Carlos Gustavo Castelo Branco
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Carlos Gustavo Castelo Branco has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Francisco Kleber de Araújo Lima
Department of Electrical Engineering, Federal University of Ceara, Fortaleza CE 60020-181, Brazil
4 shared publications - Fernando Lessa Tofoli
Department of Electrical Engineering, Federal University of São João del-Rei, São João del-Rei 36307-352, Brazil
3 shared publications - Jean Marcos Lobo da Fonseca
University of Houston, Houston, TX, USA
3 shared publications Francisco Kleber A. Lima
Federal University of Ceará,Fortaleza,Brazil
2 shared publications- Jose Matas
Department of Electrical Engineering, Universitat Politècnica de Catalunya, 08019 Barcelona, Spain
2 shared publications - Josep Maria Guerrero
Zhejiang University
2 shared publications
Latest Publications
- Open Access
A Unified Power Calculation Scheme for Single-Phase Droop-Based Inverters Considering the Use of Nonlinear Loads
The dynamic performance of droop-controlled single-phase voltage-source inverters (VSIs) strongly depends on the accurate and fast calculation of active (P) and reactive (Q) powers under nonlinear load (NLL) conditions. Existing PQ calculation methods have been developed independently, most using a second-order generalized integrator (SOGI) approach, masking their structural relationships. This paper introduces a unified framework that interprets these PQ calculation approaches as combinations of input filters, intermediate notch filters, and output low-pass filters, enabling a clear spectral-domain analysis. Using this framework, the paper reveals that the current-side orthogonal filter in the fastest previously reported method (PQ4) causes a reactive power undershoot during load transients due to insufficient filtering. To overcome this limitation, a novel scheme (PQ2m) relocates the orthogonal filter to the voltage side and adds current-side SOGI filtering for improved distortion rejection. Analytical dynamic modeling enables a systematic design procedure, achieving an overshoot-free, dominant second-order response. Furthermore, incorporating notch filters (NFs) yields the PQ2mn variant and alternative PQ2mnb and PQ2mnc designs, which significantly suppress the output ripple while further accelerating the response speed. Hardware-in-the-Loop (HIL) results confirm settling-time reductions of up to 92.9% (PQ2m/PQ2mn), 95.75% (PQ2mnb), and 96.9% (PQ2mnc) compared to the conventional PQ1 method. Among all configurations, PQ2mn provides the best overall trade-off between dynamic enhancement and computational complexity.
Open AccessA Unified Power Calculation Scheme for Single-Phase Droop-Based Inverters Considering the Use of Nonlinear Loads
The dynamic performance of droop-controlled single-phase voltage-source inverters (VSIs) strongly depends on the accurate and fast calculation of active (P) and reactive (Q) powers under nonlinear load (NLL) conditions. Existing PQ calculation methods have been developed independently, most using a second-order generalized integrator (SOGI) approach, masking their structural relationships. This paper introduces a unified framework that interprets these PQ calculation approaches as combinations of input filters, intermediate notch filters, and output low-pass filters, enabling a clear spectral-domain analysis. Using this framework, the paper reveals that the current-side orthogonal filter in the fastest previously reported method (PQ4) causes a reactive power undershoot during load transients due to insufficient filtering. To overcome this limitation, a novel scheme (PQ2m) relocates the orthogonal filter to the voltage side and adds current-side SOGI filtering for improved distortion rejection. Analytical dynamic modeling enables a systematic design procedure, achieving an overshoot-free, dominant second-order response. Furthermore, incorporating notch filters (NFs) yields the PQ2mn variant and alternative PQ2mnb and PQ2mnc designs, which significantly suppress the output ripple while further accelerating the response speed. Hardware-in-the-Loop (HIL) results confirm settling-time reductions of up to 92.9% (PQ2m/PQ2mn), 95.75% (PQ2mnb), and 96.9% (PQ2mnc) compared to the conventional PQ1 method. Among all configurations, PQ2mn provides the best overall trade-off between dynamic enhancement and computational complexity.
- Open Access
A Fast Power Calculation Algorithm for Three-Phase Droop-Controlled-Inverters Using Combined SOGI Filters and Considering Nonlinear Loads
The power calculation is an indispensable element in droop-controlled inverters because the bandwidth of the measured power has a direct impact on the controller performance. This paper proposes a fast and accurate power calculation algorithm based on the combined Second Order Generalized Integrator (SOGI) filters in stationary coordinates for a three-phase system, which takes into consideration the use of nonlinear loads. The power calculation scheme is formed by the two-stage SOGI filters that are employed for obtaining the active and reactive powers required to perform a droop-based inverter operation, respectively. From the two-stage structure, the first SOGI is used as a band-pass filter (BPF) for filtering harmonics and obtaining the fundamental current of the nonlinear load; The second SOGI is used as a low-pass filter (LPF) for extracting the DC-component, which corresponds with the average power. A small-signal model of a two droop-controlled inverters system is built to obtain the dynamical response and stability margin of the system. And compared it with the dynamical behaviour of a standard droop-control method. Next, the proposed power calculation system is designed in order to achieve the same ripple amplitude voltage as that obtained with the standard droop-control method by adjusting the bandwidth gains. Through simulation and hardware in the loop (HIL) validation, the proposed approach presents a faster and more accurate performance when sharing nonlinear loads, and also drives the inverters’ output voltage with lower distortion.
