Yifei Luo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yifei Luo has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Fei Xiao
Naval University of Engineering
9 shared publications - Binli Liu
Naval University of Engineering
8 shared publications - Zenan Shi
State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
6 shared publications - Tongyao Han
National Key Laboratory of Electromagnetic Energy, Naval University of Engineering, Wuhan, China
5 shared publications - Feng Xie
National Key Laboratory of Electromagnetic Energy, Naval University of Engineering, Wuhan, China
4 shared publications - Xin Li
Naval University of Engineering
4 shared publications
Latest Publications
- 17 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (2) , 1583-1599
Refined Modeling and Online Fault Diagnosis Method for Open-Circuit Faults in Dual-Active-Bridge Converters
The dual active bridge (DAB) converter is a popular DC–DC converter topology for high-power applications. An open-circuit fault (OCF) in DAB converter can produce a DC bias in its transformer currents, which can saturate the transformer, resulting in significant power losses and power quality deterioration. In this paper, a refined modeling and an online OCF diagnosis method are proposed for OCF in DAB converters. Firstly, the causes of voltage and current waveform distortion caused by OCF are analyzed in detail. The reasons for differences in transformer voltage and current waveforms due to different OCF positions are studied. The importance of critical parameters such as the magnetizing inductance of transformers and parasitic capacitance of power switches to analysis of circuit operation characteristics under OCF conditions is clarified. Based on this theoretical research, a refined DAB converter modeling incorporating critical parameters is proposed. In contrast to current models, this proposed model offers improved accuracy in depicting variations of primary-side electrical parameters under OCF conditions. Additionally, an OCF diagnosis method is proposed. This method utilizes the cycle-average value of the transformer primary-side current for OCF detection and localization. Unlike prior methods, the proposed method does not necessitate supplementary hardware sensing conditions, nor does it require the converter to operate in a specific switching state. Finally, the online deployment of OCF diagnosis method based on FPGA is completed. Experimental results verify that the proposed model effectively simulates variations in the primary-side and secondary-side currents of the transformer, as well as the magnetizing current, under OCF conditions. As a fault feature, the mean absolute error (MAE) of the primary-side current is within 0.5A and the period average error is within 0.2%. Moreover, the online OCF diagnosis method enables OCF detection within 1 switching cycle and OCF localization within 6 switching cycles.
- 17 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (2) , 1583-1599
Refined Modeling and Online Fault Diagnosis Method for Open-Circuit Faults in Dual-Active-Bridge Converters
The dual active bridge (DAB) converter is a popular DC–DC converter topology for high-power applications. An open-circuit fault (OCF) in DAB converter can produce a DC bias in its transformer currents, which can saturate the transformer, resulting in significant power losses and power quality deterioration. In this paper, a refined modeling and an online OCF diagnosis method are proposed for OCF in DAB converters. Firstly, the causes of voltage and current waveform distortion caused by OCF are analyzed in detail. The reasons for differences in transformer voltage and current waveforms due to different OCF positions are studied. The importance of critical parameters such as the magnetizing inductance of transformers and parasitic capacitance of power switches to analysis of circuit operation characteristics under OCF conditions is clarified. Based on this theoretical research, a refined DAB converter modeling incorporating critical parameters is proposed. In contrast to current models, this proposed model offers improved accuracy in depicting variations of primary-side electrical parameters under OCF conditions. Additionally, an OCF diagnosis method is proposed. This method utilizes the cycle-average value of the transformer primary-side current for OCF detection and localization. Unlike prior methods, the proposed method does not necessitate supplementary hardware sensing conditions, nor does it require the converter to operate in a specific switching state. Finally, the online deployment of OCF diagnosis method based on FPGA is completed. Experimental results verify that the proposed model effectively simulates variations in the primary-side and secondary-side currents of the transformer, as well as the magnetizing current, under OCF conditions. As a fault feature, the mean absolute error (MAE) of the primary-side current is within 0.5A and the period average error is within 0.2%. Moreover, the online OCF diagnosis method enables OCF detection within 1 switching cycle and OCF localization within 6 switching cycles.
