved by 93% of responses of all LLMs. This refers to at least part of the answer having correct information and partially matching NHS 111 response, as well as the absence of any wrong information or advice which is potentially harmful to the patient’s health.Conclusions The high accuracy and safety observed in LLM responses support their potential as effective tools for providing timely information and guidance to patients. While further research is warranted to validate these findings in clinical practice, LLMs hold promise in enhancing patient care and healthcare accessibility in the digital age.
- 11 August 2024
- Published by Springer Nature in Research Square
Open AccessComparative Analysis of Large Language Models against the NHS 111 Online Triaging for Emergency Ophthalmology
Background This study presents a comprehensive evaluation of the performance of various language models in generating responses for ophthalmology emergencies and compares their accuracy with the established NHS 111 online Triage system.Methods We included 21 ophthalmology related emergency scenario questions from the 111 triaging algorithm. These questions were based on four different ophthalmology emergency themes as laid out in the NHS 111 algorithm. The responses generated from NHS 111 online, were compared to the different LLM-chatbots responses. We included a range of models including ChatGPT-3.5, Google Bard, Bing Chat, and ChatGPT-4.0. The accuracy of each LLM-chatbot response was compared against the NHS 111 Triage using a two prompt strategy. Answers were graded separately by two different authors as following: −2 graded as “Very poor”, -1 as “Poor”, 0 as “No response”, 1 as “Good”, 2 as “Very good” and 3 graded as “Excellent”.Results Overall score of ≥ 1 graded as “Good” or better was achieved by 93% of responses of all LLMs. This refers to at least part of the answer having correct information and partially matching NHS 111 response, as well as the absence of any wrong information or advice which is potentially harmful to the patient’s health.Conclusions The high accuracy and safety observed in LLM responses support their potential as effective tools for providing timely information and guidance to patients. While further research is warranted to validate these findings in clinical practice, LLMs hold promise in enhancing patient care and healthcare accessibility in the digital age.
- 19 July 2024
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 33 (11) , 888-893
A Survey of Current Gonioscopy Practice in the United Kingdom
Précis: This survey highlights a deficiency in gonioscopy practices across the UK, particularly in the utilization of indentation gonioscopy and training of junior ophthalmologists. Recommendations include standardizing practice and enhancing training opportunities to improve patient care. Objective: Gonioscopy is an important general skill learned and practiced by all grades of ophthalmologists. The aim of this study is to discover the general attitude, perception, and practice of gonioscopy among ophthalmologists in the UK. Materials and Methods: A National gonioscopy survey was carried out by utilizing an anonymous electronic questionnaire of 18 questions. The questionnaire was electronically distributed online, using the survey tool, Microsoft 2016 “MS Forms” to all grades of ophthalmologists in the UK. Results: A total of 146 responses were analyzed. Overall, 89% of the participants felt “comfortable in performing slit lamp gonioscopy,” but only 38% of junior trainees (ophthalmic specialist trainees years 1–3) felt comfortable in gonioscopy. Only 13% of the junior trainees felt they had adequate training in performing gonioscopy compared with 68% of the total respondents. Surprisingly, the majority of consultants (58%) did not “strongly agree” to be confident in assessing the angle and its configuration on gonioscopy. The most commonly used gonioscopic lens in this survey was the Zeiss four-mirror gonio lens, but only 38% of participants performed indentation gonioscopy routinely. The majority of the participants utilized the modified Shaffer’s classification for gonioscopy. Fewer than expected numbers performed gonioscopy routinely for new patients with glaucoma. Conclusion: This survey suggests that gonioscopy is not being performed according to the UK national recommendations, and few ophthalmologists perform indentation gonioscopy. Additional gonioscopy training in the curriculum may be helpful.
