Muhammad Raza
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Muhammad Raza has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Oriol Gomis-Bellmunt
Centre d’Innovació Tecnològica en Convertidors Estàtics i Accionaments, Departament d’Enginyeria Elèctrica, Universitat Politècnica de Catalunya, Barcelona, Spain
8 shared publications - Amna Aslam
Sustainable Energies Enterprise, Karachi, Pakistan
2 shared publications Carlos Collados
2 shared publications- Eduardo Prieto-Araujo
CITCEA-UPC, Barcelona, Spain
2 shared publications - Amna Aslam
Department of Electrical Engineering, Bahria University, Karachi Campus, 13, National Stadium Road, Karachi 75260, Pakistan
1 shared publication - Andreas Sumper
Centre d’Innovació Tecnològica en Convertidors Estàtics i Accionaments (CITCEA-UPC), Departament d’Enginyeria Elèctrica, Universitat Politècnica de Catalunya ETS d’Enginyeria Industrial de Barcelona, Avinguda Diagonal, 647, Pl. 2, 08028 Barcelona, Spain
1 shared publication
Latest Publications
- Open Access
- 15 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 124471-124482
Design and Implementation of Active Control Method for Minimizing Circulating Current in MMC-VSC System
Modular Multilevel Converters (MMCs) have emerged as a key technology for large-scale renewable energy integration due to their scalability, fault tolerance, and superior output quality. However, internal circulating currents remain a major barrier to efficiency and long-term reliability. It causes power losses, increased thermal stress, and excessive capacitor voltage fluctuations. Existing passive and active methods often lack clear design guidelines or fail to achieve robust suppression under varying operating conditions. This paper introduces a comprehensive hybrid strategy that addresses these gaps through two key innovations. Firstly, an analytical expression for arm inductor sizing is derived using instantaneous power theory and the harmonic addition theorem. It offers an explicit passive design method rather than relying on heuristic selection. This analytical formulation ensures optimal passive suppression within practical inductor size constraints.Then an advanced active suppression scheme is developed. Unlike conventional approaches, the circulating current is regulated using a vector control strategy formulated in the dq reference frame. It enables precise control of the dominant second-order harmonic. The PI controller is tuned through a direct pole placement method. A high-pass filter is integrated upstream of the controller to eliminate the DC offset. The simulation studies demonstrates that the proposed methods outperforms traditional direct modulation by significantly reducing circulating current amplitude, lowering power losses and improving thermal performance. The results confirm that the passive and active control framework delivers a robust, scalable, and practically implementable solution for next-generation MMC-based renewable energy systems.
- 15 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 124471-124482
Open AccessDesign and Implementation of Active Control Method for Minimizing Circulating Current in MMC-VSC System
Modular Multilevel Converters (MMCs) have emerged as a key technology for large-scale renewable energy integration due to their scalability, fault tolerance, and superior output quality. However, internal circulating currents remain a major barrier to efficiency and long-term reliability. It causes power losses, increased thermal stress, and excessive capacitor voltage fluctuations. Existing passive and active methods often lack clear design guidelines or fail to achieve robust suppression under varying operating conditions. This paper introduces a comprehensive hybrid strategy that addresses these gaps through two key innovations. Firstly, an analytical expression for arm inductor sizing is derived using instantaneous power theory and the harmonic addition theorem. It offers an explicit passive design method rather than relying on heuristic selection. This analytical formulation ensures optimal passive suppression within practical inductor size constraints.Then an advanced active suppression scheme is developed. Unlike conventional approaches, the circulating current is regulated using a vector control strategy formulated in the dq reference frame. It enables precise control of the dominant second-order harmonic. The PI controller is tuned through a direct pole placement method. A high-pass filter is integrated upstream of the controller to eliminate the DC offset. The simulation studies demonstrates that the proposed methods outperforms traditional direct modulation by significantly reducing circulating current amplitude, lowering power losses and improving thermal performance. The results confirm that the passive and active control framework delivers a robust, scalable, and practically implementable solution for next-generation MMC-based renewable energy systems.
