James R. Ottewill has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Nina Frances Thornhill
Department of Chemical Engineering, Imperial College London, London, U.K.
5 shared publications - Anna Stief
ABB Corporate Research Center, ul. Starowislna 13a, 31-038, Krakow, Poland
3 shared publications - Ruomu Tan
Corporate Research Center, ABB AG, Ladenburg, Germany
3 shared publications - Jerzy Baranowski
Department of Automatic Control & Robotics, AGH University of Kraków, 30-059 Kraków, Poland
2 shared publications - Andrew Starr
School of Aerospace, Transport and Manufacturing, Cranfield University, Cranfield, UK
1 shared publication - Cristobal Ruiz-Carcel
Cranfield University
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 1
Ensemble based Self-Supervised Meta-Learning for Anomaly Detection in Power Systems
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 1
Open AccessEnsemble based Self-Supervised Meta-Learning for Anomaly Detection in Power Systems
- Open Access
- 11 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 139411-139426
Electrical Power Management by Flexible Operation of a Continuous Gas Export Plant
Industrial electrification provides a motivation to explore new methods for electrical power management within a large industrial site. This paper addresses the situation where the available power is not enough to meet the full demand of the site, which can happen because of an electrical contingency. An industrial power management system typically handles electrical power deficits by disconnecting equipment, also known as load shedding. However, disconnections can cause an industrial process to shut down giving a very significant negative economic impact. Using a gas export plant as an example, this paper shows that flexible operation of the plant offers an exciting alternative to disconnection. The main message of the work is that power management by flexible operation makes optimal use of any remaining available power, avoids load shedding, and enables an electricity-intensive process to ride through a contingency without an expensive shut-down. Instead of load shedding, the electrical drives force an immediate partial reduction of the power available to electrical motors and other machinery on a timescale similar to that of a circuit breaker. An innovation of the research is a framework for determining a feasible flexible operating point of the process that matches the magnitude of the partial reduction. Technology suitable for industrial implementation is identified in the article and practical considerations are addressed. The findings are expected to lead to the development and implementation of new systems for managing electrical power in electricity-intensive sites.
- 11 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 139411-139426
Open AccessElectrical Power Management by Flexible Operation of a Continuous Gas Export Plant
Industrial electrification provides a motivation to explore new methods for electrical power management within a large industrial site. This paper addresses the situation where the available power is not enough to meet the full demand of the site, which can happen because of an electrical contingency. An industrial power management system typically handles electrical power deficits by disconnecting equipment, also known as load shedding. However, disconnections can cause an industrial process to shut down giving a very significant negative economic impact. Using a gas export plant as an example, this paper shows that flexible operation of the plant offers an exciting alternative to disconnection. The main message of the work is that power management by flexible operation makes optimal use of any remaining available power, avoids load shedding, and enables an electricity-intensive process to ride through a contingency without an expensive shut-down. Instead of load shedding, the electrical drives force an immediate partial reduction of the power available to electrical motors and other machinery on a timescale similar to that of a circuit breaker. An innovation of the research is a framework for determining a feasible flexible operating point of the process that matches the magnitude of the partial reduction. Technology suitable for industrial implementation is identified in the article and practical considerations are addressed. The findings are expected to lead to the development and implementation of new systems for managing electrical power in electricity-intensive sites.
