Zhen Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zhen Zhu has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Fujun Ma
College of Electrical and Information Engineering, Hunan University, Changsha, China
7 shared publications - Zhixing He
College of Electrical and Information Engineering, Hunan University, Changsha, China
4 shared publications Gaoxiang Li
2 shared publications- Gaoxiang Li
Guangxi University
2 shared publications - Lei Wang
Beijing Jiaotong University
2 shared publications Lingfeng Deng
2 shared publications
Latest Publications
- 1 April 2026
- Published by Springer Nature
- p. 533-545
Fast Frequency Response Control and Transient Stability Analysis Method for Energy Routers with Renewable Energy Access
- 1 April 2026
- Published by Springer Nature
- p. 533-545
Fast Frequency Response Control and Transient Stability Analysis Method for Energy Routers with Renewable Energy Access
- 1 April 2026
- Published by Springer Nature
- p. 302-312
Research on Fast Response Control Method of Power Conversion System Based on Coupled VOC
- 1 April 2026
- Published by Springer Nature
- p. 302-312
Research on Fast Response Control Method of Power Conversion System Based on Coupled VOC
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (9) , 10444-10454
Dual Natural Switching Surface Control for Multilevel Noninverting Buck-Boost Converter With Pulsed Power Loads
Pulsed power loads (PPLs) have the requirements of fast dynamic and high-power ratings, which may cause periodic power oscillations in traditional dc microgrid systems. Therefore, an improved dual natural switching surface (DNSS) boundary control law is proposed for multilevel noninverting buck-boost converter to dynamically synchronize the periodic power of PPLs within the minimum switching cycle by deriving and tracking the controlled trajectories. First, the variable structure model is established to derive the natural switching surfaces. Then, a graphical characteristic analysis of the transient switching trajectory is presented for the derivation of DNSSs, which can be divided into the primary and the secondary switching. Also, the control strategy based on DNSS is proposed. Due to the super dynamic performance of boundary control and the load characteristic of PPLs, the inductor current may be over the maximum permissible current, and online over-current protection is designed to achieve fast dynamic performance by limiting the inductor current. Finally, simulations and experiments are given to verify the proposed control law. The results show the proposed method has great dynamic performance for PPLs.
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (9) , 10444-10454
Dual Natural Switching Surface Control for Multilevel Noninverting Buck-Boost Converter With Pulsed Power Loads
Pulsed power loads (PPLs) have the requirements of fast dynamic and high-power ratings, which may cause periodic power oscillations in traditional dc microgrid systems. Therefore, an improved dual natural switching surface (DNSS) boundary control law is proposed for multilevel noninverting buck-boost converter to dynamically synchronize the periodic power of PPLs within the minimum switching cycle by deriving and tracking the controlled trajectories. First, the variable structure model is established to derive the natural switching surfaces. Then, a graphical characteristic analysis of the transient switching trajectory is presented for the derivation of DNSSs, which can be divided into the primary and the secondary switching. Also, the control strategy based on DNSS is proposed. Due to the super dynamic performance of boundary control and the load characteristic of PPLs, the inductor current may be over the maximum permissible current, and online over-current protection is designed to achieve fast dynamic performance by limiting the inductor current. Finally, simulations and experiments are given to verify the proposed control law. The results show the proposed method has great dynamic performance for PPLs.
- 9 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (12) , 14409-14419
Multimode Smooth Transition Technique for Three-Level Cascaded Noninverting Buck–Boost DC–DC Converter
In this article, a new three-level cascaded noninverting buck-boost converter (TL-CNIBB) is proposed, which has a superior adaptation for a wide-range voltage input of renewable energy access. Firstly, the operation principle is analyzed for TL-CNIBB and it is mainly divided into four modes, namely buck mode with the voltage ratio below or above 0.5, boost mode with the voltage ratio below or above 2. Due to multilevel and multimode features, several fundamental issues are required to be settled, such as a dead zone between buck mode and boost mode, capacitor voltage unbalance on both sides, and subharmonics at the edge of modes. For dead zone and capacitor voltage balance problems, a systematic control strategy is proposed, and four kinds of smooth transition technologies are proposed to deal with different cases. Furthermore, to avoid the chattering and subharmonics at the edge of modes, a modified hysteretic transition method is proposed. Finally, a prototype of TL-CNIBB system is constructed, and the experiments are carried out to verify the performance of the proposed system with high viability and flexibility.
- 9 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (12) , 14409-14419
Multimode Smooth Transition Technique for Three-Level Cascaded Noninverting Buck–Boost DC–DC Converter
In this article, a new three-level cascaded noninverting buck-boost converter (TL-CNIBB) is proposed, which has a superior adaptation for a wide-range voltage input of renewable energy access. Firstly, the operation principle is analyzed for TL-CNIBB and it is mainly divided into four modes, namely buck mode with the voltage ratio below or above 0.5, boost mode with the voltage ratio below or above 2. Due to multilevel and multimode features, several fundamental issues are required to be settled, such as a dead zone between buck mode and boost mode, capacitor voltage unbalance on both sides, and subharmonics at the edge of modes. For dead zone and capacitor voltage balance problems, a systematic control strategy is proposed, and four kinds of smooth transition technologies are proposed to deal with different cases. Furthermore, to avoid the chattering and subharmonics at the edge of modes, a modified hysteretic transition method is proposed. Finally, a prototype of TL-CNIBB system is constructed, and the experiments are carried out to verify the performance of the proposed system with high viability and flexibility.
