Muge Yucel
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Muge Yucel has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Umit Hakan Yildiz
Izmir Institute of Technology (IZTECH)
6 shared publications - Sezer Özenler
Department of Chemistry
3 shared publications - Bo Liedberg
Center for Biomimetic Sensor Science, School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Drive, Singapore 637553, Singapore
2 shared publications Ahu Arslan Yildiz
Department of Bioengineering Izmir Institute of Technology Izmir 35430 Turkey
1 shared publicationAlagappan Palaniappan
Center for Biomimetic Sensor Science, School of Materials Science and Engineering , Nanyang Technological University , 637553 Singapore
1 shared publication- Alagappan Palaniappan
School of Materials Science and Engineering, Nanyang Technological University, Singapore 639798, Singapore
1 shared publication
Latest Publications
- Open Access
- 11 June 2026
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 42 (25) , 17809-17818
Covalent Grafting of Cationic Polythiophene Nanowires onto a Polyurethane Interface via Surface-Assisted Polymerization
We report a robust and scalable approach for covalently grafting cationic polythiophene (CPT) nanowires onto polyurethane (PU)-functionalized gold surfaces using a surface-assisted (SurfAst) polymerization strategy. The methodology involves sequential incubations of hexamethylene diisocyanate (HDI) and 1,4-butanediol (1,4-BDO) on an 11-mercaptoundecanoic acid (MUA)-functionalized gold substrate, forming an OH-terminated PU interface. Subsequent functionalization with 2-isocyanatoethyl methacrylate yields a methacrylate-terminated PU interface, enabling the grafting of CPT nanowires through an UV-induced reaction between the methacrylate group on the PU interface and the allyl moieties of CPT. Atomic force microscopy (AFM) reveals the formation of highly elongated and well-defined CPT nanowires with stability. Electrostatic force microscopy (EFM) further confirms distinct phase shifts in the CPT-grafted regions. These findings demonstrate not only the successful immobilization of CPT on the PU-functionalized gold surface but also the preservation of accessible cationic functionalities, which ensure surface activity. A key aspect of this platform is the use of ethylene glycol (EG) as the solvent for CPT during the grafting process, which facilitates well-dissolved CPT chains and may provide the polymer in a dispersed state in solution, allowing effective interaction with the functionalized surface. These results establish a chemically robust and electrostatically tunable CPT-PU interphase, offering new opportunities for integration into next-generation electronic and sensing technologies.
- 11 June 2026
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 42 (25) , 17809-17818
Open AccessCovalent Grafting of Cationic Polythiophene Nanowires onto a Polyurethane Interface via Surface-Assisted Polymerization
We report a robust and scalable approach for covalently grafting cationic polythiophene (CPT) nanowires onto polyurethane (PU)-functionalized gold surfaces using a surface-assisted (SurfAst) polymerization strategy. The methodology involves sequential incubations of hexamethylene diisocyanate (HDI) and 1,4-butanediol (1,4-BDO) on an 11-mercaptoundecanoic acid (MUA)-functionalized gold substrate, forming an OH-terminated PU interface. Subsequent functionalization with 2-isocyanatoethyl methacrylate yields a methacrylate-terminated PU interface, enabling the grafting of CPT nanowires through an UV-induced reaction between the methacrylate group on the PU interface and the allyl moieties of CPT. Atomic force microscopy (AFM) reveals the formation of highly elongated and well-defined CPT nanowires with stability. Electrostatic force microscopy (EFM) further confirms distinct phase shifts in the CPT-grafted regions. These findings demonstrate not only the successful immobilization of CPT on the PU-functionalized gold surface but also the preservation of accessible cationic functionalities, which ensure surface activity. A key aspect of this platform is the use of ethylene glycol (EG) as the solvent for CPT during the grafting process, which facilitates well-dissolved CPT chains and may provide the polymer in a dispersed state in solution, allowing effective interaction with the functionalized surface. These results establish a chemically robust and electrostatically tunable CPT-PU interphase, offering new opportunities for integration into next-generation electronic and sensing technologies.
- 10 January 2024
- Published by Wiley in Macromolecular Bioscience
- Vol. 24 (4) , e2300402
The Soft Nanodots as Fluorescent Probes for Cell Imaging: Analysis of Cell and Spheroid Penetration Behavior of Single Chain Polymer Dots
This study describes the formation, size control, and penetration behavior of polymer nanodots (Pdots) consisting of single or few chain polythiophene‐based conjugated polyelectrolytes (CPEs) via nanophase separation between good solvent and poor solvent of CPE. Though the chain singularity may be associated with dilution nanophase separation suggests that molecules of a good solvent create a thermodynamically driven solvation layer surrounding the CPEs and thereby separating the single chains even in their poor solvents. This statement is therefore corroborated with emission intensity/lifetime, particle size, and scattering intensity of polyelectrolyte in good and poor solvents. Regarding the augmented features, Pdots are implemented into cell imaging studies to understand the nuclear penetration and to differentiate the invasive characteristics of breast cancer cells. The python based red, green, blue (RGB) color analysis depicts that Pdots have more nuclear penetration ability in triple negative breast cancer cells due to the different nuclear morphology in shape and composition and Pdots have penetrated cell membrane as well as extracellular matrix in spheroid models. The current Pdot protocol and its utilization in cancer cell imaging are holding great promise for gene/drug delivery to target cancer cells by explicitly achieving the very first priority of nuclear intake.