- 16 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 29 (5) , 2192-2205
Anomaly Detection and Mode Identification in Multimode Processes Using the Field Kalman Filter
- 16 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 29 (5) , 2192-2205
Anomaly Detection and Mode Identification in Multimode Processes Using the Field Kalman Filter
- Open Access
- 1 January 2020
- Published by Elsevier in Control Engineering Practice
- Vol. 94, 104195
Fault detection and identification combining process measurements and statistical alarms
- 1 January 2020
- Published by Elsevier in Control Engineering Practice
- Vol. 94, 104195
Open AccessFault detection and identification combining process measurements and statistical alarms
- Open Access
- 11 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Networks and Learning Systems
- Vol. 31 (9) , 3670-3681
Nonstationary Discrete Convolution Kernel for Multimodal Process Monitoring
Data-driven process monitoring has benefited from the development and application of kernel transformations, especially when various types of nonlinearity exist in the data. However, when dealing with the multimodality behavior that is frequently observed in the process operations, the most widely used radial basis function (RBF) kernel has limitations in describing process data collected from multiple normal operating modes. In this article, we highlight this limitation via a synthesized example. In order to account for the multimodality behavior and improve the fault detection performance accordingly, we propose a novel nonstationary discrete convolution kernel, which derives from the convolution kernel structure, as an alternative to the RBF kernel. By assuming the training samples to be the support of the discrete convolution, this new kernel can properly address these training samples from different operating modes with diverse properties and, therefore, can improve the data description and fault detection performance. Its performance is compared with RBF kernels under a standard kernel principal component analysis framework and with other methods proposed for multimode process monitoring via numerical examples. Moreover, a benchmark data set collected from a pilot-scale multiphase flow facility is used to demonstrate the advantages of the new kernel when applied to an experimental data set.
- 11 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Networks and Learning Systems
- Vol. 31 (9) , 3670-3681
Open AccessNonstationary Discrete Convolution Kernel for Multimodal Process Monitoring
Data-driven process monitoring has benefited from the development and application of kernel transformations, especially when various types of nonlinearity exist in the data. However, when dealing with the multimodality behavior that is frequently observed in the process operations, the most widely used radial basis function (RBF) kernel has limitations in describing process data collected from multiple normal operating modes. In this article, we highlight this limitation via a synthesized example. In order to account for the multimodality behavior and improve the fault detection performance accordingly, we propose a novel nonstationary discrete convolution kernel, which derives from the convolution kernel structure, as an alternative to the RBF kernel. By assuming the training samples to be the support of the discrete convolution, this new kernel can properly address these training samples from different operating modes with diverse properties and, therefore, can improve the data description and fault detection performance. Its performance is compared with RBF kernels under a standard kernel principal component analysis framework and with other methods proposed for multimode process monitoring via numerical examples. Moreover, a benchmark data set collected from a pilot-scale multiphase flow facility is used to demonstrate the advantages of the new kernel when applied to an experimental data set.
- Open Access
- 14 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 66 (12) , 9510-9520
A PCA and Two-Stage Bayesian Sensor Fusion Approach for Diagnosing Electrical and Mechanical Faults in Induction Motors
Induction motors are widely used in industrial plants for critical operations. Stator faults, bearing faults or rotor faults can lead to unplanned downtime with associated cost and safety implications. Different sensors may be used to monitor the health state of induction motors with each sensor typically being better suited to diagnosing different faults. Condition monitoring approaches which fuse data from multiple sensors have the potential to diagnose a greater number of faults. A sensor fusion approach based on the combination of a two-stage Bayesian method and Principal Component Analysis is proposed for diagnosing both electrical and mechanical faults in induction motors. Acoustic, electric and vibration signals are gathered from motors operating under different loading conditions and health states. The inclusion of the PCA step ensures robustness to varying loading conditions. The obtained results highlight that the proposed method performs better than equivalent single stage or feature-based Bayesian methods.
- 14 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 66 (12) , 9510-9520
Open AccessA PCA and Two-Stage Bayesian Sensor Fusion Approach for Diagnosing Electrical and Mechanical Faults in Induction Motors
Induction motors are widely used in industrial plants for critical operations. Stator faults, bearing faults or rotor faults can lead to unplanned downtime with associated cost and safety implications. Different sensors may be used to monitor the health state of induction motors with each sensor typically being better suited to diagnosing different faults. Condition monitoring approaches which fuse data from multiple sensors have the potential to diagnose a greater number of faults. A sensor fusion approach based on the combination of a two-stage Bayesian method and Principal Component Analysis is proposed for diagnosing both electrical and mechanical faults in induction motors. Acoustic, electric and vibration signals are gathered from motors operating under different loading conditions and health states. The inclusion of the PCA step ensures robustness to varying loading conditions. The obtained results highlight that the proposed method performs better than equivalent single stage or feature-based Bayesian methods.