- Open Access
- 16 November 2024
- Published by Center of Biomass and Renewable Energy Scientia Academy in International Journal of Renewable Energy Development
- Vol. 14 (1) , 62-71
Analytical computation of arm inductor for minimizing MMC circulating current using passive method
The study of circulating currents in modular multilevel converters is vital for improving their efficiency and reliability. The circulating current may arise from capacitor voltage unbalancing, modulation imperfections, load variations, and transient conditions. Such currents typically induce distortions in arm currents, exhibiting second-order harmonics that lead to power losses and negatively impact the ratings of converter components as well as the amplitudes of capacitor voltage ripples. Despite ongoing research, effective strategies to mitigate circulating currents are limited. This paper aims to systematically address this issue by selecting key design parameters specifically arm inductance and capacitor values, to suppress circulating currents. The methodology incorporates harmonic analysis and instantaneous power theory to derive expressions for arm inductance. Initial modelling includes common mode and differential mode analyses, leading to an examination of harmonic content. Analysis reveals that the selection of the arm inductor value is mainly influenced by the second-order harmonic component, whereas the capacitor value is determined by the fundamental harmonic component. By adopting this methodology, the boundary limit for arm inductor selection can be determined. This article proposes a novel expression for arm inductor selection. The proposed expression mainly depends on factors such as load, submodule capacitor voltages, submodule capacitor, and differential current. By selecting an appropriate inductor value based on converter-rated parameters, circulating current within the system can be effectively suppressed. The methodology offers a practical framework for arm inductor selection. Simulation results validation shows strong alignment with analytical results with the error margin of less than 1%, hereby the MMC parameter can be determined with better accuracy through analytic method.
- 16 November 2024
- Published by Center of Biomass and Renewable Energy Scientia Academy in International Journal of Renewable Energy Development
- Vol. 14 (1) , 62-71
Open AccessAnalytical computation of arm inductor for minimizing MMC circulating current using passive method
The study of circulating currents in modular multilevel converters is vital for improving their efficiency and reliability. The circulating current may arise from capacitor voltage unbalancing, modulation imperfections, load variations, and transient conditions. Such currents typically induce distortions in arm currents, exhibiting second-order harmonics that lead to power losses and negatively impact the ratings of converter components as well as the amplitudes of capacitor voltage ripples. Despite ongoing research, effective strategies to mitigate circulating currents are limited. This paper aims to systematically address this issue by selecting key design parameters specifically arm inductance and capacitor values, to suppress circulating currents. The methodology incorporates harmonic analysis and instantaneous power theory to derive expressions for arm inductance. Initial modelling includes common mode and differential mode analyses, leading to an examination of harmonic content. Analysis reveals that the selection of the arm inductor value is mainly influenced by the second-order harmonic component, whereas the capacitor value is determined by the fundamental harmonic component. By adopting this methodology, the boundary limit for arm inductor selection can be determined. This article proposes a novel expression for arm inductor selection. The proposed expression mainly depends on factors such as load, submodule capacitor voltages, submodule capacitor, and differential current. By selecting an appropriate inductor value based on converter-rated parameters, circulating current within the system can be effectively suppressed. The methodology offers a practical framework for arm inductor selection. Simulation results validation shows strong alignment with analytical results with the error margin of less than 1%, hereby the MMC parameter can be determined with better accuracy through analytic method.
- Open Access
- 7 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 36404-36414
Fault Handling Capabilities of Grid-Forming Wind Turbines in Offshore Wind Farms Connected With MMC HVDC System
Offshore wind power generation equipped with conventional grid following controls challenges the power system stability by reducing the inertia of the grid and weakening the AC offshore grid. To overcome this vulnerability a promising solution could be equipping the wind turbines with grid-forming (GFM) control schemes. Many methodologies have been presented in the literature for GFM inverters. In spite of this, their applications for WTGs have not been thoroughly explored. This paper presents the study of fault handling capability of wind turbines with several grid-forming control strategies. In this context, four different control schemes i.e. Visynch, P/f droop, Q/f droop and conventional grid following control are considered. The performance of these control strategies is assessed and compared during a three-phase symmetrical fault on the point of common coupling of an offshore wind farm. A case study which consists of two wind turbines connected to the main converter of an offshore substation equipped with grid-forming control is also considered. The results indicate that, during faults, each of the four control strategies (Visynch, P/f droop, Q/f droop, and Gfol) effectively limits the current and restores normal operation. A significant advantage of Q/F droop control is its reduced sensitivity to variations in system and fault parameters, adjustable frequency response, and independence from existing Phase-Locked Loops (PLLs). On the other hand, the P/f droop control provides greater voltage support during faults due to its voltage controllers. However, post-fault oscillations result from the stiff voltage controller. Visynch control, on the other hand, shows a lower margin of stability. The advantages and weaknesses of each control scheme is revealed using the simulation results.
