Jonathan. G. Pressman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jonathan. G. Pressman has a total of 99 co-authors. Here are the top co-authors by number of shared publications:
- David G. Wahman
US Environmental Protection Agency
24 shared publications - Gulizhaer Abulikemu
Department of Chemical and Environmental Engineering, University of Cincinnati, Cincinnati, OH, 45221, USA; Pegasus Technical Services, Inc., Cincinnati, OH, 45268, USA
8 shared publications - Levi M. Haupert
US Environmental Protection Agency
8 shared publications - Samantha J. Smith
US Environmental Protection Agency
8 shared publications Gulizhaer Abulikemu
Pegasus Technical Services, Inc., Cincinnati, Ohio 45268, United States
7 shared publicationsCameron X. Gastaldo
Oak Ridge Institute for Science and Education
6 shared publications
Latest Publications
- 1 August 2026
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 152 (8) , 04026044
Properties of Anion Exchange Resins Processed by Three Grinding Methods
Rapid small-scale column tests (RSSCTs) are used to simulate full-scale treatment processes with granular activated carbon (GAC). This technique has recently been applied to ion exchange (I... Practical ApplicationsMany water treatment systems are currently considering deploying ion exchange systems to remove certain per- and polyfluoroalkyl substances from water. Due to the time and exp... The graphical abstract consists of four panels in sequence, connected by arrows. The first panel is labeled “Bulk Resin.” It contains a photograph of ion exchange resin beads and a micrograph of a ...
- 1 August 2026
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 152 (8) , 04026044
Properties of Anion Exchange Resins Processed by Three Grinding Methods
Rapid small-scale column tests (RSSCTs) are used to simulate full-scale treatment processes with granular activated carbon (GAC). This technique has recently been applied to ion exchange (I... Practical ApplicationsMany water treatment systems are currently considering deploying ion exchange systems to remove certain per- and polyfluoroalkyl substances from water. Due to the time and exp... The graphical abstract consists of four panels in sequence, connected by arrows. The first panel is labeled “Bulk Resin.” It contains a photograph of ion exchange resin beads and a micrograph of a ...
- 26 September 2025
- Published by Elsevier in Water Research
- Vol. 288 (Pt B) , 124685
Implications for modeling anion exchange treatment of perfluoroalkyl substances in drinking water and related natural organic impacts: a pilot study
- 26 September 2025
- Published by Elsevier in Water Research
- Vol. 288 (Pt B) , 124685
Implications for modeling anion exchange treatment of perfluoroalkyl substances in drinking water and related natural organic impacts: a pilot study
- 1 September 2025
- Published by Wiley in AWWA Water Science
- Vol. 7 (5)
Estimating Ion Exchange Resin Intraparticle Diffusion Coefficients: Method Development and Nitrate Application
Gel‐type anion exchange (AEX) resin performance is impacted by internal mass transfer, which is represented by the solid‐phase intraparticle diffusion coefficient ( D s ). Importantly, D s values are required inputs to ion exchange treatment process models but are rarely reported. Previous experiments using gel‐type AEX resins exhibited external mass transfer control, preventing D s estimation for several anions, including perfluoroalkyl substances. To reduce external mass transfer resistance and allow D s estimation, a stainless‐steel centrifugal stirrer device was standardized and validated with nitrate (model anion). Initially, experiments were conducted across mixing speeds (750–1750 rpm) to balance (1) maximizing external mass transfer and (2) preventing flow disturbances. Subsequently, experiments used an optimized speed to estimate nitrate D s at multiple initial concentrations on three gel‐type AEX resins. The developed methodology was useful for determining nitrate D s and should enable improved D s estimates for other contaminants, including perfluoroalkyl substances, needed for ion exchange treatment process models.