- 8 October 2018
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 51 (18) , 363-368
Analytics of Heterogeneous Process Data: Multiphase Flow Facility Case Study
- 8 October 2018
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 51 (18) , 363-368
Analytics of Heterogeneous Process Data: Multiphase Flow Facility Case Study
- Open Access
- 30 June 2018
- Published by PHM Society in Phm Society European Conference
- Vol. 4 (1)
Vibration-based Rotorcraft Gearbox Monitoring Under Varying Operating Conditions
Modern rotorcrafts rely on Health and Usage Monitoring Systems (HUMS) to enhance their availability, reliability and safety. The complexity of the transmission system of new helicopter designs such as the Airbus Racer provides additional challenges for HUMS. The work presented here demonstrates a vibration-based monitoring approach for the lateral gearboxes of the racer. This approach relies on the statistical analysis of different condition indicators (CIs) extracted from vibration signals under different operating regimes to define a baseline for these CIs during normal operation. This permits the normalization of CIs from newly acquired signals with respect to the expected baseline value, facilitating the detection of anomalies in the signal characteristics for a variety of operating regimes. The monitoring capabilities of the proposed approach are tested using experimental data where the vibration response to different mechanical malfunctions was artificially seeded in to the acquired signals.
- 30 June 2018
- Published by PHM Society in Phm Society European Conference
- Vol. 4 (1)
Open AccessVibration-based Rotorcraft Gearbox Monitoring Under Varying Operating Conditions
Modern rotorcrafts rely on Health and Usage Monitoring Systems (HUMS) to enhance their availability, reliability and safety. The complexity of the transmission system of new helicopter designs such as the Airbus Racer provides additional challenges for HUMS. The work presented here demonstrates a vibration-based monitoring approach for the lateral gearboxes of the racer. This approach relies on the statistical analysis of different condition indicators (CIs) extracted from vibration signals under different operating regimes to define a baseline for these CIs during normal operation. This permits the normalization of CIs from newly acquired signals with respect to the expected baseline value, facilitating the detection of anomalies in the signal characteristics for a variety of operating regimes. The monitoring capabilities of the proposed approach are tested using experimental data where the vibration response to different mechanical malfunctions was artificially seeded in to the acquired signals.
- Open Access
- 18 October 2015
- Published by PHM Society in Annual Conference of the PHM Society
- Vol. 7 (1)
Adapting nearest neighbors-based monitoring methods to irregularly sampled measurements
Irregularly spaced measurements are a common quality problem in real data and preclude the use of several feature ex- traction methods, which were developed for measurements with constant sampling intervals. Feature extraction methods based on nearest neighbors of embedded vectors are an example of such methods. This paper proposes the use of a time- based construction of embedded vectors and a weighted similarity metric within nearest neighbor-based methods in order to extend their applicability to irregularly sampled measurements. The proposed idea is demonstrated within a method of univariate detection of transient or spiky disturbances. The result obtained with an irregularly sampled measurement is benchmarked by the original regularly sampled measurement. Although the method was originally implemented for off-line analysis, the paper also discusses modifications to enable its online implementation.
- 18 October 2015
- Published by PHM Society in Annual Conference of the PHM Society
- Vol. 7 (1)
Open AccessAdapting nearest neighbors-based monitoring methods to irregularly sampled measurements
Irregularly spaced measurements are a common quality problem in real data and preclude the use of several feature ex- traction methods, which were developed for measurements with constant sampling intervals. Feature extraction methods based on nearest neighbors of embedded vectors are an example of such methods. This paper proposes the use of a time- based construction of embedded vectors and a weighted similarity metric within nearest neighbor-based methods in order to extend their applicability to irregularly sampled measurements. The proposed idea is demonstrated within a method of univariate detection of transient or spiky disturbances. The result obtained with an irregularly sampled measurement is benchmarked by the original regularly sampled measurement. Although the method was originally implemented for off-line analysis, the paper also discusses modifications to enable its online implementation.