Open AccessA Fast Power Calculation Algorithm for Three-Phase Droop-Controlled-Inverters Using Combined SOGI Filters and Considering Nonlinear Loads
The power calculation is an indispensable element in droop-controlled inverters because the bandwidth of the measured power has a direct impact on the controller performance. This paper proposes a fast and accurate power calculation algorithm based on the combined Second Order Generalized Integrator (SOGI) filters in stationary coordinates for a three-phase system, which takes into consideration the use of nonlinear loads. The power calculation scheme is formed by the two-stage SOGI filters that are employed for obtaining the active and reactive powers required to perform a droop-based inverter operation, respectively. From the two-stage structure, the first SOGI is used as a band-pass filter (BPF) for filtering harmonics and obtaining the fundamental current of the nonlinear load; The second SOGI is used as a low-pass filter (LPF) for extracting the DC-component, which corresponds with the average power. A small-signal model of a two droop-controlled inverters system is built to obtain the dynamical response and stability margin of the system. And compared it with the dynamical behaviour of a standard droop-control method. Next, the proposed power calculation system is designed in order to achieve the same ripple amplitude voltage as that obtained with the standard droop-control method by adjusting the bandwidth gains. Through simulation and hardware in the loop (HIL) validation, the proposed approach presents a faster and more accurate performance when sharing nonlinear loads, and also drives the inverters’ output voltage with lower distortion.
- 1 March 2021
- Published by Elsevier in Electric Power Systems Research
- Vol. 192, 106924
Three-phase phase-locked loop algorithm and application to a static synchronous compensator
- 1 March 2021
- Published by Elsevier in Electric Power Systems Research
- Vol. 192, 106924
Three-phase phase-locked loop algorithm and application to a static synchronous compensator
- 1 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 1-6
A Novel Phase-Locked Loop with Positive and Negative Sequence Detection Capability
This paper proposes the expansion of two phase-locked loop structures to detect positive and negative sequence components. The first structure is a positive sequence detector only and the second one is a modification of the first one where an adaptive filter is added to increase filtering capability in scenarios with interharmonic distortion. Both proposed structures were implemented in the hardware-in-the-loop (HIL) dSPACE 1103 platform together with two well known structures, the DSOGI-FLL and the DDSRF-PLL. Steady-state and dynamic response of each structure were analyzed in scenarios with either harmonic distortion only or harmonic and interharmonic distortion. Results showed that the proposed structures are highly accurate, specifically under harmonic distortion, however the structure with adaptive filter is slower. In addition, results showed that the structures are at least as precise and fast as the DSOGI-FLL and DDSRF-PLL. Lastly, under interharmonic distortion, it is also found that the PLL with adaptive filter has an overall better performance.
- 1 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 1-6
A Novel Phase-Locked Loop with Positive and Negative Sequence Detection Capability
This paper proposes the expansion of two phase-locked loop structures to detect positive and negative sequence components. The first structure is a positive sequence detector only and the second one is a modification of the first one where an adaptive filter is added to increase filtering capability in scenarios with interharmonic distortion. Both proposed structures were implemented in the hardware-in-the-loop (HIL) dSPACE 1103 platform together with two well known structures, the DSOGI-FLL and the DDSRF-PLL. Steady-state and dynamic response of each structure were analyzed in scenarios with either harmonic distortion only or harmonic and interharmonic distortion. Results showed that the proposed structures are highly accurate, specifically under harmonic distortion, however the structure with adaptive filter is slower. In addition, results showed that the structures are at least as precise and fast as the DSOGI-FLL and DDSRF-PLL. Lastly, under interharmonic distortion, it is also found that the PLL with adaptive filter has an overall better performance.
- Open Access
Providing Ancillary Services with Wind Turbine Generators Based on DFIG with a Two-Branch Static Converter
This work aims to analyze and validate through mathematical modeling and experimental results, in a three-phase three-wire electrical system, the technical viability of a static power converter with a two-level topology with only two controlled branches (2L2B), operating as a grid-side converter (GSC) in a wind turbine generator based on a doubly fed induction generator (DFIG). With this reduced-switches topology, the GSC is able to regulate the DC-link voltage level from the generator back-to-back converter and provide ancillary services of harmonic filtering and reactive power compensation from linear/nonlinear loads connected to the point of common coupling. An 8-kVA experimental prototype was implemented in the laboratory to validate the proposal. The prototype control system was realized using the dSPACE DS1103 PPC Controller Board platform programmed via MATLAB/Simulink. The effectiveness of the proposed system is verified by comparing the results obtained with the 2L2B topology to the ones with the usual two-level three-branch topology.