- 1 September 2025
- Published by Wiley in AWWA Water Science
- Vol. 7 (5)
Estimating Ion Exchange Resin Intraparticle Diffusion Coefficients: Method Development and Nitrate Application
Gel‐type anion exchange (AEX) resin performance is impacted by internal mass transfer, which is represented by the solid‐phase intraparticle diffusion coefficient ( D s ). Importantly, D s values are required inputs to ion exchange treatment process models but are rarely reported. Previous experiments using gel‐type AEX resins exhibited external mass transfer control, preventing D s estimation for several anions, including perfluoroalkyl substances. To reduce external mass transfer resistance and allow D s estimation, a stainless‐steel centrifugal stirrer device was standardized and validated with nitrate (model anion). Initially, experiments were conducted across mixing speeds (750–1750 rpm) to balance (1) maximizing external mass transfer and (2) preventing flow disturbances. Subsequently, experiments used an optimized speed to estimate nitrate D s at multiple initial concentrations on three gel‐type AEX resins. The developed methodology was useful for determining nitrate D s and should enable improved D s estimates for other contaminants, including perfluoroalkyl substances, needed for ion exchange treatment process models.
- 22 July 2025
- Published by Wiley in AWWA Water Science
- Vol. 7 (4)
Perfluoroalkyl Chemical Adsorption by Granular Activated Carbon: Impacts of Source Water Characteristics
Water characteristic impacts on granular activated carbon (Filtrasorb 400) adsorption of nine per‐ and polyfluoroalkyl substances (PFAS) were studied. Multispecies competitive isotherms had lower effective solid phase capacities () than single species isotherms. pH 9 q e s were somewhat reduced (max 19%) compared to pH 7.7–8.1. Decreasing ionic strength (10 to 2 mM) substantially (79%–146%) increased PFAS q e s. Divalent ion (calcium and sulfate) presence without changing ionic strength increased q e s (43%–140%). Natural organic matter (NOM) presence reduced PFAS q e s with the reduction somewhat offset by calcium and sulfate presence. This reduced capacity suggested both direct competition with NOM and pore‐blockage hindered PFAS adsorption. Ideal adsorbed solution theory poorly predicted the competition, likely due to nonideal behaviors of adsorbed species and GAC surface heterogeneity. Findings provide insights into the complex interactions between different water constituents and the adsorptive surface to help optimize PFAS treatment efficacy and minimize operational costs.
- 22 July 2025
- Published by Wiley in AWWA Water Science
- Vol. 7 (4)
Perfluoroalkyl Chemical Adsorption by Granular Activated Carbon: Impacts of Source Water Characteristics
Water characteristic impacts on granular activated carbon (Filtrasorb 400) adsorption of nine per‐ and polyfluoroalkyl substances (PFAS) were studied. Multispecies competitive isotherms had lower effective solid phase capacities () than single species isotherms. pH 9 q e s were somewhat reduced (max 19%) compared to pH 7.7–8.1. Decreasing ionic strength (10 to 2 mM) substantially (79%–146%) increased PFAS q e s. Divalent ion (calcium and sulfate) presence without changing ionic strength increased q e s (43%–140%). Natural organic matter (NOM) presence reduced PFAS q e s with the reduction somewhat offset by calcium and sulfate presence. This reduced capacity suggested both direct competition with NOM and pore‐blockage hindered PFAS adsorption. Ideal adsorbed solution theory poorly predicted the competition, likely due to nonideal behaviors of adsorbed species and GAC surface heterogeneity. Findings provide insights into the complex interactions between different water constituents and the adsorptive surface to help optimize PFAS treatment efficacy and minimize operational costs.
- 1 May 2024
- Published by Wiley in AWWA Water Science
- Vol. 6 (3)
Evaluation of distribution system water quality during a free chlorine conversion
Chloraminated drinking water systems commonly use free chlorine conversions (FCCs) to prevent or control nitrification, but unintended water quality changes may occur, including increased disinfection by‐product and metal concentrations. This study evaluated water quality in a chloraminated drinking water system and residential locations before, during, and after their annual, planned FCC. Water quality alternated between relatively consistent and variable periods when switching disinfectants. During the FCC, regulated four trihalomethane and five haloacetic acid concentrations increased by four and seven times, respectively, and exceeded corresponding maximum contaminant levels. Implications of disinfection by‐product sampling during an FCC were assessed, and an approach to account for increased FCC disinfection by‐product concentrations was proposed. For metals, the FCC had minor impacts on distribution system concentrations and did not appear to impact residential concentrations. Overall, observed variable water quality appeared primarily associated with switching disinfectants and depended on distribution system hydraulics.
