Yixuan Zhao
Yixuan Zhao has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Cheng Guo
4 shared publicationsJiubin Tan
3 shared publications- Zhengjun Liu
Harbin Institute of Technology
3 shared publications Jian Liu
2 shared publicationsShutian Liu
2 shared publicationsWeisong Zhao
2 shared publications
Latest Publications
- 27 September 2022
- Published by Elsevier in Optics Communications
- Vol. 528
Miniaturized light-field endoscope via a GRIN lens array
- 27 September 2022
- Published by Elsevier in Optics Communications
- Vol. 528
Miniaturized light-field endoscope via a GRIN lens array
- 5 August 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (17) , 23814-23829
Robust autofocusing method for multi-wavelength lensless imaging
Lensless imaging based on multi-wavelength phase retrieval becomes a promising technology widely used as it has simple acquisition, miniaturized size and low-cost setup. However, measuring the sample-to-sensor distance with high accuracy, which is the key for high-resolution reconstruction, is still a challenge. In this work, we propose a multiwavelength criterion to realize autofocusing modulation, i.e., achieving much higher accuracy in determining the sample-to-sensor distance, compared to the conventional methods. Three beams in different spectrums are adopted to illuminate the sample, and the resulting holograms are recorded by a CCD camera. The patterns calculated by performing back propagation of the recorded holograms, with exhaustively searched sample-to-sensor distance value, are adopted to access the criterion. Image sharpness can be accessed and the optimal sample-to-sensor distance can be finely determined by targeting the valley of the curve given by the criterion. Through our novel multi-wavelength based autofocusing strategy and executing further phase retrieval process, high-resolution images can be finally retrieved. The applicability and robustness of our method is validated both in simulations and experiments. Our technique provides a useful tool for multi-wavelength lensless imaging under limited experimental conditions. (C) 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
- 5 August 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (17) , 23814-23829
Robust autofocusing method for multi-wavelength lensless imaging
Lensless imaging based on multi-wavelength phase retrieval becomes a promising technology widely used as it has simple acquisition, miniaturized size and low-cost setup. However, measuring the sample-to-sensor distance with high accuracy, which is the key for high-resolution reconstruction, is still a challenge. In this work, we propose a multiwavelength criterion to realize autofocusing modulation, i.e., achieving much higher accuracy in determining the sample-to-sensor distance, compared to the conventional methods. Three beams in different spectrums are adopted to illuminate the sample, and the resulting holograms are recorded by a CCD camera. The patterns calculated by performing back propagation of the recorded holograms, with exhaustively searched sample-to-sensor distance value, are adopted to access the criterion. Image sharpness can be accessed and the optimal sample-to-sensor distance can be finely determined by targeting the valley of the curve given by the criterion. Through our novel multi-wavelength based autofocusing strategy and executing further phase retrieval process, high-resolution images can be finally retrieved. The applicability and robustness of our method is validated both in simulations and experiments. Our technique provides a useful tool for multi-wavelength lensless imaging under limited experimental conditions. (C) 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
- 1 February 2019
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 113, 1-5
Multi-distance phase retrieval with a weighted shrink-wrap constraint
- 1 February 2019
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 113, 1-5
Multi-distance phase retrieval with a weighted shrink-wrap constraint
- Open Access
- 22 May 2018
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (11) , 14407-14420
Adaptive lens-free computational coherent imaging using autofocusing quantification with speckle illumination
Multi-distance phase retrieval (MDPR) based lensfree imaging is promising for an aberration free and compact biological imaging system. In the MDPR processing, the measurement uncertainty of the sample-to-sensor distance undermines its imaging quality and imposes a heavy workload to achieve a perfect reconstruction. The optimal distance can be searched by using an image sharpness quantification function with a refocused data set, however, the scanning is sensitive to noise and aliasing artifact for MDPR. In this work, we propose an adaptive imaging scheme with the help of a diffuser inserted in the lensfree system. The optimal sample-to-sensor distance is searched by combing speckle imaging with sharpness quantification function. With this speckle-based auxiliary, intensity patterns under a coherent illumination are directly used to achieve an in-focusing image reconstruction. Experiments are given to demonstrate the stability, imaging resolution and optical sectioning for our scheme. This method provides a simple, stable and robust tool for the auto-focusing imaging.
