JPJonathan. G. Pressman

Jonathan. G. Pressman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jonathan. G. Pressman has a total of 99 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Properties of Anion Exchange Resins Processed by Three Grinding Methods

    by Eva K. Stebel, David G. Wahman, Jonathan G. Pressman, Margaret Kupferle, Gulizhaer Abulikemu, Samantha J. Smith, Brooke N. Gray, Cameron X. Gastaldo, Esther W. Hughes, Sophia G. Pedigo, et al.

    Rapid small-scale column tests (RSSCTs) are used to simulate full-scale treatment processes with granular activated carbon (GAC). This technique has recently been applied to ion exchange (I... Practical ApplicationsMany water treatment systems are currently considering deploying ion exchange systems to remove certain per- and polyfluoroalkyl substances from water. Due to the time and exp... The graphical abstract consists of four panels in sequence, connected by arrows. The first panel is labeled “Bulk Resin.” It contains a photograph of ion exchange resin beads and a micrograph of a ...

  • Implications for modeling anion exchange treatment of perfluoroalkyl substances in drinking water and related natural organic impacts: a pilot study

    by Samantha J. Smith, David G. Wahman, Eric J. Kleiner, Brooke N. Gray, Toby T. Sanan, Eva K. Stebel, Cameron X. Gastaldo, Esther W. Hughes, Sophia G. Pedigo, Boris Datsov, et al.


  • Estimating Ion Exchange Resin Intraparticle Diffusion Coefficients: Method Development and Nitrate Application

    by Samantha J. Smith, Brooke N. Gray, Esther W. Hughes, Levi M. Haupert, Isabella L. Bass, Eric J. Kleiner, Ben J. Burkhart, Sophia G. Pedigo, Jackson D. Quinn, Gulizhaer Abulikemu, et al.

    Gel‐type anion exchange (AEX) resin performance is impacted by internal mass transfer, which is represented by the solid‐phase intraparticle diffusion coefficient ( D s ). Importantly, D s values are required inputs to ion exchange treatment process models but are rarely reported. Previous experiments using gel‐type AEX resins exhibited external mass transfer control, preventing D s estimation for several anions, including perfluoroalkyl substances. To reduce external mass transfer resistance and allow D s estimation, a stainless‐steel centrifugal stirrer device was standardized and validated with nitrate (model anion). Initially, experiments were conducted across mixing speeds (750–1750 rpm) to balance (1) maximizing external mass transfer and (2) preventing flow disturbances. Subsequently, experiments used an optimized speed to estimate nitrate D s at multiple initial concentrations on three gel‐type AEX resins. The developed methodology was useful for determining nitrate D s and should enable improved D s estimates for other contaminants, including perfluoroalkyl substances, needed for ion exchange treatment process models.

  • Perfluoroalkyl Chemical Adsorption by Granular Activated Carbon: Impacts of Source Water Characteristics

    by Gulizhaer Abulikemu, Jonathan G. Pressman, David G. Wahman, George A. Sorial, Toby T. Sanan, Eva K. Stebel, Brooke N. Gray, Esther W. Hughes, Eric J. Kleiner, Sophia G. Pedigo, et al.

    Water characteristic impacts on granular activated carbon (Filtrasorb 400) adsorption of nine per‐ and polyfluoroalkyl substances (PFAS) were studied. Multispecies competitive isotherms had lower effective solid phase capacities () than single species isotherms. pH 9 q e s were somewhat reduced (max 19%) compared to pH 7.7–8.1. Decreasing ionic strength (10 to 2 mM) substantially (79%–146%) increased PFAS q e s. Divalent ion (calcium and sulfate) presence without changing ionic strength increased q e s (43%–140%). Natural organic matter (NOM) presence reduced PFAS q e s with the reduction somewhat offset by calcium and sulfate presence. This reduced capacity suggested both direct competition with NOM and pore‐blockage hindered PFAS adsorption. Ideal adsorbed solution theory poorly predicted the competition, likely due to nonideal behaviors of adsorbed species and GAC surface heterogeneity. Findings provide insights into the complex interactions between different water constituents and the adsorptive surface to help optimize PFAS treatment efficacy and minimize operational costs.


  • Perfluoroalkyl chemical adsorption by granular activated carbon: Assessment of particle size impact on equilibrium parameters and associated rapid small-scale column test scaling assumptions

    by Gulizhaer Abulikemu, Jonathan G. Pressman, George A. Sorial, Toby T. Sanan, Levi M. Haupert, Jonathan B. Burkhardt, Samantha J. Smith, Eric J. Kleiner, Eva K. Stebel, Brooke N. Gray, et al.


