Huihui Xie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Huihui Xie has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Xiaodong Zhang
Department of Radiology, Peking University First Hospital, BeiJing, China
5 shared publications - Xiaoying Wang
Department of Radiology, Peking University First Hospital, BeiJing, China
5 shared publications - Shuai Ma
Department of Radiology Peking University First Hospital Beijing China
4 shared publications Huihui Wang
Department of Radiology, Peking University First Hospital, 8 Xishiku Street, Xicheng District, Beijing, 100034, China
3 shared publicationsShuai Ma
Department of Radiology, Peking University First Hospital, No. 8, Xishiku Street, Xicheng District, Beijing, 100034, China
3 shared publicationsChao Han
Department of Radiology, Peking University First Hospital, 8 Xishiku Street, Xicheng District, Beijing, 100034, China
2 shared publications
Latest Publications
- Open Access
- 27 August 2026
- Published by Springer Nature in Journal of King Saud University Computer and Information Sciences
- Vol. 38 (7) , 814
LiteRenalNet: A lightweight dual-branch network with channel–spatial co-attention for interpretable kidney CT classification
Automated classification of renal computed tomography (CT) can accelerate triage and extend reliable screening to settings where specialist expertise is scarce, yet the most accurate deep models rely on heavy general-purpose backbones, exploit only a single visual scale, and offer little insight into the basis of their predictions. We propose LiteRenalNet , a lightweight and interpretable dual-branch convolutional neural network that classifies an axial renal CT slice as normal, cyst, stone, or tumor. The network couples a shallow high-resolution detail branch, which preserves the high-frequency cues of small lesions such as calculi and thin cyst walls, with a deep low-resolution semantic branch, which encodes the global morphology of larger masses, and combines them through a bilateral co-attention fusion module. At its core is a Channel–Spatial Co-Attention (CSCA) module that, unlike conventional sequential attention, estimates channel and spatial attention along parallel paths and fuses them into a single joint three-dimensional attention map, with a zero-initialized gating that stabilizes early training. Built almost entirely from depthwise separable convolutions and inverted residual units, LiteRenalNet contains only 1.27 M parameters yet attains $$99.25\%$$ test accuracy, a macro-F1 of 0.9913, and a macro-AUC of 0.9993, misclassifying just 14 of 1, 867 slices, with clinically hazardous confusions limited to a single low-confidence tumor-as-normal case. A region-level Shapley value analysis further confirms that the model’s decisions are concentrated on the retroperitoneal renal region rather than on background artefacts, demonstrating that its high accuracy reflects clinically meaningful and trustworthy reasoning.- 27 August 2026
- Published by Springer Nature in Journal of King Saud University Computer and Information Sciences
- Vol. 38 (7) , 814
Open AccessLiteRenalNet: A lightweight dual-branch network with channel–spatial co-attention for interpretable kidney CT classification
Automated classification of renal computed tomography (CT) can accelerate triage and extend reliable screening to settings where specialist expertise is scarce, yet the most accurate deep models rely on heavy general-purpose backbones, exploit only a single visual scale, and offer little insight into the basis of their predictions. We propose LiteRenalNet , a lightweight and interpretable dual-branch convolutional neural network that classifies an axial renal CT slice as normal, cyst, stone, or tumor. The network couples a shallow high-resolution detail branch, which preserves the high-frequency cues of small lesions such as calculi and thin cyst walls, with a deep low-resolution semantic branch, which encodes the global morphology of larger masses, and combines them through a bilateral co-attention fusion module. At its core is a Channel–Spatial Co-Attention (CSCA) module that, unlike conventional sequential attention, estimates channel and spatial attention along parallel paths and fuses them into a single joint three-dimensional attention map, with a zero-initialized gating that stabilizes early training. Built almost entirely from depthwise separable convolutions and inverted residual units, LiteRenalNet contains only 1.27 M parameters yet attains $$99.25\%$$ test accuracy, a macro-F1 of 0.9913, and a macro-AUC of 0.9993, misclassifying just 14 of 1, 867 slices, with clinically hazardous confusions limited to a single low-confidence tumor-as-normal case. A region-level Shapley value analysis further confirms that the model’s decisions are concentrated on the retroperitoneal renal region rather than on background artefacts, demonstrating that its high accuracy reflects clinically meaningful and trustworthy reasoning. - 5 August 2019