- 19 July 2024
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 33 (11) , 888-893
A Survey of Current Gonioscopy Practice in the United Kingdom
Précis: This survey highlights a deficiency in gonioscopy practices across the UK, particularly in the utilization of indentation gonioscopy and training of junior ophthalmologists. Recommendations include standardizing practice and enhancing training opportunities to improve patient care. Objective: Gonioscopy is an important general skill learned and practiced by all grades of ophthalmologists. The aim of this study is to discover the general attitude, perception, and practice of gonioscopy among ophthalmologists in the UK. Materials and Methods: A National gonioscopy survey was carried out by utilizing an anonymous electronic questionnaire of 18 questions. The questionnaire was electronically distributed online, using the survey tool, Microsoft 2016 “MS Forms” to all grades of ophthalmologists in the UK. Results: A total of 146 responses were analyzed. Overall, 89% of the participants felt “comfortable in performing slit lamp gonioscopy,” but only 38% of junior trainees (ophthalmic specialist trainees years 1–3) felt comfortable in gonioscopy. Only 13% of the junior trainees felt they had adequate training in performing gonioscopy compared with 68% of the total respondents. Surprisingly, the majority of consultants (58%) did not “strongly agree” to be confident in assessing the angle and its configuration on gonioscopy. The most commonly used gonioscopic lens in this survey was the Zeiss four-mirror gonio lens, but only 38% of participants performed indentation gonioscopy routinely. The majority of the participants utilized the modified Shaffer’s classification for gonioscopy. Fewer than expected numbers performed gonioscopy routinely for new patients with glaucoma. Conclusion: This survey suggests that gonioscopy is not being performed according to the UK national recommendations, and few ophthalmologists perform indentation gonioscopy. Additional gonioscopy training in the curriculum may be helpful.
- Open Access
- 14 January 2022
- Published by SAGE Publications in Therapeutic Advances in Ophthalmology
- Vol. 14
Aspiration of viscous plug in macular hole surgery: a case series
Macular hole surgery has been revolutionized since the 1990s’ with the advent of pars plana vitrectomy with internal limiting membrane peeling and gas tamponade, which is now extensively practiced and regarded as the gold standard procedure for surgical treatment of macular hole. Here, we report a simple adjunctive maneuver to conventional PPV with ILM peel and gas tamponade. We observed presence of a viscous fluid in the base of the macular hole in our series. In all, 40 eyes of 39 patients consecutively operated on from June 2019 to December 2020 for PPV with ILM peel and gas tamponade, were included in this study. The viscous plug was aspirated passively using a 25 gauge cannula with its tip above the macular hole, approaching only until a fluid-wave was visualized, which resulted in flattening of the fluid cuff area aiding the macular hole closure in a concentric pattern. Macular hole closure and complete success was seen in 39 out of 40 eyes (97.5%) and only 1 failure (2.5%) observed in this series. In our case series, we have observed the presence of a viscous fluid plug in the macular hole. We demonstrated that aspirating this thick fluid from the hole results in the flattening of the cuff of fluid and subsequent closure of the macular hole in a concentric manner in almost all cases in our series. The lack of concurrent control group means we cannot state a definitive effect of the intervention, but it does suggest the utility of a prospective randomized controlled trial.
- 14 January 2022
- Published by SAGE Publications in Therapeutic Advances in Ophthalmology
- Vol. 14
Open AccessAspiration of viscous plug in macular hole surgery: a case series
Macular hole surgery has been revolutionized since the 1990s’ with the advent of pars plana vitrectomy with internal limiting membrane peeling and gas tamponade, which is now extensively practiced and regarded as the gold standard procedure for surgical treatment of macular hole. Here, we report a simple adjunctive maneuver to conventional PPV with ILM peel and gas tamponade. We observed presence of a viscous fluid in the base of the macular hole in our series. In all, 40 eyes of 39 patients consecutively operated on from June 2019 to December 2020 for PPV with ILM peel and gas tamponade, were included in this study. The viscous plug was aspirated passively using a 25 gauge cannula with its tip above the macular hole, approaching only until a fluid-wave was visualized, which resulted in flattening of the fluid cuff area aiding the macular hole closure in a concentric pattern. Macular hole closure and complete success was seen in 39 out of 40 eyes (97.5%) and only 1 failure (2.5%) observed in this series. In our case series, we have observed the presence of a viscous fluid plug in the macular hole. We demonstrated that aspirating this thick fluid from the hole results in the flattening of the cuff of fluid and subsequent closure of the macular hole in a concentric manner in almost all cases in our series. The lack of concurrent control group means we cannot state a definitive effect of the intervention, but it does suggest the utility of a prospective randomized controlled trial.
