Lars Körner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lars Körner has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Richard Leach
University of Nottingham
3 shared publications A. Dieterich
Zoologisches Institut, Abteilung Evolutionsbiologie der Invertebraten, Universität Tübingen , Germany
1 shared publication- Alexander Rack
ESRF – The European Synchrotron, Grenoble, France
1 shared publication - Alexey Ershov
Institute for Photon Science and Synchrotron Radiation (IPS), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
1 shared publication - Christian Schmitt
152Institut für Physik, Universität Mainz, Mainz, Germany
1 shared publication - Daniel Haas
“Interconfessionality in the Early Modern Period” Research Training Group, University of Hamburg, Germany.
1 shared publication
Latest Publications
- 1 September 2021
- Published by Elsevier in Precision Engineering
- Vol. 71, 324-325
Corrigendum to “Amplitude-wavelength maps for X-ray computed tomography systems” [Precis Eng 64 (2020) 228–242]
- 1 September 2021
- Published by Elsevier in Precision Engineering
- Vol. 71, 324-325
Corrigendum to “Amplitude-wavelength maps for X-ray computed tomography systems” [Precis Eng 64 (2020) 228–242]
- Open Access
- 16 September 2019
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 30 (12) , 125002
Increasing throughput in x-ray computed tomography measurement of surface topography using sinogram interpolation
X-ray computed tomography (XCT) is a non-destructive imaging technique that has recently gained interest as a tool to measure surface topography. Large acquisition times are a major shortcoming of XCT. One contributing factor to the acquisition time is that a measurement can require the acquisition of thousands of radiographic projections. This paper explores the combined effects of undersampling, i.e. taking fewer radiographic projections and sinogram interpolation, i.e. estimating the missing radiographic projections by interpolation. Different degrees of sinogram interpolation are investigated through the measurement of the surfaces of a metal, additively manufactured part. The quality of the measurement result is assessed via the analysis of the reconstructed volumes, through the computation of quantitative indicators of spatial resolution and noise, and via the analysis of surface topographies extracted from the reconstructed volumes. The quality of the surfaces is assessed through the use of statistical models designed to estimate repeatability errors in the reconstruction, and through the computation of surface texture parameters. Results obtained with no undersampling and no sinogram interpolation are taken as reference. It is shown that noise in the volumetric reconstruction increases with respect to the reference with larger degrees of undersampling, but the increment can be partly compensated by sinogram interpolation with the effects on spatial resolution more difficult to interpret. The computation of surface texture parameters results in similar values for all but one case, the largest undersampling. The topography of the reconstructions indicate that the repeatability error remains similar in all experimental conditions, excluding the case of largest undersampling. Overall, the results indicate that a reduction of the acquisition time of XCT topography measurement is feasible. However, the obtained surface topographies suffer, and large undersampling creates unrecoverable negative effects on the spatial resolution, the noise characteristics and the obtained topographies, even when sinogram interpolation is used.
- 16 September 2019
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 30 (12) , 125002
Open AccessIncreasing throughput in x-ray computed tomography measurement of surface topography using sinogram interpolation
X-ray computed tomography (XCT) is a non-destructive imaging technique that has recently gained interest as a tool to measure surface topography. Large acquisition times are a major shortcoming of XCT. One contributing factor to the acquisition time is that a measurement can require the acquisition of thousands of radiographic projections. This paper explores the combined effects of undersampling, i.e. taking fewer radiographic projections and sinogram interpolation, i.e. estimating the missing radiographic projections by interpolation. Different degrees of sinogram interpolation are investigated through the measurement of the surfaces of a metal, additively manufactured part. The quality of the measurement result is assessed via the analysis of the reconstructed volumes, through the computation of quantitative indicators of spatial resolution and noise, and via the analysis of surface topographies extracted from the reconstructed volumes. The quality of the surfaces is assessed through the use of statistical models designed to estimate repeatability errors in the reconstruction, and through the computation of surface texture parameters. Results obtained with no undersampling and no sinogram interpolation are taken as reference. It is shown that noise in the volumetric reconstruction increases with respect to the reference with larger degrees of undersampling, but the increment can be partly compensated by sinogram interpolation with the effects on spatial resolution more difficult to interpret. The computation of surface texture parameters results in similar values for all but one case, the largest undersampling. The topography of the reconstructions indicate that the repeatability error remains similar in all experimental conditions, excluding the case of largest undersampling. Overall, the results indicate that a reduction of the acquisition time of XCT topography measurement is feasible. However, the obtained surface topographies suffer, and large undersampling creates unrecoverable negative effects on the spatial resolution, the noise characteristics and the obtained topographies, even when sinogram interpolation is used.
