    Screening for hypertension in the inpatient environment (SHINE): a prospective diagnostic accuracy study among adult hospital patients

    by Laura Catherine Armitage, Cristian Roman, Beth K Lawson, Adam Mahdi, Christopher Biggs, Louise Young, Holly Edmundson, Thomas Fanshawe, Lionel Tarassenko, Andrew Farmer, et al.

    Background: Hypertension is the leading risk factor for death globally. Undiagnosed hypertension is common, but the incidence in hospitalised patients is unclear. There are calls for universal facility-based screening for hypertension among all attending patients. The hospital inpatient setting, where blood pressure (BP) is measured routinely and repeatedly, presents an ideal opportunity. However, international hypertension guidelines do not include inpatient BP thresholds for diagnostic or treatment purposes. We investigated the performance of current UK community BP thresholds for diagnosing hypertension in the hospital setting. Objectives: Investigate the diagnostic performance of the current UK ambulatory BP diagnostic thresholds for systolic and diastolic hypertension in the hospital setting against the reference test of community-based ambulatory BP monitoring (ABPM). Design: A prospective diagnostic accuracy study. Setting: Hospital inpatients admitted to three UK centres were approached. Follow-up ABPM was delivered in the community. Participants: Eligible patients were aged between 18 and 80 years, with no prior diagnosis of, or prescription for hypertension, and whose mean cumulative daytime BP was 120 mm Hg to 179 mm Hg systolic and ≤109 mm Hg diastolic from the 24th hour of their hospital admission. Interventions: Participants received 24-hour ABPM 4–26 weeks post-discharge, as the reference test for hypertension, with UK diagnostic thresholds of an average daytime BP of ≥135 mm Hg systolic and ≥85 mm Hg diastolic applied. Participants found to be severely hypertensive at the ABPM fitting appointment were also considered reference-test positive but did not proceed with ABPM. Primary and secondary outcome measures: The diagnostic performance of a mean daytime in-hospital BP of ≥135 mm Hg systolic or ≥85 mm Hg diastolic (index test) for the prediction of hypertension diagnosed on ABPM (reference test) was assessed using sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) as primary outcome measures. Additionally, we explored the accuracy of a range of alternative in-hospital systolic and diastolic BP thresholds against the same reference test. Results: 351 participants were enrolled and 206 completed the study protocol. The average age of the 206 participants was 53 years, 55% were male, and 91 (44%) had daytime community hypertension on ABPM reference testing. Of 107 participants with raised in-hospital daytime BP, 59 (55%) had daytime community hypertension. When assessing the performance of the index test for detecting daytime community hypertension, sensitivity was 65% (59/91, 54% to 75%) and specificity was 58% (67/115, 49% to 67%). The PPV was 55% (59/107, 45% to 65%) and NPV was 68% (67/99, 58% to 77%), respectively. A further 45/206 participants (23%) had night-time community hypertension when assessed using European diagnostic thresholds for nocturnal hypertension (120 mm Hg systolic or 70 mm Hg diastolic), while 25/107 of those with raised in-hospital daytime BP (23%) had night-time community hypertension. When assessing the performance of the index test for detecting either day or night-time community hypertension, sensitivity was 62% (84/135, 53% to 70%) and specificity was 68% (48/71, 55% to 78%). The PPV was 79% (84/107, 70% to 86%) and NPV was 48% (48/99, 38% to 59%). Conclusions: Undiagnosed hypertension is common in hospitalised patients, particularly those with raised in-hospital BP. While in-hospital BP alone is an imperfect predictor and should not be used as a stand-alone diagnostic test, this could serve as a trigger for further assessment of BP in the community after discharge. Trial registration number: The study protocol was registered with the ISCTRN Registry ( ISRCTN80586284 ).


