RTRóbert Tőtős

Róbert Tőtős

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Róbert Tőtős has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Real-Time Monitoring of Ibuprofen Release from Hydroxyapatite Using Conductivity Sensors

    by Ákos-Sándor Molnár, Réka Barabas, Róbert Tőtős

    Drug release monitoring from biomedical materials is essential for developing controlled delivery systems, particularly for localized pain management in applications such as orthopedic implants, dental implants, and bone scaffolds. Existing discrete sampling approaches provide limited temporal resolution and are labor-intensive, while continuous monitoring techniques, though capable of capturing complete release profiles, remain largely inaccessible due to the high cost of the required instrumentation. We developed a continuous, non-perturbative method for monitoring ibuprofen desorption from hydroxyapatite surfaces using a custom-built conductivity sensor system. The method exploited the dissolution of ibuprofen in a tris(hydroxymethyl)aminomethane/hydrochloride (TRIS/HCl) buffer medium (pH 7.4), where changes in solution conductivity directly correlate with ibuprofen concentration. Our approach utilized a low-cost sensor system based on Raspberry Pi 5 and Arduino Uno with an industrial-grade conductivity probe, together with open-source software, enabling real-time data acquisition and automated logging. The method was compared with UV-Vis spectroscopy, confirming that the conductivity-derived release profiles accurately reflect ibuprofen concentration over time. The system enabled continuous release profiles without sample removal, enabling observation of rapid initial desorption phases that may be missed by discrete sampling. This work established a cost-effective (approximately €400 total equipment cost), accessible method for characterizing drug release kinetics from hydroxyapatite and potentially other ionic and ionizable pharmaceutical compounds.

  • Open Access

    SYNTHESIS OF Pt(II)-COMPLEXES WITH SYMMETRICAL AND UNSYMMETRICAL GLYOXIMES, THEIR PHYSICAL-CHEMICAL AND BIOLOGICAL STUDY

    by Csaba Várhelyi Jr., Róbert Tötös, Melinda Simon-Várhelyi, Judit Papp, Judith Mihály, Raluca-Anca Mereu, Laura Marincas, János Madarász, György Pokol, Roland Szalay, et al.

    A series of Pt-complexes of the type [Pt(DioxH)2L2], (DioxH= deprotonated diethyl-glyoxime, methyl-pentyl-glyoxime, methyl-propyl-glioxime, L=amine) were synthesized, described and characterized with thermoanalytical (TG-DTG-DTA), spectroscopical (FTIR, ESI-MS, UV-VIS and NMR), powder XRD and AFM methods. The biological activity, especially the antibacterial effect, was also studied. The complexes were tested against selected Gram-positive and Gram-negative bacteria. The thermoanalytical measurements revealed the stability of complexes until 200 °C, which then loose characteristic fragments of their ligands. The spectroscopic data are in accordance with the thermal properties of the samples, confirming their composition. The compounds exhibited antibacterial effect against the bacterial strain studied.

  • Open Access

    Mössbauer study of some novel iron-bis-glyoxime and iron-tris-glyoxime complexes

    by Cs. Várhelyi, Z. Homonnay, R. Szalay, Gy. Pokol, I-M. Szilágyi, P. Huszthy, S. Kubuki, F. Goga, R. Tötös, M. Simon-Várhelyi, et al.

    Dioximes as ligands are used as analytical reagents and serve as models for biological systems as well as catalysts in chemical processes. A number of novel mixed complexes of the type [Fe(DioxH)2(amine)2] have been prepared and characterised by FTIR, 57Fe Mössbauer and mass spectroscopy by us. We have found strong Fe–N donor acceptor interactions and iron occurred in low-spin FeII state in all complexes. Later, we have also found that the incorporation of branching alkyl chains (isopropyl) in the complexes alters the Fe–N bond length and results in high-spin iron(II) state [1, 2]. The question arises: can the spin state of iron be manipulated generally by replacing the short alkyl chains with high volume demand ones in Fe-azomethine-amine complexes? To answer the question we have synthetized novel iron-bis-glioxime and iron-tris-gloxime complexes when long chain alkyl or aromatic ligands replaced the short alkyl ones and studied by 57Fe Mössbauer spectroscopy, MS, FTIR, UV-VIS, TG-DTA-DTG and XRD methods. Novel iron-bis-glyoxime and iron-tris-glyoxime type complexes, [Fe(Diethyl-Diox)3(BOH)2], [Fe(Diethyl-Diox)3(BOEt)2] and [Fe(phenyl-Me-Diox)3(BOEt)2], were synthesized similarly as described in [2]. The FTIR, UV-VIS, TG-DTA-DTG and MS measurements indicated that the expected novel complexes could be successfully synthesized.


  • Oscillations and collective behavior in convective flows

    by A. Gergely, Cs. Paizs, R. Tötös, Z. Néda

    Oscillations and collective behavior in convection-driven fluid columns are investigated and discussed in analogy with similar phenomenon observed for the flickering flames of candle bundles. Experimentally, it is shown that an ascending circular helium gas column performs an oscillation which is similar in several aspects to the oscillation of diffusion flames. Increasing the nozzle diameter leads to a decrease in the oscillation frequency, while increasing the flow rate results in an increase in this frequency. For helium columns oscillating at nearby frequency and placed close to each other, anti-phase synchronization and beating phenomena are observed. A toy-model based on elementary fluid dynamics describes the observed oscillations and leads to frequencies with the proper trend and values in the right order of magnitude.


