Susumu Katsushika
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Susumu Katsushika has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Hiroshi Akazawa
Department of Cardiovascular Medicine, The University of Tokyo Hospital , 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655 , Japan
3 shared publicationsHiroyuki Morita
Department of Cardiovascular Medicine, The University of Tokyo Hospital , 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655 , Japan
3 shared publicationsKatsuhito Fujiu
Department of Advanced Cardiology, The University of Tokyo , 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655 , Japan
3 shared publications- Satoshi Kodera
Department of Cardiovascular Medicine The University of Tokyo Hospital Tokyo Japan
3 shared publications Yasutomi Higashikuni
Department of Cardiovascular Medicine, The University of Tokyo Hospital , 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655 , Japan
3 shared publicationsHiroki Shinohara
Department of Cardiovascular Medicine, The University of Tokyo Hospital , 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655 , Japan
2 shared publications
Latest Publications
- Open Access
- 17 April 2023
- Published by Oxford University Press (OUP) in European Heart Journal - Digital Health
- Vol. 4 (3) , 254-264
An explainable artificial intelligence-enabled electrocardiogram analysis model for the classification of reduced left ventricular function
Aims: The black box nature of artificial intelligence (AI) hinders the development of interpretable AI models that are applicable in clinical practice. We aimed to develop an AI model for classifying patients of reduced left ventricular ejection fraction (LVEF) from 12-lead electrocardiograms (ECG) with the decision-interpretability. Methods and results: We acquired paired ECG and echocardiography datasets from the central and co-operative institutions. For the central institution dataset, a random forest model was trained to identify patients with reduced LVEF among 29 907 ECGs. Shapley additive explanations were applied to 7196 ECGs. To extract the model’s decision criteria, the calculated Shapley additive explanations values were clustered for 192 non-paced rhythm patients in which reduced LVEF was predicted. Although the extracted criteria were different for each cluster, these criteria generally comprised a combination of six ECG findings: negative T-wave inversion in I/V5–6 leads, low voltage in I/II/V4–6 leads, Q wave in V3–6 leads, ventricular activation time prolongation in I/V5–6 leads, S-wave prolongation in V2–3 leads, and corrected QT interval prolongation. Similarly, for the co-operative institution dataset, the extracted criteria comprised a combination of the same six ECG findings. Furthermore, the accuracy of seven cardiologists’ ECG readings improved significantly after watching a video explaining the interpretation of these criteria (before, 62.9% ± 3.9% vs. after, 73.9% ± 2.4%; P = 0.02). Conclusion: We visually interpreted the model’s decision criteria to evaluate its validity, thereby developing a model that provided the decision-interpretability required for clinical application.
- 17 April 2023
- Published by Oxford University Press (OUP) in European Heart Journal - Digital Health
- Vol. 4 (3) , 254-264
Open AccessAn explainable artificial intelligence-enabled electrocardiogram analysis model for the classification of reduced left ventricular function
Aims: The black box nature of artificial intelligence (AI) hinders the development of interpretable AI models that are applicable in clinical practice. We aimed to develop an AI model for classifying patients of reduced left ventricular ejection fraction (LVEF) from 12-lead electrocardiograms (ECG) with the decision-interpretability. Methods and results: We acquired paired ECG and echocardiography datasets from the central and co-operative institutions. For the central institution dataset, a random forest model was trained to identify patients with reduced LVEF among 29 907 ECGs. Shapley additive explanations were applied to 7196 ECGs. To extract the model’s decision criteria, the calculated Shapley additive explanations values were clustered for 192 non-paced rhythm patients in which reduced LVEF was predicted. Although the extracted criteria were different for each cluster, these criteria generally comprised a combination of six ECG findings: negative T-wave inversion in I/V5–6 leads, low voltage in I/II/V4–6 leads, Q wave in V3–6 leads, ventricular activation time prolongation in I/V5–6 leads, S-wave prolongation in V2–3 leads, and corrected QT interval prolongation. Similarly, for the co-operative institution dataset, the extracted criteria comprised a combination of the same six ECG findings. Furthermore, the accuracy of seven cardiologists’ ECG readings improved significantly after watching a video explaining the interpretation of these criteria (before, 62.9% ± 3.9% vs. after, 73.9% ± 2.4%; P = 0.02). Conclusion: We visually interpreted the model’s decision criteria to evaluate its validity, thereby developing a model that provided the decision-interpretability required for clinical application.
