RGRobert Guidoin

Robert Guidoin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Robert Guidoin has a total of 27 co-authors. Here are the top co-authors by number of shared publications:

  • André P. Legrand

    Laboratoire de Physique Quantique, ESPCI, 10 rue Vauquelin, 75005, Paris, France

    2 shared publications
  • Marie-France Guidoin

    Laval University

    2 shared publications
  • Ze Zhang

    Quebec Biomaterials Institute, CHUQ and Department of Surgery, Laval University, Quebec (QC), Canada

    2 shared publications
  • A. P. Legrand

    Laboratoire de Physique Quantique, ESPCI, Paris, France

    1 shared publication
  • Bruno Bresson

    Soft Matter Science and Engineering (SIMM) ESPCI Paris CNRS UMR7615 PSL University Sorbonne Université Paris France

    1 shared publication
  • C.-J. Tang

    Key Lab for Biomechanics and Tissue Engineering under the State Ministry of Education, College of Bioengineering, Chongqing University, Chongqing, China

    1 shared publication

Latest Publications

  • Pivoting system fracture in a bileaflet mechanical valve: A case report

    by Hongbo Zhang, Xiaoyan Deng, Tomás Francisco Cianciulli, Ze Zhang, Daniel Chappard, Jorge Alberto Lax, Maria Cristina Saccheri, Hector Jorge Redruello, Jorge Luis Jordana, Horacio Alberto Prezioso, et al.

    A leaflet escape occurred in a low profile bileaflet mechanical prosthesis manufactured by TRI‐Technologies that had been implanted for 3 years in the mitral position of a 32 year old patient. The escaped leaflet had embolized and was subsequently located by an abdominal computerized axial tomography scan and ultrasound in the terminal portion of the aortic bifurcation. The embolized leaflet was removed 3 months after valve replacement surgery. In an attempt to determine the cause of the escape the retrieved embolized leaflet was investigated. Techniques employed included visual examination aided by stereo‐microscopy, x‐ray imaging and scanning electron microscopy. One of the ears had fractured and was missing from the leaflet. Chipping was observed at the leaflet ear position on both the inflow and outflow surfaces. Visual and SEM observations found fractographic river‐lines that indicated an apparent origin at the inflow surface of the ear nearest to the straight ‘B‐datum’ line or coaptation edge. The origin seemed to be in the radius between the leaflet ear and the leaflet body. SEM observation of the remaining intact ear showed wear marks on both the inflow and outflow sides of the leaflet ear that corresponded to the suspected origin of fracture. It is believed that the use of boron alloyed pyrolytic carbon material and the leaflet's homogeneous monolithic structural design were factors that contributed to this adverse event. © 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2009


  • The Adhesive Properties of Endothelial Cells on Endovascular Stent Coated by Substrates of Poly-L-Lysine and Fibronectin

    by G.-X. Wang, X.-Y. Deng, C.-J. Tang, L.-S. Liu, L. Xiao, L.-H. Xiang, X.-J. Quan, A. P. Legrand, R. Guidoin

    Optimizing endothelial cell growth and adhesion on the surface of metallic stents implanted in the vascular system is a fundamental issue in understanding and improving their long-term biocompatibility. The ability of the endothelial cell to attach and adhere to the luminal stent surface as well as the capacity to withstand the significant shear stress associated with blood flow are important determinants. The adhesive characteristics of human umbilical vein endothelial cells (HUVEC) on stent surfaces coated with either Poly-L-Lysine (PLL) or fibronectin (FN) were compared with uncoated controls. Increasing concentrations of PLL and FN were measured using a micropipette aspiration system. The adhesive properties of HUVECs under static flow conditions were compared to a dynamic environment on endovascular stents using a parallel-plate-flow chamber. A scanning electron microscope picture was used to measure the number and the adhesive cell ratio as well as the percentage of surface coverage of stent by endothelial cells. The adhesive forces of HUVECs on foreign surfaces coated with PLL and FN were higher compared to uncoated surfaces, and were dependent on increasing concentrations. These coatings resulted in significant increase of the adhesive force of HUVECs. The influence of substrates on the adhesion of the endothelial cell monolayer under static or dynamic flow conditions was highly significant compared with controls (p < 0.01). No significant differences were observed between PLL and FN substrates. Both PLL and FN coated surfaces can significantly increase the adhesion and growth of HUVECs on metallic stent surfaces.


  • Degenerative mineralization in the fibrous capsule of silicone breast implants

    by André P. Legrand, Georgi Marinov, Stoyan Pavlov, Marie-France Guidoin, Roger Famery, Bruno Bresson, Ze Zhang, Robert Guidoin

    The formation of a fibrous capsule made of long collagen fibers surrounding breast implants represents an unavoidable phenomenon as the patient’s reaction to the presence of a foreign body. Depending upon the size and shape of the implants and the chemicals percolating through the shell, this fibrous capsule is continuously remodeled. The compaction of the foreign debris in the vicinity of the silicone shell is followed by the loss of cellular activity, shrinkage and necrosis. Calcification is the ultimate step. These phenomena were illustrated in the analysis of 18 explanted breast prostheses after 20 or more years of implantation. The degenerative mineralization was shown in scanning electron microscopy and light microscopy. The minerals proved to be bone-like hydroxyapatite by X-ray diffraction and Solid State NMR analysis. Whatever the characteristics of any sophisticated new model of breast implant, phenomenon of mineralization might be minimized but it is very unlikely that it would be totally eliminated.


  • Poly-L-Lactide Surfaces Subjected to Long-Term Cell Cultures. Cell Proliferation and Polymer Degradation

    by Marie-France Guidoin, Robert Guidoin, Patrick Frayssinet, André P. Legrand, Thien How

    Short term cell cultures are usually grown in contact with biomaterials to assess cytocompatibility. Depending on the rate of material degradation or corrosion, the time of culture can be a key- point in the method which, if too short, may not show any effect of the released material on the cells. A long term culture was therefore carried out with L929 fibroblast cells in contact with PLLA/PDLA samples for up to eight months. The degradation was measured in terms of shear-strength properties, intrinsic viscosity of the material and its cristallinity. The effect of the material on the cells was evaluated by measuring the growth rate of the cells. A significant decrease in the shear strength of the material was measured after three months. The rate of modification of the intrinsic viscosity was regular and decreased progressively throughout the culture period. Differential scanning calorimetry showed that the samples were initially essentially amorphous and that contact with the cell culture and its medium did not change its crystallinity level. The growth rate of the cells was not modified by the presence of the material when compared to the control. This study showed this material to be cytocompatible for a long period of time, even after detection of modifications of its physico-chemical properties.