Cedric Malherbe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Cedric Malherbe has a total of 116 co-authors. Here are the top co-authors by number of shared publications:
- Gauthier Eppe
University of Liège
11 shared publications Gauthier Eppe
Mass Spectrometry Laboratory, MolSys Research Unit, University of Liège, Liege, Belgium
7 shared publications- Jean-Christophe M. Monbaliu
Center for Integrated Technology and Organic Synthesis, ULiege, 4000 Liège, Belgium
6 shared publications Ian B. Hutchinson
Department of Physics and Astronomy, University of Leicester, Leicester, UK
5 shared publicationsLucas Demaret
Mass Spectrometry Laboratory, MolSys Research Unit, University of Liège, Liege, Belgium
4 shared publicationsAlexandre Verdin
Mass Spectrometry Laboratory, MolSys Research Unit, Department of Chemistry, University of Liege
3 shared publications
Latest Publications
- Open Access
- 8 July 2026
- Published by Elsevier in SSRN Electronic Journal
Acid-free Hydrothermal Recycling of Waste Tires into Turbostratic Hard Carbon Anodes for Li, Na, and K-ion Batteries
Waste tire management is a worldwide problem causing severe environmental and health issues. The present study aimed at transforming waste tire granules (also called crumb rubber) into a hard carbon anode material for monovalent-ion batteries. The proposed O2-based oxidizing hydrothermal treatment was found to initiate the breaking of the vulcanized SBR, release the carbon black particles confined in the rubber matrix and favor the leaching of the inorganic fillers, including silica. This preliminary hydrothermal step facilitated the following pyrolysis step, which could be significantly reduced in duration compared with literature (<24 hours). The monitoring of Si, Zn, Ca, and Fe leaching performed by X-ray fluorescence and atomic absorption spectroscopy indicates a global leaching efficiency of up to 84.3%. Infrared spectroscopy on the solid residue and gas chromatography on the filtrate highlight the major presence of carbonyl functions and oxidized by-products, confirming the rubber degradation during the oxidative hydrothermal treatment. Raman spectroscopy and X-ray diffraction measurements reveal a typical turbostratic carbon framework after the pyrolytic step. This waste tire-derived hard carbon, when tested in half cells against Li, Na, and K, exhibited competitive electrochemical performances with a reversible capacity of 320 mAh/g vs Li+/Li, 190 mAh/g vs Na+/Na, and 245 mAh/g vs K+/K at a current density of 50 mA/g. Long-term cyclic experiments attested a cycling stability after 200 cycles. This O2-based hydrothermal process avoids the use of harsh conditions and large amounts of acids while allowing to recycle waste tires into a high-value-added carbonaceous material for energy storage technologies.
- 8 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessAcid-free Hydrothermal Recycling of Waste Tires into Turbostratic Hard Carbon Anodes for Li, Na, and K-ion Batteries
Waste tire management is a worldwide problem causing severe environmental and health issues. The present study aimed at transforming waste tire granules (also called crumb rubber) into a hard carbon anode material for monovalent-ion batteries. The proposed O2-based oxidizing hydrothermal treatment was found to initiate the breaking of the vulcanized SBR, release the carbon black particles confined in the rubber matrix and favor the leaching of the inorganic fillers, including silica. This preliminary hydrothermal step facilitated the following pyrolysis step, which could be significantly reduced in duration compared with literature (<24 hours). The monitoring of Si, Zn, Ca, and Fe leaching performed by X-ray fluorescence and atomic absorption spectroscopy indicates a global leaching efficiency of up to 84.3%. Infrared spectroscopy on the solid residue and gas chromatography on the filtrate highlight the major presence of carbonyl functions and oxidized by-products, confirming the rubber degradation during the oxidative hydrothermal treatment. Raman spectroscopy and X-ray diffraction measurements reveal a typical turbostratic carbon framework after the pyrolytic step. This waste tire-derived hard carbon, when tested in half cells against Li, Na, and K, exhibited competitive electrochemical performances with a reversible capacity of 320 mAh/g vs Li+/Li, 190 mAh/g vs Na+/Na, and 245 mAh/g vs K+/K at a current density of 50 mA/g. Long-term cyclic experiments attested a cycling stability after 200 cycles. This O2-based hydrothermal process avoids the use of harsh conditions and large amounts of acids while allowing to recycle waste tires into a high-value-added carbonaceous material for energy storage technologies.