- 10 January 2024
- Published by Wiley in Macromolecular Bioscience
- Vol. 24 (4) , e2300402
The Soft Nanodots as Fluorescent Probes for Cell Imaging: Analysis of Cell and Spheroid Penetration Behavior of Single Chain Polymer Dots
This study describes the formation, size control, and penetration behavior of polymer nanodots (Pdots) consisting of single or few chain polythiophene‐based conjugated polyelectrolytes (CPEs) via nanophase separation between good solvent and poor solvent of CPE. Though the chain singularity may be associated with dilution nanophase separation suggests that molecules of a good solvent create a thermodynamically driven solvation layer surrounding the CPEs and thereby separating the single chains even in their poor solvents. This statement is therefore corroborated with emission intensity/lifetime, particle size, and scattering intensity of polyelectrolyte in good and poor solvents. Regarding the augmented features, Pdots are implemented into cell imaging studies to understand the nuclear penetration and to differentiate the invasive characteristics of breast cancer cells. The python based red, green, blue (RGB) color analysis depicts that Pdots have more nuclear penetration ability in triple negative breast cancer cells due to the different nuclear morphology in shape and composition and Pdots have penetrated cell membrane as well as extracellular matrix in spheroid models. The current Pdot protocol and its utilization in cancer cell imaging are holding great promise for gene/drug delivery to target cancer cells by explicitly achieving the very first priority of nuclear intake.
- 23 February 2021
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 6 (3) , 950-957
PCR-Free Methodology for Detection of Single-Nucleotide Polymorphism with a Cationic Polythiophene Reporter
This study presents a nonamplification-based nucleic acid assay for the detection of single-nucleotide polymorphism (SNP) associated with familial Mediterranean fever (FMF) besides polymerase chain reaction (PCR)-based methodologies. The major objective is to show the potential of the proposed assay for rapid screening of FMF in a Mediterranean region of 400 million population. The assay relies on binding difference of specially designed wild and mutant primers to the target genomic DNA, followed by determination of unbound primers by quick titration of a cationic polythiophene reporter. The fluorescent reporter exhibits signal transition from 525 to 580 nm in the presence of unbound primers, and it correlates the binding affinity of label-free primers to the homozygous wild and mutant genomes. As a proof of concept, 26 real samples are studied relying on the ON and OFF fluorescence signals of the cationic polythiophene reporter. The results are analyzed by principal component analysis (PCA), which provides clear separation of healthy and patient individuals. The further analysis by support vector machine (SVM) classification has revealed that our assay converges to 96% overall accuracy. These results support that the PCR-free nucleic acid assay has a significant potential for rapid and cost-effective screening of familial Mediterranean fever.
- 23 February 2021
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 6 (3) , 950-957
PCR-Free Methodology for Detection of Single-Nucleotide Polymorphism with a Cationic Polythiophene Reporter
This study presents a nonamplification-based nucleic acid assay for the detection of single-nucleotide polymorphism (SNP) associated with familial Mediterranean fever (FMF) besides polymerase chain reaction (PCR)-based methodologies. The major objective is to show the potential of the proposed assay for rapid screening of FMF in a Mediterranean region of 400 million population. The assay relies on binding difference of specially designed wild and mutant primers to the target genomic DNA, followed by determination of unbound primers by quick titration of a cationic polythiophene reporter. The fluorescent reporter exhibits signal transition from 525 to 580 nm in the presence of unbound primers, and it correlates the binding affinity of label-free primers to the homozygous wild and mutant genomes. As a proof of concept, 26 real samples are studied relying on the ON and OFF fluorescence signals of the cationic polythiophene reporter. The results are analyzed by principal component analysis (PCA), which provides clear separation of healthy and patient individuals. The further analysis by support vector machine (SVM) classification has revealed that our assay converges to 96% overall accuracy. These results support that the PCR-free nucleic acid assay has a significant potential for rapid and cost-effective screening of familial Mediterranean fever.
