Benjamin Lang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Benjamin Lang has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Bergmann
Institute of Electrical Measurement and Sensor Systems, Graz University of Technology, Graz, Austria
10 shared publications Andreas Klug
AVL List GmbH, Nanophysics & Sensor Technologies, Graz, Austria
3 shared publications- Philipp Breitegger
SmaXtec Animal Care GmbH, Sandgasse 36/2, A-8010 Graz, Austria
3 shared publications Simon Schweighart
FH JOANNEUM GmbH, Institute of Aviation, Graz, Austria
3 shared publicationsWolfgang Hassler
FH JOANNEUM GmbH, Institute of Aviation, Graz, Austria
3 shared publicationsAndreas Tramposch
FH JOANNEUM GmbH, Institute of Aviation, Graz, Austria
2 shared publications
Latest Publications
- Open Access
- 14 March 2026
- Published by Copernicus GmbH
Progress on a Flow-Through Integrating Cavity Optical Absorption Spectrometer for In-Situ Cloud Water Condensed Phase Ratio Measurement
Accurate in-situ measurement of cloud microphysical properties, such as the water content, is essential in the research and modelling of cloud and precipitation formation, or the prediction of macrophysical properties, e.g., cloud radiative properties.In mixed-phase clouds, where ice crystals coexist with supercooled liquid droplets on different scales and with varying mixing ratio, accurate knowledge of this mixing ratio of cloud liquid water content to ice water content is important, in particular for advancing radar, lidar and satellite retrievals.Based on previously presented results demonstrating the possibility of measuring the mass concentration of liquid water droplet streams in an integrating sphere absorption meter [1][2], we present the progress made and first validation results of a novel optical instrument for bulk in-situ cloud water condensed phase ratio measurement. The proposed instrument features a flow-through type integrating cavity for differential, near-infrared optical absorption measurement. Such cavities, by nature of their light homogenizing property, largely eliminate particle scattering contributions, which typically prohibit simple optical absorption measurement of particles. This promises to allow direct and in-situ determination of the fractions of both condensed phases in mixed-phase clouds via their optical absorption. The current design is limited to drop and particle sizes below 200 µm due to absorption saturation, as determined from Mie calculations for the chosen optical wavelengths. The lower water content detection limit is determined by speckle noise generated by the integrating cavity, which is subject to presented optimization efforts. We also present numerical Monte-Carlo based ray tracing simulations of the integrating cavity geometry for sensitivity and signal-to-noise ratio optimization.[1] Grafl, M., Bergmann, A., & Lang, B. (2021). Validation of Integrating Cavity Absorption Spectroscopy for Cloud and Aerosol Mass Concentration Measurement: 39th Annual Meeting of the American Association for Aerosol Research. 153.[2] Lang, B.,, Bergmann, A. (2024). Flow-Through Integrating Cavity Optical Absorption Spectrometer for In-Situ Cloud Water Condensed Phase Composition Measurement: Design Constraints and Initial Validation. 42nd Annual Meeting of the American Association for Aerosol Research.
- 14 March 2026
- Published by Copernicus GmbH
Open AccessProgress on a Flow-Through Integrating Cavity Optical Absorption Spectrometer for In-Situ Cloud Water Condensed Phase Ratio Measurement
Accurate in-situ measurement of cloud microphysical properties, such as the water content, is essential in the research and modelling of cloud and precipitation formation, or the prediction of macrophysical properties, e.g., cloud radiative properties.In mixed-phase clouds, where ice crystals coexist with supercooled liquid droplets on different scales and with varying mixing ratio, accurate knowledge of this mixing ratio of cloud liquid water content to ice water content is important, in particular for advancing radar, lidar and satellite retrievals.Based on previously presented results demonstrating the possibility of measuring the mass concentration of liquid water droplet streams in an integrating sphere absorption meter [1][2], we present the progress made and first validation results of a novel optical instrument for bulk in-situ cloud water condensed phase ratio measurement. The proposed instrument features a flow-through type integrating cavity for differential, near-infrared optical absorption measurement. Such cavities, by nature of their light homogenizing property, largely eliminate particle scattering contributions, which typically prohibit simple optical absorption measurement of particles. This promises to allow direct and in-situ determination of the fractions of both condensed phases in mixed-phase clouds via their optical absorption. The current design is limited to drop and particle sizes below 200 µm due to absorption saturation, as determined from Mie calculations for the chosen optical wavelengths. The lower water content detection limit is determined by speckle noise generated by the integrating cavity, which is subject to presented optimization efforts. We also present numerical Monte-Carlo based ray tracing simulations of the integrating cavity geometry for sensitivity and signal-to-noise ratio optimization.[1] Grafl, M., Bergmann, A., & Lang, B. (2021). Validation of Integrating Cavity Absorption Spectroscopy for Cloud and Aerosol Mass Concentration Measurement: 39th Annual Meeting of the American Association for Aerosol Research. 153.[2] Lang, B.,, Bergmann, A. (2024). Flow-Through Integrating Cavity Optical Absorption Spectrometer for In-Situ Cloud Water Condensed Phase Composition Measurement: Design Constraints and Initial Validation. 42nd Annual Meeting of the American Association for Aerosol Research.