- 3 January 2026
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 9 (2) , 1307-1318
Controlling Gold Nanoparticles Aggregation in Continuous-Flow Microreactors for Robust Production of Ultrasensitive NIR SERS Nanotags
- 3 January 2026
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 9 (2) , 1307-1318
Controlling Gold Nanoparticles Aggregation in Continuous-Flow Microreactors for Robust Production of Ultrasensitive NIR SERS Nanotags
- 22 December 2025
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 80 (5) , 516-527
Knife-Edge Technique Using Raman Spectrometers to Determine the Effective Laser Spot Size on Powders: Implications for Planetary Exploration
Raman spectroscopy is an analytical technique of choice for Earth and planetary sciences, which was recently selected as part of robotic exploration missions on Mars. Indeed, several miniaturized Raman spectrometers have been included into the scientific payload of rovers for the remote surface exploration of Mars: SuperCam and Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) for the NASA Mars 2020 mission and the Raman laser spectrometer (RLS) for the European Space Agency's (ESA) ExoMars mission. In preparation for these missions, a number of Mars analogue biogeological samples retrieved on Earth are extensively interrogated using Raman spectrometers, including flight prototype instruments but not only. Some studies also used flight representative portable instruments, as well as benchtop instruments. Commonly, authors reported the excitation laser wavelength and its power but often omitted the laser spot size on the sample which is a key factor for comparing several studies in term of spectrometer capabilities. In this study, we reported an easy, fast and universal experimental approach for determining the effective laser spot size, defined as the diameter of the sample section which is effectively probed by the Raman spectrometer during the analyses. Here, we characterized the effective laser spot size for a benchtop micro-Raman system and two different portable spectrometers, using a standard silicon wafer and gypsum powders with various average grain sizes. The dependence of the laser spot size with the grain size of the samples is discussed with regards to qualitative and quantitative analyses of solid dispersions in the scope of remote planetary missions.
- 22 December 2025
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 80 (5) , 516-527
Knife-Edge Technique Using Raman Spectrometers to Determine the Effective Laser Spot Size on Powders: Implications for Planetary Exploration
Raman spectroscopy is an analytical technique of choice for Earth and planetary sciences, which was recently selected as part of robotic exploration missions on Mars. Indeed, several miniaturized Raman spectrometers have been included into the scientific payload of rovers for the remote surface exploration of Mars: SuperCam and Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) for the NASA Mars 2020 mission and the Raman laser spectrometer (RLS) for the European Space Agency's (ESA) ExoMars mission. In preparation for these missions, a number of Mars analogue biogeological samples retrieved on Earth are extensively interrogated using Raman spectrometers, including flight prototype instruments but not only. Some studies also used flight representative portable instruments, as well as benchtop instruments. Commonly, authors reported the excitation laser wavelength and its power but often omitted the laser spot size on the sample which is a key factor for comparing several studies in term of spectrometer capabilities. In this study, we reported an easy, fast and universal experimental approach for determining the effective laser spot size, defined as the diameter of the sample section which is effectively probed by the Raman spectrometer during the analyses. Here, we characterized the effective laser spot size for a benchtop micro-Raman system and two different portable spectrometers, using a standard silicon wafer and gypsum powders with various average grain sizes. The dependence of the laser spot size with the grain size of the samples is discussed with regards to qualitative and quantitative analyses of solid dispersions in the scope of remote planetary missions.
- 10 July 2025
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 56 (11) , 1345-1352
Characterising the Composition of Olivine and Iron Oxides in a Sample of the Sericho Meteorite by Raman Spectroscopy Using Principal Component Analysis
Raman spectroscopy is a key technique for planetary exploration, providing mineralogical insights under strict constraints on power, mass and data transmission. This study applies principal component analysis (PCA) to Raman imaging data from the Sericho pallasite meteorite, composed mainly of Mg‐rich olivine and Fe‐Ni alloy. PCA efficiently reduced the complex dataset to only five principal components, retaining most of the molecular information. Using PCA scores, averaged Raman spectra were calculated to significantly simplify spectral interpretation, highlighting olivine as the dominant mineral and goethite, disordered hematite as well as disordered carbon as minor phases in the sample. In addition, PCA scores associated with the x‐y coordinate of the Raman image enable identification of distinct mineralogical domains, revealing the spatial distribution of iron oxyhydroxides primarily at interfaces and fractures of the olivine inclusions. Additionally, PCA‐filtered spectra enabled spatially resolved quantification of olivine composition, showing a 5%–10% magnesium enrichment in olivine cores compared to interfaces with iron oxyhydroxides, suggesting weathering origins of the Fe‐Ni alloy. These results demonstrate the strong potential of PCA for data reduction, visualization and interpretation of complex Raman datasets, making it a powerful tool for in situ mineralogical analysis during future robotic or human planetary missions where fast real‐time data processing is key for informed decision‐making.