  • Co-production and implementation of an evidence collation strategy for a novel point-of-care information resource: gpevidence.org

    by Julian Treadwell, Laura C Armitage, Kiana K Collins, Laura Heath, Olu Onyimadu, Mandy Payne, Azizia Wahedi, Kamal R Mahtani


  • Open Access

    Diagnosing hypertension in primary care: a retrospective cohort study to investigate the importance of night-time blood pressure assessment

    by Laura C Armitage, Shaun Davidson, Adam Mahdi, Mirae Harford, Richard McManus, Andrew Farmer, Peter Watkinson, Lionel Tarassenko

    Background: Ambulatory blood-pressure monitoring (ABPM) has become less frequent in primary care since the COVID-19 pandemic, with home blood-pressure monitoring (HBPM) often the preferred alternative; however, HBPM cannot measure night-time blood pressure (BP), and patients whose night-time BP does not dip, or rises (reverse dipping), have poorer cardiovascular outcomes.Aim: To investigate the importance of measuring night-time BP when assessing individuals for hypertension.Design and setting: Retrospective cohort study of two patient populations — namely, hospital patients admitted to four UK acute hospitals located in Oxfordshire, and participants of the BP in different ethnic groups (BP-Eth) study, who were recruited from 28 UK general practices in the West Midlands.Method: Using BP data collected for the two cohorts, three systolic BP phenotypes (dipper, non-dipper, and reverse dipper) were studied.Results: Among the hospital cohort, 48.9% (n= 10 610/21 716) patients were ‘reverse dippers’, with an average day–night systolic BP difference of +8.0 mmHg. Among the community (BP-Eth) cohort, 10.8% (n= 63/585) of patients were reverse dippers, with an average day–night systolic BP difference of +8.5 mmHg. Non-dipper and reverse-dipper phenotypes both had lower daytime systolic BP and higher night-time systolic BP than the dipper phenotype. Average daytime systolic BP was lowest in the reverse-dipping phenotype (this was 6.5 mmHg and 6.8 mmHg lower than for the dipper phenotype in the hospital and community cohorts, respectively), thereby placing them at risk of undiagnosed, or masked, hypertension.Conclusion: Not measuring night-time BP puts all groups, other than dippers, at risk of failure to identify hypertension. As a result of this study, it is recommended that GPs should offer ABPM to all patients aged ≥60 years as a minimum when assessing for hypertension.


  • Open Access

    Ambulatory blood pressure monitoring using telemedicine: proof-of-concept cohort and failure modes and effects analyses

    by Laura C. Armitage, Beth K. Lawson, Cristian Roman, Beth Thompson, Christopher Biggs, Heather Rutter, Martin Lewis-Jones, Jody Ede, Lionel Tarassenko, Andrew Farmer, et al.

    Background: The COVID-19 pandemic has accelerated adoption of remote consulting in healthcare. Despite opportunities posed by telemedicine, most hypertension services in Europe have suspended ambulatory blood pressure monitoring (ABPM). Methods: We examined the process and performance of remotely delivered ABPM using two methodologies: firstly, a Failure Modes and Effects Analysis (FMEA) and secondly, a quantitative analysis comparing ABPM data from a subgroup of 65 participants of the Screening for Hypertension in the INpatient Environment (SHINE) diagnostic accuracy study. The FMEA was performed over seven sessions from February to March 2021, with a multidisciplinary team comprising a patient representative, a research coordinator with technical expertise and four research clinicians. Results: The FMEA identified a single high-risk step in the remote ABPM process. This was cleaning of monitoring equipment in the context of the COVID-19 pandemic, unrelated to the remote setting. A total of 14 participants were scheduled for face-to-face ABPM appointments, before the UK March 2020 COVID-19 lockdown; 62 were scheduled for remote ABPM appointments since emergence of the COVID-19 pandemic between November 2020 and August 2021. A total of 65 (88%) participants completed ABPMs; all obtained sufficient successful measurements for interpretation. For the 10 participants who completed face-to-face ABPM, there were 402 attempted ABPM measurements and 361 (89%) were successful. For the 55 participants who completed remote ABPM, there were 2516 attempted measurements and 2214 (88%) were successful. There was no significant difference in the mean per-participant error rate between face-to-face (0.100, SD 0.009) and remote (0.143, SD 0.132) cohorts (95% CI for the difference -0.125 to 0.045 and two-tailed P-value 0.353). Conclusions: We have demonstrated that ABPM can be safely and appropriately provided in the community remotely and without face-to-face contact, using video technology for remote fitting appointments, alongside courier services for delivery of equipment to participants.