- Open Access
- 30 July 2025
- Published by Elsevier in Results in Engineering
- Vol. 27
Steam penetration in long, narrow channels during steam sterilization: A combined study using wavelength modulation spectroscopy and CFD
- 30 July 2025
- Published by Elsevier in Results in Engineering
- Vol. 27
Open AccessSteam penetration in long, narrow channels during steam sterilization: A combined study using wavelength modulation spectroscopy and CFD
- Open Access
- 16 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (13) , 24257-24264
Collinear Photothermal Gas Sensing With a Custom-Made Dichroic and Fiber-Coupled Fabry-Pérot Etalon
Here, we present the implementation of a compact, collinear photothermal interferometry configuration for gas sensing based on a custom-made dichroic and fiber-coupled Fabry-P´erot etalon. By overcoming the design obstacles imposed by such a configuration, advantage of the strong signal enhancement due to the larger overlap of the pump and probe beam volumes was taken. A competitive NNEA of 4.2 × 10−7 cm−1W/ √ Hz and a limit of detection of 38.8 ppmv were achieved. Additionally, the more compact architecture of the sensing unit allows for further miniaturization of photothermal gas sensors. The proposed solution has been fabricated and tested, showing great promise for highly sensitive, selective and miniaturized gas sensors.
- 16 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (13) , 24257-24264
Open AccessCollinear Photothermal Gas Sensing With a Custom-Made Dichroic and Fiber-Coupled Fabry-Pérot Etalon
Here, we present the implementation of a compact, collinear photothermal interferometry configuration for gas sensing based on a custom-made dichroic and fiber-coupled Fabry-P´erot etalon. By overcoming the design obstacles imposed by such a configuration, advantage of the strong signal enhancement due to the larger overlap of the pump and probe beam volumes was taken. A competitive NNEA of 4.2 × 10−7 cm−1W/ √ Hz and a limit of detection of 38.8 ppmv were achieved. Additionally, the more compact architecture of the sensing unit allows for further miniaturization of photothermal gas sensors. The proposed solution has been fabricated and tested, showing great promise for highly sensitive, selective and miniaturized gas sensors.
- Open Access
- 3 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (12) , 19125-19135
Gas Sensing System Based on an All-Fiber Photothermal Microcell
This paper presents an all-fiber, miniature Fabry-Perot gas sensor based on photothermal absorption spectroscopy with a custom-made and cost-efficient interrogation system. The sensing gas microcell has a diameter of 125 μm, a length of 1 mm, and allows for free gas exchange within the optical resonator through micromachined slits. High light intensity and confinement is ensured by delivering the excitation light directly into the gas microcell through a lead-in single-mode fiber. This enhances the photothermal effect and provides a short system response time. The interrogation system utilizes the modulation of an excitation laser diode with a fixed frequency while locking the probe laser onto the gas microcell’s quadrature point and observing the variations of the reflected optical power. To show the potential of the proposed system, nitrogen dioxide was measured in dry air. Thereby, a limit of detection of 20 ppm could be achieved for 10 seconds’ integration time. Furthermore, the small dimensions of the sensor allow for improved dynamic performance with photothermal modulation frequencies as high as 7 kHz.
- 3 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (12) , 19125-19135
Open AccessGas Sensing System Based on an All-Fiber Photothermal Microcell
This paper presents an all-fiber, miniature Fabry-Perot gas sensor based on photothermal absorption spectroscopy with a custom-made and cost-efficient interrogation system. The sensing gas microcell has a diameter of 125 μm, a length of 1 mm, and allows for free gas exchange within the optical resonator through micromachined slits. High light intensity and confinement is ensured by delivering the excitation light directly into the gas microcell through a lead-in single-mode fiber. This enhances the photothermal effect and provides a short system response time. The interrogation system utilizes the modulation of an excitation laser diode with a fixed frequency while locking the probe laser onto the gas microcell’s quadrature point and observing the variations of the reflected optical power. To show the potential of the proposed system, nitrogen dioxide was measured in dry air. Thereby, a limit of detection of 20 ppm could be achieved for 10 seconds’ integration time. Furthermore, the small dimensions of the sensor allow for improved dynamic performance with photothermal modulation frequencies as high as 7 kHz.