- 1 May 2024
- Published by Wiley in AWWA Water Science
- Vol. 6 (3)
Evaluation of distribution system water quality during a free chlorine conversion
Chloraminated drinking water systems commonly use free chlorine conversions (FCCs) to prevent or control nitrification, but unintended water quality changes may occur, including increased disinfection by‐product and metal concentrations. This study evaluated water quality in a chloraminated drinking water system and residential locations before, during, and after their annual, planned FCC. Water quality alternated between relatively consistent and variable periods when switching disinfectants. During the FCC, regulated four trihalomethane and five haloacetic acid concentrations increased by four and seven times, respectively, and exceeded corresponding maximum contaminant levels. Implications of disinfection by‐product sampling during an FCC were assessed, and an approach to account for increased FCC disinfection by‐product concentrations was proposed. For metals, the FCC had minor impacts on distribution system concentrations and did not appear to impact residential concentrations. Overall, observed variable water quality appeared primarily associated with switching disinfectants and depended on distribution system hydraulics.
- 1 May 2024
- Published by Wiley in AWWA Water Science
- Vol. 6 (3)
Microelectrode investigation of iron and copper surfaces aged in presence of monochloramine
Ductile iron and copper coupons were aged 137–189 days and 2 days, respectively, with 2 mg Cl2 L−1 monochloramine under four water chemistries (pH 7 or 9 and 0 or 3 mg L−1 orthophosphate). Subsequently, microelectrode profiles of monochloramine concentration, oxygen concentration, and pH were measured from the bulk water to near the coupon reactive surface, allowing estimation of flux and apparent surface reaction rate constants for monochloramine and oxygen. Both metals showed similar trends with orthophosphate where orthophosphate decreased metal reactivity with monochloramine (pH 9) and oxygen (pH 7). Comparing iron and copper coupons, apparent surface reaction rate constants for monochloramine and oxygen were one and two orders of magnitude greater, respectively, for iron coupons under all conditions. Overall, this research provides the first insights into monochloramine concentration, oxygen concentration, and pH by direct measurement near ductile iron and copper reactive surfaces aged in the presence of monochloramine.
- 1 May 2024
- Published by Wiley in AWWA Water Science
- Vol. 6 (3)
Microelectrode investigation of iron and copper surfaces aged in presence of monochloramine
Ductile iron and copper coupons were aged 137–189 days and 2 days, respectively, with 2 mg Cl2 L−1 monochloramine under four water chemistries (pH 7 or 9 and 0 or 3 mg L−1 orthophosphate). Subsequently, microelectrode profiles of monochloramine concentration, oxygen concentration, and pH were measured from the bulk water to near the coupon reactive surface, allowing estimation of flux and apparent surface reaction rate constants for monochloramine and oxygen. Both metals showed similar trends with orthophosphate where orthophosphate decreased metal reactivity with monochloramine (pH 9) and oxygen (pH 7). Comparing iron and copper coupons, apparent surface reaction rate constants for monochloramine and oxygen were one and two orders of magnitude greater, respectively, for iron coupons under all conditions. Overall, this research provides the first insights into monochloramine concentration, oxygen concentration, and pH by direct measurement near ductile iron and copper reactive surfaces aged in the presence of monochloramine.