- 3 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (6) , 6828-6839
Thermal Balance-Based Evaluation Method for Safe Operating Areas and Its Degradation of IGBT Power Module
Insulated gate bipolar transistors (IGBTs) power module experience significant thermal stress during short-time overload conditions, and their electro-thermal characteristics exhibit strong nonlinearities. As a result, the two-dimensional safe operating area (SOA) provided in the datasheet is unable to meet the need of device reliability assessments. In this paper, we propose a quantitative assessment method based on the thermal balance principle to define the SOA for IGBTs and assess its degradation. A three-dimensional SOA that incorporates voltage, current, and junction temperature is established to prevent IGBT from thermal failures. The proposed SOA indicates that IGBT can operate safely at more than twice the rated current, and the junction temperature can exceed 448.15K(175° C) without thermal failures. This work provides theoretical support for IGBT application design and reliability assessment. According to the physical mechanisms associated with thermal failures of IGBT power module, a criterion to characterize the thermal instability of devices is established. Further, the net heat flux analysis model that integrates semiconductor physics with heat conduction theory is established, enabling the formulation of the three-dimensional SOA of IGBT. Moreover, the effects of the degradation of electro-thermal characteristics on the SOA throughout the long-term operation of the device is considered. In addition, an electro-thermal coupling model that simulates the electro-thermal characteristics of the device is established. The results from both simulation and experiment demonstrate that the established SOA and its degradation effectively predict the reliability of the IGBT under short-time overload conditions.
- 3 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (6) , 6828-6839
Thermal Balance-Based Evaluation Method for Safe Operating Areas and Its Degradation of IGBT Power Module
Insulated gate bipolar transistors (IGBTs) power module experience significant thermal stress during short-time overload conditions, and their electro-thermal characteristics exhibit strong nonlinearities. As a result, the two-dimensional safe operating area (SOA) provided in the datasheet is unable to meet the need of device reliability assessments. In this paper, we propose a quantitative assessment method based on the thermal balance principle to define the SOA for IGBTs and assess its degradation. A three-dimensional SOA that incorporates voltage, current, and junction temperature is established to prevent IGBT from thermal failures. The proposed SOA indicates that IGBT can operate safely at more than twice the rated current, and the junction temperature can exceed 448.15K(175° C) without thermal failures. This work provides theoretical support for IGBT application design and reliability assessment. According to the physical mechanisms associated with thermal failures of IGBT power module, a criterion to characterize the thermal instability of devices is established. Further, the net heat flux analysis model that integrates semiconductor physics with heat conduction theory is established, enabling the formulation of the three-dimensional SOA of IGBT. Moreover, the effects of the degradation of electro-thermal characteristics on the SOA throughout the long-term operation of the device is considered. In addition, an electro-thermal coupling model that simulates the electro-thermal characteristics of the device is established. The results from both simulation and experiment demonstrate that the established SOA and its degradation effectively predict the reliability of the IGBT under short-time overload conditions.
- 24 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (6) , 5544-5557
Degradation State Assessment of IGBT Module Based on Interpretable LSTM-AE Modeling Under Changing Working Conditions
Researches indicate that the Insulated Gate Bipolar Transistor (IGBT) module is a crucial yet failure-prone constituent of power electronic devices. As a result, assessing the degradation state of IGBT module is significant to guarantee safe device operation. However, existing studies are usually conducted under constant working conditions, which is inconsistent with the strong nonlinearity of the degradation process and strong coupling of parameters of the IGBT module caused by changing working conditions. Additionally, the designed models often lack interpretability, making it less credible. Some of them may even need to be processed with the full life data after the degradation state is obtained, which does not satisfy the requirements of online applications. Therefore, this paper proposes an interpretable LSTM-AE modeling method for degradation state assessment of IGBT modules under changing working conditions. Firstly, the interpretability of the model is improved by designing a contrastive output structure. Then, by analyzing the characteristics of IGBT module degradation process, the properties of the degradation are summarized, and the prior knowledge is integrated into the model as a constraint to enhance the accuracy of the degradation state assessment and further improve the interpretability. Afterwards, a variable working condition power cycle experiment system is designed and constructed to collect degradation data. Finally, the performance of the proposed method is verified. The results show that the degradation state extracted by the proposed method are more consistent with the theoretical analysis results, which can accurately assess the degradation state of IGBT modules.