- 10 July 2025
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 56 (11) , 1345-1352
Characterising the Composition of Olivine and Iron Oxides in a Sample of the Sericho Meteorite by Raman Spectroscopy Using Principal Component Analysis
Raman spectroscopy is a key technique for planetary exploration, providing mineralogical insights under strict constraints on power, mass and data transmission. This study applies principal component analysis (PCA) to Raman imaging data from the Sericho pallasite meteorite, composed mainly of Mg‐rich olivine and Fe‐Ni alloy. PCA efficiently reduced the complex dataset to only five principal components, retaining most of the molecular information. Using PCA scores, averaged Raman spectra were calculated to significantly simplify spectral interpretation, highlighting olivine as the dominant mineral and goethite, disordered hematite as well as disordered carbon as minor phases in the sample. In addition, PCA scores associated with the x‐y coordinate of the Raman image enable identification of distinct mineralogical domains, revealing the spatial distribution of iron oxyhydroxides primarily at interfaces and fractures of the olivine inclusions. Additionally, PCA‐filtered spectra enabled spatially resolved quantification of olivine composition, showing a 5%–10% magnesium enrichment in olivine cores compared to interfaces with iron oxyhydroxides, suggesting weathering origins of the Fe‐Ni alloy. These results demonstrate the strong potential of PCA for data reduction, visualization and interpretation of complex Raman datasets, making it a powerful tool for in situ mineralogical analysis during future robotic or human planetary missions where fast real‐time data processing is key for informed decision‐making.
- Open Access
- 25 June 2025
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 56 (11) , 1378-1385
Terrestrial Lithium Exploration Adapted From Raman Diagnosis of Phyllosilicates for Mars
Analyses using a benchtop Raman instrument at the University of Aberdeen and a prototype instrument for remote deployment on Mars based at the University of Leicester successfully discriminated between four varieties of mica. The mica minerals muscovite, biotite, lepidolite and zinnwaldite can be distinguished using a decision tree based on the peaks measured. The micas were measured in context within granites in Aberdeenshire, where the lithium‐bearing micas lepidolite and zinnwaldite confer anomalous enrichments in lithium to the host granites. Deployment of the prototype instrument in field conditions at two different sites successfully identified zinnwaldite and muscovite. Thereby, the technique accomplished the discrimination of lithium‐rich rocks. Experiments at a ‘blind’ site in the field, where the mica identification was unknown to the user, were partially successful. The data suggest that a portable instrument could be developed to allow the rapid detection of lithium‐bearing species. Raman spectroscopy has the potential to contribute to the exploration of one of the most important elements required in meeting a future green economy.
- 25 June 2025
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 56 (11) , 1378-1385
Open AccessTerrestrial Lithium Exploration Adapted From Raman Diagnosis of Phyllosilicates for Mars
Analyses using a benchtop Raman instrument at the University of Aberdeen and a prototype instrument for remote deployment on Mars based at the University of Leicester successfully discriminated between four varieties of mica. The mica minerals muscovite, biotite, lepidolite and zinnwaldite can be distinguished using a decision tree based on the peaks measured. The micas were measured in context within granites in Aberdeenshire, where the lithium‐bearing micas lepidolite and zinnwaldite confer anomalous enrichments in lithium to the host granites. Deployment of the prototype instrument in field conditions at two different sites successfully identified zinnwaldite and muscovite. Thereby, the technique accomplished the discrimination of lithium‐rich rocks. Experiments at a ‘blind’ site in the field, where the mica identification was unknown to the user, were partially successful. The data suggest that a portable instrument could be developed to allow the rapid detection of lithium‐bearing species. Raman spectroscopy has the potential to contribute to the exploration of one of the most important elements required in meeting a future green economy.
