Heng Li

Heng Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Heng Li has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Transitioning from measurement-based to combined patient-specific quality assurance for intensity-modulated proton therapy

    by Mei Chen, Pablo Yepes, Yoshifumi Hojo, Falk Poenisch, Yupeng Li, Jiayi Chen, Cheng Xu, Xiaodong He, G.BRandon Gunn, Steven J. Frank, et al.

    Objective: This study is part of ongoing efforts aiming to transit from measurement-based to combined patient-specific quality assurance (PSQA) in intensity-modulated proton therapy (IMPT). A Monte Carlo (MC) dose-calculation algorithm is used to improve the independent dose calculation and to reveal the beam modeling deficiency of the analytical pencil beam (PB) algorithm. Methods: A set of representative clinical IMPT plans with suboptimal PSQA results were reviewed. Verification plans were recalculated using an MC algorithm developed in-house. Agreements of PB and MC calculations with measurements that quantified by the γ passing rate were compared. Results: The percentage of dose planes that met the clinical criteria for PSQA (>90% γ passing rate using 3%/3 mm criteria) increased from 71.40% in the original PB calculation to 95.14% in the MC recalculation. For fields without beam modifiers, nearly 100% of the dose planes exceeded the 95% γ passing rate threshold using the MC algorithm. The model deficiencies of the PB algorithm were found in the proximal and distal regions of the SOBP, where MC recalculation improved the γ passing rate by 11.27% (p < 0.001) and 16.80% (p < 0.001), respectively. Conclusions: The MC algorithm substantially improved the γ passing rate for IMPT PSQA. Improved modeling of beam modifiers would enable the use of the MC algorithm for independent dose calculation, completely replacing additional depth measurements in IMPT PSQA program. For current users of the PB algorithm, further improving the long-tail modeling or using MC simulation to generate the dose correction factor is necessary. Advances in knowledge: We justified a change in clinical practice to achieve efficient combined PSQA in IMPT by using the MC algorithm that was experimentally validated in almost all the clinical scenarios in our center. Deficiencies in beam modeling of the current PB algorithm were identified and solutions to improve its dose-calculation accuracy were provided.


  • Open Access

    Statistical evaluation of worst-case robust optimization intensity-modulated proton therapy plans using an exhaustive sampling approach

    by Zhiyong Yang, Heng Li, Yupeng Li, Yuting Li, Yu Chang, Qin Li, Kunyu Yang, Gang Wu, Narayan Sahoo, Falk Poenisch, et al.

    To assess the worst-case robust optimization IMPT plans with setup and range uncertainties and to test the hypothesis that the worst-case robust optimization strategies could cover most possible setup and range uncertainties in the real scenarios. We analyzed the nominal and worst-case robust optimization IMPT plans of seven patients with head and neck cancer patients. To take uncertainties into account for the dose calculation, we performed a comprehensive simulation in which the dose was recalculated 625 times per given plan using Gaussian systematic setup and proton range uncertainties. Subsequently, based on the simulation results, we calculated the target coverage in all perturbation scenarios, as well as the ratios of target coverage located within the threshold of eight worst-case scenarios. We set the criteria for the optimized plan to be the ratios of 1) the dose delivered to 95% (D95%) of clinical target volumes 1 and 2 (CTV1 and CTV2) above 95% of the prescribed dose, and 2) the D95% of clinical target volume 3 (CTV3) above 90% of the prescribed dose in worst-case situations. The probability that the perturbed-dose indices of the CTVs in each scenario were within the worst-case scenario limits ranged from 89.51 to 91.22% for both the nominal and worst-case robust optimization IMPT plans. A quartile analysis showed that the selective robust optimization IMPT plans all had higher D95% values for CTV1, CTV2, and CTV3 than did the nominal IMPT plans. The worst-case strategy for robust optimization is adequately models and covers most of the setup and range uncertainties for the IMPT treatment of head and neck patients in our center.