- 24 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (6) , 5544-5557
Degradation State Assessment of IGBT Module Based on Interpretable LSTM-AE Modeling Under Changing Working Conditions
Researches indicate that the Insulated Gate Bipolar Transistor (IGBT) module is a crucial yet failure-prone constituent of power electronic devices. As a result, assessing the degradation state of IGBT module is significant to guarantee safe device operation. However, existing studies are usually conducted under constant working conditions, which is inconsistent with the strong nonlinearity of the degradation process and strong coupling of parameters of the IGBT module caused by changing working conditions. Additionally, the designed models often lack interpretability, making it less credible. Some of them may even need to be processed with the full life data after the degradation state is obtained, which does not satisfy the requirements of online applications. Therefore, this paper proposes an interpretable LSTM-AE modeling method for degradation state assessment of IGBT modules under changing working conditions. Firstly, the interpretability of the model is improved by designing a contrastive output structure. Then, by analyzing the characteristics of IGBT module degradation process, the properties of the degradation are summarized, and the prior knowledge is integrated into the model as a constraint to enhance the accuracy of the degradation state assessment and further improve the interpretability. Afterwards, a variable working condition power cycle experiment system is designed and constructed to collect degradation data. Finally, the performance of the proposed method is verified. The results show that the degradation state extracted by the proposed method are more consistent with the theoretical analysis results, which can accurately assess the degradation state of IGBT modules.
- 20 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (4) , 4178-4190
Parameter Correction Method of Vce(on)-Based Junction Temperature Estimation Model Based on Bonding Wire Fatigue
The junction temperature ( T j ) obtained by the V ce(on) -based junction temperature estimation model under high current, the accuracy of which depends on the output characteristics curve of the IGBT modules. However, there is a significant increase in the conduction voltage drop V ce(on) throughout the fatigue degradation process. As a result, substantial errors occur in the T j obtained through the traditional V ce(on) -based junction temperature estimation model. Under high current, lifting-off of bonding wires emerges as the primary fatigue mode. In this article, therefore, the crack propagation behavior at the bonding nodes is thoroughly analyzed based on the bonding wire lift-off fatigue mechanism, and an equivalent resistance degradation model is established. Ultimately, a V ce(on) -based T j estimation model that considers the degradation is selected before correcting the output characteristic curve of the fatigue-degraded modules. This model effectively considers the offset in the curve caused by the degradation, thus realizing online T j monitoring after long-term fatigue. An experimental system has been set up, demonstrating that the error between the T j obtained from the corrected model and the actual T j does not exceed 2%. The method proposed in this paper can diminish the error by more than 30% compared to the uncorrected model.
- 20 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (4) , 4178-4190
Parameter Correction Method of Vce(on)-Based Junction Temperature Estimation Model Based on Bonding Wire Fatigue
The junction temperature ( T j ) obtained by the V ce(on) -based junction temperature estimation model under high current, the accuracy of which depends on the output characteristics curve of the IGBT modules. However, there is a significant increase in the conduction voltage drop V ce(on) throughout the fatigue degradation process. As a result, substantial errors occur in the T j obtained through the traditional V ce(on) -based junction temperature estimation model. Under high current, lifting-off of bonding wires emerges as the primary fatigue mode. In this article, therefore, the crack propagation behavior at the bonding nodes is thoroughly analyzed based on the bonding wire lift-off fatigue mechanism, and an equivalent resistance degradation model is established. Ultimately, a V ce(on) -based T j estimation model that considers the degradation is selected before correcting the output characteristic curve of the fatigue-degraded modules. This model effectively considers the offset in the curve caused by the degradation, thus realizing online T j monitoring after long-term fatigue. An experimental system has been set up, demonstrating that the error between the T j obtained from the corrected model and the actual T j does not exceed 2%. The method proposed in this paper can diminish the error by more than 30% compared to the uncorrected model.
