DADaniela Astudillo-Rubio

Daniela Astudillo-Rubio

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Daniela Astudillo-Rubio has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Diagnostic accuracy of artificial intelligence models for detecting interproximal caries on bitewing radiographs using ICCMS as reference standard: a systematic review.

    by Kevin Augusto Ochoa Suarez, Daniela Chamba-León, Wilson Daniel Bravo Torres, Daniela Astudillo-Rubio

    INPLASY202630001 Diagnostic accuracy of artificial intelligence models for detecting interproximal caries on bitewing radiographs using ICCMS as reference standard: a systematic review Keywords: Bi…

  • Open Access

    Primary stability with osseodensification drilling of dental implants in the posterior maxilla region in humans: A systematic review

    by Alejandro Fereño-Cáceres, Rómulo Vélez-Astudillo, Wilson Bravo-Torres, Daniela Astudillo-Rubio, Jacinto Alvarado-Cordero

    Currently, a new non-subtractive drilling technique, called osseodensification (OD), has been developed. It involves using specially designed drills with large negative cutting angles that rotate counterclockwise, causing expansion through plastic bone deformation, thus compacting the autologous bone to the osteotomy walls, which improves the primary stability of the implant.The present systematic review aimed to determine whether the OD technique can increase the primary stability of dental implants in the posterior maxilla region as compared to the conventional drilling (CD) technique.Five databases were searched up to June 30, 2022. The inclusion criteria embraced observational clinical studies, randomized and non-randomized controlled trials, human studies in vivo, comparing OD and CD, with the measurement of the primary stability of implants in the posterior maxilla region by means of the implant stability quotient (ISQ). The tools used to assess the risk of bias were RoB 2 and the NewcastleOttawa Scale (NOS).Seven articles met the inclusion criteria, with 4 classified as having a low risk of bias and 3 with a moderate risk of bias. The OD technique consistently demonstrated an average ISQ value of 73 KHz across all studies, whereas CD yielded an average value of 58.49 kHz (p < 0.001 for 5 articles).It can be concluded that in comparison with CD, OD improves primary stability at baseline in low-density bone, such as the maxilla.


  • Open Access

    Resistance of CAD/CAM composite resin and ceramic occlusal veneers to fatigue and fracture in worn posterior teeth: A systematic review

    by Karelys Del Cisne Maldonado, Juan Andres Espinoza, Daniela Andrea Astudillo, Bolivar Andres Delgado, Wilson Daniel Bravo

    Severe tooth wear is related to substantial loss of tooth structure, with dentin exposure and significant loss (≥1/3) of the clinical crown. The objective of this systematic review was to summarize and analyze the scientific evidence regarding the mechanical performance of computer-aided design/computer-aided manufacturing (CAD/CAM) composite resin and CAD/CAM lithium disilicate ceramic occlusal veneers, in terms of fatigue and fracture resistance, on severely worn posterior teeth. Currently, occlusal veneers are an alternative for treating worn posterior teeth. Although scientific evidence demonstrates the good performance of lithium disilicate occlusal veneers, there are less brittle materials with a modulus of elasticity more similar to dentin than ceramics, such as resin CAD/CAM blocks. Therefore, it is important to identify which type of material is best for restoring teeth with occlusal wear defects and which material can provide better clinical performance. This review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. A comprehensive search of the PubMed, Embase, Web of Science, Scopus, Cochrane, OpenGrey, Redalyc, DSpace, and Grey Literature Report databases was conducted and supplemented by a manual search, with no time or language limitations, until January 2022. We aimed to identify studies evaluating the fatigue and fracture resistance of CAD/CAM composite resin and ceramic occlusal veneers. The quality of the full-text articles was evaluated according to the modified Consolidated Standards of Reporting Trials (CONSORT) criteria for in vitro studies, and 400 articles were initially identified. After removing duplicates and applying the selection criteria, 6 studies were included in the review. The results demonstrated that the mechanical performance of CAD/CAM composite resin occlusal veneers is comparable to that of CAD/CAM lithium disilicate occlusal veneers in terms of fatigue and fracture resistance.