Open AccessProviding Ancillary Services with Wind Turbine Generators Based on DFIG with a Two-Branch Static Converter
This work aims to analyze and validate through mathematical modeling and experimental results, in a three-phase three-wire electrical system, the technical viability of a static power converter with a two-level topology with only two controlled branches (2L2B), operating as a grid-side converter (GSC) in a wind turbine generator based on a doubly fed induction generator (DFIG). With this reduced-switches topology, the GSC is able to regulate the DC-link voltage level from the generator back-to-back converter and provide ancillary services of harmonic filtering and reactive power compensation from linear/nonlinear loads connected to the point of common coupling. An 8-kVA experimental prototype was implemented in the laboratory to validate the proposal. The prototype control system was realized using the dSPACE DS1103 PPC Controller Board platform programmed via MATLAB/Simulink. The effectiveness of the proposed system is verified by comparing the results obtained with the 2L2B topology to the ones with the usual two-level three-branch topology.
- 23 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 66 (12) , 9260-9267
A Phase-Locked Loop Algorithm for Single-Phase Systems With Inherent Disturbance Rejection
This work presents a phase-locked loop (PLL) algorithm adequate for applications regarding single-phase power grids. The proposed approach is based on the correlation of the input signal with a complex one obtained from an adaptive filter aiming at minimizing computational burden and increase accuracy if compared with a former algorithm previously proposed in literature. Thus it is possible to obtain high disturbance rejection, especially when dealing with the presence of subharmonics and interharmonics in the frequency spectrum of the supply voltage. Performance is thoroughly evaluated through experimental tests considering both steady-state and dynamic behaviors, while a proper comparison is established with other similar solutions.
- 23 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 66 (12) , 9260-9267
A Phase-Locked Loop Algorithm for Single-Phase Systems With Inherent Disturbance Rejection
This work presents a phase-locked loop (PLL) algorithm adequate for applications regarding single-phase power grids. The proposed approach is based on the correlation of the input signal with a complex one obtained from an adaptive filter aiming at minimizing computational burden and increase accuracy if compared with a former algorithm previously proposed in literature. Thus it is possible to obtain high disturbance rejection, especially when dealing with the presence of subharmonics and interharmonics in the frequency spectrum of the supply voltage. Performance is thoroughly evaluated through experimental tests considering both steady-state and dynamic behaviors, while a proper comparison is established with other similar solutions.
- Open Access
Synchronous Compensator Based on Doubly Fed Induction Generator to Improve the Power Quality under Unbalanced Grid Voltage Conditions
Currently, power quality is a major issue for all sorts of customers. End users of the electricity service in industrial, commercial and residential sectors have nonlinear loads or loads that are sensitive to disturbances in the electric power supply. In this context, this paper presents a study on four different control strategies for the application of synchronous compensator based on a doubly-fed induction generator (DFIG). The mathematical modeling developed to support the proposal of this article is validated through computational simulations and experimental results. This work contains strong arguments that support the idea that the proposed synchronous compensator can be employed to cancel oscillations caused by imbalances in the grid, and can furthermore inject or absorb reactive and active power without the characteristic oscillations that arise when negative sequence components are present in the system.
Open AccessSynchronous Compensator Based on Doubly Fed Induction Generator to Improve the Power Quality under Unbalanced Grid Voltage Conditions
Currently, power quality is a major issue for all sorts of customers. End users of the electricity service in industrial, commercial and residential sectors have nonlinear loads or loads that are sensitive to disturbances in the electric power supply. In this context, this paper presents a study on four different control strategies for the application of synchronous compensator based on a doubly-fed induction generator (DFIG). The mathematical modeling developed to support the proposal of this article is validated through computational simulations and experimental results. This work contains strong arguments that support the idea that the proposed synchronous compensator can be employed to cancel oscillations caused by imbalances in the grid, and can furthermore inject or absorb reactive and active power without the characteristic oscillations that arise when negative sequence components are present in the system.
- 1 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2952-2958
Performance analysis of synchronization algorithms for grid-connected power converters under sub and inter-harmonics distortion
This paper analyzes the performance of two synchronization algorithms, the EPLL and the ISI-PLL, under scenarios where inter-harmonics and sub-harmonics distortion are present in the input signals. Synchronization algorithms main goals are to estimate, with high accuracy, power grid parameters such as frequency and phase-angle. The EPLL is a well-known structure that is widely studied in the literature, whereas the ISI-PLL is a recent proposal. In order to obtain experimental results, both structures were implemented in the hardware-in-the-loop (HIL) dSPACE 1103 platform. Results showed that where the proposed structure is highly accurate under the considered scenarios, the EPLL estimation is not as precise.
- 1 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2952-2958
Performance analysis of synchronization algorithms for grid-connected power converters under sub and inter-harmonics distortion
This paper analyzes the performance of two synchronization algorithms, the EPLL and the ISI-PLL, under scenarios where inter-harmonics and sub-harmonics distortion are present in the input signals. Synchronization algorithms main goals are to estimate, with high accuracy, power grid parameters such as frequency and phase-angle. The EPLL is a well-known structure that is widely studied in the literature, whereas the ISI-PLL is a recent proposal. In order to obtain experimental results, both structures were implemented in the hardware-in-the-loop (HIL) dSPACE 1103 platform. Results showed that where the proposed structure is highly accurate under the considered scenarios, the EPLL estimation is not as precise.