- 7 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 36404-36414
Open AccessFault Handling Capabilities of Grid-Forming Wind Turbines in Offshore Wind Farms Connected With MMC HVDC System
Offshore wind power generation equipped with conventional grid following controls challenges the power system stability by reducing the inertia of the grid and weakening the AC offshore grid. To overcome this vulnerability a promising solution could be equipping the wind turbines with grid-forming (GFM) control schemes. Many methodologies have been presented in the literature for GFM inverters. In spite of this, their applications for WTGs have not been thoroughly explored. This paper presents the study of fault handling capability of wind turbines with several grid-forming control strategies. In this context, four different control schemes i.e. Visynch, P/f droop, Q/f droop and conventional grid following control are considered. The performance of these control strategies is assessed and compared during a three-phase symmetrical fault on the point of common coupling of an offshore wind farm. A case study which consists of two wind turbines connected to the main converter of an offshore substation equipped with grid-forming control is also considered. The results indicate that, during faults, each of the four control strategies (Visynch, P/f droop, Q/f droop, and Gfol) effectively limits the current and restores normal operation. A significant advantage of Q/F droop control is its reduced sensitivity to variations in system and fault parameters, adjustable frequency response, and independence from existing Phase-Locked Loops (PLLs). On the other hand, the P/f droop control provides greater voltage support during faults due to its voltage controllers. However, post-fault oscillations result from the stiff voltage controller. Visynch control, on the other hand, shows a lower margin of stability. The advantages and weaknesses of each control scheme is revealed using the simulation results.
- Open Access
- 7 October 2023
- Published by MDPI AG in Journal of Low Power Electronics and Applications
- Vol. 13 (4) , 54
Design and Optimization of an Ultra-Low-Power Cross-Coupled LC VCO with a DFF Frequency Divider for 2.4 GHz RF Receivers Using 65 nm CMOS Technology
This article presents the design and optimization of a tunable quadrature differential LC CMOS voltage-controlled oscillator (VCO) with a D flip-flop (DFF) frequency divider. The VCO is designed for the low-power and low-phase-noise applications of 2.4 GHz IoT/BLE receivers and wireless sensor devices. The proposed design comprises the proper stacking of an LC VCO and a DFF frequency divider and is simulated using a TSMC 65 nm CMOS technology, and it has a tuning range of 4.4 to 5.7 GHz. The voltage headroom is preserved using a high-impedance on-chip passive inductor at the tail for filtering and enabling true differential operation. The VCO and frequency divider consume as low as 2.02 mW altogether, with the VCO section consuming only 0.47 mW. The active area of the chip including the pads is only 0.47 mm2. The designed VCO achieved a much better phase noise of −118.36 dBc/Hz at a 1 MHz offset frequency with 1.2 V supply voltages. The design produced a much better FoM of −196.44 dBc/Hz compared to other related research.
- 7 October 2023
- Published by MDPI AG in Journal of Low Power Electronics and Applications
- Vol. 13 (4) , 54
Open AccessDesign and Optimization of an Ultra-Low-Power Cross-Coupled LC VCO with a DFF Frequency Divider for 2.4 GHz RF Receivers Using 65 nm CMOS Technology
This article presents the design and optimization of a tunable quadrature differential LC CMOS voltage-controlled oscillator (VCO) with a D flip-flop (DFF) frequency divider. The VCO is designed for the low-power and low-phase-noise applications of 2.4 GHz IoT/BLE receivers and wireless sensor devices. The proposed design comprises the proper stacking of an LC VCO and a DFF frequency divider and is simulated using a TSMC 65 nm CMOS technology, and it has a tuning range of 4.4 to 5.7 GHz. The voltage headroom is preserved using a high-impedance on-chip passive inductor at the tail for filtering and enabling true differential operation. The VCO and frequency divider consume as low as 2.02 mW altogether, with the VCO section consuming only 0.47 mW. The active area of the chip including the pads is only 0.47 mm2. The designed VCO achieved a much better phase noise of −118.36 dBc/Hz at a 1 MHz offset frequency with 1.2 V supply voltages. The design produced a much better FoM of −196.44 dBc/Hz compared to other related research.
