Scott O. Trerotola
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Scott O. Trerotola has a total of 168 co-authors. Here are the top co-authors by number of shared publications:
S. William Stavropoulos
Univ Penn, Perelman Sch Med, Div Intervent Radiol, Med Ctr,Dept Radiol, Philadelphia, PA 19104 USA
23 shared publications- Richard D. Shlansky Goldberg
Division of Interventional Radiology, Department of Radiology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania
11 shared publications Timothy W.I. Clark
Department of Radiology, Division of Interventional Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA
11 shared publicationsJeffrey I. Mondschein
Department of Radiology, Division of Interventional Radiology, Perelman School of Medicine of the University of Pennsylvania, 1 Silverstein, 3400 Spruce St., Philadelphia, PA 19104
10 shared publicationsJesse Chittams
Biostatistics Consulting Unit, Office of Nursing Research, University of Pennsylvania School of Nursing, Philadelphia, PA
9 shared publicationsMichael C. Soulen
Department of Radiology, Division of Interventional Radiology, Perelman School of Medicine of the University of Pennsylvania, 1 Silverstein, 3400 Spruce St., Philadelphia, PA 19104
9 shared publications
Latest Publications
- Open Access
- 27 November 2025
- Published by Springer Nature in CVIR Endovascular
- Vol. 8  (1) , 104
Patient interpretation and implementation of air embolism prevention guidelines in hereditary hemorrhagic telangiectasia (HHT): a survey-based study
Background: To assess how patients interpret and adhere to the International HHT Guidelines’ recommendation to avoid intravenous (IV) air and to evaluate whether misinterpretation of this guidance as a strict requirement for in-line bubble filters may inadvertently hinder access to care. An anonymous 15-question survey was distributed to 7000 members of the HHT Research Network. The survey assessed awareness of the guideline, perceived necessity of bubble filter use, and the practical consequences of filter use. Responses were excluded if incomplete or submitted by individuals under 18 years old. Results: Of the 596 responses received (9% response rate), 446 met inclusion criteria. Most respondents (79%) were aware of the guideline, and 66% interpreted it as requiring use of an IV bubble filter. Notably, 16% of respondents reported refusing care, and 25% reported delaying treatment—most often patient-initiated—due to perceived filter requirements. The interventions affected included essential and, in some cases, urgent care. In total, 20 respondents (4%) reported experiencing a transient ischemic attack (TIA) during IV therapy; two of these occurred despite filter use, and none resulted in permanent deficits. Patients who did not use filters were significantly less likely to report difficulty accessing care ( p < 0.05). Conclusions: Although the guideline advises caution in avoiding IV air, many patients interpret it as mandating bubble filter use. This misunderstanding has been linked to delays in necessary care, increased patient frustration, and limited treatment access. These findings underscore the importance of clearer communication and education around guideline intent to mitigate unintended consequences.
- 27 November 2025
- Published by Springer Nature in CVIR Endovascular
- Vol. 8  (1) , 104
Open AccessPatient interpretation and implementation of air embolism prevention guidelines in hereditary hemorrhagic telangiectasia (HHT): a survey-based study
Background: To assess how patients interpret and adhere to the International HHT Guidelines’ recommendation to avoid intravenous (IV) air and to evaluate whether misinterpretation of this guidance as a strict requirement for in-line bubble filters may inadvertently hinder access to care. An anonymous 15-question survey was distributed to 7000 members of the HHT Research Network. The survey assessed awareness of the guideline, perceived necessity of bubble filter use, and the practical consequences of filter use. Responses were excluded if incomplete or submitted by individuals under 18 years old. Results: Of the 596 responses received (9% response rate), 446 met inclusion criteria. Most respondents (79%) were aware of the guideline, and 66% interpreted it as requiring use of an IV bubble filter. Notably, 16% of respondents reported refusing care, and 25% reported delaying treatment—most often patient-initiated—due to perceived filter requirements. The interventions affected included essential and, in some cases, urgent care. In total, 20 respondents (4%) reported experiencing a transient ischemic attack (TIA) during IV therapy; two of these occurred despite filter use, and none resulted in permanent deficits. Patients who did not use filters were significantly less likely to report difficulty accessing care ( p < 0.05). Conclusions: Although the guideline advises caution in avoiding IV air, many patients interpret it as mandating bubble filter use. This misunderstanding has been linked to delays in necessary care, increased patient frustration, and limited treatment access. These findings underscore the importance of clearer communication and education around guideline intent to mitigate unintended consequences.