- Open Access
Pixelated colorimetric nucleic acid assay
- 23 July 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (16) , 10357-10360
Single Chain Cationic Polymer Dot as a Fluorescent Probe for Cell Imaging and Selective Determination of Hepatocellular Carcinoma Cells
This letter describes formation of single chain cationic poly-mer dots (Pdots) made of poly[1,4-dimethyl-1-(3-((2,4,5-trimethylthiophen-3-yl)oxy)propyl)piperazin-1-ium bromide] conjugated polyelectrolyte (CPE). The single chain Pdots formation relies on a simple process which is a rapid nano-phase separation between CPE solution of ethylene glycol and water. Pdots show very narrow monodisperse size distribution with a 3.6 nm in diameter exhibiting high brightness, excellent colloidal and optical stability. We demonstrated that photoluminescent Pdots are providing selective nuclear translocation to the HCC cells as compared to healthy liver cells. The developed Pdot labeling effectively discriminates cancer cells in the co-culture media. Pdots are holding a great promise as a luminescent probe to diagnose cancer cells in histology and may guide surgeons during operations to precisely separate out cancerous tissue due to augmented fluorescence brightness.
- 23 July 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (16) , 10357-10360
Single Chain Cationic Polymer Dot as a Fluorescent Probe for Cell Imaging and Selective Determination of Hepatocellular Carcinoma Cells
This letter describes formation of single chain cationic poly-mer dots (Pdots) made of poly[1,4-dimethyl-1-(3-((2,4,5-trimethylthiophen-3-yl)oxy)propyl)piperazin-1-ium bromide] conjugated polyelectrolyte (CPE). The single chain Pdots formation relies on a simple process which is a rapid nano-phase separation between CPE solution of ethylene glycol and water. Pdots show very narrow monodisperse size distribution with a 3.6 nm in diameter exhibiting high brightness, excellent colloidal and optical stability. We demonstrated that photoluminescent Pdots are providing selective nuclear translocation to the HCC cells as compared to healthy liver cells. The developed Pdot labeling effectively discriminates cancer cells in the co-culture media. Pdots are holding a great promise as a luminescent probe to diagnose cancer cells in histology and may guide surgeons during operations to precisely separate out cancerous tissue due to augmented fluorescence brightness.
- 20 March 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (8) , 5122-5129
Hand-Held Volatilome Analyzer Based on Elastically Deformable Nanofibers
This study reports on a handheld volatilome analyzer for selective determination of clinically relevant biomarkers in exhaled breath. The sensing platform is based on electrospun polymer nanofiber-multi walled carbon nanotube (MWCNT) sensing micro-channels. Polymer nanofibers of poly(vinylidene fluoride) (PVDF), polystyrene (PS), and poly(methyl methacrylate) (PMMA) incorporated with MWCNT exhibits stable response to interferences of humidity and CO2 and provides selective deformations upon exposure of exhaled breath target volatilomes acetone and toluene, exhibiting correlation to diabetes and lung cancer, respectively. The sensing micro-channels “P1” (PVDF-MWCNT), “P2” (PS-MWCNT) and “P3” (PMMA-MWCNT) are integrated with a microfluidic cartridge (μ-card) that facilitates collection and concentration of exhaled breath. The volatilome analyzer consists of a conductivity monitoring unit, signal conditioning circuitries and a low energy display module. A combinatorial operation algorithm was developed for analyzing normalized resistivity changes of the sensing micro-channels upon exposure to breath in the concentration ranges between 35 ppb - 3.0 ppm for acetone and 1 ppb - 10 ppm for toluene. Subsequently, responses of volatilomes from individuals in the different risk groups of diabetes were evaluated for validation of the proposed methodology. We foresee that proposed methodology provides an avenue for rapid detection of volatilomes thereby enabling point of care diagnosis in high-risk group individuals.
- 20 March 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (8) , 5122-5129
Hand-Held Volatilome Analyzer Based on Elastically Deformable Nanofibers
This study reports on a handheld volatilome analyzer for selective determination of clinically relevant biomarkers in exhaled breath. The sensing platform is based on electrospun polymer nanofiber-multi walled carbon nanotube (MWCNT) sensing micro-channels. Polymer nanofibers of poly(vinylidene fluoride) (PVDF), polystyrene (PS), and poly(methyl methacrylate) (PMMA) incorporated with MWCNT exhibits stable response to interferences of humidity and CO2 and provides selective deformations upon exposure of exhaled breath target volatilomes acetone and toluene, exhibiting correlation to diabetes and lung cancer, respectively. The sensing micro-channels “P1” (PVDF-MWCNT), “P2” (PS-MWCNT) and “P3” (PMMA-MWCNT) are integrated with a microfluidic cartridge (μ-card) that facilitates collection and concentration of exhaled breath. The volatilome analyzer consists of a conductivity monitoring unit, signal conditioning circuitries and a low energy display module. A combinatorial operation algorithm was developed for analyzing normalized resistivity changes of the sensing micro-channels upon exposure to breath in the concentration ranges between 35 ppb - 3.0 ppm for acetone and 1 ppb - 10 ppm for toluene. Subsequently, responses of volatilomes from individuals in the different risk groups of diabetes were evaluated for validation of the proposed methodology. We foresee that proposed methodology provides an avenue for rapid detection of volatilomes thereby enabling point of care diagnosis in high-risk group individuals.