- Published by Springer Nature in European Radiology
- Vol. 30 (1) , 87-98
Noncontrast computer tomography–based radiomics model for predicting intracerebral hemorrhage expansion: preliminary findings and comparison with conventional radiological model
Objectives To develop a radiomics model for predicting hematoma expansion in patients with intracerebral hemorrhage (ICH) and to compare its predictive performance with a conventional radiological feature-based model. Methods We retrospectively analyzed 251 consecutive patients with acute ICH. Two radiologists independently assessed baseline noncontrast computed tomography (NCCT) images. For each radiologist, a radiological model was constructed from radiological variables; a radiomics score model was constructed from high-dimensional quantitative features extracted from NCCT images; and a combined model was constructed using both radiological variables and radiomics score. Development of models was constructed in a primary cohort (n = 177). We then validated the results in an independent validation cohort (n = 74). The primary outcome was hematoma expansion. We compared the three models for predicting hematoma expansion. Predictive performance was assessed with the receiver operating characteristic (ROC) curve analysis. Results In the primary cohort, combined model and radiomics model showed greater AUCs than radiological model for both readers (all p < .05). In the validation cohort, combined model and radiomics model showed greater AUCs, sensitivities, and accuracies than radiological model for reader 2 (all p < .05). Combined model showed greater AUC than radiomics model for reader 1 only in the primary cohort (p = .03). Performance of three models was comparable between reader 1 and reader 2 in both cohorts (all p > .05). Conclusions NCCT-based radiomics model showed high predictive performance and outperformed radiological model in the prediction of early hematoma expansion in ICH patients. Key Points • Radiomics model showed better performance for prediction of hematoma expansion in patients with intracerebral hemorrhage than radiological feature-based model. • Hematomas which expanded in follow-up NCCT tended to be larger in baseline volume, more irregular in shape, more heterogeneous in composition, and coarser in texture. • A radiomics model provides a convenient and objective tool for prediction of hematoma expansion that helps to define subsets of patients who would benefit from anti-expansion therapy.
- 5 August 2019
- Published by Springer Nature in European Radiology
- Vol. 30 (1) , 87-98
Noncontrast computer tomography–based radiomics model for predicting intracerebral hemorrhage expansion: preliminary findings and comparison with conventional radiological model
Objectives To develop a radiomics model for predicting hematoma expansion in patients with intracerebral hemorrhage (ICH) and to compare its predictive performance with a conventional radiological feature-based model. Methods We retrospectively analyzed 251 consecutive patients with acute ICH. Two radiologists independently assessed baseline noncontrast computed tomography (NCCT) images. For each radiologist, a radiological model was constructed from radiological variables; a radiomics score model was constructed from high-dimensional quantitative features extracted from NCCT images; and a combined model was constructed using both radiological variables and radiomics score. Development of models was constructed in a primary cohort (n = 177). We then validated the results in an independent validation cohort (n = 74). The primary outcome was hematoma expansion. We compared the three models for predicting hematoma expansion. Predictive performance was assessed with the receiver operating characteristic (ROC) curve analysis. Results In the primary cohort, combined model and radiomics model showed greater AUCs than radiological model for both readers (all p < .05). In the validation cohort, combined model and radiomics model showed greater AUCs, sensitivities, and accuracies than radiological model for reader 2 (all p < .05). Combined model showed greater AUC than radiomics model for reader 1 only in the primary cohort (p = .03). Performance of three models was comparable between reader 1 and reader 2 in both cohorts (all p > .05). Conclusions NCCT-based radiomics model showed high predictive performance and outperformed radiological model in the prediction of early hematoma expansion in ICH patients. Key Points • Radiomics model showed better performance for prediction of hematoma expansion in patients with intracerebral hemorrhage than radiological feature-based model. • Hematomas which expanded in follow-up NCCT tended to be larger in baseline volume, more irregular in shape, more heterogeneous in composition, and coarser in texture. • A radiomics model provides a convenient and objective tool for prediction of hematoma expansion that helps to define subsets of patients who would benefit from anti-expansion therapy.
