Zhe Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Zhe Zhou has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Chenwen Cheng
School of Electrical Engineering, Southeast University, Nanjing, China
6 shared publications - Chris Mi
Department of Electrical and Computer Engineering, San Diego State University, San Diego, CA 92182, USA
6 shared publications - Chong Zhu
School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
4 shared publications - Fei Lu
Department of Electrical and Computer Engineering, Lehigh University, Bethlehem, PA, USA
4 shared publications - Weiguo Li
State Grid Corporation of China, 154576 Beijing, Beijing China
4 shared publications - Zhanfeng Deng
State Grid Corporation of China, 154576 Beijing, Beijing China
4 shared publications
Latest Publications
- Open Access
- 1 December 2019
- Published by Elsevier in Global Energy Interconnection
- Vol. 2 (6) , 521-530
High-temperature characteristics of SiC module and 100 kW SiC AC-DC converter at a junction temperature of 180 °C
- 1 December 2019
- Published by Elsevier in Global Energy Interconnection
- Vol. 2 (6) , 521-530
Open AccessHigh-temperature characteristics of SiC module and 100 kW SiC AC-DC converter at a junction temperature of 180 °C
- 30 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 8 (4) , 3533-3541
A Multiload Inductive Power Transfer Repeater System With Constant Load Current Characteristics
In this article, an inductive power transfer (IPT) system is designed to power multiple loads with nearly constant load currents using repeater coils. In the proposed IPT repeater system, every two repeater coils are grouped into a repeater unit and the load is connected to the first repeater coil in each repeater unit. It is deduced that the constant load current can be obtained when only considering the coupling coefficients between any two adjacent coils and omitting the coil resistances. Thus, the load power can be regulated independently, which greatly simplifies the power control design. A feasible magnetic structure is designed to meet the requirement that the coupling coefficients between the nonadjacent coils can be omitted. The relationship between the load resistances to achieve equal power distribution when considering coil resistances is derived. The proposed IPT system can be used to power gate drivers of the multiple submodules (SMs) that are connected in series in the modular multilevel converter (MMC). An experimental setup with six loads is constructed where the distance between two adjacent repeater units is 65 mm. The maximum system efficiency is around 60%.
- 30 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 8 (4) , 3533-3541
A Multiload Inductive Power Transfer Repeater System With Constant Load Current Characteristics
In this article, an inductive power transfer (IPT) system is designed to power multiple loads with nearly constant load currents using repeater coils. In the proposed IPT repeater system, every two repeater coils are grouped into a repeater unit and the load is connected to the first repeater coil in each repeater unit. It is deduced that the constant load current can be obtained when only considering the coupling coefficients between any two adjacent coils and omitting the coil resistances. Thus, the load power can be regulated independently, which greatly simplifies the power control design. A feasible magnetic structure is designed to meet the requirement that the coupling coefficients between the nonadjacent coils can be omitted. The relationship between the load resistances to achieve equal power distribution when considering coil resistances is derived. The proposed IPT system can be used to power gate drivers of the multiple submodules (SMs) that are connected in series in the modular multilevel converter (MMC). An experimental setup with six loads is constructed where the distance between two adjacent repeater units is 65 mm. The maximum system efficiency is around 60%.
- 9 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 35 (4) , 3328-3331
A Load-Independent Wireless Power Transfer System With Multiple Constant Voltage Outputs
A novel WPT system is proposed to power the gate drivers in a multilevel converter to achieve a high insulation level. There are two requirements for the proposed WPT system. First, the WPT system should contain multiple outputs, each corresponding to one gate driver. Second, a constant voltage source is needed for each gate driver. For a multi-load WPT system, it is challenging but necessary to realize independent power control of each load. To achieve this goal, the repeater unit consisting of two repeater coils is designed to power a load. Many loads can be powered simultaneously by using multiple repeater units together. The LCC-S compensation topology is adopted for the proposed WPT system. Constant voltage outputs are obtained for all the loads when neglecting the coil's parasitic resistance. An experimental platform with six loads was developed to validate the proposed WPT system.
- 9 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 35 (4) , 3328-3331
A Load-Independent Wireless Power Transfer System With Multiple Constant Voltage Outputs
A novel WPT system is proposed to power the gate drivers in a multilevel converter to achieve a high insulation level. There are two requirements for the proposed WPT system. First, the WPT system should contain multiple outputs, each corresponding to one gate driver. Second, a constant voltage source is needed for each gate driver. For a multi-load WPT system, it is challenging but necessary to realize independent power control of each load. To achieve this goal, the repeater unit consisting of two repeater coils is designed to power a load. Many loads can be powered simultaneously by using multiple repeater units together. The LCC-S compensation topology is adopted for the proposed WPT system. Constant voltage outputs are obtained for all the loads when neglecting the coil's parasitic resistance. An experimental platform with six loads was developed to validate the proposed WPT system.