- Open Access
- 1 March 2019
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 24 (3)
Sinogram interpolation to decrease acquisition time in X-ray computed tomography measurement of surface topography
The Largest Portal of Nondestructive Testing (NDT) Open Access Archive, Conference Proceedings, Journal Articles, News, Products, Services. Professional Networking, Exhibition, Forums, Jobs
- 1 March 2019
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 24 (3)
Open AccessSinogram interpolation to decrease acquisition time in X-ray computed tomography measurement of surface topography
The Largest Portal of Nondestructive Testing (NDT) Open Access Archive, Conference Proceedings, Journal Articles, News, Products, Services. Professional Networking, Exhibition, Forums, Jobs
- 28 September 2017
- Published by ASME International in Journal of Micro and Nano-Manufacturing
- Vol. 5 (4)
Two-Side Laser Processing Method for Producing High Aspect Ratio Microholes
Laser microprocessing is a very attractive option for a growing number of industrial applications due to its intrinsic characteristics, such as high flexibility and process control and also capabilities for noncontact processing of a wide range of materials. However, there are some constrains that limit the applications of this technology, i.e., taper angles on sidewalls, edge quality, geometrical accuracy, and achievable aspect ratios of produced structures. To address these process limitations, a new method for two-side laser processing is proposed in this research. The method is described with a special focus on key enabling technologies for achieving high accuracy and repeatability in two-side laser drilling. The pilot implementation of the proposed processing configuration and technologies is discussed together with an in situ, on-machine inspection procedure to verify the achievable positional and geometrical accuracy. It is demonstrated that alignment accuracy better than 10 μm is achievable using this pilot two-side laser processing platform. In addition, the morphology of holes with circular and square cross sections produced with one-side laser drilling and the proposed method was compared in regard to achievable aspect ratios and holes' dimensional and geometrical accuracy and thus to make conclusions about its capabilities.
- 28 September 2017
- Published by ASME International in Journal of Micro and Nano-Manufacturing
- Vol. 5 (4)
Two-Side Laser Processing Method for Producing High Aspect Ratio Microholes
Laser microprocessing is a very attractive option for a growing number of industrial applications due to its intrinsic characteristics, such as high flexibility and process control and also capabilities for noncontact processing of a wide range of materials. However, there are some constrains that limit the applications of this technology, i.e., taper angles on sidewalls, edge quality, geometrical accuracy, and achievable aspect ratios of produced structures. To address these process limitations, a new method for two-side laser processing is proposed in this research. The method is described with a special focus on key enabling technologies for achieving high accuracy and repeatability in two-side laser drilling. The pilot implementation of the proposed processing configuration and technologies is discussed together with an in situ, on-machine inspection procedure to verify the achievable positional and geometrical accuracy. It is demonstrated that alignment accuracy better than 10 μm is achievable using this pilot two-side laser processing platform. In addition, the morphology of holes with circular and square cross sections produced with one-side laser drilling and the proposed method was compared in regard to achievable aspect ratios and holes' dimensional and geometrical accuracy and thus to make conclusions about its capabilities.
- 26 September 2008
- Published by Taylor & Francis in Synchrotron Radiation News
- Vol. 21 (5) , 34-38
High-Speed X-ray Cineradiography for Analyzing Complex Kinematics in Living Insects
- 26 September 2008
- Published by Taylor & Francis in Synchrotron Radiation News
- Vol. 21 (5) , 34-38
High-Speed X-ray Cineradiography for Analyzing Complex Kinematics in Living Insects