STSoichiro Tsujino

Soichiro Tsujino

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Soichiro Tsujino has a total of 228 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Transverse structure of field-emission electron wave packets from nanometer-scale hemispheroidal cathodes and two-dimensional film edge emitters

    by Soichiro Tsujino, Soheil Hajibaba

    The transverse structure of field-emission electron wave packets is governed by the cathode material and geometry through the near-apex electrostatic potential, which induces electrostatic defocusing and spatial transmission filtering. To study these effects, we develop a framework for field-emission wave-packet propagation that combines finite-element electrostatic potentials with paraxial Schrödinger propagation under an effective parabolic transverse-potential approximation, together with barrier-side spatial filtering. Applied to nanometer-scale prolate hemispheroidal emitters, the method enables efficient wave-packet calculations that reproduce the expected electron-optical defocusing and show how tunneling-induced narrowing can amplify subsequent transverse expansion. We further apply the framework to a two-dimensional film-edge model of a graphene edge emitter, where the Å-scale initial width leads to stronger transverse expansion. The resulting wave packets are then used to study coherent multi-site superposition, predicting either overall beam narrowing or fragmentation into multiple beamlets, which may contribute to the striated field-emission-microscopy patterns reported for graphene edges.

  • Surface-Acoustic-Wave-Driven Acoustic Tweezing in a Silicon Microfluidic Chip

    by Shichao Jia, Hanmu Guo, Roderick Y. H. Lim, Soichiro Tsujino

    Surface acoustic wave (SAW)-driven acoustic tweezers have been widely explored for high-resolution ultrasonic sample manipulation. Among these, hybrid acoustic tweezers comprising a reusable SAW chip and a disposable glass or silicon microfluidic chip as a superstrate offer advantages such as reduced experimental costs and minimized cross-contamination between experiments. However, maximizing the acoustic pressure within the microfluidic channel requires efficient acoustic coupling between the SAW and the microfluidic structure. In this work, we investigate the frequency-dependent characteristics of acoustophoresis of 50 MHz hybrid acoustic tweezers composed of a SAW chip and a silicon microfluidic chip. We elucidate the role of the bulk acoustic wave resonances in the silicon substrate in facilitating the formation of acoustic standing waves within the microfluidic channel. Experimental results demonstrate the generation of acoustic pressures up to 2.1 ± 0.5 MPa inside the channel. The fabricated device was successfully used to probe the transient viscoelastic deformation of HEK293T cells and to trap motile cells Tetrahymena. These findings highlight the potential of the propose hybrid acoustic tweezers as a platform for acoutsto-mechanical testing of soft matter and biological samples.

  • Open Access

    Surface-acoustic-wave driven silicon microfluidic chips for acoustic tweezing of motile cells and viscoelastic microbeads

    by Shichao Jia, Soichiro Tsujino

    Acoustic tweezers comprising a surface acoustic wave chip and a disposable silicon microfluidic chip are potentially advantageous to stable and cost-ffective acoustofluidic experiments while avoiding the cross-contamination by reusing the surface acoustic wave chip and disposing of the microfluidic chip. For such a device, it is important to optimize the chip-to-chip bonding and the size and shape of the microfluidic chip to enhance the available acoustic pressure. In this work, aiming at studying samples with the size of a few tens of microns, we explore the device structure and assembly method of acoustic tweezers. By using a polymer bonding layer and shaping the silicon microfluidic chip via deep reactive ion etching, we were able to attain the acoustic pressure up to 2 MPa with a corresponding acoustic radiation pressure of 0.2 kPa for 50 MHz ultrasound, comparable to reported values at lower ultrasound frequencies. We utilized the fabricated acoustic tweezers for non-contact viscoelastic deformation experiments of soft matter and trapping of highly motile cells. These results suggests that the feasibility of the hybrid chip approach to attaining the high acoustic force required to conduct acoustomechanical testing of small soft matters and cells.

  • Open Access

    Electrostatic interference control of a high-energy coherent electron beam using three-element Boersch phase shifters

    by Pooja Thakkar, Vitaliy A. Guzenko, Peng-Han Lu, Rafal E. Dunin-Borkowski, Jan Pieter Abrahams, Soichiro Tsujino

    Static phase shifters have been intensely studied for generating two- and three-dimensional electron beam patterns. However, those are restricted to specific electron beam energies and microscope settings. Aiming at overcoming such limitations, the development of programmable phase shifters based on e.g. a Boersch phase is an active field of research. We recently demonstrated a three-element Boersch phase shifter device [Thakkar et al., J. Appl. Phys. 128, 134502 (2020)], which was fabricated by electron beam lithography and is compatible with up-scaling. However, it suffers from parasitic beam deflection and cross-talk. Here, we report a five-layer phase shifter device, which is based on a metal–insulator–metal–insulator–metal structure as originally envisioned by Boersch that reduces cross-talk. We demonstrate a three-element Boersch phase shifter that shows minimal beam deflection of voltage-controlled three-electron-beam interference patterns in a transmission electron microscope operated at 200 keV. The feasibility of using such multi-element phase shifter arrays is discussed in this article.