- Open Access
- 1 March 2024
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 135 (9)
Optimization of the optical path length amplitude for interferometric photothermal gas and aerosol sensing considering advection: A theoretical study
Photothermal spectroscopy, and more specifically photothermal interferometry (PTI), is a highly sensitive technique for measuring gas and aerosol concentrations. Numerous implementations of different PTI configurations have demonstrated the versatility of the technique. This theoretical study presents a comprehensive analysis and an optimization of the PTI optical path length (OPL) amplitude using characteristic times. We investigate how the OPL amplitude depends on the dimensions and orientations of the interferometer laser beam and the continuous-wave excitation laser beam. This analysis quantifies the impact of advection on the OPL amplitude based on the relative orientation of the two laser beams and the gas flow direction. It is analytically shown that the possibilities for photothermal OPL amplitude optimization are limited when thermal diffusion is dominant. Theoretically, advection has the potential to double or cancel the OPL amplitude, depending on the specific configurations. In summary, we provide an in-depth understanding of the design and parameter considerations required when tailoring and optimizing a PTI sensor for different fields of applications.
- 1 March 2024
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 135 (9)
Open AccessOptimization of the optical path length amplitude for interferometric photothermal gas and aerosol sensing considering advection: A theoretical study
Photothermal spectroscopy, and more specifically photothermal interferometry (PTI), is a highly sensitive technique for measuring gas and aerosol concentrations. Numerous implementations of different PTI configurations have demonstrated the versatility of the technique. This theoretical study presents a comprehensive analysis and an optimization of the PTI optical path length (OPL) amplitude using characteristic times. We investigate how the OPL amplitude depends on the dimensions and orientations of the interferometer laser beam and the continuous-wave excitation laser beam. This analysis quantifies the impact of advection on the OPL amplitude based on the relative orientation of the two laser beams and the gas flow direction. It is analytically shown that the possibilities for photothermal OPL amplitude optimization are limited when thermal diffusion is dominant. Theoretically, advection has the potential to double or cancel the OPL amplitude, depending on the specific configurations. In summary, we provide an in-depth understanding of the design and parameter considerations required when tailoring and optimizing a PTI sensor for different fields of applications.
- Open Access
Flow-Enhanced Photothermal Spectroscopy
Photothermal spectroscopy (PTS) is a promising sensing technique for the measurement of gases and aerosols. PTS systems using a Fabry–Pérot interferometer (FPI) are considered particularly promising owing to their robustness and potential for miniaturization. However, limited information is available on viable procedures for signal improvement through parameter tuning. In our work, we use an FPI-based PTS configuration, in which the excitation laser irradiates the target collinearly to the flowing gas. We demonstrate that the generated thermal wave, and thus the signal intensity, is significantly affected by the ratio between excitation modulation frequency and gas flow velocity towards another. We provide an analytical model that predicts the signal intensity with particular considerations of these two parameter settings and validate the findings experimentally. The results reveal the existence of an optimal working regime, depending on the modulation frequency and flow velocity.
Open AccessFlow-Enhanced Photothermal Spectroscopy
Photothermal spectroscopy (PTS) is a promising sensing technique for the measurement of gases and aerosols. PTS systems using a Fabry–Pérot interferometer (FPI) are considered particularly promising owing to their robustness and potential for miniaturization. However, limited information is available on viable procedures for signal improvement through parameter tuning. In our work, we use an FPI-based PTS configuration, in which the excitation laser irradiates the target collinearly to the flowing gas. We demonstrate that the generated thermal wave, and thus the signal intensity, is significantly affected by the ratio between excitation modulation frequency and gas flow velocity towards another. We provide an analytical model that predicts the signal intensity with particular considerations of these two parameter settings and validate the findings experimentally. The results reveal the existence of an optimal working regime, depending on the modulation frequency and flow velocity.