- Open Access
- 26 September 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 46 (1) , 32
Performance Analysis of Half-Bridge Commutation Cells of a Modular Multilevel Voltage Source Converter
This study presents a performance analysis of a half-bridge commutation cell using MATLAB/Simulink simulations. The behavior of IGBTs as semiconductor switches is examined under diverse load conditions, and the power losses, including conduction and switching losses, of two IGBT models, IXGH25N120 and IRG7IA19UPbF, are evaluated. A simulation-based design methodology is proposed for selecting suitable IGBTs for the half-bridge commutation cell. The comparative analysis reveals that the IXGH25N120 IGBT is well-suited for high-performance applications, while the IRG7IA19UPbF IGBT is optimized for energy recovery circuits. Furthermore, it is observed that IGBT1 (IXGH25N120) exhibits higher power losses due to its significant conduction losses compared to IGBT2 (IRG7IA19UPbF). The IGBT2 exhibits low conduction losses but has dominant switching losses due to high switching frequency. The utilization of a simulation-based approach provides valuable insights into the influence of IGBT characteristics on the responses of the half-bridge commutation cell, enabling an enhanced understanding for the design and performance analysis of the cell within the context of MMC.
- 26 September 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 46 (1) , 32
Open AccessPerformance Analysis of Half-Bridge Commutation Cells of a Modular Multilevel Voltage Source Converter
This study presents a performance analysis of a half-bridge commutation cell using MATLAB/Simulink simulations. The behavior of IGBTs as semiconductor switches is examined under diverse load conditions, and the power losses, including conduction and switching losses, of two IGBT models, IXGH25N120 and IRG7IA19UPbF, are evaluated. A simulation-based design methodology is proposed for selecting suitable IGBTs for the half-bridge commutation cell. The comparative analysis reveals that the IXGH25N120 IGBT is well-suited for high-performance applications, while the IRG7IA19UPbF IGBT is optimized for energy recovery circuits. Furthermore, it is observed that IGBT1 (IXGH25N120) exhibits higher power losses due to its significant conduction losses compared to IGBT2 (IRG7IA19UPbF). The IGBT2 exhibits low conduction losses but has dominant switching losses due to high switching frequency. The utilization of a simulation-based approach provides valuable insights into the influence of IGBT characteristics on the responses of the half-bridge commutation cell, enabling an enhanced understanding for the design and performance analysis of the cell within the context of MMC.
- Open Access
- 6 October 2022
- Published by Taylor & Francis in Automatika
- Vol. 64 (2) , 225-238
Bus selection index for distributed generators placement and sizing in the electrical network
Renewable energy sources, widely considered as distribution generation units, will be essential parts of the future electrical network. They will be integrated into the network at all voltage levels and act as the main controlling elements in the microgrid to stabilize the network. However, the objective of determining the suitable busbar to integrate the renewable generation source and its maximum capacity is still an indecisive problem. This article presents a methodology to select suitable busbars to integrate the renewable generation unit. A bus selection index is proposed based on three criteria, i.e. voltage deviation, active power loss, and grid energy infeed. The developed algorithm considers network busbar voltage limit and branch loading as constraints and the solution is determined using analytical technique. Algorithm is implemented in MATLAB, and MATPOWER is used for the power flow analysis. Furthermore, the proposed methodology is analysed on CIGRE and IEEE medium voltage benchmark network.
- 6 October 2022
- Published by Taylor & Francis in Automatika
- Vol. 64 (2) , 225-238
Open AccessBus selection index for distributed generators placement and sizing in the electrical network
Renewable energy sources, widely considered as distribution generation units, will be essential parts of the future electrical network. They will be integrated into the network at all voltage levels and act as the main controlling elements in the microgrid to stabilize the network. However, the objective of determining the suitable busbar to integrate the renewable generation source and its maximum capacity is still an indecisive problem. This article presents a methodology to select suitable busbars to integrate the renewable generation unit. A bus selection index is proposed based on three criteria, i.e. voltage deviation, active power loss, and grid energy infeed. The developed algorithm considers network busbar voltage limit and branch loading as constraints and the solution is determined using analytical technique. Algorithm is implemented in MATLAB, and MATPOWER is used for the power flow analysis. Furthermore, the proposed methodology is analysed on CIGRE and IEEE medium voltage benchmark network.
- Open Access
- 30 September 2021
- Published by Taylor & Francis in Automatika
- Vol. 62 (3-4) , 454-470
Voltage and reactive power correlation in multi-objective optimization of an offshore grid
In the last few years, many offshore wind power plants are installed at North Sea and more are under construction. Offshore grid would be vital in the integration of future offshore wind power plant with the main land grid. Both, multi-terminal DC and AC cable systems are under consideration in the concept of future offshore grid. The reactive power and voltage operating point for such a network is important for the optimized operation. This article presents an optimization criterion of voltage and reactive power control for an offshore AC grid having a parallel connecting grid-forming converter. Multi-objective optimization problem is formulated considering four reactive power management strategies. The solution of the optimization algorithm is analysed and compared with respect to active power losses in the network, voltage variation, and reactive power contribution by the sources. The research presents a methodology to apply a suitable reactive power management strategy to achieve the best optimum operating points. The solution provides the optimum operating points for offshore wind farm reactive power, frequency and voltage droop gain values for VSC-HVDC system, and reactive power sharing factor of HVDC transmission.