  • Evaluation of distribution system water quality during a free chlorine conversion

    by Matthew T. Alexander, Peyton Woodruff, Jatin H. Mistry, Helen Y. Buse, Christy Muhlen, Darren A. Lytle, Jonathan G. Pressman, David G. Wahman

    Chloraminated drinking water systems commonly use free chlorine conversions (FCCs) to prevent or control nitrification, but unintended water quality changes may occur, including increased disinfection by‐product and metal concentrations. This study evaluated water quality in a chloraminated drinking water system and residential locations before, during, and after their annual, planned FCC. Water quality alternated between relatively consistent and variable periods when switching disinfectants. During the FCC, regulated four trihalomethane and five haloacetic acid concentrations increased by four and seven times, respectively, and exceeded corresponding maximum contaminant levels. Implications of disinfection by‐product sampling during an FCC were assessed, and an approach to account for increased FCC disinfection by‐product concentrations was proposed. For metals, the FCC had minor impacts on distribution system concentrations and did not appear to impact residential concentrations. Overall, observed variable water quality appeared primarily associated with switching disinfectants and depended on distribution system hydraulics.


  • Microelectrode investigation of iron and copper surfaces aged in presence of monochloramine

    by Beatriz C. Gonzalez, Jennifer E. Liggett, Darren A. Lytle, Woo Hyoung Lee, Stephen M. Harmon, Jonathan G. Pressman, David G. Wahman

    Ductile iron and copper coupons were aged 137–189 days and 2 days, respectively, with 2 mg Cl2 L−1 monochloramine under four water chemistries (pH 7 or 9 and 0 or 3 mg L−1 orthophosphate). Subsequently, microelectrode profiles of monochloramine concentration, oxygen concentration, and pH were measured from the bulk water to near the coupon reactive surface, allowing estimation of flux and apparent surface reaction rate constants for monochloramine and oxygen. Both metals showed similar trends with orthophosphate where orthophosphate decreased metal reactivity with monochloramine (pH 9) and oxygen (pH 7). Comparing iron and copper coupons, apparent surface reaction rate constants for monochloramine and oxygen were one and two orders of magnitude greater, respectively, for iron coupons under all conditions. Overall, this research provides the first insights into monochloramine concentration, oxygen concentration, and pH by direct measurement near ductile iron and copper reactive surfaces aged in the presence of monochloramine.

  • Applying microelectrodes to investigate aged ductile iron and copper coupon reactivity during free chlorine application

    by Jennifer E. Liggett, Beatriz C. Gonzalez, Darren A. Lytle, Jonathan G. Pressman, Dionysios D. Dionysiou, Woo Hyoung Lee, Stephen M. Harmon, David G. Wahman


  • Strong Base Anion Exchange Selectivity of Nine Perfluoroalkyl Chemicals Relevant to Drinking Water

    by David G. Wahman, Samantha J. Smith, Eric J. Kleiner, Gulizhaer Abulikemu, Eva K. Stebel, Brooke N. Gray, Brian C. Crone, Rose D. Taylor, Erika A. Womack, Cameron X. Gastaldo, et al.

    Selectivity with respect to chloride (KPFAS∕C) was determined for nine drinking water relevant perfluoroalkyl and polyfluoroalkyl substances (PFAS): perfluoro-2-propoxypropanoic acid (GenX), five perfluoroalkyl carboxylic acids (PFCAs), and three perfluoroalkyl sulfonic acids (PFSAs). Three single-use strong base anion exchange gel resins were investigated, targeting drinking water relevant equilibrium PFAS liquid concentrations (≤500 ng/L). Except for the longest carbon chain PFCA (perfluorodecanoic acid) and PFSA (perfluorooctanesulfonic acid) studied, PFAS followed traditional ion exchange theory (law of mass action), including increasing equilibrium PFAS liquid concentrations with increasing equilibrium chloride liquid concentrations. Overall, KPFAS∕C values were (i) similar among resins for a given PFAS, (ii) 1-5 orders of magnitude greater than the selectivity of inorganic anions (e.g., nitrate) previously studied, (iii) 2 orders of magnitude greater for the same carbon chain length PFSA versus PFCA, (iv) found to proportionally increase with carbon chain length for both PFSAs and PFCAs, and (v) similar for GenX and perfluorohexanoic acid (six-carbon PFCA). A multisolute competition experiment demonstrated binary isotherm-determined KPFAS∕C values could be applied to simulate a multisolute system, extending work previously done with only inorganic anions to PFAS. Ultimately, estimated KPFAS∕C values allow future extension and validation of an open-source anion exchange column model to PFAS.


  • Microelectrode evaluation of in situ oxidant reactivity and pH variability at new ductile iron and copper coupon surfaces

    by Woo Hyoung Lee, David G. Wahman, Darren A. Lytle, Jonathan G. Pressman, Jongik Chung