- 1 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
Online Open-Circuit Fault Diagnosis for Neutral Point Clamped Inverter Based on an Improved Convolutional Neural Network and Sample Amplification Method Under Varying Operating Conditions
The accuracy of data-driven open-circuit fault diagnosis methods is affected by varying operating conditions. This issue is often ignored. In this paper, an improved convolutional neural network (CNN) and a sample amplification method are proposed to eliminate the influence of varying operating conditions on the online open-circuit fault (OCF) diagnosis for neutral point clamped (NPC) inverter. Firstly, 73 types of open-circuit fault sample collection can be greatly reduced to 14 by following the sample amplification method. The signals of any phase can be generated by a single fundamental period signal. This provides a significant savings in sample collection time. Secondly, the spatial attention mechanism (SAM) is added after the first convolutional layer of the CNN model. The feature extraction capability of the model is enhanced for time-domain waveform scaling under variable operating conditions. Simultaneously, the last full connection (FC) layer of the CNN model is retained and the other FC layers are substituted with a global maximum pooling (GMP) layer. This has the advantage of reducing the number of network parameters and further conserving the effective feature information. In conclusion, the experimental results show that the sample amplification method and the improved CNN model for online fault diagnosis under varying operating conditions exceed 99% accuracy. The SAMCNN-GMP is more effective and stable than the CNN model.
- 1 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
Online Open-Circuit Fault Diagnosis for Neutral Point Clamped Inverter Based on an Improved Convolutional Neural Network and Sample Amplification Method Under Varying Operating Conditions
The accuracy of data-driven open-circuit fault diagnosis methods is affected by varying operating conditions. This issue is often ignored. In this paper, an improved convolutional neural network (CNN) and a sample amplification method are proposed to eliminate the influence of varying operating conditions on the online open-circuit fault (OCF) diagnosis for neutral point clamped (NPC) inverter. Firstly, 73 types of open-circuit fault sample collection can be greatly reduced to 14 by following the sample amplification method. The signals of any phase can be generated by a single fundamental period signal. This provides a significant savings in sample collection time. Secondly, the spatial attention mechanism (SAM) is added after the first convolutional layer of the CNN model. The feature extraction capability of the model is enhanced for time-domain waveform scaling under variable operating conditions. Simultaneously, the last full connection (FC) layer of the CNN model is retained and the other FC layers are substituted with a global maximum pooling (GMP) layer. This has the advantage of reducing the number of network parameters and further conserving the effective feature information. In conclusion, the experimental results show that the sample amplification method and the improved CNN model for online fault diagnosis under varying operating conditions exceed 99% accuracy. The SAMCNN-GMP is more effective and stable than the CNN model.
- 18 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 11 (6) , 6054-6067
Online Diagnosis Method for Open-Circuit Fault of NPC Inverter Based on 1D-DSCNN-GMP Lightweight Edge Deployment
Due to the open-circuit fault of neutral point clamped (NPC) inverter having the characteristics of solid concealment and multiple fault modes, it is necessary to study an accurate and efficient fault diagnosis method to detect and locate the fault in time. However, the existing methods are either based on artificial analytical modeling or signal analysis, which is challenging to model and needs better portability or the model needs to be simplified to implement online applications. Therefore, this paper proposes a data-driven fault diagnosis and high-performance online inference method. The diagnosis method simplifies the traditional labeling method by designing labels and takes one-dimensional depth separable convolution (1D-DSC) and global max pooling (GMP) to replace conventional one-dimensional convolution and local pooling called 1D-DSCNN-GMP. Then, the model is compressed and optimized based on the TensorRT framework. Experiments show that compared with the existing methods, the proposed method can reduce the number of model parameters by more than 90%. The average online inference time of the model after compression and deployment to the Edge Computing Board (ECB) is about 1 ms, only 5% fundamental period, and can maintain 100% diagnostic accuracy, with better online application potential.