- 1 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Impact of the Parasitic Resistors in Compensation Inductors on a Multi-stage and Multi-load Wireless Power Transfer System
Multi-stage and multi-load wireless power transfer (MMWPT) system is capable of providing multiple isolated power supplies, which is promising to be utilized to supply driver circuits of high-voltage power converters. This paper analyzes the impact of the parasitic resistors in compensation inductors on an MMWPT system, mainly about the impact on the characteristic of load currents and the system efficiency. A 6-stage and 6-load WPT system employing GaN-based high-frequency inverter is built to verify the analytical results, working at 200kHz.
- 1 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Impact of the Parasitic Resistors in Compensation Inductors on a Multi-stage and Multi-load Wireless Power Transfer System
Multi-stage and multi-load wireless power transfer (MMWPT) system is capable of providing multiple isolated power supplies, which is promising to be utilized to supply driver circuits of high-voltage power converters. This paper analyzes the impact of the parasitic resistors in compensation inductors on an MMWPT system, mainly about the impact on the characteristic of load currents and the system efficiency. A 6-stage and 6-load WPT system employing GaN-based high-frequency inverter is built to verify the analytical results, working at 200kHz.
- 31 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 67 (6) , 4507-4515
A Load-Independent LCC-Compensated Wireless Power Transfer System for Multiple Loads With a Compact Coupler Design
This paper proposes a novel wireless power transfer (WPT) system for multiple loads. Multiple coils are used as power repeaters to enhance the power transfer capability over a long distance and each power repeater corresponds to a load. The LCC compensation method is used for each repeater coil in the system, which ensures load-independent currents flowing through the loads. Thus, flexible power control can be achieved for all the loads without affecting each other. In order to save space, the compensation coil is integrated with the repeater coil to realize a compact design. Bipolar coils are used for both the repeater coil and compensation coil. The undesirable coupling coefficient between the repeater coil and its compensation coil can be eliminated by putting them perpendicularly. The compensation coil is not only used to achieve resonant condition for the system, but also transfers energy to the next repeater coil via the magnetic coupling between them. The operational principle has been explained in detail. An experiment platform with six loads has been built and the experimental results are provided to validate the effectiveness of the proposed WPT repeater system. The maximum efficiency can reach 86.6%.
- 31 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 67 (6) , 4507-4515
A Load-Independent LCC-Compensated Wireless Power Transfer System for Multiple Loads With a Compact Coupler Design
This paper proposes a novel wireless power transfer (WPT) system for multiple loads. Multiple coils are used as power repeaters to enhance the power transfer capability over a long distance and each power repeater corresponds to a load. The LCC compensation method is used for each repeater coil in the system, which ensures load-independent currents flowing through the loads. Thus, flexible power control can be achieved for all the loads without affecting each other. In order to save space, the compensation coil is integrated with the repeater coil to realize a compact design. Bipolar coils are used for both the repeater coil and compensation coil. The undesirable coupling coefficient between the repeater coil and its compensation coil can be eliminated by putting them perpendicularly. The compensation coil is not only used to achieve resonant condition for the system, but also transfers energy to the next repeater coil via the magnetic coupling between them. The operational principle has been explained in detail. An experiment platform with six loads has been built and the experimental results are provided to validate the effectiveness of the proposed WPT repeater system. The maximum efficiency can reach 86.6%.
- 7 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 8 (2) , 1419-1427
A High-Efficiency and Long-Distance Power-Relay System With Equal Power Distribution
This paper proposes a wireless power repeater system for long-distance and multiple-load applications with equal power load at each repeater. Each repeater performs as a power relay that not only receives and transmits power, but also supplies power to its local load. The main contribution of this paper is to provide the design methodology of a distributed power relay system. First, it provides the mathematical model of the power distribution among the power relays, indicating that the inductances and resistances can affect the power distribution. Second, it provides the power transfer capability of a power relay system based on the quality factor and efficiency requirement, indicating the maximum achievable number of power relays in a system. Aiming at practical applications, this paper provides the guideline for the circuit parameter design to achieve equal power distribution. Two typical examples are proposed to realize equal power distribution. The identical Mn and different Rn example is selected for implementation. The coil size is 400mm×400mm, and the eight power relays achieve a transfer distance of 3.2m with total power of 760 W and efficiency of 70%. Experimental results validate that equal power distribution is achieved for the multiple loads across a long distance. Each power relay dissipates about 95W power in its local load with a power variation limited to ±2%.
- 7 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 8 (2) , 1419-1427
A High-Efficiency and Long-Distance Power-Relay System With Equal Power Distribution
This paper proposes a wireless power repeater system for long-distance and multiple-load applications with equal power load at each repeater. Each repeater performs as a power relay that not only receives and transmits power, but also supplies power to its local load. The main contribution of this paper is to provide the design methodology of a distributed power relay system. First, it provides the mathematical model of the power distribution among the power relays, indicating that the inductances and resistances can affect the power distribution. Second, it provides the power transfer capability of a power relay system based on the quality factor and efficiency requirement, indicating the maximum achievable number of power relays in a system. Aiming at practical applications, this paper provides the guideline for the circuit parameter design to achieve equal power distribution. Two typical examples are proposed to realize equal power distribution. The identical Mn and different Rn example is selected for implementation. The coil size is 400mm×400mm, and the eight power relays achieve a transfer distance of 3.2m with total power of 760 W and efficiency of 70%. Experimental results validate that equal power distribution is achieved for the multiple loads across a long distance. Each power relay dissipates about 95W power in its local load with a power variation limited to ±2%.