- Open Access
- 12 November 2025
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 32  (1) , 119-124
Factors affecting the difficulty of transurethral double J stent removal in patients with renal transplants
Factors affecting the difficulty of transurethral double J stent removal in patients with renal transplants - Diagnostic and Interventional Radiology
- 12 November 2025
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 32  (1) , 119-124
Open AccessFactors affecting the difficulty of transurethral double J stent removal in patients with renal transplants
Factors affecting the difficulty of transurethral double J stent removal in patients with renal transplants - Diagnostic and Interventional Radiology
- Open Access
- 4 September 2025
- Published by Springer Nature in Research Square
Patient Interpretation and Implementation of Air Embolism Prevention Guidelines in Hereditary Hemorrhagic Telangiectasia (HHT): A Survey-Based Study
Background To assess how patients interpret and adhere to the International HHT Guidelines’ recommendation to avoid intravenous (IV) air, and to evaluate whether misinterpretation of this guidance as a strict requirement for in-line bubble filters may inadvertently hinder access to care. An anonymous 15-question survey was distributed to 7,000 members of the HHT Research Network. The survey assessed awareness of the guideline, perceived necessity of bubble filter use, and the practical consequences of filter use. Responses were excluded if incomplete or submitted by individuals under 18 years old. Results Of the 596 responses received (9% response rate), 446 met inclusion criteria. Most respondents (79%) were aware of the guideline, and 66% interpreted it as requiring use of an IV bubble filter. Notably, 16% of respondents reported refusing care, and 25% reported delaying treatment—most often patient-initiated—due to perceived filter requirements. The interventions affected included essential and, in some cases, urgent care. In total, 20 respondents (4%) reported experiencing a transient ischemic attack (TIA) during IV therapy; two of these occurred despite filter use, and none resulted in permanent deficits. Patients who did not use filters were significantly less likely to report difficulty accessing care (p < 0.05). Conclusions Although the guideline advises caution in avoiding IV air, many patients interpret it as mandating bubble filter use. This misunderstanding has been linked to delays in necessary care, increased patient frustration, and limited treatment access. These findings underscore the importance of clearer communication and education around guideline intent to mitigate unintended consequences.
- 4 September 2025
- Published by Springer Nature in Research Square
Open AccessPatient Interpretation and Implementation of Air Embolism Prevention Guidelines in Hereditary Hemorrhagic Telangiectasia (HHT): A Survey-Based Study
Background To assess how patients interpret and adhere to the International HHT Guidelines’ recommendation to avoid intravenous (IV) air, and to evaluate whether misinterpretation of this guidance as a strict requirement for in-line bubble filters may inadvertently hinder access to care. An anonymous 15-question survey was distributed to 7,000 members of the HHT Research Network. The survey assessed awareness of the guideline, perceived necessity of bubble filter use, and the practical consequences of filter use. Responses were excluded if incomplete or submitted by individuals under 18 years old. Results Of the 596 responses received (9% response rate), 446 met inclusion criteria. Most respondents (79%) were aware of the guideline, and 66% interpreted it as requiring use of an IV bubble filter. Notably, 16% of respondents reported refusing care, and 25% reported delaying treatment—most often patient-initiated—due to perceived filter requirements. The interventions affected included essential and, in some cases, urgent care. In total, 20 respondents (4%) reported experiencing a transient ischemic attack (TIA) during IV therapy; two of these occurred despite filter use, and none resulted in permanent deficits. Patients who did not use filters were significantly less likely to report difficulty accessing care (p < 0.05). Conclusions Although the guideline advises caution in avoiding IV air, many patients interpret it as mandating bubble filter use. This misunderstanding has been linked to delays in necessary care, increased patient frustration, and limited treatment access. These findings underscore the importance of clearer communication and education around guideline intent to mitigate unintended consequences.
- Open Access
- 4 February 2025
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 48  (5) , 619-625
Long-Term Durability of Tunneled Hemodialysis Catheters: Outcomes from a Single Institution 22-Year Experience
Purpose: To describe long-term physical durability of tunneled hemodialysis catheters, highlighted in the 2019 Kidney Disease Outcomes Quality Initiative (KDOQI) guidelines as a specific area for future research. Materials and Methods: Tunneled hemodialysis catheters with known outcomes and dwell times > 1 year were entered into this retrospective study. Data includes demographics, complications, catheter type, dwell time, reason for removal, access site, and placement via exchange or de novo. Catheter durability < 1 year dwell was analyzed as a secondary aim. Results: 272 catheters in 229 patients were included. Dwell times ranged from 366 to 3,802 days (median 504), totaling 162,439 catheter days. 17 (6%) catheters > 1 year dwell had broken external components. For these, dwell times until breaking ranged from 377 to 1,436 days (median 489), totaling 10,434 catheter days. 5 had a broken hub, 11 had a broken clamp, and 1 had broken hub and clamp. 12 were Ash Split Cath (n = 240) and 5 were Arrow-Clark VectorFlow (n = 32). In the durability < 1 year sub-analysis, 6,515 catheters with dwell times < 1 year in 3,693 patients were included, totaling 425,018 catheter days. 48 were damaged, with 24 broken hubs, 17 broken clamps, and 7 holes. Median time to breakage was 110 days. 38 were Ash Split Cath (n = 5,636) and 10 Arrow-Clark VectorFlow (n = 812). In both analyses, breakage was limited to hubs, clamps, and extensions. Conclusions: Tunneled hemodialysis catheters are exceptionally durable, rarely requiring removal for hub-related issues after one year. Breakdown was not observed as a long-term durability issue. Further, broken external components can be replaced using external repair kits. Level of Evidence: Level 2b, Retrospective Study. Graphical