- 18 July 2019
- Published by Springer Nature in Molecular Imaging and Biology
- Vol. 22 (3) , 711-721
Preoperative Prediction of Extracapsular Extension: Radiomics Signature Based on Magnetic Resonance Imaging to Stage Prostate Cancer
Purpose To investigate and validate the potential role of a radiomics signature in predicting the side-specific probability of extracapsular extension (ECE) of prostate cancer (PCa). Procedures The preoperative magnetic resonance imaging data of 238 prostatic samples from 119 enrolled PCa patients were retrospectively assessed. The samples with were randomized in a two-to-one ratio into training (n = 74) and validation (n = 45) datasets. The radiomics features were derived from T2-weighted images (T2WIs). The optimal radiomics features were identified from the least absolute shrinkage and selection operator (LASSO) logistic regression model and were used to construct a predictive radiomics signature via dimension reduction and selection approaches. The association between the radiomics signatures and pathological ECE status was explored. Receiver operating characteristic (ROC) analysis was used to assess the discriminatory ability of the signature. The calibration performance and clinical usefulness of the radiomics signature were subsequently assessed by calibration curve and decision curve analyses. Results The proposed radiomics signature that incorporated 17 selected radiomics features was significantly associated with pathological ECE outcomes (P < 0.001) in both the training and validation datasets. The constructed model displayed good discrimination, with areas under the curve (AUC) of 0.906 (95 % confidence interval (CI), 0.847, 0.948) and 0.821 (95 % CI, 0.726, 0.894) for the training and validation datasets, respectively, and had a good calibration performance. The clinical utility of this model was confirmed through decision curve analysis. Conclusions The radiomics signature based on T2WIs showed the potential to predict the side-specific probability of pathological ECE status and can facilitate the preoperative individualized predictions for PCa patients.
- 18 July 2019
- Published by Springer Nature in Molecular Imaging and Biology
- Vol. 22 (3) , 711-721
Preoperative Prediction of Extracapsular Extension: Radiomics Signature Based on Magnetic Resonance Imaging to Stage Prostate Cancer
Purpose To investigate and validate the potential role of a radiomics signature in predicting the side-specific probability of extracapsular extension (ECE) of prostate cancer (PCa). Procedures The preoperative magnetic resonance imaging data of 238 prostatic samples from 119 enrolled PCa patients were retrospectively assessed. The samples with were randomized in a two-to-one ratio into training (n = 74) and validation (n = 45) datasets. The radiomics features were derived from T2-weighted images (T2WIs). The optimal radiomics features were identified from the least absolute shrinkage and selection operator (LASSO) logistic regression model and were used to construct a predictive radiomics signature via dimension reduction and selection approaches. The association between the radiomics signatures and pathological ECE status was explored. Receiver operating characteristic (ROC) analysis was used to assess the discriminatory ability of the signature. The calibration performance and clinical usefulness of the radiomics signature were subsequently assessed by calibration curve and decision curve analyses. Results The proposed radiomics signature that incorporated 17 selected radiomics features was significantly associated with pathological ECE outcomes (P < 0.001) in both the training and validation datasets. The constructed model displayed good discrimination, with areas under the curve (AUC) of 0.906 (95 % confidence interval (CI), 0.847, 0.948) and 0.821 (95 % CI, 0.726, 0.894) for the training and validation datasets, respectively, and had a good calibration performance. The clinical utility of this model was confirmed through decision curve analysis. Conclusions The radiomics signature based on T2WIs showed the potential to predict the side-specific probability of pathological ECE status and can facilitate the preoperative individualized predictions for PCa patients.
