WNWeifen Niu

Weifen Niu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Weifen Niu has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Yishuo Tong

    School of Forensic Medicine, Shanxi Key Laboratory of Forensic Medicine, Shanxi Medical University, Jinzhong 030600, Shanxi, People's Republic of China

    4 shared publications
  • Yandan Wang

    School of Forensic Medicine, Key Laboratory of Forensic Toxicology of Ministry of Public Security, Shanxi Medical University, Jinzhong, People’s Republic of China

    3 shared publications
  • Zheyu Wang

    School of Forensic Medicine, Shanxi Key Laboratory of Forensic Medicine, Shanxi Medical University, Jinzhong 030600 Shanxi, People's Republic of China

    3 shared publications
  • Baihui Liu

    School of Forensic Medicine, Shanxi Key Laboratory of Forensic Medicine, Shanxi Medical University, Jinzhong 030600, Shanxi, People's Republic of China

    2 shared publications
  • Chao Zhang

    School of Forensic Medicine Shanxi Medical University Jinzhong China

    2 shared publications
  • Juan Jia

    School of Forensic Medicine Shanxi Medical University Jinzhong China

    2 shared publications

Latest Publications

  • Enzyme-aided amplification strategy for sensitive detection of methamphetamine based on fluorescence aptamer sensor

    by Zheyu Wang, Yandan Wang, Yishuo Tong, Weifen Niu

    Methamphetamine (METH) abuse poses a serious risk to human health and social stability. It is critical to develop sensitive and selective methods for detecting METH. Here, we develop a fluorescence aptamer sensor to detect METH based on DNA exonuclease III (Exo III), graphene oxide (GO), and FAM-labeled aptamer. First, the sensor used GO’s strong binding capacity to adsorb and quench the fluorescence of the aptamer attached to GO surface. When METH was added to the system, the formation of stable complex for aptamer and METH dissociated from the surface of GO, leading to a fluorescence restoration. Then, the fluorescence signal was further amplified by using Exo III to liberate target METH for cyclic hybridization. And the gel electrophoresis experiment further verified the reliability of this strategy. This aptamer sensor exhibited a low detection limit (0.52 nM) and excellent selectivity under optimal conditions. Notably, this sensor has been successfully validated in the detection of METH in urine and saliva samples, exhibited commendable recovery (94.00–104.65%). Its benefits include facile, sensitive, and rapid. Expected to be used in practical METH detection. Graphical abstract


  • Aptamer‐based fluorescent sensor for highly sensitive detection of methamphetamine

    by Yandan Wang, Zheyu Wang, Yishuo Tong, Dan Zhang, Keming Yun, Jiangwei Yan, Weifen Niu

    The construction of a fluorescence aptamer sensor was achieved by employing the fundamental principle of fluorescence resonance energy transfer. By employing molecular modeling technologies to identify the binding site, the high‐affinity aptamer APT‐40nt was derived from the whole sequence and utilized on the graphene oxide (GO) fluorescent platform for the purpose of achieving a highly sensitive detection of methamphetamine (METH). The aptamer tagged with fluorescein (FAM) dye undergoes quenching in the presence of GO due to π‐stacking interaction. With the addition of the target, the aptamer that has been tagged was detached from the GO surface, forming a stable complex with METH. This process resulted in fluorescence restoration of the system, and the degree of fluorescence restoration was proportional to METH concentration in the linear range of 1–50 and 50–200 nM. Notably, under optimized conditions, the detection limit of this aptasensor was as low as 0.78 nM, which meets the detection limit requirements of METH detection in saliva and urine in some countries and regions. Moreover, other common illicit drugs and metabolites had minimizing interference with the determination. The established aptasensor, therefore, has been successfully applied to detect METH in saliva and urine samples and exhibited satisfactory recoveries (87%–111%). This aptasensor has the advantages of low detection limit, excellent selectivity, ease of operation, and low cost, providing a promising strategy for on‐site detection of METH in saliva and urine.


  • Ratiometric fluorimetric and colorimetric probe for sensing and imaging pH changes in living cells

    by Zhiwen Wei, Juan Jia, Yige Gong, Yandan Wang, Weifen Niu

    Cell, enzyme, and tissue activity in living organisms are closely related to intracellular pH. Detecting the changes of intracellular pH is important to understanding the physiological and pathological changes in the process of crucial cell metabolism. A pH probe (HTBI) based on hemicyanine was synthesized. The probe solution displayed a marked colour change from yellow to amaranth with the pH increase from neutral to basic; simultaneously, the emission spectra showed a significant red shift. The probe exhibited a ratiometric fluorescence emission (F586nm/F542nm) characteristic of pKa 8.82. As expected, HTBI exhibited high sensitivity and selectivity for pH, fine photostability, reversibility, and low cytotoxicity. Therefore, it would be a very useful tool for measuring the intracellular pH changes.


  • A chemiluminescence sensor array for discrimination of seven toxicants

    by Ziqi Zhou, Yige Gong, Chao Zhang, Weifen Niu

    A chemiluminescence (CL) sensor array was developed based on 11 CL systems cross‐combined by three luminescence reagents and four oxidants. Using the CL sensor array, we measured seven toxicants, including morphine, ketamine, diazepam, chlorpromazine, strychnine, paraquat, and fenpropathrin, which represent psychotropic drugs, sedatives and hypnotics, rodenticides, herbicides, and insecticides, respectively. The CL response pattern or ‘fingerprints’ were obtained for a given compound on the sensor array and then discriminated through principal component analysis. The established sensor array has been applied to real‐life samples and the results showed that it possesses excellent discrimination.


  • Ratiometric emission NIR-fluorescent probe for the detection of lysosomal pH in living cells and in vivo

    by Weifen Niu, Juan Jia, Junkai Li, Chao Zhang, Keming Yun

    The lysosome is known to be an acidic organelle that is ubiquitous in cells. Acidic pH is a characteristic feature of lysosomes, and aberrant lysosomal pH values have been manifested to be associated with diverse diseases. In order to monitor the lysosomal pH changes, we developed a ratiometric emission NIR-fluorescent probe (CzQl) for the quantitative analysis of the lysosomal pH in living cells and in vivo. CzQl was constructed via the ethylene bridging of carbazole derivatives and quinoline. The protonation of the probe resulted in a marked green-to-red emission color change. The probe exhibited an ideal pKa value of 4.60 with a linear relationship in the pH range of 3.9–5.3, which covered most of the pH ranges of lysosomes, and was useful for the quantitative detection and imaging of lysosomal pH changes. Moreover, CzQl exhibited easy loading capability, high selectivity, a large Stokes shift, specific lysosome-targeting ability and low cytotoxicity; thereby, it was successfully used for monitoring the lysosomal pH changes at a cellular level as well as the LPS-mediated inflammation in vivo.


  • A chemiluminescence sensor array based on nanomaterials for discrimination of teas

    by Weifen Niu

    In recent years, electronic tongue and nose devices have been developed that consist of an array of cross‐responsive sensors. In this study, we report a chemiluminescence (CL) sensor array based on oxidation at twelve different catalytic nanomaterial locations for the discrimination of eight teas. CL response patterns or “fingerprints” were obtained for a given compound on the sensor array and then discriminated through linear discriminant analysis. The experiments demonstrate that the sensor array had excellent differentiability and reversibility. Copyright © 2012 John Wiley & Sons, Ltd.