- 4 February 2025
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 48  (5) , 619-625
Open AccessLong-Term Durability of Tunneled Hemodialysis Catheters: Outcomes from a Single Institution 22-Year Experience
Purpose: To describe long-term physical durability of tunneled hemodialysis catheters, highlighted in the 2019 Kidney Disease Outcomes Quality Initiative (KDOQI) guidelines as a specific area for future research. Materials and Methods: Tunneled hemodialysis catheters with known outcomes and dwell times > 1 year were entered into this retrospective study. Data includes demographics, complications, catheter type, dwell time, reason for removal, access site, and placement via exchange or de novo. Catheter durability < 1 year dwell was analyzed as a secondary aim. Results: 272 catheters in 229 patients were included. Dwell times ranged from 366 to 3,802 days (median 504), totaling 162,439 catheter days. 17 (6%) catheters > 1 year dwell had broken external components. For these, dwell times until breaking ranged from 377 to 1,436 days (median 489), totaling 10,434 catheter days. 5 had a broken hub, 11 had a broken clamp, and 1 had broken hub and clamp. 12 were Ash Split Cath (n = 240) and 5 were Arrow-Clark VectorFlow (n = 32). In the durability < 1 year sub-analysis, 6,515 catheters with dwell times < 1 year in 3,693 patients were included, totaling 425,018 catheter days. 48 were damaged, with 24 broken hubs, 17 broken clamps, and 7 holes. Median time to breakage was 110 days. 38 were Ash Split Cath (n = 5,636) and 10 Arrow-Clark VectorFlow (n = 812). In both analyses, breakage was limited to hubs, clamps, and extensions. Conclusions: Tunneled hemodialysis catheters are exceptionally durable, rarely requiring removal for hub-related issues after one year. Breakdown was not observed as a long-term durability issue. Further, broken external components can be replaced using external repair kits. Level of Evidence: Level 2b, Retrospective Study. Graphical
- 12 August 2024
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 35  (11) , 1701-1705
Adrenal Vein Sampling Results and Surgical Outcomes in Patients with Nonsuppressed Plasma Renin Activity
- 12 August 2024
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 35  (11) , 1701-1705
Adrenal Vein Sampling Results and Surgical Outcomes in Patients with Nonsuppressed Plasma Renin Activity
- 1 January 2024
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 35  (4) , 601-610
Percutaneous Management of Dialysis Access Steal Syndrome: Interventions and Outcomes from a Single Institution’s 20-Year Experience
- 1 January 2024
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 35  (4) , 601-610
Percutaneous Management of Dialysis Access Steal Syndrome: Interventions and Outcomes from a Single Institution’s 20-Year Experience
- 30 December 2023
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 35  (4) , 583-591.e1
Supply Costs in Complex and Routine Inferior Vena Cava Filter Retrieval: 10 Years' Data from a Single Center
- 30 December 2023
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 35  (4) , 583-591.e1
Supply Costs in Complex and Routine Inferior Vena Cava Filter Retrieval: 10 Years' Data from a Single Center
- 1 December 2023
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 43  (12) , e230139
Quality Improvement Report: Design and Implementation of a Radiology E-Consult Service
Electronic consultations (e-consults) mediated through an electronic health record system or web-based platform allow synchronous or asynchronous physician-to-physician communication. E-consults have been explored in various clinical specialties, but relatively few instances in the literature describe e-consults to connect health care providers directly with radiologists.The authors outline how a radiology department can implement an e-consult service and review the development of such a service in a large academic health system. They describe the logistics, workflow, turnaround time expectations, stakeholder management, and pilot implementation and highlight challenges and lessons learned.
- 1 December 2023
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 43  (12) , e230139
Quality Improvement Report: Design and Implementation of a Radiology E-Consult Service
Electronic consultations (e-consults) mediated through an electronic health record system or web-based platform allow synchronous or asynchronous physician-to-physician communication. E-consults have been explored in various clinical specialties, but relatively few instances in the literature describe e-consults to connect health care providers directly with radiologists.The authors outline how a radiology department can implement an e-consult service and review the development of such a service in a large academic health system. They describe the logistics, workflow, turnaround time expectations, stakeholder management, and pilot implementation and highlight challenges and lessons learned.
- 13 November 2023
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 46  (12) , 1694-1695
Percutaneous Thrombolytic Device (PTD): Gone but not Forgotten
- 13 November 2023
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 46  (12) , 1694-1695
Percutaneous Thrombolytic Device (PTD): Gone but not Forgotten