- 18 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 11 (6) , 6054-6067
Online Diagnosis Method for Open-Circuit Fault of NPC Inverter Based on 1D-DSCNN-GMP Lightweight Edge Deployment
Due to the open-circuit fault of neutral point clamped (NPC) inverter having the characteristics of solid concealment and multiple fault modes, it is necessary to study an accurate and efficient fault diagnosis method to detect and locate the fault in time. However, the existing methods are either based on artificial analytical modeling or signal analysis, which is challenging to model and needs better portability or the model needs to be simplified to implement online applications. Therefore, this paper proposes a data-driven fault diagnosis and high-performance online inference method. The diagnosis method simplifies the traditional labeling method by designing labels and takes one-dimensional depth separable convolution (1D-DSC) and global max pooling (GMP) to replace conventional one-dimensional convolution and local pooling called 1D-DSCNN-GMP. Then, the model is compressed and optimized based on the TensorRT framework. Experiments show that compared with the existing methods, the proposed method can reduce the number of model parameters by more than 90%. The average online inference time of the model after compression and deployment to the Edge Computing Board (ECB) is about 1 ms, only 5% fundamental period, and can maintain 100% diagnostic accuracy, with better online application potential.
- 6 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (3) , 3200-3216
An Integrated Digital Signal Feedback Sensor for Fast Transient Measurements of SiC-MOSFET Modules
This paper proposes a digital signal feedback sensor design method for SiC MOSFET modules to be used in active gate drivers in the future. This real-time detection method provides high bandwidth, high integrated density and low latency in transient measurements. In this paper, novel solutions are developed to address the shortcomings of the current research. Firstly, the boundary conditions for non-isolated voltage measurement of ${V_{DS}}$ and ${V_{KS}}$ in SiC-MOSFET modules are established. Secondly, the delay time of each state variable is specified for digital real-time detection. Thirdly, the effect of temperature on parasitic resistance is analyzed during transients and ${I_{D}}$ is calculated in real-time using a correction filter algorithm. For verification, a digital signal feedback sensor was applied to a double pulse circuit. The results show a high integrated density of up to ${1.3kA/{inch}^{3}}$ and ${6.7kV/{inch}^{3}}$ while achieving a bandwidth of more than ${20MHz}$ . The relative error of measuring ${V_{DS}}$ , ${dV_{DS}/dt}$ , ${dI_{D}/dt}$ , and ${I_{D}}$ is within ${2\%}$ , ${5\%}$ , ${9\%}$ , and ${6\%}$ . In addition, the fastest transition time of the state variables is only ${13ns}$ . In summary, this design provides an engineering reference and theoretical basis for the implementation of a digital feedback active gate driver.
- 6 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (3) , 3200-3216
An Integrated Digital Signal Feedback Sensor for Fast Transient Measurements of SiC-MOSFET Modules
This paper proposes a digital signal feedback sensor design method for SiC MOSFET modules to be used in active gate drivers in the future. This real-time detection method provides high bandwidth, high integrated density and low latency in transient measurements. In this paper, novel solutions are developed to address the shortcomings of the current research. Firstly, the boundary conditions for non-isolated voltage measurement of ${V_{DS}}$ and ${V_{KS}}$ in SiC-MOSFET modules are established. Secondly, the delay time of each state variable is specified for digital real-time detection. Thirdly, the effect of temperature on parasitic resistance is analyzed during transients and ${I_{D}}$ is calculated in real-time using a correction filter algorithm. For verification, a digital signal feedback sensor was applied to a double pulse circuit. The results show a high integrated density of up to ${1.3kA/{inch}^{3}}$ and ${6.7kV/{inch}^{3}}$ while achieving a bandwidth of more than ${20MHz}$ . The relative error of measuring ${V_{DS}}$ , ${dV_{DS}/dt}$ , ${dI_{D}/dt}$ , and ${I_{D}}$ is within ${2\%}$ , ${5\%}$ , ${9\%}$ , and ${6\%}$ . In addition, the fastest transition time of the state variables is only ${13ns}$ . In summary, this design provides an engineering reference and theoretical basis for the implementation of a digital feedback active gate driver.
