Stavros Vlatakis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Stavros Vlatakis has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Christin Henein
UCL Institute of Ophthalmology, London, United Kingdom
1 shared publication - Nkiruka Ibeanu
Optceutics Ltd., 28a Menelik Road, London NW2 3RP, UK
1 shared publication - Peng Tee Khaw
National Institute for Health and Care Research Biomedical Research Centre for Ophthalmology, University College London Institute of Ophthalmology & Moorfields Eye Hospital, London EC1V 9EL, UK
1 shared publication - Sahar Awwad
Optceutics Ltd., 28a Menelik Road, London NW2 3RP, UK
1 shared publication - Steve Brocchini
UCL School of Pharmacy, University College London, 29-39 Brunswick Square, London WC1N 1AX, UK
1 shared publication - Yann Bouremel
Optceutics Ltd., 28a Menelik Road, London NW2 3RP, UK
1 shared publication
Latest Publications
- Open Access
- 1 August 2019
- Published by MDPI AG in Pharmaceutics
- Vol. 11 (8) , 371
Hydrodynamics of Intravitreal Injections into Liquid Vitreous Substitutes
Intravitreal injections have become the cornerstone of retinal care and one of the most commonly performed procedures across all medical specialties. The impact of hydrodynamic forces of intravitreal solutions when injected into vitreous or vitreous substitutes has not been well described. While computational models do exist, they tend to underestimate the starting surface area of an injected bolus of a drug. Here, we report the dispersion profile of a dye bolus (50 µL) injected into different vitreous substitutes of varying viscosities, surface tensions, and volumetric densities. A novel 3D printed in vitro model of the vitreous cavity of the eye was designed to visualize the dispersion profile of solutions when injected into the following vitreous substitutes—balanced salt solution (BSS), sodium hyaluronate (HA), and silicone oils (SO)—using a 30G needle with a Reynolds number (Re) for injection ranging from approximately 189 to 677. Larger bolus surface areas were associated with faster injection speeds, lower viscosity of vitreous substitutes, and smaller difference in interfacial surface tensions. Boluses exhibited buoyancy when injected into standard S1000. The hydrodynamic properties of liquid vitreous substitutes influence the initial injected bolus dispersion profile and should be taken into account when simulating drug dispersion following intravitreal injection at a preclinical stage of development, to better inform formulations and performance.
- 1 August 2019
- Published by MDPI AG in Pharmaceutics
- Vol. 11 (8) , 371
Open AccessHydrodynamics of Intravitreal Injections into Liquid Vitreous Substitutes
Intravitreal injections have become the cornerstone of retinal care and one of the most commonly performed procedures across all medical specialties. The impact of hydrodynamic forces of intravitreal solutions when injected into vitreous or vitreous substitutes has not been well described. While computational models do exist, they tend to underestimate the starting surface area of an injected bolus of a drug. Here, we report the dispersion profile of a dye bolus (50 µL) injected into different vitreous substitutes of varying viscosities, surface tensions, and volumetric densities. A novel 3D printed in vitro model of the vitreous cavity of the eye was designed to visualize the dispersion profile of solutions when injected into the following vitreous substitutes—balanced salt solution (BSS), sodium hyaluronate (HA), and silicone oils (SO)—using a 30G needle with a Reynolds number (Re) for injection ranging from approximately 189 to 677. Larger bolus surface areas were associated with faster injection speeds, lower viscosity of vitreous substitutes, and smaller difference in interfacial surface tensions. Boluses exhibited buoyancy when injected into standard S1000. The hydrodynamic properties of liquid vitreous substitutes influence the initial injected bolus dispersion profile and should be taken into account when simulating drug dispersion following intravitreal injection at a preclinical stage of development, to better inform formulations and performance.