  • Open Access

    Effect of gastric acids on the mechanical properties of conventional and CAD/CAM resin composites - An in-vitro study

    by Alexandra Gil-Pozo, Daniela Astudillo-Rubio, Álvaro Ferrando Cascales, Francesco Inchingolo, Ronaldo Hirata, Salvatore Sauro, Andrés Delgado-Gaete


  • Open Access

    Total Rehabilitation Using Adhesive Dental Restorations in Patients with Severe Tooth Wear: A 5-Year Retrospective Case Series Study

    by Álvaro Ferrando Cascales, Salvatore Sauro, Ronaldo Hirata, Daniela Astudillo-Rubio, Raúl Ferrando Cascales, Rubén Agustín-Panadero, Andrés Delgado-Gaete

    Introduction: Currently, there is little clinical evidence to support the medium- and long-term survival and clinical performance of ultraconservative approaches using adhesive restorations in full-mouth restorations. The aim of this case series study was to evaluate the medium-term clinical performance of anterior and posterior adhesive restorations applied with direct and indirect techniques using resin composites and glass-ceramic-based materials. Materials and Methods: The inclusion criteria were an esthetic problem as the main reason for consultation and severe generalized wear of grade 2 to 4 according to the Tooth Wear Evaluation System (TWES 2.0). In addition, at each follow-up appointment, patients were required to submit a clinical-parameter-monitoring record according to the modified United States Public Health Service (USPHS) criteria. Results: Eight patients with severe tooth wear were treated through full rehabilitation in a private dental clinic in Spain by a single operator (AFC). A total of 212 restorations were performed, which were distributed as follows: 66 occlusal veneers, 26 palatal veneers and 120 vestibular veneers. No signs of marginal microleakage or postoperative sensitivity were observed in any occlusal, vestibular and/or palatal restoration after the follow-up period. The estimated survival rate of the 212 restorations was 90.1% over 60 months of observation, with a survival time of 57.6 months. Only 21 restorations had complications, which were mostly resolved with a direct composite resin. The dichotomous variables of the restoration type (posterior veneer, anterior veneer) and the type of restored tooth (anterior, posterior) were the risk predictors with statistically significant influences (p < 0.005) on the survival of the restorations. Conclusion: According to the results of this study, there is a significantly higher risk of restorative complications in posterior teeth compared to anterior teeth. Also, it can be concluded that the indication of adhesive anterior and posterior restorations is justified in the total oral rehabilitation of patients with severe multifactorial tooth wear, as they are associated with a low risk of failure.


  • Open Access

    Therapies for sleep bruxism in dentistry: A critical evaluation of systematic reviews

    by Lissette Cerón, Mishelle Pacheco, Bolivar Delgado, Wilson Bravo, Daniela Astudillo

    The aim of the study was to evaluate the methodological quality and the risk of bias of systematic reviews with regard to the literature on therapies for sleep bruxism (SB) in dentistry, applying the AMSTAR 2 (A MeaSurement Tool to Assess systematic Reviews) qualitative guide, as well as the effectiveness of various kinds of treatment of SB. Initially, a total of 1,499 articles were obtained from 4 databases and 2 websites. Relevant articles were obtained from the PubMed, Scopus, Cochrane, and Embase databases as well as from Google Scholar and OpenGrey. Six systematic reviews that met the eligibility criteria were included. The methodological quality of all systematic reviews, assessed with the AMSTAR 2 tool, was critically low. Regarding treatment effectiveness, 5 systematic reviews reported on pharmacological management (botulinum toxin type A (BTX-A), clonazepam and clonidine), 2 reported on oral appliances (OAs) (stabilizing splints and mandibular advancement devices (MADs)) and 1 study addressed the effects of biofeedback (BF). The results of the therapies were diverse and confusing. The available research is not conclusive, and does not show clear evidence or a consensus on the part of researchers on the most effective treatment for the management of SB. More research of better methodological quality is needed in this area.


