MGMichele Giunta

Michele Giunta

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Michele Giunta has a total of 192 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Cross-Spectrum Phase Noise Measurements of Ultrastable Photonic Microwave Oscillators

    by Michele Giunta, Benjamin Rauf, Jaroslaw Sperling, Simon Afrem, Wolfgang Wendler, Alexander Roth, Jonas Kornprobst, Stefan Peschl, Jonas Schulz, Jan Schorer, et al.

    Presently, continuous-wave (CW) lasers stabilized by high- $Q$ Fabry–Pérot optical cavities represent the most stable human-engineered frequency oscillators. For optical signals at 194.4 THz (1.5- $\mu $ m wavelength), cutting-edge systems exhibit fractional frequency instabilities as low as $3 \times 10^{-17}$ over a 1-s averaging time. The lowermost phase noise on microwave (MW) signals can be obtained via phase-coherent optical frequency division (OFD) of this class of optical reference signals. Characterizing this level of phase stability with conventional instrumentation is extremely challenging. Digital electronics-based cross correlation techniques allow the inference of MW signals’ phase noise and amplitude noise via downconversion with independent pairs of internal References, generating two independent measurement channels to be cross-correlated. We present in this article the synthesis of ultrastable MW signals via phase-coherent OFD and their characterization by using a commercial cross correlation-based phase noise analyzer and two auxiliary commercial photonic MW oscillators. These X-band frequency sources exhibit a fractional frequency stability of $\lt\!4\times 10^{-15}$ at 1 s, with phase noise as low as $\lt\!-90$ dBc/Hz at 1 Hz and $\lt\!-150$ dBc/Hz at 1 kHz offset from a 10-GHz carrier. Conventional instruments typically do not permit the reveal of this level of fidelity. We show the use of a digital system and two auxiliary independent and free-running ultrastable sources at >1-MHz offset from the DUT to enable cross correlation measurements within minutes for this level of spectral purity and frequency stability.


  • Top Cited Papers

    Deployment of a transportable Yb optical lattice clock

    by Tobias Bothwell, Wesley Brand, Robert Fasano, Thomas Akin, Joseph Whalen, Tanner Grogan, Yun-Jhih Chen, Marco Pomponio, Takuma Nakamura, Benjamin Rauf, et al.

    We report on the first deployment of a ytterbium (Yb) transportable optical lattice clock (TOLC), commercially shipping the clock 3000 km from Boulder, Colorado, to Washington DC. The system, composed of a rigidly mounted optical reference cavity, an atomic physics package, and an optical frequency comb, fully realizes an independent frequency standard for comparisons in the optical and microwave domains. The shipped Yb TOLC was fully operational within 2 days of arrival, enabling frequency comparison with a rubidium (Rb) fountain at the United States Naval Observatory (USNO). To the best of our knowledge, this represents the first deployment of a fully independent TOLC, including the frequency comb, coherently uniting the optical stability of the Yb TOLC to the microwave output of the Rb fountain.


  • Ultrastable Photonic Microwave Oscillator as Flywheel for Microwave or Optical Atomic Clocks

    by Michele Giunta, Benjamin Rauf, Pu Zou, Simon Afrem, Sebastian Pucher, Cecilia Clivati, Claudio Calosso, Vladislav Gerginov, Juraj Culak, Lorenzo Hernandez, et al.

  • Top Cited Papers
    Open Access

    Long-distance chronometric leveling with a portable optical clock

    by J. Grotti, I. Nosske, S.B. Koller, S. Herbers, H. Denker, L. Timmen, G. Vishnyakova, G. Grosche, T. Waterholter, A. Kuhl, et al.

    We have measured the geopotential difference between two locations separated by 457 km by comparison of two optical lattice clocks via an interferometric fiber link, utilizing the gravitational redshift of the clock transition frequency. The 87Sr clocks have been compared side-by-side before and after one of the clocks was moved to the remote location. The chronometrically measured geopotential difference of 3918.1(2.6)m2s−2 agrees with an independent geodetic determination of 3915.88(0.30)m2s−2. The uncertainty of the chronometric geopotential difference is equivalent to an uncertainty of 27cm in height.


