SSSahil Sharma

Sahil Sharma

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sahil Sharma has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Premshankar Kumar Dubey

    Pressure, Vacuum and Ultrasonic Metrology, Division of Physico-Mechanical Metrology, CSIR-National Physical Laboratory, Dr. K. S. Krishnan Marg, New Delhi 110012, India

    3 shared publications
  • Sanjay Yadav

    Pressure, Vacuum and Ultrasonic Metrology, Division of Physico-Mechanical Metrology, CSIR-National Physical Laboratory, New Delhi, India

    2 shared publications
  • Arvind Kumar Saini

    Pressure, Vacuum and Ultrasonic Metrology, Division of Physico-Mechanical Metrology, CSIR-National Physical Laboratory, New Delhi, India

    1 shared publication
  • Bishan Kumar

    Pressure, Vacuum, and Ultrasonic Metrology, Division of Physico-Mechanical Metrology, CSIR-National Physical Laboratory, New Delhi, India

    1 shared publication
  • Blaise Yvert

    Univ. Grenoble Alpes Inserm U1216 Grenoble Institut Neurosciences, GIN Grenoble 38000 France

    1 shared publication
  • Bruno Fain

    Univ. Grenoble Alpes CEA LETI Grenoble F‐38000 France

    1 shared publication

Latest Publications

  • Open Access

    Development of sweep frequency ultrasonic interferometer for high precision velocity measurement in liquids

    by Nitin Dhiman, Sahil Sharma, Piyush, Bishan Kumar, Sanjay Yadav, P. K. Dubey

    An ultrasonic interferometer with variable separation between the transducer and reflector is widely used for the measurement of ultrasonic propagation velocity in liquids. The inherent limitation of such an interferometer is due to the mechanical movement of its reflector for ultrasonic wavelength measurement in a liquid medium. It is observed that the ultrasonic velocity measurement precision is adversely affected at higher frequencies compared to lower ones. For instance, in our experimentation, a standard deviation of ±21.5 m/s (±1.43%) was obtained for velocity measurement at 1.84 MHz with the consideration of two consecutive maxima, which increases drastically to ±76.8 m/s (±5.12%) at 9.4 MHz. These measurements can significantly be improved by considering many maxima and averaging for wavelength estimation. However, it still requires design attention and improvement, particularly for higher frequencies. In this article, a sweep-frequency based ultrasonic interferometer design with a fixed separation for liquid characterization is proposed and described. This technique overcomes the limitations of mechanical movement systems and also provides a better and uniform precision for lower as well as higher frequencies. The functionality of the developed sweep frequency method was tested in water, carbon tetrachloride, ethylene glycol, and glycerol, which shows good agreement with literature values. The velocity measurement in double distilled water by the developed technique at 1 Hz sweep resolution has shown an improved standard deviation of ±0.74 m/s (±0.05%) at 9.4 MHz.


  • Open Access

    Graphene Solution‐Gated Field‐Effect Transistor for Ultrasound‐Based Wireless and Battery‐Free Biosensing

    by Sahil Sharma, Carole‐Anne Lernoud, Bruno Fain, Riadh Othmen, Vincent Bouchiat, Blaise Yvert, Clément Hébert

    The development of wireless and battery‐free sensors for biomedical applications is a fast growing research and industrial field. It promises to greatly improve the patient's comfort during the diagnosis phase, but also in the treatment of chronic diseases. While the standard technologies are based so far on electromagnetic waves, ultrasonic powering and communication is offering perspectives to further reduce the size of the sensor in order to develop minimally invasive electronic implants. Wireless and battery‐free ultrasound‐based devices for healthcare monitoring comprise a piezoelectric element for the powering and communication, and a variable shunt load that varies according to a physiological parameter of interest. The changes in the load modify the acoustic reflectivity of the piezoelectric element, which can be detected using a pulse‐echo protocol. In the present study, the use of graphene solution‐gated field‐effect transistor is introduced as a new type of shunt load. Using an mm‐sized device, it is shown that the amplitude of an ultrasonic wave that reflects on the piezoelectric component is modulated by the voltage applied on the gate of the transistor both in physiological medium and biological tissue. This study sets the basis toward a new type of ultrasound‐based wireless and battery‐free biosensors.


  • Accuracy Estimation of Propagation Velocity in Variable Path Ultrasonic Interferometer for Liquids

    by Sahil Sharma, Ujjwal Kumar Mishra, Arvind Kumar Saini, P. K. Dubey


  • Improved ultrasonic interferometer technique for propagation velocity and attenuation measurement in liquids

    by Sahil Sharma, Ujjwal K. Mishra, Sanjay Yadav, P. K. Dubey

    Propagation velocity and attenuation are the two basic parameters used for the ultrasonic investigations of liquids. An ultrasonic interferometer is a widely used tool as a cost effective solution for propagation velocity measurement. The ultrasonic attenuation measurements are not possible using the existing interferometers commercially available in the market. Ultrasonic attenuation can be measured using the pulse echo method, which is relatively complex and expensive. Generally, in interferometers, a radio frequency voltage of more than 100 V is used to excite the piezoelectric transducer. In this article, an improved design of the ultrasonic interferometer with low (5 V) rf voltage excitation is discussed. The proposed design has several advantages over existing systems. The low voltage excitation reduces heating of the sample under study. Detection of the received signal is done directly at the transducer. The critical effects of a coaxial cable in rf detection are minimized by dc detection at the transducer node. The impedance response of the transducer is used for the detection of nodes and antinodes for attenuation and velocity measurements. The use of an instrumentation amplifier enables one to amplify the extremely small voltage changes across the transducer due to interference. The developed method has the capability to measure attenuation due to high receiver sensitivity. The technique has been validated for the propagation velocity and attenuation measurement in standard samples of water and other liquids. The results thus obtained have been compared with the literature and the conventional pulse echo technique which shows close agreement.