  • Primary stability with the osseodensification drilling technique for dental implants in low density bone in humans: a systematic review

    by Rómulo Andrés Vélez, Cuenca University, Alejandro Fereño Caceres, Wilson Daniel Bravo Torres, Daniela Astudillo Rubio, Jacinto José Alvarado Cordero

    Review question / Objective: - Does the osseodensification drilling technique increase primary stability in low-density bone? - The aim of the present investigation was to evaluate primary stability in dental implants in people with low density bone using the osseodensification technique. Condition being studied: The replacement of missing teeth through dental implants is currently the most practiced in dental clinics. The main criterion for determining the success of an implant is osseointegration, which is a direct structural and functional connection between vital bone and the prosthetic load-bearing surface of an implant. In the same way, primary stability must be obtained for a good lasting clinical result of the implant and to achieve this purpose, the bone density must be evaluated where the dental implant is to be placed. Salah Huwais in 2013 introduced a new osteotomy procedure (Oseodensification) for site preparation without removal and bone preservation. The Osseodensification process produces an autograft layer around the implant with the osteotomy surface, the autologous bone comes into contact through an endosteal device that accelerates osseointegration due to the nucleation of osteoblasts in the instrumented bone adjacent to the implant and has a greater primary stability due to contact between the device and the bone.

  • Fatigue and fracture resistance and survival of occlusal veneers of composite resin and ceramics blocks in posterior teeth with occlusal wear: A protocol for a systematic review

    by Karelys Maldonado, Universidad de Cuenca- Facultad de Odontología, Juan Espinoza, Daniela Astudillo, Wilson Bravo

    Review question / Objective: The aim of this systematic review is to synthesize the scientific evidence that evaluates fatigue and fracture resistance, survival, and stress distribution, of composite resin CAD/CAM and ceramic CAD/CAM occlusal veneers in posterior teeth with severe occlusal wear. Condition being studied: Currently there is an increase in cases of dental wear, due to several factors such as: excessive consumption of carbonated drinks, a diet high in acids, gastric diseases, anorexia, bulimia, dental grinding, use of highly abrasive toothpastes, or a combination of these(9) (10) (11) (12); which affect the patient in several aspects: loss of vertical dimension, sensitivity due to the exposure of dentin, esthetics, affectation of the neuromuscular system(11) (13) (14). With the advent of minimally invasive dentistry, occlusal veneers have been found to be a valid option to rehabilitate this type of cases and thus avoid greater wear of the dental structure with full coverage restorations. Sometimes when performing a tabletop it is not necessary to perform any preparation, thus preserving the maximum amount of dental tissue(3) (6) (15). Due to the masticatory load either in patients without parafunction where the maximum masticatory force is approximately 424 N for women and 630 N for men or in those who present parafunction where the maximum bite force can vary from 780 to 1120N(7), it is necessary that the occlusal veneers support that load which makes indispensable a compilation of studies investigating both fatigue and fracture resistance and the survival rate of occlusal veneers in different materials and thicknesses.

  • Accuracy in marginal and/or internal adaptation of full-coverage fixed prostheses made with digital versus conventional impressions: an overview of systematic reviews and meta-analysis

    by University of Cuenca- Faculty of Dentistry, María Augusta Cajas, Marcela Cabrera, Jaime Astudillo, Yulissa Abad, Daniela Astudillo

    Review question / Objective: Is the accuracy (marginal adaptation and / or internal adaptation) of fixed full coverage prostheses made with digital impressions better than conventional impressions? Eligibility criteria: Inclusion criteria• Systematic reviews and / or meta-analyzes that evaluated the precision (marginal adaptation and / or internal adaptation) of full coverage fixed prostheses on natural teeth in clinical studies and on tooth replicas in in vitro studies.• Systematic reviews and / or meta-analyzes comparing digital impressions with an intraoral scanner versus conventional impressions taken with any impression material.• Systematic reviews and / or meta-analyzes of randomized clinical trials (RCTs), prospective comparative and in vitro and non-randomized clinical trials.Exclusion criteria:• Systematic literature reviews, case reports, pilot studies• Studies evaluating the seating of crowns on implants and partial restorations• Studies with no response from the author to the requested information query.