- 28 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (8) , 7126-7130
A Multi-Load Wireless Power Transfer System With Series-Parallel-Series Compensation
This letter proposes a novel wireless power transfer (WPT) system with repeater coils for multiple loads. Every two repeater coils form a repeater unit where one is used to receive power from its preceding unit and the other one transmits power to the subsequent unit. Each load is connected to a repeater unit and multiple loads can be powered with several repeater units. The two coils in the same repeater unit are both bipolar ones, which are placed perpendicularly so that the magnetic coupling between them can be eliminated. In order to obtain independent power control of all the loads, the series-parallel-series (SPS) compensation method is adopted for each repeater unit. With a proper resonant condition proposed in this paper, the constant load current can be obtained for all the loads when neglecting the coils' parasitic resistances. An experimental setup has be constructed and the effectiveness of the proposed multi-load WPT system is validated by the experimental.
- 28 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (8) , 7126-7130
A Multi-Load Wireless Power Transfer System With Series-Parallel-Series Compensation
This letter proposes a novel wireless power transfer (WPT) system with repeater coils for multiple loads. Every two repeater coils form a repeater unit where one is used to receive power from its preceding unit and the other one transmits power to the subsequent unit. Each load is connected to a repeater unit and multiple loads can be powered with several repeater units. The two coils in the same repeater unit are both bipolar ones, which are placed perpendicularly so that the magnetic coupling between them can be eliminated. In order to obtain independent power control of all the loads, the series-parallel-series (SPS) compensation method is adopted for each repeater unit. With a proper resonant condition proposed in this paper, the constant load current can be obtained for all the loads when neglecting the coils' parasitic resistances. An experimental setup has be constructed and the effectiveness of the proposed multi-load WPT system is validated by the experimental.
- 12 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (9) , 9279-9288
Load-Independent Wireless Power Transfer System for Multiple Loads Over a Long Distance
In this paper, a novel long-distance wireless power transfer (WPT) system using repeater coils is proposed to provide power supplies for the driver circuits in high voltage applications such as flexible alternative current transmission systems (FACTS). Different from most of the existing wireless repeater systems where the load is only connected to the last coil and the repeater coils function solely as power relays, in the proposed system, multiple loads are powered by the repeaters. The repeater coils transfer power not only to the subsequent coils but also to the loads connected to them. Dual coil design is proposed for the repeaters with which load-independent characteristics are obtained with a suitable design of coupling coefficients. As a result, the load power can be easily adjusted without affecting each other. Load current characteristics and system efficiency have been analyzed in detail. The power transfer capability of the proposed system is illustrated for different coil quality factors and coupling coefficients. An experimental setup with 10 loads has been built to validate the effectiveness of the proposed long-distance WPT system. The maximum reachable system efficiency is about 84%.
- 12 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (9) , 9279-9288
Load-Independent Wireless Power Transfer System for Multiple Loads Over a Long Distance
In this paper, a novel long-distance wireless power transfer (WPT) system using repeater coils is proposed to provide power supplies for the driver circuits in high voltage applications such as flexible alternative current transmission systems (FACTS). Different from most of the existing wireless repeater systems where the load is only connected to the last coil and the repeater coils function solely as power relays, in the proposed system, multiple loads are powered by the repeaters. The repeater coils transfer power not only to the subsequent coils but also to the loads connected to them. Dual coil design is proposed for the repeaters with which load-independent characteristics are obtained with a suitable design of coupling coefficients. As a result, the load power can be easily adjusted without affecting each other. Load current characteristics and system efficiency have been analyzed in detail. The power transfer capability of the proposed system is illustrated for different coil quality factors and coupling coefficients. An experimental setup with 10 loads has been built to validate the effectiveness of the proposed long-distance WPT system. The maximum reachable system efficiency is about 84%.
- 1 December 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Switch-mode AC stabilized voltage supply based on PR controller
The dynamic characteristic of traditional controllers is not good enough especially when DC voltage sags or load changes abruptly. Plus, static error would be generated if the input is an AC signal. In this paper, PR controller is used to solve above problems. This article presents the transfer function of PR controller by theoretical analysis, At last, both simulation and experiment achieved the regulatory role by DSP demonstrate that PR controller can eliminate static error and has a good dynamic performance.
- 1 December 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Switch-mode AC stabilized voltage supply based on PR controller
The dynamic characteristic of traditional controllers is not good enough especially when DC voltage sags or load changes abruptly. Plus, static error would be generated if the input is an AC signal. In this paper, PR controller is used to solve above problems. This article presents the transfer function of PR controller by theoretical analysis, At last, both simulation and experiment achieved the regulatory role by DSP demonstrate that PR controller can eliminate static error and has a good dynamic performance.