- 6 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (7) , 7030-7041
A Passive Voltage-Balancing Method for Series-Connected SiC MOSFETs in Pulse Generator Based on Snubber Circuit
High-voltage nanosecond pulse generators based on series-connected silicon carbide (SiC) mosfet s have many prospects in industrial applications. However, the traditional pulse generators cannot achieve voltage sharing and fast pulse rise speed at the same time, which has become one of the key issues limiting the development of generators in some applications. In this article, a novel passive snubber method base on voltage-balancing capacitors is proposed to tackle this issue. First, an analytical model of the pulse rise time of the generator is proposed based on the switching physical principles of the SiC mosfet . Then, a physics-based dynamic voltage-unbalancing model of the series-connected SiC mosfet s in the pulse generator is established. Furthermore, based on the established pulse rise model and voltage-unbalancing model of the series-connected SiC mosfet s, a voltage-balancing method is proposed which can be used to design optimal voltage-balancing capacitors. Finally, experiments are carried out on a ±5 kV nanosecond-pulse generator. The voltage imbalance ratio of series-connected devices is less than 3.1% and pulse rise time is less than 45.8 ns under different operation conditions, which verify the effectiveness and feasibility of the proposed method.
- 6 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (7) , 7030-7041
A Passive Voltage-Balancing Method for Series-Connected SiC MOSFETs in Pulse Generator Based on Snubber Circuit
High-voltage nanosecond pulse generators based on series-connected silicon carbide (SiC) mosfet s have many prospects in industrial applications. However, the traditional pulse generators cannot achieve voltage sharing and fast pulse rise speed at the same time, which has become one of the key issues limiting the development of generators in some applications. In this article, a novel passive snubber method base on voltage-balancing capacitors is proposed to tackle this issue. First, an analytical model of the pulse rise time of the generator is proposed based on the switching physical principles of the SiC mosfet . Then, a physics-based dynamic voltage-unbalancing model of the series-connected SiC mosfet s in the pulse generator is established. Furthermore, based on the established pulse rise model and voltage-unbalancing model of the series-connected SiC mosfet s, a voltage-balancing method is proposed which can be used to design optimal voltage-balancing capacitors. Finally, experiments are carried out on a ±5 kV nanosecond-pulse generator. The voltage imbalance ratio of series-connected devices is less than 3.1% and pulse rise time is less than 45.8 ns under different operation conditions, which verify the effectiveness and feasibility of the proposed method.
- 21 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 11 (5) , 5405-5416
A Reduced-Order Decoupling Method Applied to Efficient Junction Temperature Simulation Model in Multichip Devices
As the power density of power modules increases, the cross-heating effects in multichip modules become severe, which intensifies the local overheating stress. To accurately predict the dynamic thermal characteristics of the multichip modules, this paper establishes the mathematical relationship between the resistance-capacitance (RC) parameters and the thermal diffusion angle to obtain accurate RC parameters. The decoupling of the self-heating and cross-heating effects is realized according to the dynamic power flow in the RC thermal network, reducing the transient thermal impedance matrix to the steady-state thermal resistance matrix. In this way, the 3-D cross-heating effect on the junction temperature is characterized by the 1-D RC thermal network. Then, an efficient junction temperature simulation model based on the reduced-order decoupling method is proposed. This article also identifies the variation law of RC parameters with boundary conditions. Compared with existing models that need transient information, the model parameter extraction process requires only the steady-state information of the finite element method (FEM) and fewer RC parameters, which improves the parameter extraction efficiency by more than 87 times. In addition, compared with the FEM model, the transient junction temperature prediction efficiency is improved by more than 994 times. Finally, based on a 1200V/50A half-bridge module, an electrothermal coupling model is constructed and applied to a three-phase two-stage inverter circuit. The results verify the accuracy and effectiveness of the proposed model, demonstrating that the junction temperature error between the proposed model and the experimental result is less than 5%.