  • Open Access

    Ambulatory blood pressure monitoring using telemedicine: proof-of-concept cohort and failure modes and effects analyses

    by Laura C. Armitage, Beth K. Lawson, Cristian Roman, Beth Thompson, Christopher Biggs, Heather Rutter, Martin Lewis-Jones, Jody Ede, Lionel Tarassenko, Andrew Farmer, et al.

    Background: The COVID-19 pandemic has accelerated adoption of remote consulting in healthcare. Despite opportunities posed by telemedicine, most hypertension services in Europe have suspended ambulatory blood pressure monitoring (ABPM). Methods: We examined the process and performance of remotely delivered ABPM using two methodologies: firstly, a Failure Modes and Effects Analysis (FMEA) and secondly, a quantitative analysis comparing ABPM data from a subgroup of 65 participants of the Screening for Hypertension in the INpatient Environment (SHINE) diagnostic accuracy study. The FMEA was performed over seven sessions from February to March 2021, with a multidisciplinary team comprising a patient representative, a research coordinator with technical expertise and four research clinicians. Results: The FMEA identified a single high-risk step in the remote ABPM process. This was cleaning of monitoring equipment in the context of the COVID-19 pandemic, unrelated to the remote setting. A total of 14 participants were scheduled for face-to-face ABPM appointments, before the UK March 2020 COVID-19 lockdown; 62 were scheduled for remote ABPM appointments since emergence of the COVID-19 pandemic between November 2020 and August 2021. A total of 65 (88%) participants completed ABPMs; all obtained sufficient successful measurements for interpretation. For the 10 participants who completed face-to-face ABPM, there were 402 attempted ABPM measurements and 361 (89%) were successful. For the 55 participants who completed remote ABPM, there were 2516 attempted measurements and 2214 (88%) were successful. There was no significant difference in the mean per-participant error rate between face-to-face (0.100, SD 0.009) and remote (0.143, SD 0.132) cohorts (95% CI for the difference -0.125 to 0.045 and two-tailed P-value 0.353). Conclusions: We have demonstrated that ABPM can be safely and appropriately provided in the community remotely and without face-to-face contact, using video technology for remote fitting appointments, alongside courier services for delivery of equipment to participants.

  • Open Access

    Ambulatory blood pressure monitoring using telemedicine: proof-of-concept cohort and failure modes and effects analyses

    by Laura C. Armitage, Beth K. Lawson, Cristian Roman, Beth Thompson, Christopher Biggs, Heather Rutter, Martin Lewis-Jones, Jody Ede, Lionel Tarassenko, Andrew Farmer, et al.

    Background: The COVID-19 pandemic has accelerated adoption of remote consulting in healthcare. Despite opportunities posed by telemedicine, most hypertension services in Europe have suspended ambulatory blood pressure monitoring (ABPM). Methods: We examined the process and performance of remotely delivered ABPM using two methodologies: firstly, a Failure Modes and Effects Analysis (FMEA) and secondly, a quantitative analysis comparing ABPM data from a subgroup of 65 participants of the Screening for Hypertension in the INpatient Environment (SHINE) diagnostic accuracy study. The FMEA was performed over seven sessions from February to March 2021, with a multidisciplinary team comprising a patient representative, a research coordinator with technical expertise and four research clinicians. Results: The FMEA identified a single high-risk step in the remote ABPM process. This was cleaning of monitoring equipment in the context of the COVID-19 pandemic, unrelated to the remote setting. A total of 14 participants were scheduled for face-to-face ABPM appointments, before the UK March 2020 COVID-19 lockdown; 62 were scheduled for remote ABPM appointments since emergence of the COVID-19 pandemic between November 2020 and August 2021. A total of 65 (88%) participants completed ABPMs; all obtained sufficient successful measurements for interpretation. For the 10 participants who completed face-to-face ABPM, there were 402 attempted ABPM measurements and 361 (89%) were successful. For the 55 participants who completed remote ABPM, there were 2516 attempted measurements and 2114 (88%) were successful. There was no significant difference in the mean per-participant error rate between face-to-face (0.100, SD 0.009) and remote (0.143, SD 0.132) cohorts (95% CI for the difference -0.125 to 0.045 and two-tailed P-value 0.353). Conclusions: We have demonstrated that ABPM can be safely and appropriately provided in the community remotely and without face-to-face contact, using video technology for remote fitting appointments, alongside courier services for delivery of equipment to participants.