- Open Access
- 27 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 68 (7) , 5788-5798
A DC Hybrid Active Power Filter and Its Nonlinear Unified Controller Using Feedback Linearization
In the current power system, the conversion between dc and ac is widely existing and the dc-side harmonic problem is prominent. To suppress the second-harmonic current at the dc side of a single-stage single-phase inverter, a dc hybrid active power filter (DC-HAPF) structure is presented, which composes of a bidirectional dc-dc circuit-based active power filter (APF) and a CL passive filter. In this article, the CL passive filter is used to mitigate the high-frequency harmonics and the APF is applied to compensate the low-frequency harmonic current. Meanwhile, the influence of the filter parameters on the harmonic suppression is analyzed based on the average switching model. In addition, for the control of the DC-HAPF, a nonlinear unified controller via feedback linearization is proposed, where the voltage and current dual-loop control is converted to a single-loop control of energy. By analyzing the control system stability and DC-HAPF's performance, appropriate control parameters are selected. To verify the feasibility of the proposed topology and control strategy, a 500-W single-stage single-phase inverter with the DC-HAPF is built and a good performance of the dc-side harmonic suppression has been achieved.
- 27 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 68 (7) , 5788-5798
Open AccessA DC Hybrid Active Power Filter and Its Nonlinear Unified Controller Using Feedback Linearization
In the current power system, the conversion between dc and ac is widely existing and the dc-side harmonic problem is prominent. To suppress the second-harmonic current at the dc side of a single-stage single-phase inverter, a dc hybrid active power filter (DC-HAPF) structure is presented, which composes of a bidirectional dc-dc circuit-based active power filter (APF) and a CL passive filter. In this article, the CL passive filter is used to mitigate the high-frequency harmonics and the APF is applied to compensate the low-frequency harmonic current. Meanwhile, the influence of the filter parameters on the harmonic suppression is analyzed based on the average switching model. In addition, for the control of the DC-HAPF, a nonlinear unified controller via feedback linearization is proposed, where the voltage and current dual-loop control is converted to a single-loop control of energy. By analyzing the control system stability and DC-HAPF's performance, appropriate control parameters are selected. To verify the feasibility of the proposed topology and control strategy, a 500-W single-stage single-phase inverter with the DC-HAPF is built and a good performance of the dc-side harmonic suppression has been achieved.
- 3 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 35 (10) , 11096-11107
Analysis and Mitigation of Subsynchronous Resonance in Series-Compensated Grid-Connected System Controlled by a Virtual Synchronous Generator
Analogizing the sub-synchronous resonance (SSR) phenomenon of the series-compensated grid-connected system based on synchronous generator, the virtual synchronous generator (VSG) also has the low-frequency oscillation problem owing to the impedance interaction between VSG and series-compensated network. Stability of the series-compensated grid-connected system controlled by VSG is analyzed by the impedance-based Nyquist stability criterion. Due to the inductive impedance of VSG, VSG is easy to couple with the series-compensated network in the low-frequency areas, which can lead to the SSR. With the increase of the series compensation level, the stability of VSG becomes worse and the induced oscillation frequency becomes higher. Therefore, a mod-ulation signal feedforward active damping control strategy with time delay compensation is proposed to suppress this SSR, which directly feeds the active-damping control signal to the PWM modulator for reshaping the output impedance of VSG from the inductance to the resistance-inductance. Moreover, a value range of virtual resistance is given with considering the influence on the regular operation of VSG. Finally, simulation and experimental results verify the correctness of the SSR analysis and the feasibility of the proposed active-damping control strategy.
- 3 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 35 (10) , 11096-11107
Analysis and Mitigation of Subsynchronous Resonance in Series-Compensated Grid-Connected System Controlled by a Virtual Synchronous Generator
Analogizing the sub-synchronous resonance (SSR) phenomenon of the series-compensated grid-connected system based on synchronous generator, the virtual synchronous generator (VSG) also has the low-frequency oscillation problem owing to the impedance interaction between VSG and series-compensated network. Stability of the series-compensated grid-connected system controlled by VSG is analyzed by the impedance-based Nyquist stability criterion. Due to the inductive impedance of VSG, VSG is easy to couple with the series-compensated network in the low-frequency areas, which can lead to the SSR. With the increase of the series compensation level, the stability of VSG becomes worse and the induced oscillation frequency becomes higher. Therefore, a mod-ulation signal feedforward active damping control strategy with time delay compensation is proposed to suppress this SSR, which directly feeds the active-damping control signal to the PWM modulator for reshaping the output impedance of VSG from the inductance to the resistance-inductance. Moreover, a value range of virtual resistance is given with considering the influence on the regular operation of VSG. Finally, simulation and experimental results verify the correctness of the SSR analysis and the feasibility of the proposed active-damping control strategy.