  • Open Access

    Electrostatic interference control of a high-energy coherent electron beam using a three-element Boersch phase shifter

    by Pooja Thakkar, Vitaliy A. Guzenko, Peng-Han Lu, Rafal E. Dunin-Borkowski, Jan Pieter Abrahams, Soichiro Tsujino

    In contrast to static holographic phase shifters, which are restricted to specific electron beam energies and microscope settings, Boersch phase shifters are promising for creating programmable arrays for generating two- and three-dimensional electron beam patterns. We recently demonstrated a three-element Boersch phase shifter device [Thakkar et al., J. Appl. Phys. 128 (2020), 134502], which was fabricated by electron beam lithography and is compatible with up-scaling. However, it suffers from parasitic beam deflection and resulting cross-talk. Here, we report a five-layer phase shifter device, which is based on a metal-insulator-metal-insulator-metal structure (as originally envisioned by Boersch) that reduces cross-talk. We demonstrate a three-element Boersch phase shifter that shows minimal beam deflection of voltage-controlled three-electron-beam interference patterns in a transmission electron microscope operated at 200 keV. The feasibility of using such multi-element phase shifter arrays is discussed.

  • Open Access

    Inertial mixing of acoustically levitated droplets for time‐lapse protein crystallography

    by Soichiro Tsujino, Yohei Sato, Shichao Jia, Michal W. Kepa, Sofia Trampari, Takashi Tomizaki

    Varying the chemical consistency of acoustically levitated droplets opens up an in situ study of chemical and biochemical reactions in small volumes. However, the optimization of the mixing time and the minimization of the positional instability induced by solution dispensing are necessary for practical applications such as the study of the transient state of macromolecules crystallography during the ligand binding processes. For this purpose, we study the inertial mixing in a configuration compatible with the room‐temperature crystallography using the acoustic levitation diffractometer, therein solution drops ejected at high velocity collide and coalesce with droplets dispensed on acoustically levitated and rotating polymer thin‐film sample holders. With the proposed method, we are able to achieve the mixing time of ∼0.1 s for sub‐micro and a few microliter droplets. The observed short mixing time is ascribed to the rapid penetration of the solution into the droplets and confirmed by a computational fluid dynamic simulation. The demonstrated accelerated solution mixing is tested in a pilot time‐lapse protein crystallography experiment using the acoustic levitation diffractometer. The results indicate the detection of transient ligand binding state within 2 s after the solution dispensing, suggesting the feasibility of the proposed method for studying slow biochemical processes.


  • Open Access

    Size and shape dependent rotation characteristics of thin film ultrasonic rotors

    by Shichao Jia, Yohei Sato, Soichiro Tsujino

    The controlled rotation of acoustically levitated samples is beneficial for analyzing sample properties, e.g., in a recently reported room temperature x-ray diffraction experiment, wherein thin film sample holders comprising thin film disks with short blades attached around their circumference were utilized. However, the mechanism of producing the torque and the determinant factor of the rotation direction for these planar ultrasonic rotors have been elusive. We, therefore, study the impact of the size and shape on the rotation characteristics of these ultrasonic rotors in air and further study the influence of the viscosity of fluid. Theory and experiment demonstrate the essential role of the short blades in producing the acoustic torque both in air and water. In the airborne case, the shape and arrangement of the blades are found to determine the rotation direction. In water, with a dynamic viscosity 55 times higher than that of air, we demonstrate that ultrasonic rotors down to 25-μm-disk-diameter function in an optimized experimental geometry with approximately the same actuation efficiency as in air. Our results will be beneficial to further improve the applicability of the ultrasonic rotors as sample holders for airborne experiments and to explore the micrometer-scale ultrasonic rotors in liquid.


  • Open Access

    Publisher Correction: Acoustic levitation and rotation of thin films and their application for room temperature protein crystallography

    by Michal. W. Kepa, Takashi Tomizaki, Yohei Sato, Dmitry Ozerov, Hiroshi Sekiguchi, Nobuhiro Yasuda, Koki Aoyama, Petr Skopintsev, Jörg Standfuss, Robert Cheng, et al.

  • Open Access

    On the brightness, transverse emittance, and transverse coherence of field emission beam

    by Soichiro Tsujino

    The highly brilliant electron beam produced by field emitters is one of the enabling factors of the high resolution electron microscope with atomic resolution. In addition to high beam brightness, field emitters are also high current, high current density, and highly coherent cathodes. These characteristics motivated the use of field emitters for high-frequency vacuum electric tubes and accelerator applications and in experiments including electron diffraction, holography, coherent diffraction imaging, to name a few. Here, we present an overview of the key characteristics of field emitters for beam applications: beam brightness, transverse emittance, and transverse coherence. We further discuss their implications on the coherent propagation of the field emission beam.


  • Open Access

    Acoustic levitation and rotation of thin films and their application for room temperature protein crystallography

    by Michal. W. Kepa, Takashi Tomizaki, Yohei Sato, Dmitry Ozerov, Hiroshi Sekiguchi, Nobuhiro Yasuda, Koki Aoyama, Petr Skopintsev, Jörg Standfuss, Robert Cheng, et al.

    Acoustic levitation has attracted attention in terms of chemical and biochemical analysis in combination with various analytical methods because of its unique container-less environment for samples that is not reliant on specific material characteristics. However, loading samples with very high viscosity is difficult. To expand the scope, we propose the use of polymer thin films as sample holders, whereby the sample is dispensed on a film that is subsequently loaded onto an acoustic levitator. When applied for protein crystallography experiments, rotation controllability and positional stability are important prerequisites. We therefore study the acoustic levitation and rotation of thin films with an aspect ratio (the diameter-to-thickness ratio) of 80–240, which is an order of magnitude larger than those reported previously. For films with empirically optimized shapes, we find that it is possible to control the rotation speed in the range of 1–4 rotations per second while maintaining a positional stability of 12 ± 5 µm. The acoustic radiation force acting on the films is found to be a factor of 26–30 higher than that for same-volume water droplets. We propose use cases of the developed films for protein crystallography experiments and demonstrate data collections for large single crystal samples at room temperature.