- 6 May 2019
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 50 (6) , 1914-1925
MRI‐Based Radiomics Signature for the Preoperative Prediction of Extracapsular Extension of Prostate Cancer
Background: Radiomics approaches based on multiparametric MRI (mp‐MRI) have shown high accuracy in prostate cancer (PCa) management. However, there is a need to apply radiomics to the preoperative prediction of extracapsular extension (ECE).Purpose: To develop and validate a radiomics signature to preoperatively predict the probability of ECE for patients with PCa, compared with the radiologists' interpretations.Study Type: Retrospective.Population: In total, 210 patients with pathology‐confirmed ECE status (101 positive, 109 negative) were enrolled.Field Strength/Sequence: T2‐weighted imaging (T2WI), diffusion‐weighted imaging, and dynamic contrast‐enhanced imaging were performed on two 3.0T MR scanners.Assessment: A radiomics signature was constructed to predict the probability of ECE prior to radical prostatectomy (RP). In all, 17 stable radiomics features of 1619 extracted features based on T2WI were selected. The same images were also evaluated by three radiologists. The predictive performance of the radiomics signature was validated and compared with radiologists' interpretations.Statistical Tests: A radiomics signature was developed by a least absolute shrinkage and selection operator (LASSO) regression algorithm. Samples enrolled were randomly divided into two groups (143 for training and 67 for validation). Discrimination, calibration, and clinical usefulness were validated by analysis of the receiver operating characteristic (ROC) curve, calibration curve, and the decision curve, respectively. The predictive performance was then compared with visual assessments of three radiologists.Results: The radiomics signature yielded an AUC of 0.902 and 0.883 in the training and validation cohort, respectively, and outperformed the visual assessment (AUC: 0.600–0.697) in the validation cohort. Pairwise comparisons demonstrated that the radiomics signature was more sensitive than the radiologists (75.00% vs. 46.88%–50.00%, all P < 0.05), but obtained comparable specificities (91.43% vs. (88.57%–94.29%); P ranged from 0.64–1.00).Data Conclusion: A radiomics signature was developed and validated that outperformed the radiologists' visual assessments in predicting ECE status.Level of Evidence: 4Technical Efficacy Stage: 2J. Magn. Reson. Imaging 2019;50:1914–1925.
- 6 May 2019
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 50 (6) , 1914-1925
MRI‐Based Radiomics Signature for the Preoperative Prediction of Extracapsular Extension of Prostate Cancer
Background: Radiomics approaches based on multiparametric MRI (mp‐MRI) have shown high accuracy in prostate cancer (PCa) management. However, there is a need to apply radiomics to the preoperative prediction of extracapsular extension (ECE).Purpose: To develop and validate a radiomics signature to preoperatively predict the probability of ECE for patients with PCa, compared with the radiologists' interpretations.Study Type: Retrospective.Population: In total, 210 patients with pathology‐confirmed ECE status (101 positive, 109 negative) were enrolled.Field Strength/Sequence: T2‐weighted imaging (T2WI), diffusion‐weighted imaging, and dynamic contrast‐enhanced imaging were performed on two 3.0T MR scanners.Assessment: A radiomics signature was constructed to predict the probability of ECE prior to radical prostatectomy (RP). In all, 17 stable radiomics features of 1619 extracted features based on T2WI were selected. The same images were also evaluated by three radiologists. The predictive performance of the radiomics signature was validated and compared with radiologists' interpretations.Statistical Tests: A radiomics signature was developed by a least absolute shrinkage and selection operator (LASSO) regression algorithm. Samples enrolled were randomly divided into two groups (143 for training and 67 for validation). Discrimination, calibration, and clinical usefulness were validated by analysis of the receiver operating characteristic (ROC) curve, calibration curve, and the decision curve, respectively. The predictive performance was then compared with visual assessments of three radiologists.Results: The radiomics signature yielded an AUC of 0.902 and 0.883 in the training and validation cohort, respectively, and outperformed the visual assessment (AUC: 0.600–0.697) in the validation cohort. Pairwise comparisons demonstrated that the radiomics signature was more sensitive than the radiologists (75.00% vs. 46.88%–50.00%, all P < 0.05), but obtained comparable specificities (91.43% vs. (88.57%–94.29%); P ranged from 0.64–1.00).Data Conclusion: A radiomics signature was developed and validated that outperformed the radiologists' visual assessments in predicting ECE status.Level of Evidence: 4Technical Efficacy Stage: 2J. Magn. Reson. Imaging 2019;50:1914–1925.
- 8 March 2019
- Published by Springer Nature in Molecular Imaging and Biology
- Vol. 21 (6) , 1157-1164
Preoperative Differentiation of Uterine Sarcoma from Leiomyoma: Comparison of Three Models Based on Different Segmentation Volumes Using Radiomics
To investigate the impact of applying three different volume of interests (VOIs) in ADC map-based radiomic analysis and compare their diagnostic performance in the differentiation of uterine sarcoma and atypical leiomyoma.
- 8 March 2019
- Published by Springer Nature in Molecular Imaging and Biology
- Vol. 21 (6) , 1157-1164
Preoperative Differentiation of Uterine Sarcoma from Leiomyoma: Comparison of Three Models Based on Different Segmentation Volumes Using Radiomics
To investigate the impact of applying three different volume of interests (VOIs) in ADC map-based radiomic analysis and compare their diagnostic performance in the differentiation of uterine sarcoma and atypical leiomyoma.