- 12 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 35 (6) , 6572-6585
Parameter Identification and Lyapunov Function Based Adaptive Switched Control for Underwater Electroacoustic Transduction System
- 12 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 35 (6) , 6572-6585
Parameter Identification and Lyapunov Function Based Adaptive Switched Control for Underwater Electroacoustic Transduction System
- 13 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 8 (2) , 1405-1418
Multiport Railway Power Conditioner and Its Management Control Strategy With Renewable Energy Access
- 13 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 8 (2) , 1405-1418
Multiport Railway Power Conditioner and Its Management Control Strategy With Renewable Energy Access
- 20 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (9) , 8574-8587
Operation Analysis and a Game Theoretic Approach to Dynamic Hybrid Compensator for the V/v Traction System
Due to the train load stochastic jumps, negative sequence currents (NSCs) are unpredictably brought into power grid, which may attack the power system and damage vital devices. To enhance the compensation capacities and improve the power quality, a hybrid scheme is studied in consideration of load stochastic jumps, composed of railway power conditioner, thyristor switched capacitor, and thyristor switched reactor. First, the load discrete jump model and its compensation principle of V/v railway traction system are analyzed to design the hybrid compensators and the capacities. Then, based on the attack-defense game theory, a two-level optimized hybrid controller is proposed to keep the power system affirmative for any train load attacks. In the hybrid system, defender 1 is a discrete strategy that can be early executed by finite logic to minimize the power demands, and defender 2 is a continuous strategy that can be lately controlled by optimal control to minimize NSCs. By this dynamic game, an optimized hybrid compensation can be realized. Finally, simulations and experiments are completed to prove the compensation abilities of the hybrid system and the effectiveness of the hybrid control strategy.
- 20 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (9) , 8574-8587
Operation Analysis and a Game Theoretic Approach to Dynamic Hybrid Compensator for the V/v Traction System
Due to the train load stochastic jumps, negative sequence currents (NSCs) are unpredictably brought into power grid, which may attack the power system and damage vital devices. To enhance the compensation capacities and improve the power quality, a hybrid scheme is studied in consideration of load stochastic jumps, composed of railway power conditioner, thyristor switched capacitor, and thyristor switched reactor. First, the load discrete jump model and its compensation principle of V/v railway traction system are analyzed to design the hybrid compensators and the capacities. Then, based on the attack-defense game theory, a two-level optimized hybrid controller is proposed to keep the power system affirmative for any train load attacks. In the hybrid system, defender 1 is a discrete strategy that can be early executed by finite logic to minimize the power demands, and defender 2 is a continuous strategy that can be lately controlled by optimal control to minimize NSCs. By this dynamic game, an optimized hybrid compensation can be realized. Finally, simulations and experiments are completed to prove the compensation abilities of the hybrid system and the effectiveness of the hybrid control strategy.
- 11 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (2) , 1243-1253
Model Analysis and Sliding Mode Current Controller for Multilevel Railway Power Conditioner Under the V/v Traction System
To manage the power quality of high-speed V/v traction system, a multilevel railway power conditioner (MRPC) is researched. According to the structure and equivalent models of MRPC, basically the MRPC is a symmetrical system, and its four clusters can be divided into two cluster-groups. According to the ac equivalent mathematical models of cluster-groups, it can be considered as the relationships in the αβ frame, but not completely symmetrical, so the positive- and negative-sequence dq models for cluster-groups can be derived. As the fluctuation and randomness of the locomotive loads, a sliding mode control system based on the exponential reaching law in the dq frame is explored to control the cluster ac currents, which can improve the dynamic performance and keep a good tolerance against parameter mismatches. Finally, an experimental prototype is developed, and the results show the feasibility and the robustness of the system.
- 11 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (2) , 1243-1253
Model Analysis and Sliding Mode Current Controller for Multilevel Railway Power Conditioner Under the V/v Traction System
To manage the power quality of high-speed V/v traction system, a multilevel railway power conditioner (MRPC) is researched. According to the structure and equivalent models of MRPC, basically the MRPC is a symmetrical system, and its four clusters can be divided into two cluster-groups. According to the ac equivalent mathematical models of cluster-groups, it can be considered as the relationships in the αβ frame, but not completely symmetrical, so the positive- and negative-sequence dq models for cluster-groups can be derived. As the fluctuation and randomness of the locomotive loads, a sliding mode control system based on the exponential reaching law in the dq frame is explored to control the cluster ac currents, which can improve the dynamic performance and keep a good tolerance against parameter mismatches. Finally, an experimental prototype is developed, and the results show the feasibility and the robustness of the system.