CBCharles Bienvenue

Charles Bienvenue

*This is an algorithmically generated author record based on publicly available information.

Charles Bienvenue has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Impacts of Nuclear-Reactor-Physics Models for Secondary Photons on Coupled Photon-Electron-Positron Transport Problems

    by Ahmed Naceur, Gabriel Famulari, Charles Bienvenue, Jean-François Carrier, Alain Hébert

    Fully coupled photon-electron-positron computational schemes are needed in a broad range of domains, from radiotherapy and radiosurgery treatment planning to nuclear-reactor safety analysis. Industrial deployment of such schemes remains problematic because of the prohibitively time-consuming charged-particle-transport aspects of both Monte Carlo algorithms and Boltzmann-Fokker-Planck solvers. In this paper, a partially coupled scheme based on reactor-physics models for secondary photons (RPSPs) is presented. RPSPs include thick-target-bremsstrahlung, annihilation, and full atomic cascade models, recovering long-range effects of both electrons and positrons. The RPSP-based scheme is compared with state-of-the-art fully coupled and uncoupled schemes in medical, nuclear, and multidisciplinary contexts. Within tissues, the average discrepancies from the fully coupled scheme are about 0.5%, with a maximum error below 1.3% at high energy. The CPU time of the coupled schemes is reduced by 58 and 78 times for 3- and 6-MeV beams, respectively. The discrepancies are also within the accuracy of the cross sections for 4Be, 6C, 13Al, 26Fe, 29Cu, 32Ge, 47Ag, 79Au, 82Pb, and 92U slabs. The same discrepancies are about 0.1%, 0.4% and 0.8%, respectively, in the reactor's shielding, vessel and fuel slabs. A power peaking factor reduction of 4.35 times from the state-of-the-art uncoupled scheme is demonstrated for uranium oxide and mixed plutonium-uranium oxide slabs.


  • Open Access

    Submicrometric absolute positioning of flat reflective surfaces using Michelson interferometry

    by C. Bienvenue, S. Vallières, S. Payeur, P. Antici

    We present a Target Positioning Interferometer (TPI), a system that uses variations of the wavefront curvature to position solid reflective surfaces with submicrometric precision. The TPI is a Michelson interferometer into which a lens is inserted in the target arm and the mirror of the reference arm is slightly tilted. The TPI configuration presented in this work allows us to position the surface of a reflective target on a beam focus within an uncertainty of 350 nm (2σ) in a subsecond timeframe, using a lens with a numerical aperture of NA = 0.20. We support our experimental findings with numerical simulations of the interference pattern using the ABCD matrices’ method, allowing us to define scaling laws for using the TPI with different optics and environments, as well as suggestions to improve the TPI accuracy and adapt the system to different applications. This system is very well suited for accurate and repeatable target positioning used in laser-driven ion acceleration, where a precise alignment is key to optimize the proton acceleration mechanism.


  • Low-energy proton calibration and energy-dependence linearization of EBT-XD radiochromic films

    by S. Vallières, C. Bienvenue, P. Puyuelo-Valdes, M. Salvadori, E. D’hUmières, F. Schiettekatte, P. Antici

    In this work, we calibrate the newly developed EBT-XD radiochromic films (RCFs) manufactured by Gafchromictm using protons in the energy range of 4–10 MeV. Irradiation was performed on the 2 × 6 MV tandem linear accelerator located at the Université de Montréal. The RCFs were digitized using an Epson Perfection V700 flatbed scanner using both the red-green-blue and grayscale channels. The proton fluences were measured with Faraday cups calibrated in absolute terms. The linear energy transfer function within the active layer of the films was calculated using the mass stopping power tables coming from the PSTAR database from the National Institute of Standards and Technology (NIST) to allow retrieval of the deposited dose. We find that the calibration curves for 7 and 10 MeV protons are nearly equivalent. The 4 MeV calibration curves exhibit a quenching effect due to the Bragg peak that falls close to the active layer. A linearization of this energy dependence was developed using a semiempirical parametric model to allow the generation of calibration curves for any incident proton energy within the present range. Excellent correspondence (<5% dose difference for the same netOD) of the 10 MeV calibration curves was noted when compared to existing high-energy proton (148.2 MeV) calibration curves reported in the literature. Our calibration extends the range of operation of EBT-XD films to low-energy proton beam dosimetry.