- 21 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 11 (5) , 5405-5416
A Reduced-Order Decoupling Method Applied to Efficient Junction Temperature Simulation Model in Multichip Devices
As the power density of power modules increases, the cross-heating effects in multichip modules become severe, which intensifies the local overheating stress. To accurately predict the dynamic thermal characteristics of the multichip modules, this paper establishes the mathematical relationship between the resistance-capacitance (RC) parameters and the thermal diffusion angle to obtain accurate RC parameters. The decoupling of the self-heating and cross-heating effects is realized according to the dynamic power flow in the RC thermal network, reducing the transient thermal impedance matrix to the steady-state thermal resistance matrix. In this way, the 3-D cross-heating effect on the junction temperature is characterized by the 1-D RC thermal network. Then, an efficient junction temperature simulation model based on the reduced-order decoupling method is proposed. This article also identifies the variation law of RC parameters with boundary conditions. Compared with existing models that need transient information, the model parameter extraction process requires only the steady-state information of the finite element method (FEM) and fewer RC parameters, which improves the parameter extraction efficiency by more than 87 times. In addition, compared with the FEM model, the transient junction temperature prediction efficiency is improved by more than 994 times. Finally, based on a 1200V/50A half-bridge module, an electrothermal coupling model is constructed and applied to a three-phase two-stage inverter circuit. The results verify the accuracy and effectiveness of the proposed model, demonstrating that the junction temperature error between the proposed model and the experimental result is less than 5%.
- Open Access
Short-Duration Transient Temperature Distribution Prediction Model along Chip Vertical Path Applicable to Multi-Timescale Simulation
Based on extremely uneven temperature distribution along the insulated gate bipolar transistor (IGBT) chip vertical path during switching transients, a short-duration transient microsecond-scale prediction model applicable to multi-timescale simulation is presented in this paper. Traditional thermal models often take the chip active area as a uniform heat source to obtain a victual junction temperature (Tvj). In this paper, a discrete distributed heat source model combined with a thermal network model based on the sublayer division strategy is proposed to achieve an accurate temperature distribution description along the chip vertical path. Taking a 1700 V/3600 A IGBT module as an example, the proposed model can evaluate the short-duration transient temperature distribution along the chip vertical path and the error is less than 2 °C compared with the finite element model. Meanwhile, the model is applied to a single short-duration transient timescale and multi-timescale systems separately, and the simulation speed is increased by more than 80 times and 297 times, which verifies its validity and accuracy.
Open AccessShort-Duration Transient Temperature Distribution Prediction Model along Chip Vertical Path Applicable to Multi-Timescale Simulation
Based on extremely uneven temperature distribution along the insulated gate bipolar transistor (IGBT) chip vertical path during switching transients, a short-duration transient microsecond-scale prediction model applicable to multi-timescale simulation is presented in this paper. Traditional thermal models often take the chip active area as a uniform heat source to obtain a victual junction temperature (Tvj). In this paper, a discrete distributed heat source model combined with a thermal network model based on the sublayer division strategy is proposed to achieve an accurate temperature distribution description along the chip vertical path. Taking a 1700 V/3600 A IGBT module as an example, the proposed model can evaluate the short-duration transient temperature distribution along the chip vertical path and the error is less than 2 °C compared with the finite element model. Meanwhile, the model is applied to a single short-duration transient timescale and multi-timescale systems separately, and the simulation speed is increased by more than 80 times and 297 times, which verifies its validity and accuracy.