Elmar Wisotzki
Elmar Wisotzki has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Adam G. Balogh
Materials Science Department, Thin Films Division, Darmstadt University of Technology, 64287 Darmstadt, Germany
1 shared publication- Aligi Foglia
Fraunhofer‐Institut für Windenergiesysteme IWES Merkurstraße 13 30149 Hannover
1 shared publication Danijel Novakovic
Heerema Marine Contractors SE 3 , Vondellaan 47, 2300 PH, Leiden, NL
1 shared publicationGar B. Hoflund
Department of Chemical Engineering, University of Florida, Gainesville, Florida 32611
1 shared publication- Horst Hahn
Institute of Nanotechnology, Karlsruhe Institute of Technology, Karlsruhe, Germany
1 shared publication John T. Wolan
Department of Chemical Engineering, University of Florida, Gainesville, Florida 32611
1 shared publication
Latest Publications
- 1 July 2019
- Published by ASTM International
- p. 506-519
Strain and Acceleration Measurements at Instrumentation Distances to the Pile Head of 0.5 and 1.0 Times the Diameter—Offshore Pile-Monitoring Experience
This paper presents experience gained during offshore pile-monitoring works, namely strain and acceleration measurements, at instrumentation distances from the pile head (impact zone) of 0.5 and 1.0 times the outer pile diameter. For offshore pile installation projects in the German sector of the North Sea, regulations dictate that the axial pile-bearing capacity is confirmed by conducting dynamic pile load tests, which include capacity determination using so-called extended procedures with complete modeling. An important item to adhere to is ensuring a uniform wave front at the measurement location. Therefore, German regulations state that the distance between the transducers and top of the pile shall be at least 1.0 to 1.5 times the pile diameter. For the project discussed in this paper, allowable pile stick-up regulations at a final penetration required the use of a front follower for pile driving. This caused a high risk of shearing off the monitoring provisions at a distance of 1.0 times the diameter while driving to the final penetration. It was therefore decided to equip the piles with monitoring provisions at two levels: an upper level at a distance of only 0.5 times the outer diameter to the pile head and a lower level at a distance of 1.0 times the outer diameter to the pile head. The upper level was equipped with a transducer set consisting of one strain gage and one accelerometer at every 90°. The lower level was equipped with a transducer set at each 180°. This monitoring layout made it possible to compare the measurements of both levels and to assess the differences. The results showed that despite being closer to the pile head than allowed by the regulations, the upper measurement position gave values comparable to those at the lower location.
- 1 July 2019
- Published by ASTM International
- p. 506-519
Strain and Acceleration Measurements at Instrumentation Distances to the Pile Head of 0.5 and 1.0 Times the Diameter—Offshore Pile-Monitoring Experience
This paper presents experience gained during offshore pile-monitoring works, namely strain and acceleration measurements, at instrumentation distances from the pile head (impact zone) of 0.5 and 1.0 times the outer pile diameter. For offshore pile installation projects in the German sector of the North Sea, regulations dictate that the axial pile-bearing capacity is confirmed by conducting dynamic pile load tests, which include capacity determination using so-called extended procedures with complete modeling. An important item to adhere to is ensuring a uniform wave front at the measurement location. Therefore, German regulations state that the distance between the transducers and top of the pile shall be at least 1.0 to 1.5 times the pile diameter. For the project discussed in this paper, allowable pile stick-up regulations at a final penetration required the use of a front follower for pile driving. This caused a high risk of shearing off the monitoring provisions at a distance of 1.0 times the diameter while driving to the final penetration. It was therefore decided to equip the piles with monitoring provisions at two levels: an upper level at a distance of only 0.5 times the outer diameter to the pile head and a lower level at a distance of 1.0 times the outer diameter to the pile head. The upper level was equipped with a transducer set consisting of one strain gage and one accelerometer at every 90°. The lower level was equipped with a transducer set at each 180°. This monitoring layout made it possible to compare the measurements of both levels and to assess the differences. The results showed that despite being closer to the pile head than allowed by the regulations, the upper measurement position gave values comparable to those at the lower location.
- 1 September 2018
- Published by Wiley in geotechnik
- Vol. 41 (3) , 174-185
Evaluation of the group effect for a two-pile group for an offshore platform in sand
- 1 September 2018
- Published by Wiley in geotechnik
- Vol. 41 (3) , 174-185
Evaluation of the group effect for a two-pile group for an offshore platform in sand
- 1 January 1999
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 17 (1) , 14-18
Room-temperature growth of ZrO2 thin films using a novel hyperthermal oxygen-atom source
Thin ZrO2 films have been grown on Si(100) and on glassy carbon substrates using a novel atomic oxygen source in a standard molecular beam epitaxy system. The oxygen source produces a flux of hyperthermal oxygen atoms with an ion/atom-ratio ≪0.001 through electron stimulated desorption from a Ag alloy surface at an operating pressure <10−8 Torr. The films were grown at room temperature and analyzed using Rutherford backscattering spectroscopy, x-ray diffraction (XRD), x-ray photoelectron spectroscopy and transmission electron microscopy (TEM). The results show the successful growth of fully stoichiometric ZrO2 films on nonheated Si(100) and on amorphous glassy carbon substrates at a rate of 0.58 μm/hr. The XRD and TEM investigations indicate the formation of a mixed amorphous/orthorhombic film structure. Based on the film growth rate, the O flux produced by the electron stimulated desorption atom source is estimated to be 8×1014 atoms/cm2 s. This flux value is consistent with other determinations using ion scattering spectroscopy and pyromellitic dianhydride-oxydianiline polyimide (Kapton®) erosion experiments.
- 1 January 1999
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 17 (1) , 14-18
Room-temperature growth of ZrO2 thin films using a novel hyperthermal oxygen-atom source
Thin ZrO2 films have been grown on Si(100) and on glassy carbon substrates using a novel atomic oxygen source in a standard molecular beam epitaxy system. The oxygen source produces a flux of hyperthermal oxygen atoms with an ion/atom-ratio ≪0.001 through electron stimulated desorption from a Ag alloy surface at an operating pressure <10−8 Torr. The films were grown at room temperature and analyzed using Rutherford backscattering spectroscopy, x-ray diffraction (XRD), x-ray photoelectron spectroscopy and transmission electron microscopy (TEM). The results show the successful growth of fully stoichiometric ZrO2 films on nonheated Si(100) and on amorphous glassy carbon substrates at a rate of 0.58 μm/hr. The XRD and TEM investigations indicate the formation of a mixed amorphous/orthorhombic film structure. Based on the film growth rate, the O flux produced by the electron stimulated desorption atom source is estimated to be 8×1014 atoms/cm2 s. This flux value is consistent with other determinations using ion scattering spectroscopy and pyromellitic dianhydride-oxydianiline polyimide (Kapton®) erosion experiments.