- 15 February 2024
- Published by Elsevier in Water Research
- Vol. 253, 121324
Applying microelectrodes to investigate aged ductile iron and copper coupon reactivity during free chlorine application
- 15 February 2024
- Published by Elsevier in Water Research
- Vol. 253, 121324
Applying microelectrodes to investigate aged ductile iron and copper coupon reactivity during free chlorine application
- 16 November 2023
- Published by American Chemical Society (ACS) in ACS ES&T Water
- Vol. 3 (12) , 3967-3979
Strong Base Anion Exchange Selectivity of Nine Perfluoroalkyl Chemicals Relevant to Drinking Water
Selectivity with respect to chloride () was determined for nine drinking water relevant perfluoroalkyl and polyfluoroalkyl substances (PFAS): perfluoro-2-propoxypropanoic acid (GenX), five perfluoroalkyl carboxylic acids (PFCAs), and three perfluoroalkyl sulfonic acids (PFSAs). Three single-use strong base anion exchange gel resins were investigated, targeting drinking water relevant equilibrium PFAS liquid concentrations (≤500 ng/L). Except for the longest carbon chain PFCA (perfluorodecanoic acid) and PFSA (perfluorooctanesulfonic acid) studied, PFAS followed traditional ion exchange theory (law of mass action), including increasing equilibrium PFAS liquid concentrations with increasing equilibrium chloride liquid concentrations. Overall, values were (i) similar among resins for a given PFAS, (ii) 1-5 orders of magnitude greater than the selectivity of inorganic anions (e.g., nitrate) previously studied, (iii) 2 orders of magnitude greater for the same carbon chain length PFSA versus PFCA, (iv) found to proportionally increase with carbon chain length for both PFSAs and PFCAs, and (v) similar for GenX and perfluorohexanoic acid (six-carbon PFCA). A multisolute competition experiment demonstrated binary isotherm-determined values could be applied to simulate a multisolute system, extending work previously done with only inorganic anions to PFAS. Ultimately, estimated values allow future extension and validation of an open-source anion exchange column model to PFAS.- 16 November 2023
- Published by American Chemical Society (ACS) in ACS ES&T Water
- Vol. 3 (12) , 3967-3979
Strong Base Anion Exchange Selectivity of Nine Perfluoroalkyl Chemicals Relevant to Drinking Water
Selectivity with respect to chloride () was determined for nine drinking water relevant perfluoroalkyl and polyfluoroalkyl substances (PFAS): perfluoro-2-propoxypropanoic acid (GenX), five perfluoroalkyl carboxylic acids (PFCAs), and three perfluoroalkyl sulfonic acids (PFSAs). Three single-use strong base anion exchange gel resins were investigated, targeting drinking water relevant equilibrium PFAS liquid concentrations (≤500 ng/L). Except for the longest carbon chain PFCA (perfluorodecanoic acid) and PFSA (perfluorooctanesulfonic acid) studied, PFAS followed traditional ion exchange theory (law of mass action), including increasing equilibrium PFAS liquid concentrations with increasing equilibrium chloride liquid concentrations. Overall, values were (i) similar among resins for a given PFAS, (ii) 1-5 orders of magnitude greater than the selectivity of inorganic anions (e.g., nitrate) previously studied, (iii) 2 orders of magnitude greater for the same carbon chain length PFSA versus PFCA, (iv) found to proportionally increase with carbon chain length for both PFSAs and PFCAs, and (v) similar for GenX and perfluorohexanoic acid (six-carbon PFCA). A multisolute competition experiment demonstrated binary isotherm-determined values could be applied to simulate a multisolute system, extending work previously done with only inorganic anions to PFAS. Ultimately, estimated values allow future extension and validation of an open-source anion exchange column model to PFAS.- 13 July 2023
- Published by Elsevier in Water Research
- Vol. 243, 120352
Microelectrode evaluation of in situ oxidant reactivity and pH variability at new ductile iron and copper coupon surfaces
- 13 July 2023
- Published by Elsevier in Water Research
- Vol. 243, 120352
Microelectrode evaluation of in situ oxidant reactivity and pH variability at new ductile iron and copper coupon surfaces