  • Open Access

    Association Between Blood Pressure Control and Coronavirus Disease 2019 Outcomes in 45 418 Symptomatic Patients With Hypertension

    by James P. Sheppard, Brian D. Nicholson, Joseph Lee, Dylan McGagh, Julian Sherlock, Constantinos Koshiaris, Jason Oke, Nicholas R. Jones, William Hinton, Laura Armitage, et al.

    Hypertension has been identified as a risk factor for coronavirus disease 2019 (COVID-19) and associated adverse outcomes. This study examined the association between preinfection blood pressure (BP) control and COVID-19 outcomes using data from 460 general practices in England. Eligible patients were adults with hypertension who were tested or diagnosed with COVID-19. BP control was defined by the most recent BP reading within 24 months of the index date (January 1, 2020). BP was defined as controlled (<130/80 mm Hg), raised (130/80–139/89 mm Hg), stage 1 uncontrolled (140/90–159/99 mm Hg), or stage 2 uncontrolled (≥160/100 mm Hg). The primary outcome was death within 28 days of COVID-19 diagnosis. Secondary outcomes were COVID-19 diagnosis and COVID-19–related hospital admission. Multivariable logistic regression was used to examine the association between BP control and outcomes. Of the 45 418 patients (mean age, 67 years; 44.7% male) included, 11 950 (26.3%) had controlled BP. These patients were older, had more comorbidities, and had been diagnosed with hypertension for longer. A total of 4277 patients (9.4%) were diagnosed with COVID-19 and 877 died within 28 days. Individuals with stage 1 uncontrolled BP had lower odds of COVID-19 death (odds ratio, 0.76 [95% CI, 0.62–0.92]) compared with patients with well-controlled BP. There was no association between BP control and COVID-19 diagnosis or hospitalization. These findings suggest BP control may be associated with worse COVID-19 outcomes, possibly due to these patients having more advanced atherosclerosis and target organ damage. Such patients may need to consider adhering to stricter social distancing, to limit the impact of COVID-19 as future waves of the pandemic occur.


  • Open Access

    Application of the National Institute for Health and Care Excellence Evidence Standards Framework for Digital Health Technologies in Assessing Mobile-Delivered Technologies for the Self-Management of Type 2 Diabetes Mellitus: Scoping Review

    by Jessica R Forsyth, Hannah Chase, Nia W Roberts, Laura C Armitage, Andrew J Farmer

    Background: There is a growing role of digital health technologies (DHTs) in the management of chronic health conditions, specifically type 2 diabetes. It is increasingly important that health technologies meet the evidence standards for health care settings. In 2019, the National Institute for Health and Care Excellence (NICE) published the NICE Evidence Standards Framework for DHTs. This provides guidance for evaluating the effectiveness and economic value of DHTs in health care settings in the United Kingdom. Objective: The aim of this study is to assess whether scientific articles on DHTs for the self-management of type 2 diabetes mellitus report the evidence suggested for implementation in clinical practice, as described in the NICE Evidence Standards Framework for DHTs. Methods: We performed a scoping review of published articles and searched 5 databases to identify systematic reviews and primary studies of mobile device–delivered DHTs that provide self-management support for adults with type 2 diabetes mellitus. The evidence reported within articles was assessed against standards described in the NICE framework. Results: The database search yielded 715 systematic reviews, of which, 45 were relevant and together included 59 eligible primary studies. Within these, there were 39 unique technologies. Using the NICE framework, 13 technologies met best practice standards, 3 met minimum standards only, and 23 technologies did not meet minimum standards. Conclusions: On the assessment of peer-reviewed publications, over half of the identified DHTs did not appear to meet the minimum evidence standards recommended by the NICE framework. The most common reasons for studies of DHTs not meeting these evidence standards included the absence of a comparator group, no previous justification of sample size, no measurable improvement in condition-related outcomes, and a lack of statistical data analysis. This report provides information that will enable researchers and digital health developers to address these limitations when designing, delivering, and reporting digital health technology research in the future.