  • Graphene Oxides/Carbon Nanotubes–Hydroxyapatite Nanocomposites for Biomedical Applications

    by Réka Barabás, Erick de Souza Ávila, Luiz Orlando Ladeira, Loudiana Mosqueira Antônio, Róbert Tötös, Dorina Simedru, Liliana Bizo, Oana Cadar


  • Open Access

    VALIDATED LC-MS/MS METHOD FOR THE DETERMINATION OF TADALAFIL – A COMPETITIVE PHOSPHODIESTERASE 5 INHIBITOR (PDE5) – FROM HUMAN PLASMA

    by Róbert Tőtős, József Balázsi

    The purpose of this study was the development and validation of an LC-MS/MS method, for the determination of tadalafil from human plasma. The sample workup involved a simple protein precipitation procedure. A core/shell type analytical column (50×2,1 mm, 2.6 Å) was used with C18 stationary phase. The mobile phase consisting of 30% acetonitril and 70% water provided good peak shape, accuracy and precision (stable ionization). The mass spectrometer was operated in positive electrospray ionization mode for analyte and internal standard. The following parameters were evaluated for validation purpose: selectivity, sensitivity, matrix effect, anticoagulant effect, linearity, precision and accuracy, recovery, short and long term analyte/IS stability in solvent/matrix and carryover. The validated calibration range was 22.2-1111.3 ng/ml. The correlation coefficient R2 was at least 0.9995 in all validation batches. The validated method has been successfully used for the evaluation of bioequivalence of generic tadalafil 20 mg formulations.


  • Open Access

    VALIDATED LC-MS/MS METHOD FOR THE DETERMINATION OF THE MUSCARINIC RECEPTOR ANTAGONIST (MRA) SOLIFENACIN FROM HUMAN PLASMA

    by Róbert Tőtős, József Balázsi

    The purpose of this study was the development and validation of an LC-MS/MS method, for the determination of solifenacin from human plasma. The sample workup involved a simple protein precipitation procedure. A core/shell type analytical column (50×2,1 mm, 2.6 Å) was used with C18 stationary phase. The mobile phase consisting of 65% acetonitril and 35% water provided good peak shape, accuracy and precision. The mass spectrometer was operated in positive electrospray ionization mode for analyte and internal standard. The following parameters were evaluated for validation purpose: Selectivity, sensitivity, matrix effect, anticoagulant effect, linearity, precision and accuracy, recovery, short and long term analyte/IS stability in solvent/matrix and carryover. The validated calibration range was 0.71-71.28 ng/ml. The correlation coefficient R2 was at least 0.99 in all validation batches. The validated method has been successfully used for the evaluation of bioequivalence of generic solifenacin 10 mg formulations.

  • Open Access

    HETEROCYCLES 50. SYNTHESIS AND CHARACTERIZATION OF NEW 2-PHENYLAMINOTHIAZOLE DERIVED MANNICH BASES BY BIOCATALYTIC MULTICOMPONENT REACTIONS

    by Denisa Leonte, Robert Tőtős, Valentin Zaharia

    In this work we describe the synthesis and characterization of new Mannich bases derived from 2-phenylaminothiazole, by applying the trimolecular condensation of thiazole aldehydes with aniline and acetone, catalyzed by lipase B from Candida antarctica. The target compounds were obtained with 68-76% yields, in mild and eco-friendly reaction conditions. The new heterocyclic Mannich bases were characterized by melting points, 1H NMR, 13C NMR and MS spectrometry.


  • Open Access

    VALIDATED LC-MS/MS METHOD FOR THE DETERMINATION OF THE NONSTEROIDAL ANTI-INFLAMMATORY DRUG (NSAID) DICLOFENAC FROM HUMAN PLASMA

    by Róbert Tőtős, József Balázsi

    The purpose of this study was the development and validation of an LC-MS/MS method, for the determination of diclofenac from human plasma. The sample workup involved a simple protein precipitation procedure. A core/shell type analytical column (50×2,1 mm, 2.6 Å) was used with C18 stationary phase. The mobile phase consisting of 52.5% acetonitrile and 47.5% water provided good peak shape, accuracy and precision (stable ionization). The mass spectrometer was operated in negative electrospray ionization mode for analyte and internal standard. The following parameters were evaluated for validation purpose: Selectivity, sensitivity, matrix effect, anticoagulant effect, linearity, precision and accuracy, recovery, short and long term analyte/IS stability in solvent/matrix and carryover. The validated calibration range was 3.9-1194 ng/ml. The correlation coefficient R2 was at least 0.999 in all validation batches. The validated method has been successfully used for the evaluation of bioequivalence of a generic diclofenac potassium formulation of 12.5 mg strength.

  • Open Access

    VALIDATED LC-MS/MS METHOD FOR THE CONCOMITANT DETERMINATION OF AMOXICILLIN AND CLAVULANIC ACID FROM HUMAN PLASMA

    by József Balázsi, Csaba Paizs, Florin-Dan Irimie, Monica Ioana Toşa, László Csaba Bencze, Róbert Tőtős

    The purpose of this study was the development and validation of an LC-MS/MS method, for the concomitant and rapid determination amoxicillin and clavulanic acid from human plasma. The sample workup involved a simple protein precipitation procedure. A core/shell type analytical column (50×2,1 mm, 2.6 Å) was used with PFP stationary phase. A mobile phase with high aqueous composition provided satisfactory separation with good accuracy and precision (stable ionization). The mass spectrometer was operated in positive electrospray ionization mode for both analytes and internal standard. The following parameters were evaluated for validation purpose: selectivity, sensitivity, matrix effect, anticoagulant effect, linearity, precision and accuracy, recovery, analyte/IS stability in solvent/matrix and carryover. The validated calibration range was 190-22222 ng/ml for amoxicillin, and 147-4908 ng/ml for clavulanic acid. The correlation coefficient R2 was at least 0.99 for both analytes. The validated method has been successfully used for the evaluation bioequivalence of generic amoxicillin/potassium clavulanate formulations.