SCSiddharth Chamarthy

Siddharth Chamarthy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Siddharth Chamarthy has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Gait Adaptation Using a Cable-Driven Active Leg Exoskeleton (C-ALEX) With Post-Stroke Participants

    by Rand Hidayah, Lauri Bishop, Xin Jin, Siddharth Chamarthy, Joel Stein, Sunil K. Agrawal

    Individuals with chronic hemiparesis post-stroke exhibit gait impairments that require functional rehabilitation through training. Exoskeletal robotic assistive devices can provide a user with continuous assistance but impose movement restrictions. There are currently devices that allow unrestricted movement but provide assistance only intermittently at specific points of the gait cycle. Our design, a cable-driven active leg exoskeleton (C-ALEX), allows the user both unrestricted movement and continuous force assistance throughout the gait cycle to assist the user in new walking patterns. In this study, we assessed the ability of C-ALEX to induce a change in the walking patterns of ten post-stroke participants using a singlesession training protocol. The ability of C-ALEX to accurately provide forces and torques in the desired directions was also evaluated to compare its design performance to traditional rigidlink designs. Participants were able to reach 91% ± 12% of their target step length and 89% ± 13 % of their target step height. The achieved step parameters differed significantly from participant baselines (p < 0.05). To quantify the performance, the forces in each cable’s out of the plane movements were evaluated relative to the in-plane desired cable tension magnitudes. This corresponded to an error of under 2Nm in the desired controlled joint torques. This error magnitude is low compared to the system command torques and typical adult biological torques during walking (2-4%) [1]. These results point to the utility of using non-restrictive cable-driven architectures in gait retraining, in which future focus can be on rehabilitating gait pathologies seen in stroke survivors.


  • Walking With Augmented Reality: A Preliminary Assessment of Visual Feedback With a Cable-Driven Active Leg Exoskeleton (C-ALEX)

    by Rand Hidayah, Siddharth Chamarthy, Avni Shah, Matthew Fitzgerald-Maguire, Sunil K. Agrawal

    Visual and force feedback are common elements in rehabilitation robotics, but visual feedback is difficult to provide in over-ground mobile exoskeleton systems. This letter aims to provide a method to integrate visual feedback using an augmented reality HoloLens headset with our mobile C-ALEX system. A preliminary study was carried out to assess the effects of providing force-only (Haptic), force and visual (HoloHapt) or visual (Visual) feedback to three independent groups, each containing eight participants. The groups showed an increase in normalized step height, nSH (HoloHapt: 1.10 $\pm$ 0.13, Haptic: 1.03 $\pm$ 0.23 Visual: 1.61 $\pm$ 0.52) and decreased normalized trajectory tracking error, TE (HoloHapt: 42.8% $\pm$ 23.4%, Haptic: 47.6% $\pm$ 18.4%, Visual: 114 .2 % $\pm$ 60.0 % ). Visual nSH differed significantly from HoloHapt and Haptic nSH ( $p< 0.005$ ). Lap-wise normalized tracking error differed significantly ( $p < 0.005$ ) within participants. The results show the feasibility of and differences between each form of feedback for overground gait training. This information is useful for future studies targeted at patients with gait impairments.