- Open Access
- 1 March 2022
- Published by Elsevier in Journal of Cardiology
- Vol. 79 (3) , 334-341
Deep learning model to detect significant aortic regurgitation using electrocardiography
- 1 March 2022
- Published by Elsevier in Journal of Cardiology
- Vol. 79 (3) , 334-341
Open AccessDeep learning model to detect significant aortic regurgitation using electrocardiography
- Open Access
- 5 August 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (8) , e0255577
Automatic detection of vessel structure by deep learning using intravascular ultrasound images of the coronary arteries
Intravascular ultrasound (IVUS) is a diagnostic modality used during percutaneous coronary intervention. However, specialist skills are required to interpret IVUS images. To address this issue, we developed a new artificial intelligence (AI) program that categorizes vessel components, including calcification and stents, seen in IVUS images of complex lesions. When developing our AI using U-Net, IVUS images were taken from patients with angina pectoris and were manually segmented into the following categories: lumen area, medial plus plaque area, calcification, and stent. To evaluate our AI’s performance, we calculated the classification accuracy of vessel components in IVUS images of vessels with clinically significantly narrowed lumina (< 4 mm2) and those with severe calcification. Additionally, we assessed the correlation between lumen areas in manually-labeled ground truth images and those in AI-predicted images, the mean intersection over union (IoU) of a test set, and the recall score for detecting stent struts in each IVUS image in which a stent was present in the test set. Among 3738 labeled images, 323 were randomly selected for use as a test set. The remaining 3415 images were used for training. The classification accuracies for vessels with significantly narrowed lumina and those with severe calcification were 0.97 and 0.98, respectively. Additionally, there was a significant correlation in the lumen area between the ground truth images and the predicted images (ρ = 0.97, R2 = 0.97, p < 0.001). However, the mean IoU of the test set was 0.66 and the recall score for detecting stent struts was 0.64. Our AI program accurately classified vessels requiring treatment and vessel components, except for stents in IVUS images of complex lesions. AI may be a powerful tool for assisting in the interpretation of IVUS imaging and could promote the popularization of IVUS-guided percutaneous coronary intervention in a clinical setting.
- 5 August 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (8) , e0255577
Open AccessAutomatic detection of vessel structure by deep learning using intravascular ultrasound images of the coronary arteries
Intravascular ultrasound (IVUS) is a diagnostic modality used during percutaneous coronary intervention. However, specialist skills are required to interpret IVUS images. To address this issue, we developed a new artificial intelligence (AI) program that categorizes vessel components, including calcification and stents, seen in IVUS images of complex lesions. When developing our AI using U-Net, IVUS images were taken from patients with angina pectoris and were manually segmented into the following categories: lumen area, medial plus plaque area, calcification, and stent. To evaluate our AI’s performance, we calculated the classification accuracy of vessel components in IVUS images of vessels with clinically significantly narrowed lumina (< 4 mm2) and those with severe calcification. Additionally, we assessed the correlation between lumen areas in manually-labeled ground truth images and those in AI-predicted images, the mean intersection over union (IoU) of a test set, and the recall score for detecting stent struts in each IVUS image in which a stent was present in the test set. Among 3738 labeled images, 323 were randomly selected for use as a test set. The remaining 3415 images were used for training. The classification accuracies for vessels with significantly narrowed lumina and those with severe calcification were 0.97 and 0.98, respectively. Additionally, there was a significant correlation in the lumen area between the ground truth images and the predicted images (ρ = 0.97, R2 = 0.97, p < 0.001). However, the mean IoU of the test set was 0.66 and the recall score for detecting stent struts was 0.64. Our AI program accurately classified vessels requiring treatment and vessel components, except for stents in IVUS images of complex lesions. AI may be a powerful tool for assisting in the interpretation of IVUS imaging and could promote the popularization of IVUS-guided percutaneous coronary intervention in a clinical setting.