- Open Access
- 31 March 2021
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 14 (3) , 2477-2500
Photoacoustic hygrometer for icing wind tunnel water content measurement: design, analysis, and intercomparison
This work describes the latest design, calibration and application of a near-infrared laser diode-based photoacoustic (PA) hygrometer developed for total water content measurement in simulated atmospheric freezing precipitation and high ice water content conditions with relevance in fundamental icing research, aviation testing, and certification. The single-wavelength and single-pass PA absorption cell is calibrated for molar water vapor fractions with a two-pressure humidity generator integrated into the instrument. Laboratory calibration showed an estimated measurement accuracy better than 3.3 % in the water vapor mole fraction range of 510–12 360 ppm (5 % from 250–21 200 ppm) with a theoretical limit of detection (3σ) of 3.2 ppm. The hygrometer is examined in combination with a basic isokinetic evaporator probe (IKP) and sampling system designed for icing wind tunnel applications, for which a general description of total condensed water content (CWC) measurements and uncertainties are presented. Despite the current limitation of the IKP to a hydrometeor mass flux below 90 , a CWC measurement accuracy better than 20 % is achieved by the instrument above a CWC of 0.14 g m−3 in cold air (−30 ∘C) with suitable background humidity measurement. Results of a comparison to the Cranfield University IKP instrument in freezing drizzle and rain show a CWC agreement of the two instruments within 20 %, which demonstrates the potential of PA hygrometers for water content measurement in atmospheric icing conditions.- 31 March 2021
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 14 (3) , 2477-2500
Open AccessPhotoacoustic hygrometer for icing wind tunnel water content measurement: design, analysis, and intercomparison
This work describes the latest design, calibration and application of a near-infrared laser diode-based photoacoustic (PA) hygrometer developed for total water content measurement in simulated atmospheric freezing precipitation and high ice water content conditions with relevance in fundamental icing research, aviation testing, and certification. The single-wavelength and single-pass PA absorption cell is calibrated for molar water vapor fractions with a two-pressure humidity generator integrated into the instrument. Laboratory calibration showed an estimated measurement accuracy better than 3.3 % in the water vapor mole fraction range of 510–12 360 ppm (5 % from 250–21 200 ppm) with a theoretical limit of detection (3σ) of 3.2 ppm. The hygrometer is examined in combination with a basic isokinetic evaporator probe (IKP) and sampling system designed for icing wind tunnel applications, for which a general description of total condensed water content (CWC) measurements and uncertainties are presented. Despite the current limitation of the IKP to a hydrometeor mass flux below 90 , a CWC measurement accuracy better than 20 % is achieved by the instrument above a CWC of 0.14 g m−3 in cold air (−30 ∘C) with suitable background humidity measurement. Results of a comparison to the Cranfield University IKP instrument in freezing drizzle and rain show a CWC agreement of the two instruments within 20 %, which demonstrates the potential of PA hygrometers for water content measurement in atmospheric icing conditions. - Open Access
- 8 September 2020
- Published by Copernicus GmbH in EGUsphere
- Vol. 2020, 1-33
Photoacoustic hygrometer for icing wind tunnel water content measurement: Design, analysis and intercomparison
This work describes the latest design, calibration and application of a near-infrared laser diode-based photoacoustic (PA) hygrometer, developed for total water content measurement in simulated atmospheric freezing precipitation and high ice water content conditions with relevance in fundamental icing research, as well as aviation testing and certification. The single-wavelength and single-pass PA absorption cell is calibrated for molar water vapor fractions with a two-pressure humidity generator integrated into the instrument. Laboratory calibration showed an estimated measurement accuracy better than 3.3 % in the water vapor mole fraction range of 510–12,360 ppm (5 % from 250–21,200 ppm) with a theoretical limit of detection (3 sigma) of 3.2 ppm. The hygrometer is examined in combination with a basic isokinetic evaporator probe (IKP) and sampling system designed for icing wind tunnel application, for which a general description of total condensed water content (CWC) measurement and uncertainties are presented. Despite the current limitation of the IKP to a hydrometeor mass flux below 90 g m−2 s−1, a CWC measurement accuracy better than 20 % is achieved by the instrument above a CWC of 0.14 g m−3 in cold air (−30 °C) with suitable background humidity measurement. Results of a comparison to the Cranfield University IKP instrument in freezing drizzle and rain show a CWC agreement of the two instruments within 20 %, which demonstrates the potential of PA hygrometers for water content measurement in atmospheric icing conditions.
- 8 September 2020
- Published by Copernicus GmbH in EGUsphere
- Vol. 2020, 1-33
Open AccessPhotoacoustic hygrometer for icing wind tunnel water content measurement: Design, analysis and intercomparison
This work describes the latest design, calibration and application of a near-infrared laser diode-based photoacoustic (PA) hygrometer, developed for total water content measurement in simulated atmospheric freezing precipitation and high ice water content conditions with relevance in fundamental icing research, as well as aviation testing and certification. The single-wavelength and single-pass PA absorption cell is calibrated for molar water vapor fractions with a two-pressure humidity generator integrated into the instrument. Laboratory calibration showed an estimated measurement accuracy better than 3.3 % in the water vapor mole fraction range of 510–12,360 ppm (5 % from 250–21,200 ppm) with a theoretical limit of detection (3 sigma) of 3.2 ppm. The hygrometer is examined in combination with a basic isokinetic evaporator probe (IKP) and sampling system designed for icing wind tunnel application, for which a general description of total condensed water content (CWC) measurement and uncertainties are presented. Despite the current limitation of the IKP to a hydrometeor mass flux below 90 g m−2 s−1, a CWC measurement accuracy better than 20 % is achieved by the instrument above a CWC of 0.14 g m−3 in cold air (−30 °C) with suitable background humidity measurement. Results of a comparison to the Cranfield University IKP instrument in freezing drizzle and rain show a CWC agreement of the two instruments within 20 %, which demonstrates the potential of PA hygrometers for water content measurement in atmospheric icing conditions.