  • Open Access

    Application of the National Institute for Health and Care Excellence Evidence Standards Framework for Digital Health Technologies in Assessing Mobile-Delivered Technologies for the Self-Management of Type 2 Diabetes Mellitus: Scoping Review (Preprint)

    by Jessica R Forsyth, Hannah Chase, Nia W Roberts, Laura C Armitage, Andrew J Farmer

    BACKGROUND There is a growing role of digital health technologies (DHTs) in the management of chronic health conditions, specifically type 2 diabetes. It is increasingly important that health technologies meet the evidence standards for health care settings. In 2019, the National Institute for Health and Care Excellence (NICE) published the NICE Evidence Standards Framework for DHTs. This provides guidance for evaluating the effectiveness and economic value of DHTs in health care settings in the United Kingdom. OBJECTIVE The aim of this study is to assess whether scientific articles on DHTs for the self-management of type 2 diabetes mellitus report the evidence suggested for implementation in clinical practice, as described in the NICE Evidence Standards Framework for DHTs. METHODS We performed a scoping review of published articles and searched 5 databases to identify systematic reviews and primary studies of mobile device–delivered DHTs that provide self-management support for adults with type 2 diabetes mellitus. The evidence reported within articles was assessed against standards described in the NICE framework. RESULTS The database search yielded 715 systematic reviews, of which, 45 were relevant and together included 59 eligible primary studies. Within these, there were 39 unique technologies. Using the NICE framework, 13 technologies met best practice standards, 3 met minimum standards only, and 23 technologies did not meet minimum standards. CONCLUSIONS On the assessment of peer-reviewed publications, over half of the identified DHTs did not appear to meet the minimum evidence standards recommended by the NICE framework. The most common reasons for studies of DHTs not meeting these evidence standards included the absence of a comparator group, no previous justification of sample size, no measurable improvement in condition-related outcomes, and a lack of statistical data analysis. This report provides information that will enable researchers and digital health developers to address these limitations when designing, delivering, and reporting digital health technology research in the future.

  • Open Access

    Monitoring activity of hip injury patients (MoHIP): a sub-study of the World Hip Trauma Evaluation observational cohort study

    by Laura C. Armitage, Yuan Chi, Mauro Santos, Beth K. Lawson, Carlos Areia, Carmelo Velardo, Peter J. Watkinson, Lionel Tarassenko, Matthew L. Costa, Andrew J. Farmer

    Background: Hip fracture is common, affecting 20% of women and 10% of men during their lifetime. The trajectory of patients’ recovery as they transition from the acute hospital setting to their usual residence is poorly understood. Recently, the use of activity trackers to monitor physical activity during recovery has been investigated as a way to explore this trajectory. Methods: This prospective observational cohort study followed patients from hospital to home as they recovered from a hip fracture. Participants were recruited from a single centre and provided with a 3-axis logging accelerometer worn as a pendant, for 16 weeks from recruitment. Participants received monthly follow-up visits which included questions about wearing the monitor. Monthly activity monitor data were also downloaded. Participant activity was estimated from the monitor data using the calibrated “Euclidean Norm Minus One” (ENMO) metric. Polynomial mixed-effects modelling was used to evaluate the difference between the weekly activity trends of 2 groups of participants: those with and without independent mobility at 16 weeks (defined by whether aids or personal assistance were required to mobilise). Results: Twenty-nine participants from 125 eligible patients were recruited. Of these, 19 (66%) reported being aware of wearing the monitor at least some of the time. Fourteen (48%) participants withdrew before study completion. Data for thirteen (45%) participants were of sufficient quantity to be included in the activity modelling procedure. Of these, 8 reported independent mobility at 16 weeks post-surgery, and 5 did not. By week 7, the weekly predicted mean ENMO ( $$ {\overline{ENMO}}_W $$ENMO¯W ) values were significantly different between the two participant groups, demonstrating feasibility of the model’s ability to predict which patients will report independent mobility at 16 weeks. Conclusions: This is the first study to our knowledge to investigate acceptability and feasibility of a pendant-worn activity monitor in this patient cohort. Acceptability of wearing the monitor and feasibility of recruitment and retention of participants were limited. Future research into the use of activity monitors in this population should use minimally intrusive devices which are acceptable to this population. Study registration: MoHIP is a sub-study of the World Hip Trauma Evaluation (WHiTE) Study (ISRCTN 63982700).