AMAngel Mancebo

Angel Mancebo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Angel Mancebo has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    ULK1 forms distinct oligomeric states and nanoscopic structures during autophagy initiation

    by Chiranjib Banerjee, Dushyant Mehra, Daihyun Song, Angel Mancebo, Ji-Man Park, Do-Hyung Kim, Elias M. Puchner

    Autophagy induction involves extensive molecular and membrane reorganization. Despite substantial progress, the mechanism underlying autophagy initiation remains poorly understood. Here, we used quantitative photoactivated localization microscopy with single-molecule sensitivity to analyze the nanoscopic distribution of endogenous ULK1, the kinase that triggers autophagy. Under amino acid starvation, ULK1 formed large clusters containing up to 161 molecules at the endoplasmic reticulum. Cross-correlation analysis revealed that ULK1 clusters engaging in autophagosome formation require 30 or more molecules. The ULK1 structures with more than the threshold number contained varying levels of Atg13, Atg14, Atg16, LC3B, GEC1, and WIPI2. We found that ULK1 activity is dispensable for the initial clustering of ULK1, but necessary for the subsequent expansion of the clusters, which involves interaction with Atg14, Atg16, and LC3B and relies on Vps34 activity. This quantitative analysis at the single-molecule level has provided unprecedented insights into the behavior of ULK1 during autophagy initiation.


  • Open Access

    ULK1 forms distinct oligomeric states and nanoscopic structures during autophagy initiation

    by Chiranjib Banerjee, Dushyant Mehra, Daihyun Song, Angel Mancebo, Do-Hyung Kim, Elias M. Puchner

    Autophagy induction involves extensive molecular and membrane reorganization. Despite significant progress, the mechanism underlying autophagy initiation remains poorly understood. Here, we used quantitative Photoactivated Localization Microscopy with single-molecule sensitivity to analyze the nanoscopic distribution of endogenous ULK1, the kinase that triggers autophagy. Under amino acid starvation, ULK1 formed large clusters containing up to 161 molecules at the endoplasmic reticulum. Cross-correlation analysis revealed that ULK1 clusters engaging in autophagosome formation require 30 or more molecules. The ULK1 structures with more than the threshold number contained varying levels of Atg13, Atg14, Atg16, LC3B, GEC1 and WIPI2. We found that ULK1 activity is dispensable for the initial clustering of ULK1, but necessary for the subsequent expansion of the clusters, which involves interaction with Atg14, Atg16, and LC3B and relies on Vps34 activity. This quantitative analysis at the single molecule level has provided unprecedented insights into the behavior of ULK1 during autophagy initiation.


  • Precisely calibrated and spatially informed illumination for conventional fluorescence and improved PALM imaging applications

    by Angel Mancebo, Luke DeMars, Christopher T. Ertsgaard, Elias M. Puchner

    Spatial light modulation using cost efficient digital micromirror devices (DMD) is finding broad applications in fluorescence microscopy due to the reduction of phototoxicity and bleaching and the ability to manipulate proteins in optogenetic experiments. However, precise illumination by DMDs and their application to single-molecule localization microscopy (SMLM) remained a challenge because of non-linear distortions between the DMD and camera coordinate systems caused by optical components in the excitation and emission path. Here we develop a fast and easy to implement calibration procedure that determines these distortions and matches the DMD and camera coordinate system with a precision below the optical diffraction limit. As a result, a region from a fluorescence image can be selected with a higher precision for illumination compared to a rigid transformation allowed by manual alignment of the DMD. We first demonstrate the application of our precisely calibrated light modulation by performing a proof of concept fluorescence recovery after photobleaching experiment with the endoplasmic reticulum-localized protein IRE1 fused to GFP in budding yeast (S. cerevisiae). Next, we develop a spatially informed photoactivation approach for SMLM in which only regions of the cell that contain photoactivatable fluorescent proteins are selected for photoactivation. The reduced exposure of the cells to 405 nm light increased the possible imaging time by 44% until phototoxic effects cause a dominant fluorescence background and a change in cell morphology. As a result, the mean number of reliable single-molecule localizations was also significantly increased by 28%. Since the localization precision and the ability for single-molecule tracking is not altered compared to traditional photoactivation of the entire field of view, spatially informed photoactivation significantly improves the quality of SMLM images and single-molecule tracking data. Our precise calibration method therefore lays the foundation for improved SMLM with active feedback photoactivation far beyond the applications in this work.


  • Open Access

    Calibrated feedback illumination for precise conventional fluorescence and PALM imaging applications

    by A. Mancebo, L. DeMars, C. T. Ertsgaard, E. M. Puchner

    Spatial light modulation using cost efficient digital mirror arrays (DMA) is finding broad applications in fluorescence microscopy due to the reduction of phototoxicity and bleaching and the ability to manipulate proteins in optogenetic experiments. However, the precise calibration of DMAs and their application to single-molecule localization microscopy (SMLM) remained a challenge because of non-linear distortions between the DMA and camera coordinate system caused by optical components. Here we develop a fast and easy to implement calibration procedure that determines these distortions by means of an optical feedback and matches the DMA and camera coordinate system with ~50 nm precision. As a result, a region from a fluorescence image can be selected with a higher precision for illumination compared to manual alignment of the DMA. We first demonstrate the application of our precisely calibrated light modulation by performing a proof-of concept fluorescence recovery after photobleaching experiment with the endoplasmic reticulum-localized protein IRE1 fused to GFP. Next, we develop a spatial feedback photoactivation approach for SMLM in which only regions of the cell are selected for photoactivation that contain photoactivatable fluorescent proteins. The reduced exposure of the cells to 405 nm light increases the possible imaging time by 44% until phototoxic effects cause a dominant fluorescence background and a change in the cell’s morphology. As a result, the mean number of reliable single molecule localizations is also significantly increased by 28%. Since the localization precision and the ability for single molecule tracking is not altered compared to traditional photoactivation of the entire field of view, spatial feedback photoactivation significantly improves the quality of SMLM images and the precision of single molecule tracking. Our calibration method therefore lays the foundation for improved SMLM with active feedback photoactivation far beyond the applications in this work. Statement of significance: Actively patterned illumination in fluorescence microscopy can reduce bleaching and phototoxicity as well as actively manipulate proteins in optogenetic applications. Matching the coordinate system of the camera and the light patterning device such as digital mirror arrays (DMA) remains a challenge. We developed a fast and easy calibration procedure that determines and corrects for the transformation between the camera and DMA coordinate system with ~50 nm precision. Using this approach, we develop spatial feedback photoactivation for Single Molecule Localization Microscopy (SMLM) to photoswitch only intracellular regions containing photoswitchable fluorophores. Our results show a 44% improvement in the possible data acquisition time before phototoxic effects become detectable and a 28% increase in detected localizations. Spatial feedback photoactivation thus significantly improves SMLM experiments.