Liping Yan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Liping Yan has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Haisheng Chen
Institute of Engineering Thermophysics, Chinese Academy of Sciences
2 shared publications Chun-Qing Tan
1 shared publicationChunqing Tan
Institute of Engineering Thermophysics Chinese Academy of Sciences, Beijing, Beijing, CHINA
1 shared publicationDe-Tang Zeng
1 shared publicationHai-Sheng Chen
1 shared publicationHua-Liang Zhang
1 shared publication
Latest Publications
- Open Access
- 16 July 2021
- Published by ASME International
A Feature Weighted Kernel Extreme Learning Machine Ensemble Method for Gas Turbine Fault Diagnosis
Gas turbine is very popular in aviation, power system and many other fields due to its large power density, short loading time, low frequency noise, and favorable emission performance. Gas turbine usually works in high velocity, high temperature and high pressure environment, which is susceptible to corrosion, erosion, and foreign object damage as well as other physical problems.
- 16 July 2021
- Published by ASME International
Open AccessA Feature Weighted Kernel Extreme Learning Machine Ensemble Method for Gas Turbine Fault Diagnosis
Gas turbine is very popular in aviation, power system and many other fields due to its large power density, short loading time, low frequency noise, and favorable emission performance. Gas turbine usually works in high velocity, high temperature and high pressure environment, which is susceptible to corrosion, erosion, and foreign object damage as well as other physical problems.
- 9 June 2021
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 32 (9) , 095905
Unscented Kalman-filter-based simultaneous diagnostic scheme for gas-turbine gas path and sensor faults
Sensor faults can cause incorrect estimations of gas path fault amplitudes in gas turbines. In this paper, an unscented Kalman-filter (UKF)-based simultaneous diagnostic scheme for gas-turbine gas path and sensor faults is proposed. A fault detection and isolation (FDI) system based on the UKF method avoids the requirement to establish different hypothetical models for hierarchical multiple-model-based FDI. Moreover, a fault identification module based on the weighted sum of squared residuals from a bank of filters is proposed to confirm the actual fault. The corresponding fault amplitude is then estimated to adaptively update the related parameters of the fault-diagnosis system according to the actual determined fault. Finally, several simulation case studies are conducted, based on a three-shaft gas turbine. The simulation results show that when two faults coincide, the proposed scheme not only has diagnostic accuracies of 97.3% and 93% for sensor faults and gas path faults, respectively, but also estimates the fault magnitude to a high degree of accuracy.
- 9 June 2021
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 32 (9) , 095905
Unscented Kalman-filter-based simultaneous diagnostic scheme for gas-turbine gas path and sensor faults
Sensor faults can cause incorrect estimations of gas path fault amplitudes in gas turbines. In this paper, an unscented Kalman-filter (UKF)-based simultaneous diagnostic scheme for gas-turbine gas path and sensor faults is proposed. A fault detection and isolation (FDI) system based on the UKF method avoids the requirement to establish different hypothetical models for hierarchical multiple-model-based FDI. Moreover, a fault identification module based on the weighted sum of squared residuals from a bank of filters is proposed to confirm the actual fault. The corresponding fault amplitude is then estimated to adaptively update the related parameters of the fault-diagnosis system according to the actual determined fault. Finally, several simulation case studies are conducted, based on a three-shaft gas turbine. The simulation results show that when two faults coincide, the proposed scheme not only has diagnostic accuracies of 97.3% and 93% for sensor faults and gas path faults, respectively, but also estimates the fault magnitude to a high degree of accuracy.
- 25 October 2019
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 31 (1) , 015015
A fault diagnosis method for gas turbines based on improved data preprocessing and an optimization deep belief network
A classifier trained by a normalized simulation parameter could not identify an actual fault. In order to solve this problem, improved data preprocessing is proposed which normalizes the deviation of the simulation parameter, thus making preprocessed simulation data more accurate at revealing the performance of an actual gas turbine. Furthermore, an optimization deep belief network (DBN) based on a genetic algorithm is developed, which shows a good classification ability. The superiority of these two methods is validated respectively by a three-shaft gas turbine platform. It has also been found that based on the DBN optimization method, adding outlet temperature parameter T 3 to a high-pressure compressor can significantly improve diagnostic accuracy, increasing it by 10.1%. Finally, the fault experimental result validates the effectiveness of improved data preprocessing combined with an optimization DBN to diagnose faults in actual gas turbines.
- 25 October 2019
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 31 (1) , 015015
A fault diagnosis method for gas turbines based on improved data preprocessing and an optimization deep belief network
A classifier trained by a normalized simulation parameter could not identify an actual fault. In order to solve this problem, improved data preprocessing is proposed which normalizes the deviation of the simulation parameter, thus making preprocessed simulation data more accurate at revealing the performance of an actual gas turbine. Furthermore, an optimization deep belief network (DBN) based on a genetic algorithm is developed, which shows a good classification ability. The superiority of these two methods is validated respectively by a three-shaft gas turbine platform. It has also been found that based on the DBN optimization method, adding outlet temperature parameter T 3 to a high-pressure compressor can significantly improve diagnostic accuracy, increasing it by 10.1%. Finally, the fault experimental result validates the effectiveness of improved data preprocessing combined with an optimization DBN to diagnose faults in actual gas turbines.