Andrew Stephens
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andrew Stephens has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Katsuo Kurabayashi
Department of Biomedical Engineering, Tandon School of Engineering, New York University, Brooklyn, NY, USA
5 shared publications - Benjamin H. Singer
Department of Internal Medicine, University of Michigan, Ann Arbor, MI 48109, United States
4 shared publications - Shiuan-Haur Su
Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI, 48109, USA
4 shared publications - Yujing Song
Department of Mechanical and Aerospace Engineering, New York University Tandon School of Engineering, Brooklyn, NY, USA.
4 shared publications - Tao Cai
Department of Materials Science and Engineering, Massachusetts Institute of Technology 1 , Cambridge, Massachusetts 02139, USA
3 shared publications - Meng Ting Chung
Department of Mechanical Engineering, University of Michigan, Ann Arbor, USA
2 shared publications
Latest Publications
- 24 July 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 288, 117820
High-temporal-resolution on-site multiplex biomarker monitoring in small animals using microfluidic digital ELISA
- 24 July 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 288, 117820
High-temporal-resolution on-site multiplex biomarker monitoring in small animals using microfluidic digital ELISA
Ultrasensitive Multiparameter Phenotyping of Rare Cells Using an Integrated Digital‐Molecular‐Counting Microfluidic Well Plate
Integrated microfluidic cellular phenotyping platforms provide a promising means of studying a variety of inflammatory diseases mediated by cell‐secreted cytokines. However, immunosensors integrated in previous microfluidic platforms lack the sensitivity to detect small signals in the cellular secretion of proinflammatory cytokines with high precision. This limitation prohibits researchers from studying cells secreting cytokines at low abundance or existing at a small population. Herein, the authors present an integrated platform named the “digital Phenoplate (dPP),” which integrates digital immunosensors into a microfluidic chip with on‐chip cell assay chambers, and demonstrates ultrasensitive cellular cytokine secretory profile measurement. The integrated sensors yield a limit of detection as small as 0.25 pg mL−1 for mouse tumor necrosis factor alpha (TNF‐α). Each on‐chip cell assay chamber confines cells whose population ranges from ≈20 to 600 in arrayed single‐cell trapping microwells. Together, these microfluidic features of the dPP simultaneously permit precise counting and image‐based cytometry of individual cells while performing parallel measurements of TNF‐α released from rare cells under multiple stimulant conditions for multiple samples. The dPP platform is broadly applicable to the characterization of cellular phenotypes demanding high precision and high throughput.
Ultrasensitive Multiparameter Phenotyping of Rare Cells Using an Integrated Digital‐Molecular‐Counting Microfluidic Well Plate
Integrated microfluidic cellular phenotyping platforms provide a promising means of studying a variety of inflammatory diseases mediated by cell‐secreted cytokines. However, immunosensors integrated in previous microfluidic platforms lack the sensitivity to detect small signals in the cellular secretion of proinflammatory cytokines with high precision. This limitation prohibits researchers from studying cells secreting cytokines at low abundance or existing at a small population. Herein, the authors present an integrated platform named the “digital Phenoplate (dPP),” which integrates digital immunosensors into a microfluidic chip with on‐chip cell assay chambers, and demonstrates ultrasensitive cellular cytokine secretory profile measurement. The integrated sensors yield a limit of detection as small as 0.25 pg mL−1 for mouse tumor necrosis factor alpha (TNF‐α). Each on‐chip cell assay chamber confines cells whose population ranges from ≈20 to 600 in arrayed single‐cell trapping microwells. Together, these microfluidic features of the dPP simultaneously permit precise counting and image‐based cytometry of individual cells while performing parallel measurements of TNF‐α released from rare cells under multiple stimulant conditions for multiple samples. The dPP platform is broadly applicable to the characterization of cellular phenotypes demanding high precision and high throughput.
- 1 May 2021
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 180, 113088
Machine learning-based cytokine microarray digital immunoassay analysis
- 1 May 2021
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 180, 113088
Machine learning-based cytokine microarray digital immunoassay analysis
- 13 November 2020
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 21 (2) , 331-343
A digital protein microarray for COVID-19 cytokine storm monitoring
Despite widespread concern regarding cytokine storms leading to severe morbidity in COVID-19, rapid cytokine assays are not routinely available for monitoring critically ill patients. We report the clinical application of a digital protein microarray platform for rapid multiplex quantification of cytokines from critically ill COVID-19 patients admitted to the intensive care unit (ICU) at the University of Michigan Hospital. The platform comprises two low-cost modules: (i) a semi-automated fluidic dispensing/mixing module that can be operated inside a biosafety cabinet to minimize the exposure of the technician to the virus infection and (ii) a 12–12–15 inch compact fluorescence optical scanner for the potential near-bedside readout. The platform enabled daily cytokine analysis in clinical practice with high sensitivity (−1), inter-assay repeatability (∼10% CV), and rapid operation providing feedback on the progress of therapy within 4 hours. This test allowed us to perform serial monitoring of two critically ill patients with respiratory failure and to support immunomodulatory therapy using the selective cytopheretic device (SCD). We also observed clear interleukin-6 (IL-6) elevations after receiving tocilizumab (IL-6 inhibitor) while significant cytokine profile variability exists across all critically ill COVID-19 patients and to discover a weak correlation between IL-6 to clinical biomarkers, such as ferritin and C-reactive protein (CRP). Our data revealed large subject-to-subject variability in patients' response to COVID-19, reaffirming the need for a personalized strategy guided by rapid cytokine assays.