- 30 September 2021
- Published by Taylor & Francis in Automatika
- Vol. 62 (3-4) , 454-470
Open AccessVoltage and reactive power correlation in multi-objective optimization of an offshore grid
In the last few years, many offshore wind power plants are installed at North Sea and more are under construction. Offshore grid would be vital in the integration of future offshore wind power plant with the main land grid. Both, multi-terminal DC and AC cable systems are under consideration in the concept of future offshore grid. The reactive power and voltage operating point for such a network is important for the optimized operation. This article presents an optimization criterion of voltage and reactive power control for an offshore AC grid having a parallel connecting grid-forming converter. Multi-objective optimization problem is formulated considering four reactive power management strategies. The solution of the optimization algorithm is analysed and compared with respect to active power losses in the network, voltage variation, and reactive power contribution by the sources. The research presents a methodology to apply a suitable reactive power management strategy to achieve the best optimum operating points. The solution provides the optimum operating points for offshore wind farm reactive power, frequency and voltage droop gain values for VSC-HVDC system, and reactive power sharing factor of HVDC transmission.
- Open Access
- 28 July 2019
- Published by Taylor & Francis in Automatika
- Vol. 60 (4) , 432-442
Active and reactive power control of hybrid offshore AC and DC grids
The future ‘SuperGrid’ may requires the benefit of both offshore AC network and multi-terminal DC grid. AC cable limits the power transfer capability from the larger offshore wind farm, however, HVDC transmission system is economical viable for large power wind farm integration with the grid. Another approach to develop the offshore network infrastructure is by forming an offshore AC grid connecting several offshore wind farms. Then, this offshore AC network is connected with different onshore grid using HVDC system. This enhances the trade among the countries as well as provide an economical solution for wind energy integration. In this article, operational and control concept of voltage source converter is presented to integrate an offshore AC grid with an offshore DC grid. The article presents the control principle of offshore AC network frequency and voltage with respect to active and reactive power distribution in the AC network. Later, the principle of multi-terminal HVDC system is discussed with respect to power distribution using DC voltage droop control. Power distribution criteria are defined with respect to operator power-sharing requirement and network stability. In the end, a hybrid AC/DC offshore grid is modelled and simulated in MATLAB/SIMULINK to validate the distribution criteria.
- 28 July 2019
- Published by Taylor & Francis in Automatika
- Vol. 60 (4) , 432-442
Open AccessActive and reactive power control of hybrid offshore AC and DC grids
The future ‘SuperGrid’ may requires the benefit of both offshore AC network and multi-terminal DC grid. AC cable limits the power transfer capability from the larger offshore wind farm, however, HVDC transmission system is economical viable for large power wind farm integration with the grid. Another approach to develop the offshore network infrastructure is by forming an offshore AC grid connecting several offshore wind farms. Then, this offshore AC network is connected with different onshore grid using HVDC system. This enhances the trade among the countries as well as provide an economical solution for wind energy integration. In this article, operational and control concept of voltage source converter is presented to integrate an offshore AC grid with an offshore DC grid. The article presents the control principle of offshore AC network frequency and voltage with respect to active and reactive power distribution in the AC network. Later, the principle of multi-terminal HVDC system is discussed with respect to power distribution using DC voltage droop control. Power distribution criteria are defined with respect to operator power-sharing requirement and network stability. In the end, a hybrid AC/DC offshore grid is modelled and simulated in MATLAB/SIMULINK to validate the distribution criteria.
- 1 January 2019
- Published by Elsevier in Applied Energy
- Vol. 233-234, 524-543
Integral approach to energy planning and electric grid assessment in a renewable energy technology integration for a 50/50 target applied to a small island
- 1 January 2019
- Published by Elsevier in Applied Energy
- Vol. 233-234, 524-543
Integral approach to energy planning and electric grid assessment in a renewable energy technology integration for a 50/50 target applied to a small island
- 1 November 2018
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 102, 364-380
Short circuit analysis of an offshore AC network having multiple grid forming VSC-HVDC links
- 1 November 2018
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 102, 364-380
Short circuit analysis of an offshore AC network having multiple grid forming VSC-HVDC links