- 7 January 2021
- Published by Springer Nature in International Ophthalmology
- Vol. 41 (4) , 1309-1316
National survey of intraoperative mitomycin C use during trabeculectomy surgery in the UK
Purpose Mitomycin C is a routinely used antimetabolite which effectively limits the scarring process. Conventionally, the intra-operative technique of MMC delivery during trabeculectomy is the direct application of the soaked sponges. The aim of this study is to evaluate the current practice of delivering MMC during trabeculectomy and to see the practices related to a retained MMC swab during trabeculectomy in the UK. Methods An electronic questionnaire of 8 questions regarding the intraoperative use of MMC during trabeculectomy surgery was emailed to 69 ophthalmologist members of the UK and Eire glaucoma society (UKEGS) through email in July 2019. Results 97.2% of the surveyed glaucoma surgeons said they use MMC during trabeculectomy routinely, while 2.9% said they never use MMC for trabeculectomy. In reply to a question ‘Have you ever had a retained MMC-soaked sponge/fragment of sponge’, 11.76% replied ‘yes’, 88.24% said ‘No’. In response to what technique was employed at the time of retained MMC sponges, all the respondents said they had employed the same technique of ‘multiple individual sponges’. 47.1% surgeons said they use multiple individual sponges on being asked what technique they currently employ for delivering MMC during trabeculectomy surgery, while 14.7% surgeons use multiple sponges linked with a ‘necklace suture’ and 5.9% inject MMC. Conclusion Our survey suggests the intra-operative MMC use in the UK is high and that unintentional MMC-soaked swab retention does occur, albeit rarely. A preference of using the MMC-soaked swabs as a delivery method of MMC is seen in our survey.
- 7 January 2021
- Published by Springer Nature in International Ophthalmology
- Vol. 41 (4) , 1309-1316
National survey of intraoperative mitomycin C use during trabeculectomy surgery in the UK
Purpose Mitomycin C is a routinely used antimetabolite which effectively limits the scarring process. Conventionally, the intra-operative technique of MMC delivery during trabeculectomy is the direct application of the soaked sponges. The aim of this study is to evaluate the current practice of delivering MMC during trabeculectomy and to see the practices related to a retained MMC swab during trabeculectomy in the UK. Methods An electronic questionnaire of 8 questions regarding the intraoperative use of MMC during trabeculectomy surgery was emailed to 69 ophthalmologist members of the UK and Eire glaucoma society (UKEGS) through email in July 2019. Results 97.2% of the surveyed glaucoma surgeons said they use MMC during trabeculectomy routinely, while 2.9% said they never use MMC for trabeculectomy. In reply to a question ‘Have you ever had a retained MMC-soaked sponge/fragment of sponge’, 11.76% replied ‘yes’, 88.24% said ‘No’. In response to what technique was employed at the time of retained MMC sponges, all the respondents said they had employed the same technique of ‘multiple individual sponges’. 47.1% surgeons said they use multiple individual sponges on being asked what technique they currently employ for delivering MMC during trabeculectomy surgery, while 14.7% surgeons use multiple sponges linked with a ‘necklace suture’ and 5.9% inject MMC. Conclusion Our survey suggests the intra-operative MMC use in the UK is high and that unintentional MMC-soaked swab retention does occur, albeit rarely. A preference of using the MMC-soaked swabs as a delivery method of MMC is seen in our survey.
- Open Access
- 24 October 2019
- Published by Knowledge E DMCC in Journal of Ophthalmic and Vision Research
- Vol. 14 (4) , 518-524
CRB1 Gene Mutation Causing Different Phenotypes of Leber Congenital Amaurosis in Siblings
Purpose: We report a rare case of CRB1 gene mutation in two siblings (sisters) affected with the exact same genetic mutation on both CRB1 genes resulting in varying phenotypes. Case Report: CRB1 gene mutation in this case has resulted in causing varying degrees of Leber congenital amaurosis (LCA) in both sisters with a more severe phenotype in the older sibling causing LCA-8 with retinitis pigmentosa spectrum in both eyes and a milder phenotype causing LCA-8 with less severe rod cone dystrophy in the younger sister. Conclusion: In summary, the mechanisms of varying phenotypes resulting from CRB1 genetic mutation are still not well understood. We concluded that the presence of different phenotypes associated with identical genotypic mutation of a single gene in siblings or in a family is important especially when dealing with retinal dystrophies.