- 13 November 2020
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 21 (2) , 331-343
A digital protein microarray for COVID-19 cytokine storm monitoring
Despite widespread concern regarding cytokine storms leading to severe morbidity in COVID-19, rapid cytokine assays are not routinely available for monitoring critically ill patients. We report the clinical application of a digital protein microarray platform for rapid multiplex quantification of cytokines from critically ill COVID-19 patients admitted to the intensive care unit (ICU) at the University of Michigan Hospital. The platform comprises two low-cost modules: (i) a semi-automated fluidic dispensing/mixing module that can be operated inside a biosafety cabinet to minimize the exposure of the technician to the virus infection and (ii) a 12–12–15 inch compact fluorescence optical scanner for the potential near-bedside readout. The platform enabled daily cytokine analysis in clinical practice with high sensitivity (−1), inter-assay repeatability (∼10% CV), and rapid operation providing feedback on the progress of therapy within 4 hours. This test allowed us to perform serial monitoring of two critically ill patients with respiratory failure and to support immunomodulatory therapy using the selective cytopheretic device (SCD). We also observed clear interleukin-6 (IL-6) elevations after receiving tocilizumab (IL-6 inhibitor) while significant cytokine profile variability exists across all critically ill COVID-19 patients and to discover a weak correlation between IL-6 to clinical biomarkers, such as ferritin and C-reactive protein (CRP). Our data revealed large subject-to-subject variability in patients' response to COVID-19, reaffirming the need for a personalized strategy guided by rapid cytokine assays.
- 1 August 2019
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 19 (18) , 3065-3076
Mass-producible microporous silicon membranes for specific leukocyte subset isolation, immunophenotyping, and personalized immunomodulatory drug screening in vitro
Widespread commercial and clinical adaptation of biomedical microfluidic technology has been limited in large part due to the lack of mass producibility of polydimethylsiloxane (PDMS) and glass-based devices commonly as reported in the literature. Here, we present a batch-fabricated, robust, and mass-producible immunophenotyping microfluidic device using silicon micromachining processes. Our Si and glass-based microfluidic device, named the silicon microfluidic immunophenotyping assay (SiMIPA), consists of a highly porous (∼40%) silicon membrane that can selectively separate microparticles below a certain size threshold. The device is capable of isolating and stimulating specific leukocyte populations, and allows for measuring their secretion of cell signaling proteins by means of a no-wash homogeneous chemiluminescence-based immunoassay. The high manufacturing throughput (∼170 devices per wafer) makes a large quantity of SiMIPA chips readily available for clinically relevant applications, which normally require large dataset acquisitions for statistical accuracy. With 30 SiMIPA chips, we performed in vitro immunomodulatory drug screening on isolated leukocyte subsets, yielding 5 data points at 6 drug concentrations. Furthermore, the excellent structural integrity of the device allowed for samples and reagents to be loaded using a micropipette, greatly simplifying the experimental protocol.
- 1 August 2019
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 19 (18) , 3065-3076
Mass-producible microporous silicon membranes for specific leukocyte subset isolation, immunophenotyping, and personalized immunomodulatory drug screening in vitro
Widespread commercial and clinical adaptation of biomedical microfluidic technology has been limited in large part due to the lack of mass producibility of polydimethylsiloxane (PDMS) and glass-based devices commonly as reported in the literature. Here, we present a batch-fabricated, robust, and mass-producible immunophenotyping microfluidic device using silicon micromachining processes. Our Si and glass-based microfluidic device, named the silicon microfluidic immunophenotyping assay (SiMIPA), consists of a highly porous (∼40%) silicon membrane that can selectively separate microparticles below a certain size threshold. The device is capable of isolating and stimulating specific leukocyte populations, and allows for measuring their secretion of cell signaling proteins by means of a no-wash homogeneous chemiluminescence-based immunoassay. The high manufacturing throughput (∼170 devices per wafer) makes a large quantity of SiMIPA chips readily available for clinically relevant applications, which normally require large dataset acquisitions for statistical accuracy. With 30 SiMIPA chips, we performed in vitro immunomodulatory drug screening on isolated leukocyte subsets, yielding 5 data points at 6 drug concentrations. Furthermore, the excellent structural integrity of the device allowed for samples and reagents to be loaded using a micropipette, greatly simplifying the experimental protocol.