- 31 March 2025
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 56 (9) , 827-834
Influence of the Hammett Base Concentration on Acidity Levels in Ionic Liquids Using Raman Spectroscopy and Hammett Acidity Functions
Room‐temperature ionic liquids (RTILs) are a class of solvents with remarkable properties, including specific solvation properties and tuneable acidity levels. The Hammett acidity functions, commonly used to assess the acidity levels of ILs, rely on monitoring the protonation of colour indicators (especially nitroanilines) via UV‐visible spectroscopy. However, this method possesses certain limitations, prompting our group to adapt it in Raman spectroscopy in a previous study. Yet the influence of the indicator concentration on the acidity functions has never been thoroughly examined. In this article, we investigated the effect of the 2,4‐dichloro‐6‐nitroaniline concentration (from 7 to 50 mM) on the Hammett acidity functions estimated by Raman spectroscopy in 1‐butyl‐3‐methylimidazolium bistriflimide, [BMIm]NTf 2 . The acidity measured with this method was higher than the acidity evaluated via UV‐visible spectroscopy but lower than the acidity evaluated via Strehlow acidity functions, suggesting specific solvation effects of the nitroaniline in [BMIm]NTf 2 and the formation of ion pairs in this solvent, which are discussed in this paper.
- 31 March 2025
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 56 (9) , 827-834
Influence of the Hammett Base Concentration on Acidity Levels in Ionic Liquids Using Raman Spectroscopy and Hammett Acidity Functions
Room‐temperature ionic liquids (RTILs) are a class of solvents with remarkable properties, including specific solvation properties and tuneable acidity levels. The Hammett acidity functions, commonly used to assess the acidity levels of ILs, rely on monitoring the protonation of colour indicators (especially nitroanilines) via UV‐visible spectroscopy. However, this method possesses certain limitations, prompting our group to adapt it in Raman spectroscopy in a previous study. Yet the influence of the indicator concentration on the acidity functions has never been thoroughly examined. In this article, we investigated the effect of the 2,4‐dichloro‐6‐nitroaniline concentration (from 7 to 50 mM) on the Hammett acidity functions estimated by Raman spectroscopy in 1‐butyl‐3‐methylimidazolium bistriflimide, [BMIm]NTf 2 . The acidity measured with this method was higher than the acidity evaluated via UV‐visible spectroscopy but lower than the acidity evaluated via Strehlow acidity functions, suggesting specific solvation effects of the nitroaniline in [BMIm]NTf 2 and the formation of ion pairs in this solvent, which are discussed in this paper.
- Open Access
- 13 January 2025
- Published by American Chemical Society (ACS) in ACS Applied Electronic Materials
- Vol. 7 (2) , 643-651
Correlation between Material Properties, Crystalline Transitions, and Point Defects in RF Sputtered (N,Mg)-Doped Copper Oxide Thin Films
- 13 January 2025
- Published by American Chemical Society (ACS) in ACS Applied Electronic Materials
- Vol. 7 (2) , 643-651
Open AccessCorrelation between Material Properties, Crystalline Transitions, and Point Defects in RF Sputtered (N,Mg)-Doped Copper Oxide Thin Films
- 17 December 2024
- Published by Springer Nature
- p. 81-106
Raman Spectroscopy
- Open Access
- 6 December 2024
- Published by Royal Society of Chemistry (RSC) in Chemical Science
- Vol. 16 (2) , 980
Correction: An innovative chalcogenide transfer agent for improved aqueous quantum dot synthesis
Correction for ‘An innovative chalcogenide transfer agent for improved aqueous quantum dot synthesis’ by Guillaume Petit et al. , Chem. Sci. , 2024, 15 , 13148–13159, https://doi.org/10.1039/D4SC01135J.
- 6 December 2024
- Published by Royal Society of Chemistry (RSC) in Chemical Science
- Vol. 16 (2) , 980
Open AccessCorrection: An innovative chalcogenide transfer agent for improved aqueous quantum dot synthesis
Correction for ‘An innovative chalcogenide transfer agent for improved aqueous quantum dot synthesis’ by Guillaume Petit et al. , Chem. Sci. , 2024, 15 , 13148–13159, https://doi.org/10.1039/D4SC01135J.
- 4 December 2024
- Published by Royal Society of Chemistry (RSC) in Green Chemistry
- Vol. 27 (3) , 722-730
Rapid CO2 coupling to propargylic alcohols: unlocking the production of α-alkylidene cyclic carbonates via continuous flow
Silver N-heterocyclic carbene complex unlocks the fast coupling of CO2 to propargylic alcohols to produce α-alkylidene cyclic carbonates through continuous flow process.
- 4 December 2024
- Published by Royal Society of Chemistry (RSC) in Green Chemistry
- Vol. 27 (3) , 722-730
Rapid CO2 coupling to propargylic alcohols: unlocking the production of α-alkylidene cyclic carbonates via continuous flow
Silver N-heterocyclic carbene complex unlocks the fast coupling of CO2 to propargylic alcohols to produce α-alkylidene cyclic carbonates through continuous flow process.