- 22 May 2018
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (11) , 14407-14420
Open AccessAdaptive lens-free computational coherent imaging using autofocusing quantification with speckle illumination
Multi-distance phase retrieval (MDPR) based lensfree imaging is promising for an aberration free and compact biological imaging system. In the MDPR processing, the measurement uncertainty of the sample-to-sensor distance undermines its imaging quality and imposes a heavy workload to achieve a perfect reconstruction. The optimal distance can be searched by using an image sharpness quantification function with a refocused data set, however, the scanning is sensitive to noise and aliasing artifact for MDPR. In this work, we propose an adaptive imaging scheme with the help of a diffuser inserted in the lensfree system. The optimal sample-to-sensor distance is searched by combing speckle imaging with sharpness quantification function. With this speckle-based auxiliary, intensity patterns under a coherent illumination are directly used to achieve an in-focusing image reconstruction. Experiments are given to demonstrate the stability, imaging resolution and optical sectioning for our scheme. This method provides a simple, stable and robust tool for the auto-focusing imaging.
- Open Access
- 12 February 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 2819
Giant and tunable optical torque for micro-motors by increased force arm and resonantly enhanced force
Micro-motors driven by light field have attracted much attentions for their potential applications. In order to drive the rotation of a micro-motor, structured optical beams with orbital angular momentum, spin angular momentum, anisotropic medium, and/or inhomogeneous intensity distribution should be used. Even though, it is still challenge to increase the optical torques (OT) in a flexible and controllable way in case of moderate incident power. In this paper, a new scheme achieving giant optical torque is proposed by increasing both the force arm and the force amplitude with the assistance of a ring resonator. In this case, the optical torque doesn’t act on the target directly by the incident beam, but is transmitted to it by rotating the ring resonator connected with it. Using the finite-difference in time-domain method, we calculate the optical torque and find that both the direction and the amplitude of the torque can be tuned flexibly by modifying the frequency, or the relative phases of the sources. More importantly, the optical torque obtained here by linearly polarized beams can be 3 orders larger than those obtained using the structured beams. This opt-mechanical-resonator based optical torque engineering system may find potential applications in optical driven micro-machines.
- 12 February 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 2819
Open AccessGiant and tunable optical torque for micro-motors by increased force arm and resonantly enhanced force
Micro-motors driven by light field have attracted much attentions for their potential applications. In order to drive the rotation of a micro-motor, structured optical beams with orbital angular momentum, spin angular momentum, anisotropic medium, and/or inhomogeneous intensity distribution should be used. Even though, it is still challenge to increase the optical torques (OT) in a flexible and controllable way in case of moderate incident power. In this paper, a new scheme achieving giant optical torque is proposed by increasing both the force arm and the force amplitude with the assistance of a ring resonator. In this case, the optical torque doesn’t act on the target directly by the incident beam, but is transmitted to it by rotating the ring resonator connected with it. Using the finite-difference in time-domain method, we calculate the optical torque and find that both the direction and the amplitude of the torque can be tuned flexibly by modifying the frequency, or the relative phases of the sources. More importantly, the optical torque obtained here by linearly polarized beams can be 3 orders larger than those obtained using the structured beams. This opt-mechanical-resonator based optical torque engineering system may find potential applications in optical driven micro-machines.
- 19 October 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10154, 101540E-101540E-5
Study of cylindrical optical micro-structure technology used in infrared laser protection
- 19 October 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10154, 101540E-101540E-5
Study of cylindrical optical micro-structure technology used in infrared laser protection