- 24 October 2019
- Published by Knowledge E DMCC in Journal of Ophthalmic and Vision Research
- Vol. 14 (4) , 518-524
Open AccessCRB1 Gene Mutation Causing Different Phenotypes of Leber Congenital Amaurosis in Siblings
Purpose: We report a rare case of CRB1 gene mutation in two siblings (sisters) affected with the exact same genetic mutation on both CRB1 genes resulting in varying phenotypes. Case Report: CRB1 gene mutation in this case has resulted in causing varying degrees of Leber congenital amaurosis (LCA) in both sisters with a more severe phenotype in the older sibling causing LCA-8 with retinitis pigmentosa spectrum in both eyes and a milder phenotype causing LCA-8 with less severe rod cone dystrophy in the younger sister. Conclusion: In summary, the mechanisms of varying phenotypes resulting from CRB1 genetic mutation are still not well understood. We concluded that the presence of different phenotypes associated with identical genotypic mutation of a single gene in siblings or in a family is important especially when dealing with retinal dystrophies.
- Open Access
- 1 January 2018
- Published by SAGE Publications in Therapeutic Advances in Ophthalmology
- Vol. 10
A rare case of bilateral spontaneous indirect caroticocavernous fistula treated previously as a case of conjunctivitis
Carotid cavernous fistula is an abnormal communication between the carotid arterial system and the cavernous sinus. We present an interesting, rare case of bilateral spontaneous ‘Barrow type- C’ fistula treated presumptively as conjunctivitis. A 66 year old patient presented in the eye casualty at North Devon District Hospital in January 2016, referred from her General practitioner complaining of bilateral red eyes. She was found to have large, prominently diffused and engorged scleral blood vessels on both sides along with raised intraocular pressures of 26mm of Hg bilaterally. The patient was diagnosed with an indirect carotic cavernous fistulas bilaterally in view of the clinical and radiology findings. Barrow type - C dural fistulas were reported to be seen bilaterally on radiology findings. Patient was referred for interventional treatment to the closest neurosurgical center where she had four failed attempts of coil embolization after which she was referred to a second neurosurgery center at Bristol where she underwent successful coil catheterization as the treatment for her carotid cavernous fistula. Indirect carotid cavernous fistula most commonly occur spontaneously. Bilateral spontaneous indirect carotid cavernous fistula is a very rare diagnosis and and there are very few cases reported in the literature without an underlying etiology or a known cause like Ehlers -Danlos syndrome or diabetes mellitus. Bilateral spontaneous carotid cavernous fistulas are difficult to diagnose due to mild symptoms and no history of trauma. We conclude that carotid cavernous fistulas are a threat to the vision if left untreated due to delayed diagnosis. We recommend considering bilateral carotid cavernous fistula as a differential diagnosis in patients with an ongoing history of red eyes or those unresponsive to conventional topical treatment for conjunctivitis like symptoms.
- 1 January 2018
- Published by SAGE Publications in Therapeutic Advances in Ophthalmology
- Vol. 10
Open AccessA rare case of bilateral spontaneous indirect caroticocavernous fistula treated previously as a case of conjunctivitis
Carotid cavernous fistula is an abnormal communication between the carotid arterial system and the cavernous sinus. We present an interesting, rare case of bilateral spontaneous ‘Barrow type- C’ fistula treated presumptively as conjunctivitis. A 66 year old patient presented in the eye casualty at North Devon District Hospital in January 2016, referred from her General practitioner complaining of bilateral red eyes. She was found to have large, prominently diffused and engorged scleral blood vessels on both sides along with raised intraocular pressures of 26mm of Hg bilaterally. The patient was diagnosed with an indirect carotic cavernous fistulas bilaterally in view of the clinical and radiology findings. Barrow type - C dural fistulas were reported to be seen bilaterally on radiology findings. Patient was referred for interventional treatment to the closest neurosurgical center where she had four failed attempts of coil embolization after which she was referred to a second neurosurgery center at Bristol where she underwent successful coil catheterization as the treatment for her carotid cavernous fistula. Indirect carotid cavernous fistula most commonly occur spontaneously. Bilateral spontaneous indirect carotid cavernous fistula is a very rare diagnosis and and there are very few cases reported in the literature without an underlying etiology or a known cause like Ehlers -Danlos syndrome or diabetes mellitus. Bilateral spontaneous carotid cavernous fistulas are difficult to diagnose due to mild symptoms and no history of trauma. We conclude that carotid cavernous fistulas are a threat to the vision if left untreated due to delayed diagnosis. We recommend considering bilateral carotid cavernous fistula as a differential diagnosis in patients with an ongoing history of red eyes or those unresponsive to conventional topical treatment for conjunctivitis like symptoms.