  • Optical-to-microwave phase coherent link at 19th digit accuracy

    by Benjamin Rauf, Ignacio Baldoni, Martin Wolferstetter, Andreas Fricke, Marc Fischer, Michele Giunta, Ronald Holzwarth

    We present a transportable clockwork system capable of porting the optical spectral purity down to the microwave domain at the level of a few parts in 10−19.

  • >1.5 Octave-broad Optical Frequency Comb for Multi-clock Comparisons and Wide-band Spectral Purity Transfer

    by Thomas Lompe, Phillip Woschnik, Kerstin Schlichting, Dario Lago-Rivera, Yuanjie Wu, Tilo Steinmetz, Andreas Fricke, Marc Fischer, Michele Giunta, Ronald Holzwarth

    We present a system composed of an Er:laser-based ultra-low-noise frequency comb seeding a custom-designed photonic-crystal fiber with 2nJ pulse energies. A super-continuum is obtained spanning from 650nm to 2µm. System qualifications will be presented.

  • Rack-Mounted Ultrastable Laser System for Sr Lattice Clock Operation

    by Manuel Brekenfeld, Benjamin Rauf, Sarah Saint-Jalm, Garrett D. Cole, Gar-Wing Truong, Maurice Lessing, Andreas Fricke, Marc Fischer, Michele Giunta, Ronald Holzwarth

    We present a rack-mounted ultra-low-noise laser system for Sr lattice clocks, with spectral purity transfer stability of 4×10−18@1s and 2×10−19@100s. We realize a system stability of 5×10-16@1s, representing state-of-the-art performance for rack-mounted commercial systems.

  • Ultra-stable Laser System for Next-generation Light-pulse Atom Interferometry MAGIS-100

    by Michele Giunta, Manuel Brekenfeld, Maximilian Bradler, Dag Schmidt, Andreas Fricke, Maurice Lessing, Marc Fischer, Joseph Thom, Nils Hempler, Gareth Maker, et al.

    We present a fully phase-locked comb-disciplined-laser system, conceived to operate the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100). Via phase-locking to the comb, four ECDLs and a Ti:Sapphire laser inherit the stability of an ultra-stable laser.

  • Compact and ultrastable photonic microwave oscillator

    by Michele Giunta, Jialiang Yu, Maurice Lessing, Marc Fischer, Matthias Lezius, Xiaopeng Xie, Giorgio Santarelli, Yann Le Coq, Ronald Holzwarth

    Frequency comb synthesized microwaves have been so far realized with tabletop systems, operated in well-controlled environments. Here, we demonstrate state-of-the-art ultrastable microwave synthesis with a compact rack-mountable apparatus. We present absolute phase noise characterization of a 12 GHz signal using an ultrastable laser at ∼ 194 T H z and an Er:fiber comb divider, obtaining − 83 d B c / H z at 1 Hz and < − 166 d B c / H z for offsets greater than 5 kHz. Employing semiconductor coating mirrors for the same type of transportable optical frequency reference, we show that − 105 d B c / H z at 1 Hz is supported by demonstrating a residual noise limit of division and detection process of − 115 d B c / H z at 1 Hz. This level of fidelity paves the way for the deployment of ultrastable photonic microwave oscillators and for operating transportable optical clocks.


  • Complete Laser System for Strontium Lattice Clock Based on Frequency Comb

    by Michele Giunta, Martin Wolferstetter, Nikolai Lilienfein, Simon Holzberger, Sarah Saint-Jalm, Florian Skopnik, Maurice Lessing, Wolfgang Hänsel, Benjamin Sprenger, Marc Fischer, et al.

    We report the development of a complete turn-key 5 × 10-16 ultra-stable laser system for operating neutral strontium atoms for optical lattice clocks or for quantum computing.