- Open Access
- 16 March 2020
- Published by Springer Nature in Applied Physics B
- Vol. 126 (4) , 1-18
Molecular relaxation effects on vibrational water vapor photoacoustic spectroscopy in air
Photoacoustic spectroscopy is a highly sensitive technique, well suited for and used in applications targeting the accurate measurement of water vapor in a wide range of concentrations. This work demonstrates the nonlinear photoacoustic response obtained for water vapor in air at typical atmospheric concentration levels, which is a result of the resonant vibrational coupling of water and oxygen. Relevant processes in the relaxation path of water in a mixture with air, excited with near-infrared radiation, are identified and a physical model for the acoustic signal measured with a resonant photoacoustic cell is presented. The model is valid for modulation frequencies typical for conventional and quartz-enhanced photoacoustic spectroscopy and provides a simplified means of calibration for photoacoustic water vapor sensors. Estimated values for comprised model coefficients are evaluated from photoacoustic measurements of water vapor in synthetic air. Furthermore, it is shown experimentally that the process of vibrational excitation of nitrogen is of negligible importance in the relaxation path of water vapor and thus insignificant in the photoacoustic heat production in atmospheric measurement environments.
- 16 March 2020
- Published by Springer Nature in Applied Physics B
- Vol. 126 (4) , 1-18
Open AccessMolecular relaxation effects on vibrational water vapor photoacoustic spectroscopy in air
Photoacoustic spectroscopy is a highly sensitive technique, well suited for and used in applications targeting the accurate measurement of water vapor in a wide range of concentrations. This work demonstrates the nonlinear photoacoustic response obtained for water vapor in air at typical atmospheric concentration levels, which is a result of the resonant vibrational coupling of water and oxygen. Relevant processes in the relaxation path of water in a mixture with air, excited with near-infrared radiation, are identified and a physical model for the acoustic signal measured with a resonant photoacoustic cell is presented. The model is valid for modulation frequencies typical for conventional and quartz-enhanced photoacoustic spectroscopy and provides a simplified means of calibration for photoacoustic water vapor sensors. Estimated values for comprised model coefficients are evaluated from photoacoustic measurements of water vapor in synthetic air. Furthermore, it is shown experimentally that the process of vibrational excitation of nitrogen is of negligible importance in the relaxation path of water vapor and thus insignificant in the photoacoustic heat production in atmospheric measurement environments.
- Open Access
Intensity Modulated Photothermal Measurements of NO2 with a Compact Fiber-Coupled Fabry–Pérot Interferometer
Sensors for the reliable measurement of nitrogen dioxide concentrations are of high interest due the adverse health effects of this pollutant. This work employs photothermal spectroscopy to measure nitrogen dioxide concentrations at the parts per billion level. Absorption induced temperature changes are detected by means of a fiber-coupled Fabry–Pérot interferometer. The small size of the interferometer enables small detection volumes, paving the way for miniaturized sensing concepts as well as fast response times, demonstrated down to 3 s. A normalized noise equivalent absorption of cm−1W/ is achieved. Additionally, due to the rigid structure of the interferometer, the sensitivity to mechanical vibrations is shown to be minor.Open AccessIntensity Modulated Photothermal Measurements of NO2 with a Compact Fiber-Coupled Fabry–Pérot Interferometer
Sensors for the reliable measurement of nitrogen dioxide concentrations are of high interest due the adverse health effects of this pollutant. This work employs photothermal spectroscopy to measure nitrogen dioxide concentrations at the parts per billion level. Absorption induced temperature changes are detected by means of a fiber-coupled Fabry–Pérot interferometer. The small size of the interferometer enables small detection volumes, paving the way for miniaturized sensing concepts as well as fast response times, demonstrated down to 3 s. A normalized noise equivalent absorption of cm−1W/ is achieved. Additionally, due to the rigid structure of the interferometer, the sensitivity to mechanical vibrations is shown to be minor.